• Title/Summary/Keyword: Use of Facility

Search Result 1,738, Processing Time 0.024 seconds

A Study on the Recognition Characteristics of the High School Students in Seoul about the Factors Influencing the Land Value (지가 형성 요인에 대한 서울시 고등학생들의 인식 특성 연구)

  • Shin, Yeong-Jae
    • Journal of the Korean association of regional geographers
    • /
    • v.16 no.1
    • /
    • pp.59-75
    • /
    • 2010
  • This study analyzed on the recognition characteristics of high school students in Seoul about the factors influencing the land value. The results are as follows; First, when the factors influencing the land value was divided into 'the factors related with the publicly assessed land value' and 'the unrelated factors.' Students recognized that the former had more influence on the land value than the latter. Second, students recognized that 'the relative factors of land' had more influence on the land value than 'the absolute factors of land'. Third, as a result of checking how much five evaluation criterions influence on the recognition characteristics about the factors influencing the land value, the distance to major facilities had the most influence on the recognition, while the situation of land use had the weakest one. Among 13 factors, the distance from the convenience facilities was most influential and the shape of the land was least influential. Fourth, there was a gap between recognition of choosing the highest land value areas and the lowest land value areas and recognition of degree that the factor influencing the land value had an effect on the land value. Lastly, when the result of recognition about factors influencing the land value and the land value ranking was compared with the result of the co-relation between the land value and factors influencing the land value of the real region, either similar or different results were shown.

  • PDF

The Effect of Roofing Materials for Using Harvested Rainwater (집수빗물이용을 위한 지붕면 재질의 영향)

  • Lee, Ju Young;Kim, Tschung-Il;Kim, Hyunwoo;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.623-629
    • /
    • 2012
  • The objective was to evaluate the quality of harvested rainwater of the roofing materials used and the presence of lichens/mosses on the roofing surface. This experiment was studied in the field where five pilot structures with different roofing materials (i.e., wooden shingle tiles, wooden shingle tiles (including mosses), concrete tiles, clay tiles [Gi-Wa] and slate tiles) were installed. As a result, the clay tiles [Gi-Wa] was found to be the most suitable for rainwater harvesting applications. It was due to the disinfection from ultraviolet light and high temperature according to characteristic of roofing materials. Comparison with quality of rainwater on that wooden shingle tiles with and without including mosses, which may affect the concentration of and wooden shingle tiles including mosses, mosses may affect concentration of TOC, nitrate, and sulfate. Additionally, the average concentration of asbestos was determined to be measured at $0.002/cm^3$ for the slate tiles. The value satisfied with it met the Ministry of Environment's Multi-use facility standard and Ministry of Labor's Office standard ($0.01/cm^3$).

Evaluation of SO2 Absorption Efficiency for Calcined Oyster Shell Slurry Using a Simulated Spray Type-flue Gas Desulfurization (FGD) System: A Comparative Study with Limestone Slurry (모사 Spray Type 배연탈황설비를 이용한 소성패각 슬러리의 SO2 흡수능 평가: 석회석과의 비교연구)

