• Title/Summary/Keyword: Utility Measurement

Search Result 232, Processing Time 0.028 seconds

The statistical analysis for cognizance on the Chinese oriental medical doctor of the pulse meter-analyzer (중의사의 맥진기 인식에 대한 통계 분석 연구)

  • Kim, Gyeong-Cheol;Kim, Jong-Hwan;Shin, Woo-Jin;Lee, Hai-Woong;Park, Ju-Yeon;Hong, Sang-Min;Doo, Seung-Hee;Kang, Hee-Jung;Yingri, Zhao
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.2
    • /
    • pp.88-116
    • /
    • 2009
  • Background : EBM (the evidence based medicine) is the direction of the development for oriental medicine. The pulse meter-analyzer is the important part to standardize the pulse diagnosis. When we set up the direction of the study on the pulse meter-analyzer, the awereness about the pulse meter and analyzer of the clinical oriental medical doctors as consumers is very important. Objectives : In order to prepare for the mutual study and the export strategy on the pulse meter-analyzer of Korea and China, the attitude of the study and the grasp of the awereness about the pulse meter-analyzer of the Chinese medical doctors are very important. Methods : We developed the several items as the important factor of the development of the pulse meter and analyzer. They were translated by chinese medical doctor. The investigation for demend was conducted during 3 months in Guangzhou City, Guangdong Province, China. The results of the investigation was done the statistical method of frequency analysis, Chi-squared test, correspondence analysis. Results : The most important differentiation of symptom is the symptom of JANG-BU(臟腑). The method of the utility in the pulse diagnosis is Chon-Gu (寸口) pulse diagnosis and the research on Chon-Kwan-Cheok(寸關尺) is the most important measurement factor. And the typical the old pulse is the little-fine weak pulse. The pulse meter-analyzer is most suitable to the diagnosis of the hypertension and the arteriosclerosis. Conclusion : The development of the pulse analyzer including the requests of Korean and Chinese medical doctors is very important. Specially the researches on the influence factors of the traditional diagnosis and the environment of the measurement are important for developing the pulse analyze.

  • PDF

The Peak Systolic Pressure-End Systolic Volume Index Relation in Patients with Coronary Artery Disease Using Radionuclide Gated Blood Pool Scintigraphy (관상동맥질환에서 심장풀스캔을 이용한 최고수축기혈압-수측기말용적곡선의 분석)

  • Kim, Byung-Tae;Koong, Sung-Soo;Bom, Hee-Seung;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.175-182
    • /
    • 1987
  • For measurement of ventricular performance, ejection fraction (EF) has gained wide acceptance. But EF is influenced not only by changes in muscle function but also by changes in cardiac loading conditions. In case of valvular heart disease which is variable in loading conditions, EF cannot be reliable as an index of myocardial contractility. The end systolic pressure (ESP)-end systolic volume (ESV) relation, howver, is known to represent myocardial contractility, independent of changes in loading conditions. Similar results can be obtained by using peak-systolic pressure (PSP) instead of ESP. To evaluate the utility of the peak systolic pressure-end systolic volume index (PSP-ESVI) relation as an index of myocardial function, we measured $PSP&ESVI$ in 19 partents with coronary artery disease before $(PSP_1\;&\;ESVI_1)$ and after $(PSP_2\;&\;ESVI_2)$ sublingual administration of nitroglycerin. PSP was measured with standard mercury sphygmomanometer during gated blood pool scintigraphic study. ESVI was measured by count derived method after attenuation correction. $PSP_2\;&\;ESVI_2$ measurement was started when the fall of PSP was greater than 5 mmHg after 7-14 minutes post-administration of nitroglycerin. Mean values $({\pm}S.D.)$ of $PSP_1\;&\;ESVI_1$ was $124.9({\pm}20.7)mmHg\;&\;59.4({\pm}39.9)ml/M^2$. Mean values $({\pm}S.D)$ of $PSP_2\;&\;ESVI_2$, was $113.2({\pm}19.9)mmHg\;&\;37.5({\pm}26.1)ml/M^2$. There was a significant difference between mean values of $PSP_1\;&\;PSP_2$, (p<0.01), and mean values of $ESVI_1\;&\;ESVI_2$, (p<0.01). $PSP_1-PSP_2/ESV_1-ESVI_2,\;PSP_1/ESVI_1$ and EF were in the range of 0.14-5.19 mmHg/ml/$M^2$, 0.67-7.68 mmHg/ml/$M^2$ and 10.8%-74.5% respectively. $PSP_1-PSP_2/ESVI_1-ESVI_2$, and EF showed exponential correlation (r=0.85, P<0.01). The correlation coefficient between $PSP_1/ESVI_1$ and EF was 0.73(p<0.01). With the above results, we suggest that $PSP_1-PSP_2/ESVI_1-ESVI_2$, and $PSP_1/ESVI_1$, can be used as an index of myocardial function.

  • PDF

Reliability and utility of a Dry Test Bench for testing the acoustic output from a ballistic shock wave therapeutic device (탄도형 충격파 치료기의 음향 출력 시험을 위한 Dry Test Bench의 신뢰성 및 유용성)

  • Jeon, Sung Joung;Lee, Min Young;Kwon, Oh Bin;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.589-600
    • /
    • 2022
  • In order to verify the reliability of Dry Test Bench (DTB) used for testing the output energy from ballistic extracorporeal shock wave therapeutic devices, the measurements with DTB were compared with the acoustic energy measured with a Laser Doppler Vibrometer (LDV) for a commercial ballistic ESWT device. It was shown that the mechanical energy detected with DTB had variability maintained within 5 % at the same output power setting and also had a linear correlation (adj. R2 = 0.991) with the acoustic energy measured with the LDV for the entire output power settings. Using the correlation between the two methods and the correlation on the acoustic energy measured in between air and water with the LDV, the DTB measurement can be used to estimate the energy flux density in water with an average error of 7.85 % for the entire output power settings of the ballistic shock wave generator considered in the experiment. DTB provides information limited to the output mechanical energy and therefore it is not suitable for testing the various acoustic output parameters required in IEC61846 and IEC63045. However, DTB that is simple in measurement principles and easy to use is expected for manufacturers and clinical users to monitor the performance of ballistic Extracorporeal Shock Wave Therapy (ESWT) devices.

A Morphologic Study of head and face for Sasang Constitution (사상체질별(四象體質別) 두면부(頭面部)의 형태학적(形態學的) 특징(特徵))

  • Ko, Byung-Hee;Song, Il-Byung;Cho, Yong-Jin;Choi, Chang-Seok;Kim, Jong-Weon;Hong, Suck-CHull;Lee, Eui-Ju;Lee, Sang-Yong;Seo, Jeong-Sug
    • Journal of Sasang Constitutional Medicine
    • /
    • v.8 no.1
    • /
    • pp.101-186
    • /
    • 1996
  • The clinical application of constitutional Diagnosis is the most important part of Sasang constitutional medicine. It has been studied in various way. However, the study of morphologic characteristics on the face is applied for the first time. For quantitative analysis of the correlation between the sasang constitution and the shape of the face, the head-facial part of 170 cases were measured by Martin's measurement and analysis of a) the measurement value of height and the component ratio from the Gnathion to each part of face by constitution. b) the measurement value of depth and the component ratio from T-projected to each part of the face by constitution. c) the measurement value of breadth and component ratio between each parts of the facial breadth by constitution. d) the ratio of square on every part of face by constitution. e) the characteristics on each part of the face by constitution. f) the contour line of the forehead. g) the result of discriminant analysis about the constitution. Authors obtained the results from the study as follows; 1. The characteristics of Taeum-IN (1) The measurement value of Height, Breadth, T-Projected had a tendency to maximum value in general. (2) The value of lower opthal height and the square of lower opthal part was maximum. (3) The value of Pronasal T-projected length and Subnasal T-projected length was minimum, so Taeum-In has characteristics of depression in middle face, nasal part. (4) In the ratio of Breadth, T-Projected, T-Projected was minimum. (5) It was maximum that the square of nose, Alare, Middle face, Lower face and it was minimum that the square of eye. The square of nose, Alare, Middle facc, Lower face was maximum and the square of eye was minimum. (6) The curvature of the eyebrow was minimum. (7) The projection of jaw (Pogonion T-projection length) was maximum. (8) The breadth of eye was minimum. (9) There was a tendency that the projection of the forehead to the right in general. 2. The characteristics of Soeum-In (1) In all cases of projected length the measurement value was minimum. (2) The value of lower opthal height and the square of lower opthal part was minimum. (3) By the Pupulare T-projected length, the value of Pronasal T-projected length and Subnasal T-projected length was minimum, so the Soeum In's face shape is flat. (4) The square of eye, mouth, forehead was maximum and the square of nose, Alare, Middle face, Lower face was minimum. (5) The curvature of the eyebrow was maximum. (6) The projection of mouth was minimum. (7) The jaw was flat. (8) The breadth of eye was maximum. (9) There was a tendency that the projection of the forehead to the left in general. 3. The characteristics of Soyang-In. (1) In most cases of 고경 length the measurement value was minimum. (2) By the Pupulare T-projected length, each ratio of projected length was maximum, so the Soyang-In's face shape has many protrusions (3) In the ratio of Breadth, T-Projected, T-Projected was maximum. (4) The square of mouth was minimum. (5) The inclination of the forehead was minimum. (6) The projection of mouth was maximum. (7) The breadth of eye was minimum. (8) There was a tendency that the projection of the forehead to the left in general. (9) The middle face was protruded. 4. Discriminant about the constitution. According to the result of discriminant, the accuracy probability of discriminant was 85.58% in total and Taeum-In was 90.5%, Soeum-In was 70.8%, Soyang-In was 89.5%. The accuracy probability of discriminant about 3 constitutional group increased by 49.03% than the accident probility 36.55% 5. Suggestion (1) The study which gather and analysis the data should be continued. (2) The study which subdivide the characteristics of each part of the face by the constitution should be continued. (3) The analysis method about Moire should be supplement. (4) The study about the morphologic characteristics of the whole body should be continued. (5) Computer program of constitution diagnosis should be developed. (6) To increase utility of this method, the measurement should be automation.

  • PDF

Correlation of Serum Thyroglobulin and Thyroglobulin in the Wash out of the Needle in Thyroid Cancer (갑상선암에서의 혈중 Thyroglobulin 농도와 침생검 검체 Washout Solution의 Thyroglobulin 농도와의 상관관계)

  • An, Jae-Seok;Kim, Ji-Na;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.152-155
    • /
    • 2009
  • Purpose: The most widely accepted tool for follow up management of thyroid cancer patients is serum thyroglobulin (Tg) measurement, but its value is limited by the interference of anti-thyroglobulin antibodies (anti-Tg Ab). Recently thyroglobulin measurement in the wash out of fine-needle aspiration biopsy specimens (Tg-FNAB) is frequently used for differential diagnosis of recurrences/metastases. The aim of this study was the investigation of the diagnostic utility of Tg-FNAB compared with serum Tg. Materials and Methods: We enrolled 41 consecutive patients with thyroid cancer who were evaluated for Tg-FNAB between January 2007 and February 2008 retrospectively. We ruled out 6 patients who anti-Tg Ab positive (${\geq}$100 U/mL) in the RIA (BRAHMS anti-Tgn RIA 100Det; BRAHMS Aktiengesell schaft, Berlin, Germany). Serum Tg and Tg-FNAB were measured by immunoradiometric assay (BRAHMS Tg pluS RIA 100 Det; BRAHMS Aktienge sellschaft, Berlin, Germany). We evaluated for Tg-FNAB compared with serum Tg and corresponding cytological smear. To compare the values of the two the t-test was used. Results: Tg-FNAB values were significantly higher (median 1,060 ng/mL, range 0.2~434,000 ng/mL) than serum Tg (median 2.5 ng/mL, range 0.9~131 ng/mL) (p=0.0394). The rate of correspondence with Tg-FNAB between cytological result was 87.9% and 65.9% in the case of serum Tg. Tg-FNAB was positive in 28 (24 with positive and 4 with suspicious cytology). Of the remaining 13 patients with negative Tg-FNAB, 1 had suspicious and 12 had unsuspicious cytology. serum Tg was positive in 26 (17 with positive and 3 with suspicious and 6 with unsuspicious cytology), Of the remaining 15 patients with negative serum Tg, 8 was positive in cytological result and 1 had suspicious and 6 had unsuspicious cytology. Conclusions: Tg-FNAB measurement is more accurate with high sensitivity (87.9%) than serum Tg (65.9%). The Tg-FNAB was a useful predictor for detecting recurrences/metastases with serum Tg.

  • PDF

Effect of delayed time, surface treatment, and repair material on shear bond strength of repaired bis-acryl composite resin (수리된 비스 아크릴 복합 레진의 전단결합강도에 대한 지연시간, 표면처리, 수리 재료의 영향)

  • Park, Ji-su;Lee, Jae-In
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.89-96
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effect of delayed time, surface treatment, and repair materials on repair of bis-acryl composite resin through comparison of shear bond strength and to evaluate the utility of bis-acryl composite resin repair using polymethyl methacrylate resin. Materials and Methods: A total of 90 bis-acryl composite resin specimens were fabricated and classified into 9 test groups, each of 10 pieces according to delayed time, surface treatment and repair material. The shear bond strength of each specimen was measured using a universal testing machine immediately after fabrication and analyzed using a statistical analysis program (IBM SPSS statistics 20). After the shear bond strength measurement, the fracture surface of the specimen was observed. Results: The highest shear bond strength ($17.54{\pm}3.14MPa$) was observed in the experimental group bonded immediately with a light-curing flowable composite resin using a bonding agent. Conclusion: When repairing bis-acryl composite resin, it is necessary to consider whether to remake according to the delayed time. For effective repair, it is desirable to consider appropriate materials and surface treatment methods according to the site or purpose of use.

The Establishment of a High Resolution(1Km×1Km) Wind Energy Map Based on a Statistical Wind Field Model (통계적 바람장모형에의한 고해상도(1Km×1Km)풍력에너지지도 작성에 관한 연구)

  • Kim, Hea-Jung;Kim, Hyun-Sik;Choi, Young-Jean;Byon, Jae-Young
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.6
    • /
    • pp.1157-1167
    • /
    • 2010
  • This paper details a method for establishing a wind energy map having($1Km{\times}1Km$) resolution. The map is essential for measurement and efficiency-testing of wind energy resources and wind site analysis. To this end, a statistical wind field model is estimated that covers 345,682 regions obtained by $1Km{\times}1Km$ lattices made over South Korea. The paper derives various characteristics of a regional wind energy resource under the statistical wind field model and estimates them to construct the wind energy map. Kolmogorov-Smirnov test, based on TMY(typical meteorological year) wind data of 76 weather station areas, shows that a Log-normal model is adequate for the statistical wind field model. The model is estimated by using the wind speed data of 345,682 regions provided by the National Institute of Meteorological Research(NIMR). Various wind energy statistics are studied under the Log-normal wind field model. As an application, the wind energy density(W$/m^2$) map of South Korea is constructed with a resolution of $1Km{\times}1Km$ and its utility for the wind site analysis is discussed.

The Influence of Low Cost Airline's Flexible Fare Policy on Consumers' Perceptions of Price Fairness (저가항공사의 유동적 요금 전략이 소비자의 가격공정성 지각에 미치는 영향)

  • Hwang, Hee-Joong;Choi, Young-Keun
    • Journal of Distribution Science
    • /
    • v.12 no.10
    • /
    • pp.123-128
    • /
    • 2014
  • Purpose - The purpose of the study is to reexamine the price fairness as practiced by low cost airlines, as a consumer has to experience such inconveniences as inferior airport transportation, extra fees on in-flight meals, and non-negotiable seats, and consumers evaluate such experiences keeping in mind their total costs. This evaluation includes price fairness and allows a reasonable and overall consideration of factors of low cost airlines. It tries to set up a measurement of the indicators consumers' perceptions of price fairness academically as it adapts price fairness to airline services which are renowned for price volatility. Research design, data, and methodology - The research proposes an alternative pricing strategy for the long term profit of low cost airlines after going over conflicts between the traditional theory of consumers' price perception mechanism and flexible fair policy of low cost airlines. It was meaningful when it relates to the early stage of the business, while it enhances the risks relating to the long term survival of low cost airlines. In addition, it is significant as it highlights the negative influences on consumers' perceptions of price fairness, as low cost airlines run on extremely low cost perspectives. Results - The results of the research provide insight into four perspectives, as consumers' perceptions of price fairness are influenced by the frequency and range of price changes and services. The first perspective is that it would lead to positive price evaluation when a low cost airline cuts prices frequently with little changes than one big change. It also would lead to the same result when it comes to necessary services. The second perspective is that one big increase of price would rather undermine the negative aspects of price changes than those of several smaller ones. The third perspective is that additional services would be good to consumers' perceptions of price fairness as compared to discount benefits with respect to the cost. Finally, a low cost airline should consider that consumers will change airlines or defer their flight schedule if the flight fares increase beyond their limits. Conclusions - Low cost airlines should reconsider their pricing policies for services that were provided free earlier. A consumer would not like discount benefits when made to pay for services that were, for long, free of charge. If a low cost airline can provide services with no charge, it should improve volumes if the costs are standardized and, moreover, should consider the charging fees. Alternatively, a consumer can choose between services and fair discount. Low cost airlines are implementing sales promotion strategies, as the competition is more intense than it used to be. In these days, they should regard services over sales promotion, as consumers may prefer to spend money on good premium services. Some differentiation in services could create a good market position for the airlines and, hence, good financial performance.

A Study on the Influence of Servant Leadership in Hotel Organization on the Attitude of Employees (호텔기업의 서번트 리더십이 리더만족과 추가적 노력에 미치는 영향)

  • Yoon, Dae-Gyun;Jang, Byeong-Ju
    • Journal of Global Scholars of Marketing Science
    • /
    • v.16 no.3
    • /
    • pp.107-123
    • /
    • 2006
  • This study suggest a model to find out relationships among the servant leadership as a preceding factor, the trust in higher officers as mediating factors, and leader satisfaction, additional efforts as a resulting factor. Then, empirical study testify the relationship among these factors. This study confined the subjects of empirical analysis to the employees in super-deluxe hotels located in Seoul, Gyeongju, Busan, and Daegu areas. In order to clarify the utility of this study, This study took only hotel employees as the subject of measurement because only hotel organization is able to reveal sensitively the behavioral response between the leader and the members of organization. The preceding study has systematized a basic theory on the servant leadership, and provided factor structure in regard to the servant leadership, but this study has searched the factor structure of the servant leadership with the hotel employees as the subjects of study. Also, from the side of the personnel manager of hotel business, this study can be a criterion for clarifying a leadership program. Especially, in order to cultivate their servant leadership, it is necessary to testify morality and pride as sub-behavioral characteristics of new employees. Also to change the mid-managers' leadership for the effective achievement of the object of organization, this study can be utilized for the development of servant leadership.

  • PDF

Evaluation of convergence Elasticity of Liver Fibroscan used measurement with Ultrasonography (초음파를 이용한 간 섬유화 스캔 검사의 융합 탄성도 측정 평가)

  • Kim, Min-Jeong;Han, Man-Seok;Jang, Jae-Uk
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.5
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this research was to evaluate the clinical and the instrument of convergence utility of transient elastography (FibroScan(R):electromagnetic wave) in diagnosing and treating liver ailments through a comparison and an analysis between liver function blood test and transient elastography (FibroScan(R)) in patients with chronic hepatitis B virus infection. Of all the patients with chronic hepatitis B virus infection who visited clinic B in Daejeon City between July 1, 2015, and February 28, 2016, 75 who underwent a FibroScan(R) test were selected for this study. Their laboratory and liver function test results were compared for a correlation analysis before constructing an ROC (Receiver Operation Characteristic) curve. Aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels were 0.572 and 0.502, respectively, and showed highest correlation with fibrosis score, with statistical significance (p<0.000). Gamma glutamyltranspeptidase, total bilirubin, and alkaline phosphatase levels also showed relatively significant correlations in this order of sequence, while -fetoprotein and total protein levels did not show any statistically significant values. Albumin (-0.449) and platelet levels (-0.373) showed negative correlations with each other and no correlation with fibrosis score (p < 0.000). As liver fibrosis worsened, the accuracy of the ROC curve increased. At the F4 stage, which is the cirrhotic stage, the largest area under the curve was observed. FibroScan(R) showed significant correlation with the ALT (serum glutamic pyruvic transaminase) and AST (serum glutamic oxaloacetic transaminase) levels in the liver function test, which is a routine test for patients with chronic liver ailments. This implies that fibrosis correlates with liver inflammation severity.