• Title/Summary/Keyword: Use of Facility

Search Result 1,738, Processing Time 0.023 seconds

Sign system design for rapid evacuation in earthquake evacuation situations (지진발생 상황에서 신속한 대피를 돕는 사인시스템 디자인)

  • Yoo, Ga-hee;Oh, Kwang-myung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.107-112
    • /
    • 2019
  • Most of the sign systems involved in evacuation are not useful in seismic situations where people have to evacuate with their heads bowed, given that they are at the top of the wall. Based on the analysis and understanding of seismic evacuation situations, this study proposes a sign system as a measure for rapid seismic evacuation. First, understand the seismic situation based on the video analysis of the earthquake evacuation situation. Second, the need for a sign system to help secure evacuation in earthquake situations was derived. Third, the on-site survey examined the suitability of the Sine system installed in Korea as an escape facility for the earthquake evacuation situation. Based on the video analysis and on-site survey, it was concluded that the installation of escape guidance lamps alone could not induce rapid evacuation in the earthquake situation. In this study, a sign system is proposed to help the use of doors by installing a sign system near an emergency exit light.

Integrated Management System to Improve Photovoltaic Operation Efficiency (태양광발전 운영효율 향상을 위한 통합관리시스템)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.113-118
    • /
    • 2019
  • A solar power plant is a facility that produces electricity. As the risk of fire and electric shock accidents is diversified, the risk of workers, surrounding people, and facilities is increased, preventing safety accidents and promptly responding to safety accidents Is emerging. In light of the necessity of such development, it is necessary to develop a solar power generation management system that can diagnose and maintain the problems of the power generation system in real time by developing technologies for collecting and analyzing the data produced by the solar power generation system As a result, the utilization rate and the maintenance cost can be reduced. In order to do this, it is necessary to accurately predict the solar power generation amount in the present state, to diagnose the abnormality of the current power generation state and to grasp the abnormal position, and to use the model considering economical efficiency when the abnormal position is grasped, And the time and other information should be provided.

Heating Transferring Charcteristics of Cement Mortar Block with Waste CNT and Conduction Activator (폐CNT와 전도촉진재를 혼입한 시멘트 모르타르 블록의 발열 전도 특성)

  • Koo, Hounchul;Kim, Woon-Hak;Oh, Hongseob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.2
    • /
    • pp.176-183
    • /
    • 2022
  • High-purity waste CNTs were mixed into cement mortar to manufacture heat-generating concrete that can use low voltage power, and carbon fiber and waste cathode materials were also used improve the conductivity of the mortar. The waste CNTs were analyzed to have a high concentration of multi-walled CNTs, and substituted liquid type waste CNTs were used during mortar mixing in order to increase dispersibility. The temperature change of the mortar with CNT was evaluated when using electric power below DC 24 V in order to utilize a small self-generation facility such as small solar power module when the mortar heats up and to minimize electromagnetic waves. When liquid-type waste CNTs were applied and a voltage of DC 24 V was introduced, it rose to 60 ℃ in a 200 × 100 × 50 mm mortar block specimen. The field applicability of self heating mortar with waste CNT was sufficient and also the amount of change in heat energy in mortar with liquid type waste CNT, carbon fiber and waste cathode materials is more effective compared to it of other variables.

Measurement and Analysis of Indoor Environment in Emergency Switching Type Temporary Negative Pressure Isolation Ward that Use Portable Negative Pressure Units (이동형 음압기를 적용한 긴급 전환형 임시음압격리병실의 실내 환경 측정 분석)

  • Lee, Wonseok;Lee, Sejin;Kim, Heegang;Yeo, Myoungsouk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.89-97
    • /
    • 2022
  • Purpose: Because of the recent COVID-19 pandemic, there have been many cases of using portable negative pressure unit to convert general wards into temporary negative pressure isolation wards. The purpose of this study is to analyze the indoor environment of the switching type wards. Methods: Field measurements and experiments were conducted in a medical facility. Air volume, wind speed and pressure difference were measured in non-occupant state. Dispersion tests were performed with gas and particle matter. Results: The pressure difference between the wards and the corridor was higher than -2.5 Pa in normal situation. However, in the gas and particle dispersion tests, it was found that there were concerns about the spread through leakages in low-airtight walls or ceilings. In addition, it was confirmed that the pressure imbalance in ducts through the non-sealed diffusers could cause back flow during portable unit operation. Furthermore, when there was a pressure difference between adjacent wards planned to be at same pressure level, the possibility of the spread through the leakages was found. Implications: When using portable units for making switching type wards, it is necessary to create airtight space and seal the non-operation diffusers. In case of operating the air handling unit, T.A.B must be performed to adjust the duct balancing.

A Study on Slope Reinforcing Effects Using Soil Stabilizer (토사안정제를 이용한 비탈면보강 효과에 관한 연구)

  • Kim, Ki-Hwan;Kim, Yu-Tae;Lee, Seung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.10
    • /
    • pp.5-14
    • /
    • 2010
  • The slope stability method using the soil stabilizer is a way to ensure that the slope stability from reinforcing method is environmentally friendly. However, the reinforcing method does not ensure slope stability for lack of research on the reinforcement effect of the mixture with soil. So the application of this method implies difficult technical issues. In this research, reinforcement effect is investigated according to the different ratio of mixture. And the optimum reinforcement depth is proposed according to the height of slope from numerical analysis. The results show that approximately the soil strength increases from two to three times. From numerical analysis, it is possible to estimate the optimum height according to the height of slope. It is anticipated that the use of soil stabilizer will increase the slope stability.