  • Kim, Seok-Hwi;Hong, Bum-Uh;Lee, Jin-Won;Cha, Wang-Seok;Kim, Kangjoo;Moon, Bo-Kyung
    • Economic and Environmental Geology
    • /
    • v.52 no.2
    • /
    • pp.119-128
    • /
    • 2019
  • About 300,000 tones of oyster shell are annually produced in Korea and, thus, a massive recycling plan is required. Many desulfurizing studies using oyster shells with chemical composition of $CaCO_3$ have been performed so far; however, most of them have focused on dry desulfurization. This study investigates the possibility of using oyster shells for wet desulfurization after calcination. For this, a simulated wet desulfurization facility of spray type was devised and compared the SOx-stripping characteristics of calcined oyster shell with those of limestone. The calcined oyster shell slurry indicate a better desulfurizability than the slurries of raw shell or limestone because the oyster shell transformed to a more reactive phase ($Ca(OH)_2$) by the calcination and hydration. Because of this reason, when the calcined oyster shell slurries were used, the reaction residue showed the higher gypsum ($CaSO_4{\cdot}2H_2O$) contents than any other cases. In the continuous desulfurization experiments, calcined oyster shell slurry showed a wider pH variation than limestone or raw oyster shell slurries, another clear indication of high reactivity of calcined oyster shells for $SO_2$ absorption. Our study also shows that the efficiency of wet desulfurization can be improved by the use of calcined oyster shells.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Results of the Field Investigation (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(I): 도시가스 및 수송용 - 현장조사 결과 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.1
    • /
    • pp.77-85
    • /
    • 2019
  • Biogasification is a technology that uses organic wastes to reproduce as environmental fuels containing methane gas. Biogasification has attracted worldwide attention because it can produce renewable-energy and stable land treatment with prohibit from landfilling and ocean dumping of organic waste. Biomethane is produced by refining biogas. It is injected into natural gas pipeline or used transportation fuel such as cars and buses. 90 bio-gasification facilities are operating in 2016, and methane gas production is very low due to it is limited to organic wastes such as food waste, animal manure, and sewage sludge. There are seven domestic biomethane manufacturing facilities, and the use of high value-added such as transport fuels and city-gas through upgrading biogas should be expanded. On the other hand, the rapid biogasification of organic wastes in domestic resulted in frequent breakdowns of facilities and low efficiency problems. Therefore, the problem is improving as technical guidance, design and operational technical guidance is developed and field experience is accumulated. However, while improvements in biogas production are being made, there is a problem with low utilization. In this study, the problems of biomethane manufacturing facilities were identified in order to optimize the production and utilization of biogas from organic waste resources. Also, in order to present the design and operation guideline of the gas pretreatment and the upgrading process, we will investigate precision monitoring, energy balance and economic analysis and solutions for on-site problems by facility.

A Study of Maintenance Method by Monitoring and Evaluation of Water Friendly Facilitiesin Urban Streams - A Case Study of Jeonjucheon in Jeonju-si - (하천친수시설의 모니터링과 평가를 통한 유지관리방안 연구 - 전주천을 중심으로 -)

  • Lim, Hyunjeong;Jeong, Moonsun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.263-274
    • /
    • 2019
  • The purpose of this study is to examine a monitoring method, management zones, and maintenance strategies for water friendly facilities in urban streams after the completion of ecological restoration projects. Maintenance monitoring items are composed of 'use space& facilities', 'trails& bike roads', 'access', and 'boards'. The evaluation standards of water friendly facilities are 'maintenance conditions', 'safety', and 'usage level' which are rated as 'good', 'moderate', and 'poor'. Through a field survey and evaluation of 15 stream sections in Jeonjucheon,the management levels of each water friendly facility are determined as 'priority maintenance', 'general maintenance', 'maintain/remove', and 'remove'. Based on the evaluation results, management zones and maintenance strategies are proposed for each stream section. As a results, the stream sections of J2, J3, J4, and J9 which have 5 to 9 facilities with 'priority maintenance' are determined as 'intensive management zone'. The stream sections of J5, J6, J7, J8, J11, and J14 which have 1 to 3 facilities with 'priority maintenance' are determined as 'regular management zone'. The stream sections of J1, J10, J12, J13, and J15 which have no facilities with 'priority maintenance' are determined as 'minimum management zone'. The process of monitoring & evaluation system and determining management zones can be applied to establish a systematic maintenance plan for water friendly facilities by participation of governance in the future.

A Design Aspects of Historic Parks Preserving Buried Cultural Heritages - In the Case of Neunggok Prehistoric Remains Park, Ansan Singil Historic Park, Yongjuk Historic Park - (매장문화재 보존형 역사공원의 설계 양상 - 능곡선사유적공원, 안산신길역사공원, 용죽역사공원을 대상으로 -)

