• Title/Summary/Keyword: Use of Facility

Search Result 1,742, Processing Time 0.039 seconds

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

Social Network Analysis by Utilizing Disaster Risk Big Data (재난 위험신고 빅데이터를 활용한 사회연결망 분석)

  • Han, Ji-Ah;Jeong, Duk-Hoon
    • The Journal of Bigdata
    • /
    • v.1 no.2
    • /
    • pp.45-63
    • /
    • 2016
  • According to changes of recent climate social structures, frequency of occurrence new or complex disasters are increasing. So the importance of disaster prevention is increasing. To provide useful information of disaster prevention activities, We use the "Safety Sinmungo" main processing practices included Facility safety management in Ministry of Public Safety and Security. Facility safety management is the most and common disaster prevention activities. We identified the keywords in the risk report and facilities to residents report and analyzed the seasonal and inter-regional facilities report distribution process. We also utilized social network analysis techniques to configure a 1-mode, 2-mode facilities around the keyword for differences.

  • PDF

A Study on the Facilities Distribution based on the Choice Model of the Outdoor Leisure-Facilities in a Neighbourhood Unit of the Megalopolis Citizens. -In terms of the Comparison of Choice Models and the Limitations of Use Areas between the Megalopolis- (대도시 주민의 근린옥외여가시설 선택모형을 기초로 한 시설지 배분에 관한 연구)

  • 최기수;김한배;진양교;진상철;허미선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.1
    • /
    • pp.123-139
    • /
    • 1995
  • The megalopolis citizens are reevaluating the expectant value and the perception of leisure aceording to increasing the level of their incomes, The leisure of citizens is increasing in the aspect of quantity and quality of life nowadays In the site planning of leisure, the concrete understanding about people's choice of a leisure site will be the most important thing, not only for the aspect of improvement of the quality of life but also efficiencies of the land use The purposes of chi study are firstly, to find out the factors which are influenced on a choice of Outdoor leisure facilities in neighbourhood unit and to Compare the Characteristics Of Choice models between the three metropolitan areas, secondly, to predict a limitation of use areal according to the change of a needed time based on the metropolitan's standard choice model For the choice model establishment this research used Logit Model which has been used in the field of the traffic, the tourism and the economics. This research made the results which find out the influencing variables with needed times, the accessibility and the percentage of facilities. The lindtations of use areas come out the results which are predicted according to the change of needed times as a most influencing factors. The range of each preferred leisure facility is about 956 meter distant in the neighbourhood park about 644 meter distant in the pocket park about 604 meter distant in the recreation center, about 628 meter distant in the tennis court about 974 meter distant in the private hob by facility and about 528 meter distant in the library from the apartment unit The recreation center and the library are nearer facilities than the other facilities. But these facilities are surveyed to be more or less influenced by an interesting progran, a context of events and the level of useful facilities, etc.

  • PDF

Evidence Based Practice in Long Term Care Settings

  • Specht, Janet K.
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.2
    • /
    • pp.145-153
    • /
    • 2013
  • Purpose: The purpose of this manuscript is to discuss the need for use of evidence based practice (EBP) in LTC, the current use of evidence in long term care facilities and what we know about adoption of the use of EBP in LTC. Methods: Literature review and reporting of findings from the M-TRAIN study that was a quasi-experimental design to test the effectiveness of an intervention to increase the use of EBPs for urinary incontinence and pain in 48 LTC facilities. Results: Barriers to adopting EBPs include lack of available time, lack of access to current research literature, limited critical appraisal skills, excessive literature to review, non-receptive organizational culture, limited resources, and limited decision-making authority of staff to implement change. Strategies to promote adoption of EBP include the commitment of management; the culture of the home; leadership; staff knowledge, time, and reward; and facility size, complexity, the extent that members are involved outside the facility, NH chain membership, and high level of private pay residents. Findings from the M-TRAIN add, stability of nurse leader and congruency between the leaders perception of their leadership and the staff's perception of the leadership. Conclusion: There is clear evidence of the need and the benefits to residents of LTC and to the health care system yet adoption of EBP continues to be slow and sporadic. There is also evidence for the process of establishing best evidence and many resources to find the available EBPs. The urgent need now is finding ways to best get the EBPs implemented in LTC. There is growing evidence about best methods to do this but continued research is needed. Clearly, residents in LTC deserve the best care possible and EBPs represent an important vehicle by which to do this.

Servey and Analysis of Use Behavior in Children's Parks - Focused on Housing Development Area in Daegu - (어린이공원 이용행태 조사.분석 - 대구광역시 택지개발지구를 중심으로 -)

  • Kim Yong-Soo;Lee Dong-Hun;Park Chan-Yong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.3 s.116
    • /
    • pp.32-40
    • /
    • 2006
  • We investigated space establishment and land use of children's parks by studying movement of users in and out of the parks with a questionnaire survey, video and analysis, and then analyzed the characteristics of how the facilities and the space of the parte are used. The results are as follows. First, when considering the character of the facilities of children's parks, entertainment facilities should receive priority followed by those for relaxation and those for convenience. When considering the position of facilities in the parks, because activity spaces may have similar functions to multi-purpose paved spaces, common use of these two spaces should be considered. Entrances and lines of movement should be kept in mind. Second, when considering the surrounding land uses, in case a play facility at a large-sized complex or an elementary school is adjacent, the exercise facilities may be more important, followed by play and rest facilities. In case there is a broad path around the parte, the way in which movement occurs into the central axis should be considered so that the other side of the broad way is not included in the children's play space. Third, proper control of roads adjacent to the parse is needed to protect children from danger.

