• Title/Summary/Keyword: V² control

Search Result 4,903, Processing Time 0.035 seconds

Design of an Energy Management System for On-Chip Solar Energy Harvesting (온칩 태양 에너지 하베스팅을 위한 에너지 관리 시스템 설계)

  • Jeon, Ji-Ho;Lee, Duck-Hwan;Park, Joon-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.15-21
    • /
    • 2011
  • In this paper, an energy management circuit for solar energy harvesting system is designed in $0.35{\mu}m$ CMOS technology. The solar energy management system consists of an ISC(Integrated Solar Cell), a voltage booster, and an MPPT(Maximum Power Point Tracker) control unit. The ISC generates an open circuit voltage of 0.5V and a short circuit current of $15{\mu}A$. The voltage booster provides the following circuit with a supply voltage about 1.5V. The MPPT control unit turns on the pMOS switch to provide the load with power while the ISC operates at MPP. The SEMU(Solar Energy Management Unit) area is $360{\mu}m{\times}490{\mu}m$ including pads. The ISC area is $500{\mu}m{\times}2000{\mu}m$. Experimental results show that the designed SEMU performs proper MPPT control for solar energy harvested from the ISC. The measured MPP voltage range is about 370mV∼420mV.

Maximum Power Point Tracking Method Without Input side Voltage and current Sensor of DC-DC Converter for Thermoelectric Generation (열전발전을 위한 DC-DC Converter의 입력측 전압·전류 센서없는 최대전력점 추적방식)

  • Kim, Tae-Kyung;Park, Dae-Su;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.569-575
    • /
    • 2020
  • Recently, research on renewable energy technologies has come into the spotlight due to rising concerns over the depletion of fossil fuels and greenhouse gas emissions. Demand for portable electronic and wearable devices is increasing, and electronic devices are becoming smaller. Energy harvesting is a technology for overcoming limitations such as battery size and usage time. In this paper, the V-I characteristic curve and internal resistance of thermal electric devices were analyzed, and MPPT control methods were compared. The Perturbation and Observation (P&O) control method is economically inefficient because two sensors are required to measure the voltage and current of a Thermoelectric Generator(TEG). Therefore, this paper proposes a new MPPT control method that tracks MPP using only one sensor for the regulation of the output voltage. The proposed MPPT control method uses the relationship between the output voltage of the load and the duty ratio. Control is done by periodically sampling the output voltage of the DC-DC converter to increase or decrease the duty ratio to find the optimal duty ratio and maintain the MPP. A DC-DC converter was designed using a cascaded boost-buck converter, which has a two-switch topology. The proposed MPPT control method was verified by simulations using PSIM, and the results show that a voltage, current, and power of V=4.2 V, I=2.5 A, and P=10.5 W were obtained at the MPP from the V-I characteristic curve of the TEG.

Remote Control System of Ion Implanter (이온주입장치의 원격제어시스템 구축)

  • 이재형;양대정
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1042-1047
    • /
    • 2003
  • The goal of this research is to implement a PC-based remote control system of ion implanter using Visual Basic programming. Presently, skilled process engineers are required to regularly setup and adjust implanter parameters. Any reduction in the number of production hours devoted to ion beam implanter setup or recalibration after a species change would represent substantial improvements in both manpower and equipment utilization. An optical communication system for the remote control and telemetry in the operation of the 50kev potential was designed and constructed. This system enables continuous and safe operation of the ion implanter and can be the basis for the automation. The isolation characteristics of optical fiber were 10kV/cm, and performance tests of the system under the intense noise environment during the implanter operations showed satisfactory results. This system is designed to completely replace the existing human-machine interface with many new functions. This paper describes the important components of the system including system architecture and software development. It is expected that this system can be used for the communication and control purpose in the high noise environments such as the operation of the MeV energy implanter or other high power, high noise systems.

