• 제목/요약/키워드: Utility Measurement

검색결과 232건 처리시간 0.043초

분산형전원이 도입된 배전계통에 대한 ISLANDING DETECTION METHOD (Islanding Detection Method of Embedded Generator connected to Power Distribution System)

  • 황진수;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.522-524
    • /
    • 2000
  • The installation of small sized Embedded Generator(EG) in parallel with the utility supply was required several technical complications for protection of the system. One of the most important protection is to provide protection against islanding and out of synchronism reclosing with the utility source. This paper explains several current methods of detecting 'Loss Of Mains'(LOM). But they have not proved completely dependable, in particular when the islanded load's capacity matches that of the EG. A new loss of mains protection algorithm is presented in this paper which based on measurement of the reactive power and node voltage for detecting the islanding condition even though the EG operate in the capacity.

  • PDF

전력설비에 의한 자계 측정및 컴퓨터 시뮬레이션 (Magnetic Field Measurement and Computer Simulation for Electrical Utility Facilities)

  • 전형태;사재원;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.22-24
    • /
    • 1996
  • For two decades and more, a lot of research work on the biological effects of EMF(Electromagnetic Fields) on Human hearth have been reported. Power-frequency magnetic fields are a natural consequence of the flow of electricity. This paper deals with the modeling of electric utility facilities taking into account the line geometries. The magnetic fields profiles obtained from the computer simulation arc compared to those from measurements.

  • PDF

송전계통 고조파 유입/유출 분석 (Analysis of Harmonic Incoming and Outgoing for Transmission System)

  • 왕용필;최선영;곽노홍;전영수;박상호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.561-562
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

스포츠 레저용 차량의 진동절연을 위한 고무제품의 특성에 관한 연구 (A Study on the Characteristics of Elastomers for Vibration Isolation of Sports Utility Vehicle)

  • 사종성;김찬묵
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.671-675
    • /
    • 2001
  • Elastomers, which are engine mounts and body mounting rubbers, are traditionally designed for NVH use in vehicles, and they are designed to isolate specific unwanted frequencies. According to the measurement of the characteristics of engine mounts and body mounting rubbers, dynamic stiffness changes with respect to the driving miles accumulated in engine mounts and initial load in body mounting. This study looks at the variability in same engine mount properties, and the desired dynamic stiffness may increased with driving miles accumulated. And the dynamic stiffness of body mounting rubber changes very stiff above 150Hz.

  • PDF

3D Scanner를 이용한 인체계측방법 및 플레어스커트의 착의형태평가방법에 관한 연구 (A Study on the Feasibility of the 3D Scanning Method of Body Measurement and Wearing Evaluation)

  • 김혜경;석은영;서추연
    • 한국의류학회지
    • /
    • 제24권6호
    • /
    • pp.895-906
    • /
    • 2000
  • The study planned to testify the accuracy of the 3D scanner through analyzing the human body measurement method and the evaluation of flare skirt with 3D scanner. The results obtained from this study were as follows; First, the results of measurement for the dress form and human body by 3D scanner were more accurate than one or two dimensional measurement method. Second, from the results of the scan for the flare skirts as worn the human body, we could obtain very accurate horizontal section map. Third, in the clothing ergonomics viewpoint, the accuracy of the 3D scanner was very excellent and its utility was higher than that of the moir photography method. Therefore, the 3D scanner is very useful for the human body measurement and the wearing evaluation. In a nutshell, this study illustrates that we have to develop a program of automatic human body measurement system which will enhance the application of the 3D scanner.

