• Title/Summary/Keyword: Using IT device

Search Result 6,376, Processing Time 0.036 seconds

Application and Design of Scent Display Device for Head-Mounted Display (HMD용 발향장치 설계와 적용)

  • Baek Yu, Min Ho;Kim, Min Ku;Keum, Dong-Wi;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.52-57
    • /
    • 2019
  • Studies to augment emotion and immersion in multimedia content through olfactory stimulation are being increasingly conducted in the past two decades, and a variety of scent devices have been developed. Most of the scent devices are very large and heavy; consequently, they are installed on a table rather than being attached to the Head-mounted Display (HMD). Even if such devices are mounted on the HMD, it is not possible to control the scent density because of the size limitation, and it is not easy to be immersed in the experience because of the noise caused by the scent device. In order for an actual virtual reality or an augmented reality system to work efficiently with the scent device, three conditions - noiseless, a compact design, and concentration control- must be satisfied. In this study, we design a scent device that satisfies these three conditions. By using a miniature piezoelectric pump, a small size scent device is designed so that it can be easily attached to the lower end of the HMD, and hardly any noise is generated. Moreover, it is possible to control the concentration of the scent by controlling the piezoelectric pump using amplitude and frequency.

Implementation of Augmented Reality Website Using Three.js and React (Three JS와 React를 이용한 증강현실 웹사이트 구현)

  • Kim, Seon-hwa;Moon, Sang-Ho;Lee, Sung-jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.529-531
    • /
    • 2022
  • According to the 2021 Mobile Augmented Reality Market Report by Korea Innovation Foundation, the augmented reality market has been growing recently due to the growth of the mobile augmented reality market along with the development of smartphones. In order to provide augmented reality services to mobile users, it is necessary to create native apps for each device. However, there are problems such as maintenance costs for multi-platform and low accessibility due to app download. Recently, the construction of augmented reality system in a web-based environment by using the WebXR Device API is in progress, but it is judged that the system using the WebXR Device API is still in the research stage. In this paper, a responsive multi-platform environment was built using the WebXR Device API, Three JS, and React, and a function to provide augmented reality service to mobile and web users was implemented. As a result of the experiment, it was confirmed that the interlocking of augmented reality was successfully implemented in a responsive web environment, and look forward to the augmented reality service operating on the web in the future.

  • PDF

Application of Vision Sensor to Communication Device for Person with Serious Disability

  • Tanaka, Motohiro;Yamanaka, Yuki;Moromugi, Shunji;Shimomoto, Youichi;Ohgiya, Yasuhiko;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1634-1637
    • /
    • 2004
  • We developed a communication device for person with serious disability to use slight movement. This device is developed mainly for patients suffering from ALS or a cerebral infarction. They often have communication difficulty because of deterioration of muscle functions. A feature of this device is that slight movements of user's finger, eyes or lips can be detected by using a vision sensor. Due to the features of the vision sensor, it is quite easy even for person with serious disability to use a communication device. By the field test it is confirmed that the vision sensors have superior performances as an input device for communication device. Experiments to use an EMG (electromyography) sensor and a rotary sensor are also tested to compare the performances.

  • PDF

A Study on the Development of Arduino-Electrochemical Cell and the Exploration of Educational Possibilities from the Perspective of Learning by Making

  • Yoon, Jihyun;Cheon, Ji-Hye;Kang, Seong-Joo
    • Journal of the Korean Chemical Society
    • /
    • v.65 no.3
    • /
    • pp.219-229
    • /
    • 2021
  • In this study, the new electrochemical cell device using Arduino and sensor was developed, and experiments of changes in voltage at the time of serial and parallel connection of electrochemical cells were conducted to verify the effectiveness of the device. In addition, in order to examine the educational effects of the device, student's inquiry activities of measuring voltage of electrochemical cells and making objects using the voltage difference were conducted. As a result, it was confirmed that the electrochemical device using Arduino and sensor could not only perform automatic measurements and visualize data but also have a possibility to seek various educational effects through easy coding and modification of the device. Based on the results of students' performance, it was found that experimental activities using the device impart a positive effect not only on the understanding of scientific concepts, but also on the development of the practical ability to apply scientific knowledges to the real life. Educational implications are discussed in terms of 'learning by making'.

Forensic Investigation of External USB Drive (외장형 USB 저장장치의 포렌식 조사방법)

  • Song, Yu-Jin;Lee, Jae-Yong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.4
    • /
    • pp.39-45
    • /
    • 2010
  • Because of portable storage device's technical improvement, it's speeding up the conversion of mass storage. It means it's easier to move and save data. Generally, USB is using for portable storage device and forensic perspective, it's possible us to study data drain through portable storage device under securement of using vestige of USB. If we can secure using vestige of USB from boot domain it's possible to investigate data drain & prove criminal act. This thesis is suggesting Key/Thumb drive & USB Drive Enclosure's confirmation of using or not and division way though Disk Signature analysis.