The New Voltage Event Detection Method and Control System Design for DVR Applied to 22.9kV Distribution System (22.9kV 배전선로 적용을 위한 DVR의 새로운 외란검출 기법 및 제어시스템 설계)

  • Kim H.J.;Chung Y.H.;Kwon G.H.;Park T.B.;Moon J.I.;Jeon Y.S.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • This paper proposes the new voltage event detection method using the weight factor of neural network and describes control system design for the DVR(Dynamic Voltage Restorer) consisted of a rectifier and series inverter applied to 22.9kV distribution system. As this method can express the fault level of each phase, we expect the proposed method can make up for disadvantage of synchronous detection method. Also, in this paper, the control system was designed using double deadbeat controller, As it has an inner current control loop and an outer voltage control loop, we can easily limit the current level during the transient intervals by using the current control loop. Simulation and experiment are performed to prove the analysis of the voltage event detection method and double deadbeat controller.

A Tentative Methodology for Quality Control of Trackbed Fills Using Field and Laboratory P-Wave Measurements

  • Park, Chul-Soo;Park, In-Beom;Kim, Eun-Jung;Mok, Young-Jin
    • International Journal of Railway
    • /
    • v.1 no.2
    • /
    • pp.64-71
    • /
    • 2008
  • The quality of track-bed fills of railways has been controlled by field measurements of density $({\gamma}_d)$ and the results of plate-load tests. The control measures are compatible with the design procedures whose design parameter is $k_{30}$ for both ordinary-speed railways and high-speed railways. However, one of fatal flaws of the design procedures that there are no simple laboratory measurement procedures for the design parameters ($k_{30}$ or, $E_{v2}$ and $E_{v2}/E_{v1}$) in design stage. A new quality control procedure, in parallel with the advent of the new design procedure, is being proposed. This procedure is based upon P-wave velocity involving consistently the evaluation of design parameters in design stage and the field measurements during construction. The Key concept of the procedure is that the target value for field compaction control is the P-wave velocity determined at OMC using modified compaction test, and direct-arrival method is used for the field measurements during construction. The procedure was verified at a test site and the p-wave velocity turned out to be an excellent control measure. The specifications for the control also include field compaction water content of OMC${\pm}$2% as well as the p-wave velocity.

  • PDF

Characteristics of Ni metallization on ICP-CVD SiG thin film and Ni/SiC Schottky diode (ICP-CVD로 성장된 SiC박막의 Ni 금속 접합과 Ni/SiC Schottky diode의 특성 분석)

  • Gil, Tae-Hyun;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.938-940
    • /
    • 1999
  • We have fabricated SiC Schottky diode for high temperature applications. SiC thin film for drift region has been deposited by ICP-CVD. In order to establish metallization conditions, we have extracted the device parameters of the Schottky diode from the forward I-V characteristics and the C-V characteristics as a function of temperature. The ideality factor was varied from 2.07 to 1.15 and the barrier height was also varied from 1.26eV to 1.92eV with increase of temperature. The reverse blocking voltage was 183 V.

  • PDF

Stereo-Vision Based Road Slope Estimation and Free Space Detection on Road (스테레오비전 기반의 도로의 기울기 추정과 자유주행공간 검출)

  • Lee, Ki-Yong;Lee, Joon-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.3
    • /
    • pp.199-205
    • /
    • 2011
  • This paper presents an algorithm capable of detecting free space for the autonomous vehicle navigation. The algorithm consists of two main steps: 1) estimation of longitudinal profile of road, 2) detection of free space. The estimation of longitudinal profile of road is detection of v-line in v-disparity image which is corresponded to road slope, using v-disparity image and hough transform, Dijkstra algorithm. To detect free space, we detect u-line in u-disparity image which is a boundary line between free space and obstacle's region, using u-disparity image and dynamic programming. Free space is decided by detected v-line and u-line. The proposed algorithm is proven to be successful through experiments under various traffic scenarios.