  • PDF

젖소 사양관리의 통합전산화 시스템 개발 (Development of An Integrated Information System for Dairy Cattle Breeding Management)

  • 김동원;허은영;조민호;김봉혁
    • 산업공학
    • /
    • 제17권4호
    • /
    • pp.397-406
    • /
    • 2004
  • It is widely known that labor costs are continuously and rapidly growing in terms of the raw cost of products in Korea. The increased labor costs are degrading the competitiveness of dairy industry sector as in the other major industrial fields. Furthermore, the number of dairy farms is constantly decreasing while that of dairy cattle is increasing. Thus, mechanized and/or automated stockbreeding management systems are crucially required to support professional stockbreeding management, as well as to enhance the productivity of the sector. Hence this paper develops an IIS (Integrated Information System) for dairy cattle stockbreeding management. IIS is composed of five application modules and associated utility programs. The five modules are individual stock management, milking management, feeding management, propagation management, and disease management. The utility programs are involved in stock farm accounting, and handy unloading of individual stock data into a personal data acquisition device. Compared with existing foreign products, the developed system takes advantages of various stock body measurement data such as body weight, body temperature, milk conductivity, milking amount, and the number of walking steps. All the measured data are transmitted into a programmable logic controller that monitors and controls measurement devices. The transmitted data are finally aggregated into an integrated database located in the main personal computer. The integrated data are analyzed and reformed in the five modules of IIS, then, used for providing farmers with various farm states and information through application module scenes. Hence, IIS keeps the each module work in a systematic and compatible manner, while supervising the whole stockbreeding management system.

An Improvement of Intermodulation Characteristic of Base Station in Multimedia CDMA Mobile Communication

  • Park, Jung-Jin;KIm, Seon-Mi;Choi, Dong-You;Ryu, Kwnag-Jin;Choi, Dong-Woo;Noh, Sun-Kuk;Park, Chang-Kyun
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1327-1330
    • /
    • 2002
  • In this paper examines theoretical analysis of passive intermodulation and its methods of measurement and procedure. And based on the results of field measurement, it defines the reasons of passive intermodulation of base stations, suggests characteristics by device and methods of improvement to minimize the influence of a base station on passive intermodulation, and compares and analyzes the results of field measurement before and after the reasons are improved to secure the characteristics by device and the utility and adequacy of methods of improvement.

  • PDF

등간격으로 배열된 마이크로폰을 이용한 관내 유량측정 방법 (A Method for the Measurement of Flow Rate in Pipe using a Microphone Array)

  • 김용범;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1667-1674
    • /
    • 2000
  • A new method is proposed to measure the flow rate in a pipe by multiple measurements of acoustic pressure using a microphone array. It is based on the realization that variation in flow velocity affects the change in wave number. The method minimizes measurement random errors and sensor mismatch errors thereby providing practically realizable flow rate measurement. One of the advantages of the method is that it does not obstruct the flow field and can provide the time-spatial mean flow rate. Numerical simulations and experiments were conducted to verify the utility of this method.

  • PDF

초음파를 이용한 이체 평면접촉부의 정량적인 접촉압력 측정에 관한 연구 (A Study on a Quantitative Measurement of Contact Pressure Between two Rough Flat SurFaces by Means of Ultrasonic Waves.)

  • 김경모;정인성
    • 한국안전학회지
    • /
    • 제5권3호
    • /
    • pp.8-26
    • /
    • 1990
  • It is important to have exact information about the contact pressure distribution in the design of connected parts of machines and structures. In previous works, stress analyses on a two body contact problem have been carried out in large numbers. Besides, the measurement of contact stress is important to confirm the adequateness of the theoretical analysis, to verify appropriateness of Hertzian contact theory and to know the practical pressure distribution, but an excellent measuring method con't be found at present. Therefore, a quantitative measurement of contact pressure by means of ultrasonic waves using a normal probe and an angle has been proposed to measure the contact pressure distribution between two rough flat surfaces. At first, in a new proposed calibration method, the relation between mean contact pressure and sound pressure of reflected waves is obtained by using calibration blocks with various surface roughnesses made of the same material as the rectangular section beams And then, this experimental results are compared with the analytical ones, and the utility of this method is discussed.

  • PDF

옥내 전력선 통신 채널 임피던스 측정 장치 설계 (Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications)

  • 허윤석
    • 정보학연구
    • /
    • 제8권3호
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF