• Title/Summary/Keyword: Utilization and storage

Search Result 721, Processing Time 0.03 seconds

Economic analysis of irrigation facilities for securing water for field crops

  • Hyung Jin Shin;Jae Young Lee;Jae Nam Lee;Han Na Lee;Sang Hyeon Park;Bum Soo Shin;Sang Sun Cha;Se Myung Kwon;Jung Il Seo;Chan Gi Park
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.785-798
    • /
    • 2023
  • Considering irrigation facilities are currently insufficient and drought vulnerability due to climate change is high, efficient measures are required to secure water supply for field crops. This study, therefore, calculated the water shortage to secure water for representative field crops. An economic analysis was further conducted by comparing the production income to the input cost for each method. Here, five distinct regions were selected to represent each crop-Cheongyang-gun for chili peppers, Yesan-gun for apples, Dangjin-si for cabbages, Seosan-si for garlic, and Goesan for beans. The regions with insufficient water supply were estimated by calculating the water requirements and the supplied water from public groundwater wells for each area. A comprehensive set of four scenarios was presented as a strategy to ensure water security and manage irrigation facilities. These scenarios comprised the maintenance of existing groundwater wells, the construction of new water storage tanks, the installation of additional groundwater wells, and the utilization of surface water. B/C (benefit/cost) analysis was conducted for each scenario. As a result, the construction of water storage tanks was selected as a facility and water management plan in Cheongyang-gun, Dangjin-si, and Seosan-si. The analysis additionally indicated the economic viability of installing surface water utilization facilities in Yesan-gun and developing water storage tanks and groundwater (aquifer) wells in Goesan-gun. The results of this study are considered to serve as foundation data that may be utilized in the selection of water management plans for drought-prone areas in the future.

A Study on the Impact of Knowledge Management Activities on Business Performance in the Sales Organization of ICT Companies (ICT 기업의 영업조직에서 지식경영 활동이 경영성과에 미치는 영향 연구)

  • Ok-Hyun Yu;Sun-Jung Yoon;Jong-Hyen Seo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.47 no.1
    • /
    • pp.28-40
    • /
    • 2024
  • Maintaining the permanence of a company in the current rapidly changing business environment is not an easy task. Rather, the lifespan of a company can be said to be gradually decreasing. As such, the author of this paper, which describes the current market environment, is the sales organization of a large company. While leading the company, I thought about how to overcome the rapidly changing market and create an organization that continues to grow. As a result, I succeeded in creating an organization that continued to grow over the past two years, and the main activity of this result was the use of sales computer. It was clear that it was an information sharing activity. This can be said to be a result of proving that a series of activities to create and share information is important for the sales organization of ICT companies to actively respond to the rapidly changing market environment. Therefore, this study attempted to examine the relationship between knowledge management and business performance in the sales field of ICT companies, which has not been covered so far. Knowledge management is a four-stage activity from a process perspective, divided into knowledge creation, knowledge storage, knowledge transfer, and knowledge utilization. did. As a result of the study, first, knowledge management activities, such as knowledge creation and knowledge storage, were found to have a significant impact on financial performance. Second, knowledge management activities such as knowledge creation, knowledge storage, knowledge transfer, and knowledge utilization were all found to have an impact on non-financial performance. In the end, this study confirmed that efforts to turn tacit knowledge into knowledge in order to respond to the ever-changing ICT market are ultimately an important factor in growing a company.

Utilization of Slaughter Porcine Blood as an Animal Feed (도축부산물인 돈혈의 재활용에 관한 연구)

  • 김정학;박강희;류경선;이제훈
    • Journal of Animal Environmental Science
    • /
    • v.3 no.2
    • /
    • pp.133-143
    • /
    • 1997
  • Optimal conditions for collecting, storing and drying temperature to utilize slaughter porcine blood for blood meals and the effects of blood meal on growth in broiler chicks were investigated. Dry matter and protein contents of slaughter procine blood were 19.5% and 77%(dry basis), respectively. As for the composites of amino acids in the blood, aspartic acid, arginine, glycine, histidine, leucine, lysine, phenylalanin threonine were shown high. There was no significant difference between the collections by bloodletting and vacuumming in terms of microbial contamination. Storage of slaughter porcine blood showed no differences in protein, DNA and triglyceride contents and pH between the storage methods of freezing (-20$^{\circ}C$) and refrigerating (-4$^{\circ}C$). In case of room temperature storage, however, the decrease in pH and the appearance of new protein due to microbial contaminations increased as the storage periods were prolonged. When drying was done by flash methods, the drying period got shortened as the temperature became higher, yet protein and triglyceride were destoryed more. When drying was done over 120$^{\circ}C$, even at the same degree, the breakdowns of protein and triglyceride increased more as drying period got longer. In feeding trials of broiler chicks, dietary supplementation of the flash dried blood meal at 2% level showed significant difference in growth rate(P<.05%). These results indicated that the appropriate handling and manufacturing of slaughter porcine blood enabled the blood to be used as a protein source for broiler chicks.

