• Title/Summary/Keyword: V.A.K.

Search Result 24,917, Processing Time 0.061 seconds

Electrostatic Discharge Experiment for Smartphone Battery Protection Circuit Module (스마트폰 배터리 보호회로 모듈에 대한 정전기 방전 실험)

  • Yoo, Jong-Gyeong;Park, Kyung-Je;Jeon, Seong-Hyeok;Yeo, Junho;Cho, Young-Ki;Lee, Dae-Heon;Kim, Jong-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.53-54
    • /
    • 2017
  • In this paper, we have studied the electrostatic discharge test for the battery protection circuit module in the lithium ion battery used as a smartphone battery which is used to prevent the explosion hazard due to overcharge, over discharge, and short-circuit. A lithium ion battery of S company was used as an experimental sample, and an ESD gun simulator compliant with IEC 61000-4-2 standard was used for electrostatic discharge injection. The contact discharge was applied to the various pins of the battery protection circuit module in increments of 2 kV in the range of 2 kV to 10 kV and in 5 kV increments in the range of 10 kV to 30 kV.

  • PDF

Drosophila melanogaster Is Susceptible to Vibrio cholerae Infection

  • Park, Shin-Young;Heo, Yun-Jeong;Kim, Kun-Soo;Cho, You-Hee
    • Molecules and Cells
    • /
    • v.20 no.3
    • /
    • pp.409-415
    • /
    • 2005
  • Infection of Drosophila melanogaster adults with 6 Vibrio species revealed that V. cholerae was lethal (100% mortality) within 20 h as a result of systemic infection. Avirulent infection by V. vulnificus restricted the subsequent virulent infection by V. cholerae. The immediate transcription of antimicrobial peptides (AMPs), most notably Attacin A, was delayed in V. cholerae infection compared to V. vulnificus infection. Ectopic expression of Attacin A and Metchnikowin enhanced the survival of D. melanogaster upon V. cholerae infection. These results suggest that AMPs are important in the response to infections by Vibrio species and that the signaling pathways governing their expression may be targeted by V. cholerae virulence factors to elude the innate immunity of Drosophila.

A Novel Approach for the Unit Commitment with Vehicle-to-grid

  • Jin, Lei;Yang, Huan;Zhou, Yuying;Zhao, Rongxiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.367-374
    • /
    • 2013
  • The electrical vehicles (EV) with vehicle-to-grid (V2G) capability can be used as loads, energy sources and energy storage in MicroGrid integrated with renewable energy sources. The output power of generators will be reallocated in the considering of V2G. An intelligent unit commitment (UC) with V2G for cost optimization is presented in this paper. A new constraint of UC with V2G is considered to satisfy daily use of EVs. A hybrid optimiza-tion algorithm combined Binary Particle Swarm Optimization (BPSO) with Lagrange Mul-tipliers Method (LMM) is proposed. The difference between results of UC with V2G and UC without V2G is presented.

Effects of Ground Faults on the Safety of Persons and Low-voltage Installations in 22.9 kV-Y Distribution Systems (22.9 kV-Y 계통에서 지락고장이 인체 및 저압설비의 안전에 미치는 영향)

  • Kim, Han-Soo;Chung, Jae-Hee;Kang, Kae-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.141-148
    • /
    • 2008
  • This paper presents experimental results on the safety of persons and protection of low-voltage equipments of the sub-station due to a single-phase ground fault in 22.9 kV-Y distribution system. In order to evaluate the hazard voltages and the stress voltage of the low-voltage(LV) equipment due to faults between high-voltage systems and earth based on the newly prescribed KS C IEC 60364 standard series, the verification tests in a 22.9[kV] neutral multiple grounding system were carried out. From the experimental results, we introduce serious problems causing some discomfort when applying KS C IEC 60364 standard series to the existing domestic distribution system and the effective protective measures against temporary overvoltages due to a ground fault in the common grounding which is combined the 22.9 kV-Y grounding and the customer's installation grounding are proposed. As a consequence, it was found that the equipotential bonding is an important prerequisite for the effectiveness of the protective measures for the safety of persons and LV equipment in the combined 22.9 kV-Y and low-voltage grounding system.