  • Kim, Ki-Uk;So, Hyun-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.12-22
    • /
    • 2019
  • This study derived the design aspects by carrying out the case study of Neunggok prehistoric remains park, Ansansingil historic park and Yongjuk historic park to which are taken measures to preserve undesignated cultural heritages after studying the related laws & regulations and the systems as the design conditions of historic park preserving buried cultural heritages. The results of the study are as follows. First, according to the laws & regulations related to the historical parks, the historic sites should be preserved and utilized at the same time and can have history-related facility spaces, squares, rest spaces, exercise spaces, education & culture space, and convenience spaces. Second, by the space organization and the circulation system emphasizing only the preservation of buried cultural heritages, the feature-preservation space and the functional space are separated and due to not accepting the usage behavior considering peripheral land use, the effectiveness of the historical park was low. Third, the passive feature-preservation methods such as the preservation of the exposed site in architectural methods, the reproduction of the dugout hut, and the planting Royal azaleas or displaying stone after covering up the location of the pit dwellings with soil and the usage mainly for viewing have weakened the identity of the historical park. Fourth, the fence preventing users' access interferes experiencing the features, and the vertical structure protecting the upper part of the exposed features has overwhelmed the landscape of the historical parks. Fifth, it was difficult to figure out the feature space only by the texts mainly on terminologies and the excavation photographs presented on the information signs which introduce the buried cultural heritages.

Basic Economic Analysis for Co-production Process of DME and Electricity using Syngas Obtained by Coal Gasification (석탄 가스화를 통한 전력 생산과 DME 병산 공정에 대한 기초 경제성 분석)

  • Yoo, Young Don;Kim, Su Hyun;Cho, Wonjun;Mo, Yonggi;Song, Taekyong
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.796-806
    • /
    • 2014
  • The key for the commercial deployment of IGCC power plants or chemical (methanol, dimethyl ether, etc.) production plants based on coal gasification is their economic advantage over plants producing electricity or chemicals from crude oil or natural gas. The better economy of coal gasification based plants can be obtained by co-production of electricity and chemicals. In this study, we carried out the economic feasibility analysis on the process of co-producing electricity and DME (dimethyl ether) using coal gasification. The plant's capacity was 250 MW electric and DME production of 300,000 ton per year. Assuming that the sales price of DME is 500,000 won/ton, the production cost of electricity is in the range of 33~58% of 150.69 won/kwh which is the average of SMP (system marginal price) in 2013, Korea. At present, the sales price of DME in China is approximately 900,000 won/ton. Therefore, there are more potential for lowering the price of co-produced electricity when comparing that from IGCC only. Since the co-production system can not only use the coal gasifier and the gas purification process as a common facility but also can control production rates of electricity and DME depending on the market demand, the production cost of electricity and DME can be significantly reduced compared to the process of producing electricity or DME separately.

Implementation of Rule Management System for Validating Spatial Object Integrity (공간 객체 무결성 검증을 위한 규칙 관리 시스템의 구현)

  • Go, Goeng-Uk;Yu, Sang-Bong;Kim, Gi-Chang;Cha, Sang-Gyun
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.12
    • /
    • pp.1393-1403
    • /
    • 1999
  • 공간 데이타베이스 시스템을 통하여 공유되는 공간 데이타는 무결성이 적절하게 유지되지 않는 한 전체 응용 시스템의 행위를 예측할 수 없게 되므로 데이타의 무결성 확인 및 유지는 필수적이다. 특히 공공 GIS에 저장된 공간 데이타는 토지 이용도 평가, 도시 계획, 자원 관리, 시설물 관리, 안전 관리, 국방 등 국가 전체 및 지역의 중요한 정책 결정을 위한 다양한 응용 시스템들에 의해 이용되므로 적절한 공간 객체의 무결성 확인이 더욱 더 필요하다. 본 논문에서는 능동(active) DBMS의 능동 규칙(active rule) 기법을 이용하여 공간 객체의 무결성 확인을 지원하기 위한 규칙 관리 시스템을 제시한다. 능동 규칙을 이용한 공간 객체의 무결성 확인은 응용 프로그래머를 무결성 확인에 대한 부담으로부터 자유롭게 할 수 있다. 본 시스템은 특정 DBMS에 종속되지 않는 독립적인 외부 시스템으로 존재하며, 능동 규칙 관리기, 규칙 베이스, 그리고 활성규칙 생성기의 3 부분으로 구성된다. 사용자가 공간 데이타베이스 응용 프로그램을 통해 공간 객체를 조작하고자 할 때, 본 시스템은 데이타베이스 트랜잭션을 단위로 조작되는 모든 공간 객체의 무결성 확인을 위해 응용 프로그램에 삽입될 무결성 제약조건 규칙들을 효율적으로 관리하는 역할을 한다.Abstract It is necessary that the integrity of spatial data shared through the spatial database system is validated and appropriately maintained, otherwise the activity of whole application system is unpredictable. Specially, the integrity of spatial data stored in public GIS has to be validated, because those data are used by various applications which make a decision on an important policy of the region and/or whole nation such as evaluation of land use, city planning, resource management, facility management, risk management/safety supervision, national defense. In this paper, we propose rule management system to support validating the integrity of spatial object, using the technique of active rule technique from active DBMS. Validating data integrity using active rules allows database application programmer to be free from a burden on validation of the data integrity. This system is an independent, external system that is not subject to specific DBMS and consists of three parts, which are the active rule manager, the rule base, and the triggered rule generator. When an user tries to manipulate spatial objects through a spatial database application program, this system serves to efficiently manage integrity rules to be inserted into the application program to validate the integrity constraints of all the spatial objects manipulated by database transactions.