Storage Stability of Refined Sardine Oil (정제정어리유의 저장안정성에 관한 연구)

  • LEE Kang-HO;JEONG In-Hack;RYUK Ji-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.22 no.2
    • /
    • pp.95-101
    • /
    • 1989
  • For the utilization of polyunsaturated fatty acids in sardine (Sardinops melanosticta) oil, mainly as a source for dietary supplement of eicosapentaenoic acid(EPA) and docosahe-xaenoic acid(DHA), the effects of refining and storage, conditions, and addition of stabili-zing agents on the storage stability of EPA condensed and refined sardine oil were tested. Refined, sardine oil deacidified, decolored, and deodorized, was more stable to autoxidation than crude or partially purified oils such as deacidified or/and decolored. The refined sardine oil must be kept at $5^{\circ}C$ or lower temperture for longer than two month storage. The addition of $0.018\%\;\alpha-tocopherol$ or BHT could enhance the stability to autoxidation, and EDTA or citric acid was useful as synergist. Especially the addition of $0.02\%$ citric acid to the oil still hot after deodorizing process ($125^{\circ}C$) was of benefit to stabilize the refined oil.

  • PDF

A Study on the Rainwater Quality Monitoring and the Improvement, Collection and Storage System (빗물 집수 및 저장 시스템 개선과 수질 분석 모니터링)

  • Kim, Chul-Kyung
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.353-362
    • /
    • 2011
  • In our nature, the utilization of rainwater is essential for healthy water recirculation. This is one of the solutions of the increment of impermeability surface according to the development of new cities; this study of the improvement of rainwater quality has been carried on through the improvement of collecting and restoring system of rainwater. The southwestern region of Daejeon City, the rainwater coefficient of run off was 0.40 and this number had computed to 0.59 after the development. After filtration of rainwater, the heavy metal (Cu, As, Cr, Fe, Mn) contents level were lower than underground water. Moreover, collected rainwater showed better quality than underground water in following criteria; hardness, permanganate consumption quality, chloride, evaporation residue, sulfates and nitrate nitrogen. This water quality met the gray water quality standards. The rainwater quality was still suitable to use as bathroom flushing and gardening after 100 days of storage. This study proved that modification (installation of cover with gutter to existing rainwater collection system, proper filtering, and installation of underground storage tank) of collection system could improve quality of water and maintain this approximately 100 days.

Optimized Design and Coordinated Control for Stand-alone DC Micro-grid (독립형 DC 마이크로그리드의 최적화 설계와 협조적 제어)

  • Han, Tae-Hee;Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2013
  • This paper describes the coordinated droop control method for stand-alone type DC micro-grid to improve reliability and utilization of distributed generations and energy storage. The stand-alone type DC micro-grid consists of several distributed generations such as a wind power generation, solar power and micro-turbine, and energy storage. The proposed method which is based on autonomous control method shows high reliability and stability through coordinated droop control of distributed generations and energy storage and also capability of battery management. The operation of stand-alone type DC micro-grid was analyzed using detail simulation model with PSCAD/EMTDC software. Based on simulation results, a hardware simulator was built and tested with commercially available components and performance of system was verified.