The Design and Implementation of Frequency Domain Sampling Surface Acoustic Wave Sensor Platform (Frequency Domain Sampling 방식의 Surface Acoustic Wave Sensor Platform 설계 및 구현)

  • Joh, Yool-Hee;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.220-223
    • /
    • 2012
  • Generally, SAW device, which uses Time Domain Sampling, requires high speed AD converter because SAW device (TDS) needs high sampling speed as much as its high data speed. However, the high price of AD converter discourages makers from using it. On the other hand, SAW device, which uses Frequency Domain Sampling, does not required high speed AD converter because SAW device (FDS) does not need high sampling speed. It is very efficient in price comparison to its performance because high processing speed of SAW device (FDS) can be implemented using low price Embedded Systems. The purpose of the thesis is to solve the issues above by designing and realizing SAW device (FDS) using SAW sensor for TDS.

  • PDF

PC Input Device Using Inertial Sensor (관성센서를 이용한 PC 입력장치 개발)

  • Jin, Yong;Lee, Jun-Ho;Park, Chan-Guk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.79-79
    • /
    • 2000
  • In this Paper, the PC input device using MEMS gyros and accelerometer is newly developed, so that it can measure rotation rate and linear acceleration of the human body in space. In General, the human motion has 6 degree of freedom but 2 degree of freedom is enough PC monitor with 2D display. Therefore the simple method is proposed to achieve minimum degree of freedom. It is also applied to the PC mouse. This method can be expanded to the input device for internet set-top box or internet TV.

  • PDF

Development of the slitting device on separation study of pellet and hull (펠릿과 헐의 분리 연구를 위한 슬리팅 장치 개발)

  • 정재후;윤지섭;홍동희;김영환;진재현;박기용
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.236-239
    • /
    • 2003
  • The spent fuel slitting device is an equipment developed in order to feed UO$_2$pellet to the dry pulverizing/mixing device. In this study, we have compared and analyzed the handling method of the slitting and that of the pellet and hull, processing time, separating time for 20kgHM, the number of blades, on the existing slitting device using in DUPIC, and spent fuel management technology research and test facility. Also, we have compared and analyzed about an advantage and weak point, designing and producing, processing, establishment, operation, maintenance about the vertical and horizontal slitting device. Based on these results, we have developed the vertical slitting device. By using the results, we have enhanced the slitting processing time(over 40%)in comparison with DUPIC device, and it will is effectively applied to available data for designing and producing of the hot test facility.

  • PDF

Man-Machine Interface Device for Dismantling Factory

  • Yi, Hwa-Cho;Park, Jung-Whan;Park, Myon Woong;Nam, Taek-Jun
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.248-255
    • /
    • 2017
  • In dismantling factories for recycling, it is important to input actual working data to a personal computer (PC) in order to monitor the work results and related recycling rate of the inputs. This should be performed with a keyboard, a mouse, or other devices. But when a worker is working in the factory, it could be bothersome or time consuming to go to the PC. Especially, workers who works at dismantling factories have a generally low education level are scared to use a PC, which could be used as a pretext for not using the PC. In some cases, data input is performed by a worker after the day's job. In this case, it could take additional time, the worker can make more mistakes, and the data could be unreliable. In this study, we developed a man-machine interface (MMI) device using a safety helmet. A joystick-like device, pushbuttons, and a radio frequency (RF) device for wireless communication is equipped in a safety helmet. This MMI device has functions similar to a PC mouse, and it has a long communication distance. RF is used because it consumes less battery power than Bluetooth. With this MMI device, workers need not go to a PC to input data or to control the PC, and they can control the PC from a long distance. The efficiency of PCs in a factory could be increased by using the developed MMI system, and workers at the dismantling factories could have less reluctance in using the PC.

Effects of NMES and Horseback Riding Using a Robotic Device on the Trunk Muscle Activity and Gross Motor Function in Children with Spastic Diplegia

  • Park, Shin-Jun;Youn, Pong-Sub
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.4
    • /
    • pp.123-128
    • /
    • 2018
  • Purpose: This study examined the effects of neuromuscular electrical stimulation (NMES) and horseback riding using a robotic device on the trunk muscle activity and gross motor function in children with spastic diplegia. Methods: Children with spastic diplegia were divided into two groups: an experimental group (NMES and horseback riding using a robotic device [n=10]) and a control group (placebo NMES and horseback riding using a robotic device [n=10]). Each group received general physical therapy and occupational therapy. Each intervention involved the administration of NMES for 15 minutes and horseback riding using robotic device therapy for 15 minutes three times a week for 4 weeks. The evaluation included both the rectus abdominis muscles (RA), external oblique muscles (EO), thoracic paraspinal muscles (TP), and lumbar paraspinal muscles (LP) activity and GMFM. Results: The RA, EO, TP, and LP muscle activity, GMFM C, D, and E were increased significantly in the experimental and control groups. A significant increase in both the TP muscle activity and GMFM D was observed in the experimental group compared to the control group. Conclusion: This study showed that horseback riding using a robotic device is an effective intervention for trunk muscle activity and GMFM in children with spastic diplegia. However, if NMES is added to the back muscles, it is possible to further increase the thoracic paraspinal muscle activity and standing ability.