• Title/Summary/Keyword: Utility Measurement

Search Result 236, Processing Time 0.027 seconds

Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications (옥내 전력선 통신 채널 임피던스 측정 장치 설계)

  • Heo, Yun-Seok
    • The Journal of Information Technology
    • /
    • v.8 no.3
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

Conversion of C2C12 Myoblast into Adipoblast with Thiazolidinediones - A Possible Basis for Intramuscular Fat Generation in Meat Animals

  • Singh, N.K.;Chae, H.S.;Hwang, I.H.;Yoo, Y.M.;Ahn, C.N.;Lee, H.J.;Park, H.J.;Chung, H.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.3
    • /
    • pp.432-439
    • /
    • 2007
  • Thiazolidinediones (TZDs) act as potent activators of the adipose differentiation program in established preadipose cell lines. TZD's have also been investigated in diabetic patients and reported to act as PPAR-${\gamma}$ ligands. In this report, the effects of TZDs on the differentiation pathway of myoblasts have been investigated. C2C12 mouse myoblasts were grown in Dulbecco's Modified Eagles medium for 4-5 days until they reached almost 100% confluency. Post-confluent cells (day 0) were further exposed to adipogenic induction medium along with TZDs for 48 hours. Thereafter, cells were exposed only to TZDs every 48 h until day 10. The control was provided with differentiation medium without any treatment. Alterations in the cells during the differentiation programme were analyzed on the basis of fusion index, oil-red-o staining, adipocyte index, adipocyte stain uptake measurement, immuno-histochemistry and western blotting. Exposure of C2C12 mouse myoblasts to TZDs prevented the expression of myosin heavy chain with parallel increase in the expression of C/EBP-${\alpha}$ and PPAR-${\gamma}$ and acquisition of adipocyte morphology, thus abolishing the formation of multinucleated myotubes. TZDs exert their adipogenic effects only in non-terminally differentiated myoblasts; myotubes were insensitive to the compound. Continuous exposure (at least 4-5 doses) to inducers after the growth arrest was essential to provide a sustained environment to the cells converting to fully matured adipoctyes. The results indicate that TZDs specifically converted the differentiation pathway of myoblasts into that of adipoblasts.

The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light (녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정)

  • Chang, K.Y.;Ko, H.C.;Lee, J.J.;Yoon, Young Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two green light emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diode is suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature. Another study showed that, green light is better for monitoring heart rate during motion than led light. However, it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensor using green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambient light and will propose a solution. This study has two parts of research method. One is measurement system that composed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmography signal is measured by measurement board that composed high-pass filter, low-pass filter and amplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmography signal is measured with lead II electrocardiography signal at the same time and it is measured at the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standard signal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform. The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparing the correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emitting diodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambient light. The waveform and heart rate that measured by two green light emitting diodes are more identical than others. The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

Development of disc cutter wear sensor prototype and its verification for ensuring construction safety of utility cable tunnels (전력구 터널 건설안전 확보를 위한 디스크커터 마모측정시스템 시작품 개발 및 성능검증)

  • Jung Joo Kim;Hee Hwan Ryu;Seung Woo Song;Seung Chul Do;Ji Yun Lee;Ho Young Jeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.2
    • /
    • pp.91-111
    • /
    • 2024
  • Most of utility cable tunnels are constructed utilizing shield TBM as part of the underground transmission line project. The TBM chamber is the only space inside the tunnel that encounters rock and soil, and is the place with the highest frequency of accident exposure, such as collapse and collision accidents. Since there is currently no way to measure the disc cutter wear from outside the chamber, frequent inspection by workers is essential. Accordingly, in this study, in order to prevent safety accidents inside the TBM chamber and expect the effect of shortening the construction period by reducing the number of chamber openings, the concept of disk cutter wear measurement technology was established and a prototype was produced. By considering prior technology and determining that magnetic sensors are most suitable for the excavation environment, wear measurement sensor package were developed integrating magnetic sensors, wireless communication modules, power supply, external casing, and monitoring systems. To verify the performance of the prototype in an actual excavation environment, a full-scale tunnelling test was performed using a 3.6 m EPB shield TBM. Based on the full-scale tests, five prototypes were operated normally among eight prototypes. It was analyzed that sensor measurement, wireless communication, and durability performance were secured within a maximum thrust of 3,000 kN and a rotation speed of 1.5 RPM.

Computer application techniques of initial and modification machining for dies with 3-Dimensional scluptured surfaces (3차원 자유곡면을 갖는 금형의 초기및 수정가공을 위한 컴퓨터 이용기술)

  • 박정현;손주리;박삼진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.273-278
    • /
    • 1988
  • This paper represents the computer application techniques of initial and modification machining for dies with 3-dimensional scluptured surfaces. All procedures from die design to die machining and measurement are covered. The component of modelling is data management and modification (extrapolation and smoothing), surface modelling, and nc program preparation. Also this paper introduces the utility for successful and efficient operation of system such as map generation, data communication, tool path verification, contour map generation, graphic processing of extrapolation and smoothing results, and CAD/CAM system interface. Examples are given to illustrate the modelling.

  • PDF

Note on the beginnings of sinusoidal testing methods

  • Tanner, R.I.
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.2
    • /
    • pp.87-90
    • /
    • 2002
  • The measurement of the storage and loss moduli (G' and G" respectively) of materials as functions of frequency is now commonplace and is of wide utility. Yet il is not easy to trace the history of such measurements. and so this article discusses the genesis of this important experimental technique. We find that the technique grew out of a parallel technique for dielectric measurements (ca. 1900) and was developed in the mid-1930s by Philippoff and others. Important breakthroughs due to digital circuitry have occurred only in the last 20 years or so.r so.

A study on the Measurement of Power system Frequency using Digital Signal Processor (디지털 신호처리기를 이용한 전력계통 주파수 측정에 관한 연구)

  • Lee, Jung-Woo;Oh, Yong-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • A frequency in electrical power system changes by the load fluctuation in utility grid, has an influence on a connected generator, and ultimately brings a big trouble in the power system. Therefore, a quick measurement of system frequency and governor control of power system is a very important factor in the reliability and the economic feasibility. Electromagnetic frequency relays in the past had the large power consumption and the difficulty of accurate measurement. After Researched and developed digital relays are very affected by the noise and the distortion, and the recently developed Microprocessor relays have problems of expensive device and time when measuring the frequency at 50[ms]. In this study, An improve algorithm that measures the power system frequency quickly and accurately is suggested, simulated by using Matlab and programmed using C code through DSP6713 KIT. This algorithm is tested to the arbitrary voltage waveform input. The results show that the suggested algorithm is effective in the accurate and quick frequency measurements.

Non-Invasive Measurement of Shear Rates of Pulsating Pipe Flow Using Echo PIV (에코 PIV를 이용한 맥동 유동에서의 in vitro 전단률 측정 연구)

  • Kim, Hyoung-Bum;Chung, In-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1567-1572
    • /
    • 2004
  • Although accurate measurement of velocity profiles, multiple velocity vectors, and shear stress in arteries is important, there is still no easy method to obtain such information in vivo. This study shows the utility of combining ultrasound contrast imaging with particle image velocimetry (PIV) for non-invasive measurement of velocity vectors. The steady flow analytical solution and optical PIV measurements (for pulsatile flow) were used for comparison. When compared to the analytical solution, both echo PIV and optical PIV resolved the steady velocity profile well. Error in shear rate as measured by echo PIV (8%) was comparable to the error of optical PIV (6.5%). In pulsatile flow, echo PIV velocity profiles agreed well with optical PIV profiles. Echo PIV followed the general profile of pulsatile shear stress across the artery but underestimated wall shear at certain time points. These studies indicate that echo PIV is a promising technique for the non-invasive measurement of velocity profiles and shear stress.

Measurement for Blood Levels of Psychotropics and Clinical Applications : Antidepressants (정신과약물의 혈중농도 측정방법 및 임상적 적용 : 항우울제를 중심으로)

  • Kim, Seung Hyun;Lee, Min Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.2 no.1
    • /
    • pp.20-27
    • /
    • 1995
  • Therapeutic montitoring of drugs is a well established clinical 1001. However, the state of art is somewhat less advanced for psychotrpoic agents than it is for other classes of drugs, for several reasons. Most psychotropics have large volumes of distribution and achieve relatively low plasma concentrations following therapeutic doses. Many have one or more active metabolites. As a consequene, the analytical methodologies are often complex and not always reliable; well-controlled clinical studies are difficult to perform; and therapeutic ranges have been difficult to establish. Despite these limitations, prudent and selective monitoring of serum drug concentrations, particularly of the tricyclic antidepressants can be helpful in clinical management. This paper presents an overview of clinical and mothodological issues surrounding the utility of blood level measurement.

  • PDF

Transition of ACTD by Measuring the Technology Readiness Level (기술성숙도 측정을 통한 ACTD 과제 전이 결정에 관한 연구)

  • Bae, Yoon-Ho;Choin, Seok-Cheol;Moon, Hee-Seung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.60-69
    • /
    • 2009
  • Recently, request far application of advanced commercial technology to the defense acquisition process, to reduce the budget and shorten development time, has been increased. To accomplish these goals, the Advanced Concept Technology Demonstration(ACTD) is used for the defense acquisition process in Korea. And User Utility Assessment is tested to make a decision for transition to acquisition process. But this process does not include measurement of technology maturity and impacts of interface and interaction among the technologies. In this research, we propose the needs of measurement of TRL and IRL and application of SRL to reduce the risk during development phase, to understand the relations of technologies, and to fulfill the requirement far transition of the ACTD project to system development and demonstration process.