A Study on Residents' Attitude Toward the Development and Management of Jirisan Dulegil (지리산둘레길 조성과 운영 관련 지역주민 태도에 관한 연구)

  • Yoo, Ki-Joon
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.3
    • /
    • pp.374-380
    • /
    • 2014
  • This study was conducted to provide baseline information which will be useful for managing the forest trails as the outdoor recreation facility. To investigate residents' attitudes toward the forest trail construction and use, a questionnaire survey was employed in Jirisan Dulegil. As the results, 4 impact factors that are influenced to local communities due to Jirisan Dulegil construction were resulted in. Most of the respondents perceived that the Jirisan Dulegil have positive impact economically on community growth. Contrastively, a negative perception existed in the environmental aspect. Local lodging industry was selected one of preference business models. In viewpoint of community business, a more professional and systematic approach to find appropriate business model is needed because of structural vulnerability of business.

Development of Real-time Process Management System for improving safety of Shop Floor (생산현장의 안전성 향상을 위한 실시간 공정관리 시스템 개발)

  • Lee, Seung Woo;Nam, So Jeong;Lee, Jai Kyung;Lee, Hwa Ki
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.171-178
    • /
    • 2013
  • Workers are avoiding production/manufacturing sites due to the poor working environment and concern over safety. Small and medium-sized businesses introduce new equipment to secure safety in the production site or ensure effective process management by introducing the real-time monitoring technique for existing equipment. The importance of real-time monitoring of equipment and process in the production site can also be found in the ANSI/ISA-195 model. Note, however, that most production sites still use paper-based work slip as a process management technique. Data reliability may deteriorate because information on the present condition of the production site cannot be collected/analyzed properly due to manual data writing by the worker. This paper introduces the monitoring and process management technique based on a direct facility interface to secure safety in the field by improving the poor working environment and enhance there liability and real-time characteristics of the production data. Since the data is collected from equipment in real-time directly through the SIB-based interface and PLC-based interface, problems associated with workers' manual data input are expected to be solved; safety can also be improved by enhancing workers' attention to work by minimizing workers' injuries and disruption.

A Study on the Friction Loss Reduction in Fire Hoses Used at a Fire Scene (화재현장에서 사용하는 소방호스의 마찰손실 감소 방안에 관한 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.52-59
    • /
    • 2013
  • It was described the measured friction loss depending on pressure used and changes in water flow rates for a fire hose used at a fire scene on this study. As a result of actual measurement based on the result obtained by analyzing the use situation of a fire hose such as the kind, quantity, pressure used, etc. of a fire hose, the friction loss in a fire hose under the condition of using by a fire officer at a fire scene was measured as up to 56.8 %. This is much different from the equivalent length of a fire hose used to calculate the pump head in an indoor and outdoor fire-fighting facility. There is no related restrictive regulation on friction loss, there are even no data on friction loss measured by fire hose makers, and spreading a fire hose without considering friction loss at a fire scene can result in an increased length of hose used and a high-pressure water discharge from a fire engine, so this study aims to establish a standard for an equivalent length to friction loss in a fire hose and to propose a spreading method considering friction loss in a fire hose at a fire scene.

A study on the Site Selection of Transformer Substation Using GIS (GIS기법을 이용한 변전소 위치 선정에 관한 연구)

  • Yun, Kong-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.14 no.1 s.35
    • /
    • pp.29-36
    • /
    • 2006
  • In the process of location selection, it is assumed that transformer substation socially recognized as a dangerous facility require especially more rigorous and resonable process. This paper implements suitability analysis for optimum location selection of transformer substation in southern Gyeonggi province using AHP(Analytic Hierarchy Process) and spatial analysis of GIS in terms of safety, national land use, economical efficiency and environment preservation. To do this, necessary data from 1/5,000 digital map are extracted a s raster format for suitability analysis and a field investigation also was done. In the procedure of site selection, three candidate zones with 1.5km radius were selected for the whole research area and then through field survey low transformer sites were selected from candidate zones. In the last the appropriateness of selected sites was evaluated. The results of the suitability analysis showed that the first candidate site satisfied the location condition best and other candidate sites generally showed good location condition.

  • PDF

A study on driver experience to railway crossings in driving simulator (차량 시뮬레이터를 이용한 철도건널목 운전행태에 관한 연구)

  • Kim, Inhi;Lee, Seonha
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.2
    • /
    • pp.57-67
    • /
    • 2014
  • In the last decade, various situations were simulated through virtual environment due to rapid improvement of computer capability and technology. Transportation engineering also has adopted the virtual environment facility in order to identify drivers behaviour under various circumstances. This study aims to evaluate driver reactions to the introduction of new ITS interventions at railway crossings (RLX) in driving simulator. Three ITS safety devices were used to figure out how drivers reacted to them. In addition, a survey was conducted to find participants' work load and acceptance of the technology. The ultimate purpose of this paper is to evaluate ITS safety devices in various aspects. Each participant made 3 runs (2 baselines, 1 ITS randomly) for approximately 20 minutes each. The participants answered that current railway crossings did not look safe prior to experiment. They responded that the use of ITS technologies were easy and the technologies were more effective on passive railway crossings.