Visualization and contamination analysis for groundwater quality of CDEWSF in Gwangju area using statistical method (통계적 기법을 이용한 광주지역 민방위비상급수용 지하수 수질 오염도 분석 및 시각화 연구)

  • Jang, Seoeun;Lee, Daehaeng;Kim, Jongmin;Kim, Haram;Jeong, Sukkyung;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.122-133
    • /
    • 2018
  • In this study, groundwater quality data measured for 11 years from 2006 to 2016 were analyzed statistically for 101 civil defense emergency water supply facilities (CDEWSF) in the Gwangju area. The contamination level was quantified into four grades by using excess drinking water quality standards, average concentration analysis, and tendency analysis results for each facility. On the basis of this approach, the groundwater contamination degree of each item was evaluated according to land use status, installation year, depth, and geological distribution. The contamination grade ratios, which were obtained by analyzing three contamination indicators (water quality exceeded frequency, average concentration analysis, and trend analysis) for 15 items on statistically significant of civil defense emergency water was relatively high, in the order of Turbidity (51.5 %) > Color (32.7 %) > Nitrate nitrogen (28.7 %) > Hardness (25.7 %). As a result of the contamination grade analysis, except for the items of Turbidity, Color, and Nitrate nitrogen, the contamination levels were distributed in various degrees from "clean (0)" to "seriously contaminated (3)." Regarding the contamination grade of 12 items, 25 % of the total were classified as "possibly contaminated (1)," and 75 % were rated "clean (0)." The four items (Turbidity, Color, Nitrate nitrogen, and Hardness) for which contamination indication rate were evaluated as "high" by the were visualized on a contamination map.

Dosimetric Characteristics of the KCCH Neutron Therapy Facility (원자력병원 중성자선치료기의 물리적특성)

  • Yoo Seong Yul;Noh Sung Woo;Chung Hyun Woo;Cho Chul Koo;Koh Kyoung Hwan;Bak Joo Shik;Eenmaa Juri
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.85-91
    • /
    • 1988
  • For the physical characterization of neutron beam, dosimetric measurements had been performed to obtain physical data of KCCH cyclotron-produced neutrons for clinical use. The results are presented and compared with the data of other institutions from the literatures. The central axis percent depth dose, build-up curves and open and wedge isodose curve values are intermediate between that of a 4 and 6 MV X-rays. The build-up level of maximum dose was at 1.35cm and entrance dose was approximately $40\%$. Flatness of the beam was $9\%$ at Dmax and less $than{\pm}3\%$ at the depth of $80\%$ isodose line. Penumbra begond the $20\%$ line is wider than corresponding photon beam. The output factors ranged 0.894 for $6\times6cm$ field to 1.187 for $30\times30cm$ field. Gamma contamination of neutron beam was $4.9\%$ at 2 cm depth in $10\times10cm$ field.

  • PDF