Reliability Verification of Secured V2X Communication for Cooperative Automated Driving (자율협력주행을 위한 V2X 보안통신의 신뢰성 검증)

  • Jung, Han-gyun;Lim, Ki-taeg;Shin, Dae-kyo;Yoon, Sang-hun;Jin, Seong-keun;Jang, Soo-hyun;Kwak, Jae-min
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.391-399
    • /
    • 2018
  • V2X communication is a technology in which a vehicle exchanges information with various entities such as other vehicles, infrastructure, networks, pedestrians, etc. through a wired or wireless network. Recently, V2X communication technology has been steadily developed and recently it has played an important role in autonomous cooperation driving technology combined with autonomous vehicle technology. Autonomous vehicles can utilize the external information received via V2X communication to extend the recognition range of existing sensors and to support more safe and natural autonomous driving. In order to operate these autonomous cooperative vehicles on public roads, the security and reliability of autonomous V2X communication should be verified in advance. In this paper, we present test scenarios and test procedures of secure V2X communication for cooperative automated driving and present verification results.

Isolation and Characterization of Antibiotic Resistant Vibrio Strains from Japanese Eel (Anguilla Japonica) Cultured in Korea (국내산 양식 뱀장어에서 항생제 내성 비브리오 세균 분리 및 특성)

  • Park, S.Y.;Kim, J.H.;Jun, J.W.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.22 no.2
    • /
    • pp.51-58
    • /
    • 2020
  • Continuous mortality in commercially cultured Japanese eel (Anguilla japonica), showing symptoms of dermal ulcerations and focal hemorrhages on the body, occurred on a private farm in November, 2019 in Korea. A series of mortality had been described in one local eel culture farm from November to December in 2019. From the three cases, three isolates of Vibrio spp. were recovered from the blood, ascitic fluid, and kidney of the dead fish, respectively. Based on the 16S rRNA sequence comparisons, the Vibrio isolates from the 1st and 3rd cases (strain named 1E1-2 and 3K1-2) were identified as V. fluvialis and the isolate from the 2nd case was identified as V. plantisponsor (strain named 2A3-1). Moreover, the 16S rRNA-based phylogenetic analysis revealed that strain 1E1-2 and 3K1-2 were most similar to V. fluvialis NBRC 103150T, and strain 2A3-1 was most similar to V. plantisponsor NBRC103148T. According to the results of the antibiotic resistance determination, V. fluvialis 1E1-2 showed intermediate resistance to tetracycline and chloramphenicol, and was resistant to trimethoprim-sulfamethoxazole. V. plantisponsor 2A3-1 showed intermediate resistance to ciprofloxacin and levofloxacin, and was resistant to trimethoprim-sulfamethoxazole. V. fluvialis 3K1-2 showed intermediate resistance to tetracycline, and was resistant to ampicillin and trimethoprim-sulfamethoxazole. These results have provided the evidences on the occurrence of antibiotic-resistant Vibrio infection in commercially cultured Japanese eels are present in Korea.

Porous fiber filled by liquid crystal for flexible displays and E-paper technology

  • Mashchenko, V.I.;Udra, S.A.;Sorokin, V.V.;Gerasimov, V.I;Belyaev, V.V.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1249-1250
    • /
    • 2004
  • In this paper, we report new technique of preparation of material for flexible displays and E-paper technology. This material represents porous polymeric fiber based on polyacrylonitrile filled by liquid crystal.