Study on TES system application for industrial production facility (축냉시스템의 산업용 생산설비 적용에 대한 고찰)

  • Park, C.H.;Hong, S.S.;Kim, J.R.;Park, S.S.;Hwang, H.S.
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

FlashEDF: An EDF-style Scheduling Scheme for Serving Real-time I/O Requests in Flash Storage

  • Lim, Seong-Chae
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.26-34
    • /
    • 2018
  • In this paper, we propose a scheduling scheme that can efficiently serve I/O requests having deadlines in flash storage. The I/O requests with deadlines, namely, real-time requests, are assumed to be issued for streaming services of continuous media. Since a Web-based streaming server commonly supports downloads of HTMLs or images, we also aim to quickly process non-real-time I/O requests, together with real-time ones. For this purpose, we adopt the well-known rate-reservation EDF (RR-EDF) algorithm for determining scheduling priorities among mixed I/O requests. In fact, for the use of an EDF-style algorithm, overhead of task's switching should be low and predictable, as with its application of CPU scheduling. In other words, the EDF algorithm is inherently unsuitable for scheduling I/O requests in HDD storage because of highly varying latency times of HDD. Unlike HDD, time for reading a block in flash storage is almost uniform with respect to its physical location. This is because flash storage has no mechanical component, differently from HDD. By capitalizing on this uniform block read time, we compute bandwidth utilization rates of real-time requests from streams. Then, the RR-EDF algorithm is applied for determining how much storage bandwidth can be assigned to non-real-time requests, while meeting deadlines of real-time requests. From this, we can improve the service times of non-real-time requests, which are issued for downloads of static files. Because the proposed scheme can expand flexibly the scheduling periods of streams, it can provide a full usage of slack times, thereby improving the overall throughput of flash storage significantly.

Numerical Study on using Immersion Cooling for Thermal Management of ESS (Energy Storage System) (ESS(Energy Storage System) 열관리를 위한 액침 냉각 활용에 대한 수치해석 연구)

  • Jeonggyun Ham;Nayoung You;Myeongjae Shin;Honghyun Cho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.20 no.2
    • /
    • pp.1-10
    • /
    • 2024
  • The introduction of the sector coupling concept has expanded the scope of ESS utilization, resulting in the importance of thermal management of ESS. To ensure the safe use of the lithium-ion batteries that are used in ESS, it is important to use the batteries at the optimal temperature. To examine the utilization of liquid cooling in ESS, numerical study was conducted on the thermal characteristics of 21700 battery modules (16S2P array) during liquid cooling using Novec-649 as insulating fluid. The NTGK model, an MSMD model in ANSYS fluent, was used to investigate thermal characteristics on the battery modules with liquid immersion cooling. The results show that the final temperature of the battery module discharged at 5 C-rate is 68.9℃ using natural convection and 48.3℃ using liquid cooling. However, the temperature difference among cells in the battery module was up to 0.5℃ when using natural convection cooling and 5.8℃ when using liquid cooling, respectively, indicating that the temperature difference among cells was significantly increased when liquid cooling was used. As the mass flow rate increased from 0.01 kg/s to 0.05 kg/s, the average temperature of the battery module decreased from 48.3℃ to 38.4℃, confirming that increasing the mass flow rate of the insulating fluid improves the performance of liquid immersion cooling. Although partial liquid immersion cooling has a high cooling performance compared to natural convection cooling, the temperature difference between modules was up to 8.9℃, indicating that the thermal stress of the battery cells increased.

A Study on Optimal Capacity of Energy Storage System in Renewable Energy Based Micorgrids (신재생에너지가 연계된 마이크로그리드에서 에너지 저장장치의 최적 용량 선정에 관한 연구)

  • Kim, Wook-Won;Lee, Nam-Hyung;Lee, Yun-Sung;Shin, Je-Seok;Kim, Jin-O
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.529-533
    • /
    • 2012
  • By introducing RPS(Renewable Portfolio Standard) for reduction of greenhouse gas, Renewable energy sources have becoming widespread gradually. However, Renewable energy sources, such as wind power and PV are difficult to control the output and they have intermittent characteristics of the output. These characteristics would cause some problems when it is connected in the power system. In order to solve these problems, Energy Storage Systems(ESS) are considered to use. Although there are many different storage devices, the utilization of Secondary Battery is the one of the best ways to stabilize an output fluctuation of RES because of its fast responsibility. For that reason, it would better fit a large-capacity of Secondary battery for stabilization. However, batteries cannot be installed with a large capacity blindly because of its expensive cost. So to select proper capacity of the battery is an important consideration. This paper presented a methodology for the optimal capacity and operation of ESS in microgrids.

  • PDF