• Title/Summary/Keyword: Utility interconnection

Search Result 38, Processing Time 0.037 seconds

50KW Photovoltaic Generation System for Model House Power Supply Using Alternative Energy (대체에너지 이용 시범주택 전원용 50KW 태양광발전시스템)

  • Park, J.M.;Park, J.H.;Kim, K.B.;Lee, K.Y.;Shin, S.H.;Cho, G.B.;Baek, H.N.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1335-1337
    • /
    • 2002
  • This paper presents experimental operation with utility interactive 50kw photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for dormitory.

  • PDF

Control Strategy to Interconnect the Utility Line for 3-Phase Inverter (태양광발전 시스템용 인버터의 계통연계 제어)

  • Jung, Young-Seok;Lee, Jung-Thae;Jung, Myung-Wong;Yu, Gwon-Jong;Song, Jin-Soo;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.336-338
    • /
    • 1996
  • In this paper, a simple control strategy to interconnect the utility line system for three-phase inverter. Conventionally, such interconnection is based on the 3-phase time-domain waveform analysis, though the control based on the plane defined by the two-axis theory is common in the area of the motor control. The new instantaneous power control strategy is introduced, which is based on the d-q axis theory. Simulation results show that proposed control method has good controllability with simple strategy.

  • PDF

Efficiency characteristics analysis of residential PV System (주택용 태양광발전시스템의 성능비교 분석)

  • LEE K. Y.;CHOI Y. O.;BAEK H. L.;CHO G. B.;Lee S. G.;KIM D. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.144-146
    • /
    • 2004
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system comp-onents and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Analysis of Demonstration Research for Grid-connected Photovoltaics System (계통연계형 태양광발전시스템의 실증시험 분석)

  • Piao, Zheng-Guo;Kim, Seong-Kyeol;Lee, Kang-Yeon;Cho, Guem-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.205-207
    • /
    • 2004
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Operating Characteristics of Photovoltaics System for Chosen University Dormitory (조선대학교 기숙사 전원용 PV 시스템의 운전특성)

  • Park J.M.;Choi Y.O.;Lee K.Y.;Oh G.G.;Cho G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.564-566
    • /
    • 2006
  • This paper presents experimental operation with utility interactive 50kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for dormitory.

  • PDF

Using Demonstration PV System for Operation Efficiency Analysis (태양광발전시스템의 실증연구를 통한 운용효율 분석)

  • Park Jeong Min;Kim Seong Kyeol;Jung Byung Ho;Cho Geum-Bae;Baek Hyung Rae
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.244-246
    • /
    • 2003
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration Complex. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for Demonstration Complex.

  • PDF

Demonstration analysis of residential 3kW PV System (주택보급형 3kW PV시스템 실증연구)

  • Park, J.M.;Moon, Y.A.;Kim, H.S.;Lim, B.O.;Baek, H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.734-736
    • /
    • 2005
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system comp-onents and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Momentary Voltage Dips in the Power Distribution System Interconnected with Cogeneration Facilities (COGN) (소형 열병합 발전설비가 연계된 배전계통의 순시전압변동)

  • Choi, Joon-Ho;Kim, Jae-Chul;Jung, Sung-Kyo;Kim, Dae-Won;Han, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1088-1090
    • /
    • 1998
  • The cogeneration facilities (COGN) into the power distribution system can cause operational problems - reenergization of distribution feeders under repair by utility personnel, voltage variation and regulation because of output power of COGN, and lost of coordination at emergency state - on an electrical utility system. This paper deals with momentary voltage dips as the parallel interconnection operation of COGN in the power distribution system. PSCAD/EMTDC simulation tool is used to show the behavior of momentary voltage dips. In addition, restraint solution for momentary voltage variation is presented.

  • PDF

The operating characteristics of 50kW photovoltaic system by secular variation (경년변화에 따른 50kW급 태양광발전 시스템 운전특성)

  • Jeong, N.I.;Choi, Y.O.;Kim, D.H.;Seo, J.Y.;Cho, G.B.;Baek, H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.69-70
    • /
    • 2007
  • This paper presents experimental operation with utility interactive 50kw photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper try analyzing the operating characteristic according to secular variation of a 50kw photovoltaic system.

  • PDF

Harmonic analysis of Battery Energy Storage System on distribution system (전지전력저장시스템의 배전시스템 연계시 고조파 분석)

  • Kim, Young-Sung;Ryoo, Young-Don;Rim, Seong-Jeong;Kim, Jae-Chul;Kim, Eung-Sang;Ko, Yo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.856-858
    • /
    • 1996
  • This paper describes a simulation model to analyze the interconnection operation of battery energy storage system(BESS) and utility system. The computer model used to these analysis composed by using PSCAD/EMTDC. The impacts experienced at load side are studied when occur faults in utility system, and also harmonics analysis are implemented. Results of these study are available to design the harmonic filter.

  • PDF