  • PDF

NuSEE: AN INTEGRATED ENVIRONMENT OF SOFTWARE SPECIFICATION AND V&V FOR PLC BASED SAFETYCRITICAL SYSTEMS

  • Koo, Seo-Ryong;Seong, Poong-Hyun;Yoo, Jun-Beom;Cha, Sung-Deok;Youn, Cheong;Han, Hyun-Chul
    • Nuclear Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.259-276
    • /
    • 2006
  • As the use of digital systems becomes more prevalent, adequate techniques for software specification and analysis have become increasingly important in nuclear power plant (NPP) safety-critical systems. Additionally, the importance of software verification and validation (V&V) based on adequate specification has received greater emphasis in view of improving software quality. For thorough V&V of safety-critical systems, V&V should be performed throughout the software lifecycle. However, systematic V&V is difficult as it involves many manual-oriented tasks. Tool support is needed in order to more conveniently perform software V&V. In response, we developed four kinds of computer aided software engineering (CASE) tools to support system specification for a formal-based analysis according to the software lifecycle. In this work, we achieved optimized integration of each tool. The toolset, NuSEE, is an integrated environment for software specification and V&V for PLC based safety-critical systems. In accordance with the software lifecycle, NuSEE consists of NuSISRT for the concept phase, NuSRS for the requirements phase, NuSDS for the design phase and NuSCM for configuration management. It is believed that after further development our integrated environment will be a unique and promising software specification and analysis toolset that will support the entire software lifecycle for the development of PLC based NPP safety-critical systems.

POSITIVE RADIAL SOLUTIONS FOR A CLASS OF ELLIPTIC SYSTEMS CONCENTRATING ON SPHERES WITH POTENTIAL DECAY

  • Carriao, Paulo Cesar;Lisboa, Narciso Horta;Miyagaki, Olimpio Hiroshi
    • Bulletin of the Korean Mathematical Society
    • /
    • v.50 no.3
    • /
    • pp.839-865
    • /
    • 2013
  • We deal with the existence of positive radial solutions concentrating on spheres for the following class of elliptic system $$\large(S) \hfill{400} \{\array{-{\varepsilon}^2{\Delta}u+V_1(x)u=K(x)Q_u(u,v)\;in\;\mathbb{R}^N,\\-{\varepsilon}^2{\Delta}v+V_2(x)v=K(x)Q_v(u,v)\;in\;\mathbb{R}^N,\\u,v{\in}W^{1,2}(\mathbb{R}^N),\;u,v&gt;0\;in\;\mathbb{R}^N,}$$ where ${\varepsilon}$ is a small positive parameter; $V_1$, $V_2{\in}C^0(\mathbb{R}^N,[0,{\infty}))$ and $K{\in}C^0(\mathbb{R}^N,[0,{\infty}))$ are radially symmetric potentials; Q is a $(p+1)$-homogeneous function and p is subcritical, that is, 1 < $p$ < $2^*-1$, where $2^*=2N/(N-2)$ is the critical Sobolev exponent for $N{\geq}3$.

A simulation study on the figure of merit optimization of a 1200V 4H-SiC DMOSFET (1200V급 4H-SiC DMOSFET 성능지수 최적화 설계 시뮬레이션)

  • Choi, Chang-Yong;Kang, Min-Suk;Bang, Wook;Kim, Sang-Chul;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.63-63
    • /
    • 2009
  • In this work, we demonstrate 800V 4H-SiC power DMOSFETs with several structural alterations to observe static DC characteristics, such as a threshold voltage ($V_{TH}$) and a figure of merit ($V_B^2/R_{SP,ON}$). To optimize the static DC characteristics, we consider four design parameters; (a) the doping concentration ($N_{CSL}$) of current spreading layer (CSL) beneath the p-base region, (b) the thickness of p-base ($t_{BASE}$), (c) the doping concentration ($N_J$) and width ($W_J$) of a JFET region, (d) the doping concentration ($N_{EPI}$) and thickness ($t_{EPI}$) of epi-layer. Design parameters are optimized using 2D numerical simulations and the 4H-SiC DMOSFET structure results in high figure of merit ($V_B^2/R_{SP,ON}$>~$340MW/cm^2$) for a power MOSFET in $V_B{\sim}1200V$ range.

  • PDF