Mathematical Consideration on PV Cell Modeling (PV cell modeling의 수학적 고찰)

  • Park, Hyeonah;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.234-235
    • /
    • 2013
  • PV cell model은 PV simulator를 제작하거나 시뮬레이션 Software를 통하여 PV 발전시스템을 분석하기 위하여 필요하다. PV cell의 I-V 특성곡선은 PV cell의 특성을 결정짓는 중요한 요소이며, 전기적으로 다이오드정수($I_o$, $v_t$)와 광전류원($I_{ph}$) 그리고 직렬저항($R_s$) 및 션트저항($R_{sh}$)으로 모델링 가능하다. 광 전류원은 일사량에 비례하여 그 값을 추정할 수 있으나 나머지 변수인 다이오드정수($I_o$, $v_t$)와 직렬저항($R_s$) 및 션트저항($R_{sh}$)은 제조사 데이터시트에서 제공하는 3개의 대표적인 운전점인 개방회로 전압($V_{oc}$), 단락회로 전류($I_{sc}$), 그리고 최대출력에서의 전압/전류($V_{MPP}/I_{MPP}$)를 기초로 수학적으로 해를 구하여야만 한다. 본 논문에서는 저자가 제안하는 K-알고리즘의 수학적 도출 과정과 수치해석적 특성을 고찰한다.

  • PDF

SARS-CoV-2 mRNA Vaccine Elicits Sustained T Cell Responses Against the Omicron Variant in Adolescents

  • Sujin Choi;Sang-Hoon Kim;Mi Seon Han;Yoonsun Yoon;Yun-Kyung Kim;Hye-Kyung Cho;Ki Wook Yun;Seung Ha Song;Bin Ahn;Ye Kyung Kim;Sung Hwan Choi;Young June Choe;Heeji Lim;Eun Bee Choi;Kwangwook Kim;Seokhwan Hyeon;Hye Jung Lim;Byung-chul Kim;Yoo-kyoung Lee;Eun Hwa Choi;Eui-Cheol Shin;Hyunju Lee
    • IMMUNE NETWORK
    • /
    • v.23 no.4
    • /
    • pp.33.1-33.13
    • /
    • 2023
  • Vaccination against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been acknowledged as an effective mean of preventing infection and hospitalization. However, the emergence of highly transmissible SARS-CoV-2 variants of concern (VOCs) has led to substantial increase in infections among children and adolescents. Vaccine-induced immunity and longevity have not been well defined in this population. Therefore, we aimed to analyze humoral and cellular immune responses against ancestral and SARS-CoV-2 variants after two shots of the BNT162b2 vaccine in healthy adolescents. Although vaccination induced a robust increase of spike-specific binding Abs and neutralizing Abs against the ancestral and SARS-CoV-2 variants, the neutralizing activity against the Omicron variant was significantly low. On the contrary, vaccine-induced memory CD4+ T cells exhibited substantial responses against both ancestral and Omicron spike proteins. Notably, CD4+ T cell responses against both ancestral and Omicron strains were preserved at 3 months after two shots of the BNT162b2 vaccine without waning. Polyfunctionality of vaccine-induced memory T cells was also preserved in response to Omicron spike protein. The present findings characterize the protective immunity of vaccination for adolescents in the era of continuous emergence of variants/subvariants.

Fabrication and Characteristic Analysis of Single Poly-Si flash EEPROM (단일층 다결정 실리콘 Flash EEPROM 소자의 제작과 특성 분석)

  • Kwon Young-Jun;Jung Jung-Min;Park Keun-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.7
    • /
    • pp.601-604
    • /
    • 2006
  • In this paper, we propose the single poly-Si Flash EEPROM device with a new structure which does not need the high voltage switching circuits. The device was designed, fabricated and characterized. From the measurement results, it was found that the program, the erase and the read operations worked properly. The threshold voltage was 3.1 V after the program in which the control gate and the drain were biased with 12 V and 7 V for $100{\mu}S$, respectively. And it was 0.4 V after the erase in which the control gate was grounded and the drain were biased with 11 V for $200{\mu}S$. On the other hand, it was found that the program and the erase speeds were significantly dependent on the capacitive coupling ratio between the control gate and the floating gate. The larger the capacitive coupling ratio, the higher the speeds, but the target the area per cell. The optimum structure of the cell should be chosen with the consideration of the trade-offs.