Meta-heuristic Method for the Single Source Capacitated Facility Location Problem (물류 센터 위치 선정 및 대리점 할당 모형에 대한 휴리스틱 해법)

  • Soak, Sang-Moon;Lee, Sang-Wook
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.107-116
    • /
    • 2010
  • The facility location problem is one of the traditional optimization problems. In this paper, we deal with the single source capacitated facility location problem (SSCFLP) and it is known as an NP-hard problem. Thus, it seems to be natural to use a heuristic approach such as evolutionary algorithms for solving the SSCFLP. This paper introduces a new efficient evolutionary algorithm for the SSCFLP. The proposed algorithm is devised by incorporating a general adaptive link adjustment evolutionary algorithm and three heuristic local search methods. Finally we compare the proposed algorithm with the previous algorithms and show the proposed algorithm finds optimum solutions at almost all middle size test instances and very stable solutions at larger size test instances.

Design considerations for teleoperation systems operating in gas-tight argon cells

  • Yu, Seungnam;Lee, Jongkwang;Park, Byungsuk;Cho, Ilje;Lee, Hyojik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1717-1726
    • /
    • 2017
  • In the nuclear industry, mechanical engineers spend a significant portion of their time designing equipment such as manipulators, bogies, mechanical grippers, and so on. Some customized designs can be considered as standard mechanical equipment in this area, although it is not unusual to find that an existing design cannot simply be copied from one project to another. Varied performance requirements can dictate that redesign, often quite extensive redesign, is required. However, if something similar has been done before, engineers could use that as a starting point for the new project. In this regard, this study presents several guidelines inspired by previous design knowledge for similar development cases. Moreover, this study presents more detailed suggestions such as design guidelines for an argon-based hot cell atmosphere and design experience for a large-scale practical hot cell facility. Design considerations and case studies dealt with in this study are dedicated to teleoperation manipulators that are used at a large-scale argon cell facility for pyroprocess integrated inactive demonstration (PRIDE), at the Korea Atomic Energy Research Institute. In particular, for case studies to support the suggested recommendations, a fabricated telemanipulator system for PRIDE is introduced, and several kinds of experimental results associated with it are presented.

Evaluation of the Volume and Pollutant Reduction in an Infiltration and Filtration Facility with Varying Rainfall Conditions (침투여과시설의 강우계급에 따른 유량 및 비점오염물질 저감 효과 분석)

  • Yu, Gigyung;Choi, Jiyeon;Kang, Hee-Man;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.1
    • /
    • pp.30-35
    • /
    • 2016
  • Urban areas generate large amounts of stormwater and non-point source (NPS) pollutants during rainfall events. These are caused by various land use runoffs, vehicular and human activities and increased impervious cover. The increased runoff and NPS pollutants cause water quality deterioration in the receiving waters and adversely affect the aqua-ecosystem. These environmental impacts could be reduced through the application of low impact development (LID) techniques. In Korea, more than 80% of the total rainfall occurs in summer and most of these were 10 mm or less. Therefore, if the LIDs developed were able to cope with rainfall of 10 mm and below, NPS management could be efficiently conducted. This research was performed to determine the effect of varying amounts of rainfall on the performance capability of an established infiltration and filtration facility (IF facility) that can be applied to Korea's common rainfall ranges. The IF facility area was 1.75% of the catchment area, however the facility treated more than 40% and 60% runoff volume and pollutant reduction respectively for a 10 mm rainfall. Lastly, higher volume and pollutant reduction could be attained when the LID area was at least 2% of the entire catchment.

A Comparative Study on Space Organization of Elementary School in Korea and Japan (한·일 초등학교의 공간구성 실태 비교)

  • Choi, Hyeong Ju;Cho, Jin Il;Park, Hee Won
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.12 no.3
    • /
    • pp.11-25
    • /
    • 2013
  • This study aims on finding a direction of desirable space organization of future elementary school in Korea by analyzing current status of space organization of elementary school in Japan. In this study comparison and analysis of curriculum of Korea and Japan, facility standards on national level and standards of national subsidy, current status of number of schools and students, transition of changes in facility area of elementary school for last 10 years are included. In Korea and Japan each 7 elementary schools which were constructed after 2007 and are good in space organization and school planning are selected. The comparison and analysis of satisfaction level on physical educational conditions and facilities such as current status of space organization and how to use them are conducted in this study. The contents of analyzing space organization are 'entry and placement, outdoor space', 'space program' and 'phase structure and organization of unit space'.

준설퇴적토의 현장처분시설(Confined Disposal Facility) 설계

  • 홍준식;안재환;기소정;지재성;배우근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.355-358
    • /
    • 2002
  • A sediments are Integral called as gravel, sand, clay, mineral materials which are settling in bottom layer of reservoir, stream, and oceans from land. In practical problems relations of sediments are flood by decreed of flow capacity and down of water quality. Dredged sediments are composed with constructed material and variety of pollutant compounds. Therefore, it is very much of cost effects in nationally, if development for use of constructed material separated only constructed material within sediments. And it will be continue to the dredge operation of stream sediment for retrofit of water environment and sustainable's after the years. The following results could be obtained : In case of high concentration sediments, sample for design of CDF was shown property of flocculent settling. Assuming that average inflow rate is 1, 000㎥/hr, mean residence time( $T_{d}$), average ponding depth( $H_{pd}$ ), and design surface area for flocculent settling( $A_{df}$ ) were 5 hr, 0.6m, and 15, 750 $m^2$ respectivelyrespectivelyy

  • PDF