• Title/Summary/Keyword: Urine test

검색결과 510건 처리시간 0.031초

요로감염소아의 오줌에서 분리한 대장균 K1 다당류 항원의 동정 (Identification of K1 Polysaccharide Antigen of Escherichia coli Isolates from Urine Specimens of Urinary Tract Infections in Children)

  • 정희곤
    • 한국식품영양학회지
    • /
    • 제11권4호
    • /
    • pp.416-419
    • /
    • 1998
  • Identification of escherchia coli K1 polysaccharide antigen isolated from urine specimens of urinary tract infections in children were performed from of 1992 to 1993 in Kyoto, Japan. The serotypes of E. coli were categorized that O1:H7, O2:H6, O2:H7, O16:H6, O18:H7, O18:H ̄, and O135:H44 among 14 strains isolated from urine specimens of urinary tract infections in children by the serological test. And, one strain (O18:H ̄, isolation rate: 7.1%) of E. coli K1 polysaccharide antigen among 14 strains were isolated from urine specimens of urinary tract infections in children by the bacteriophage test.

  • PDF

노인여성을 위한 요실금 팬티 개발에 관한 연구 (A Study of the Developement of Washable Panties for Elderly Women of Incontinence Urine)

  • 조진숙;최진희;허은영
    • 한국의류학회지
    • /
    • 제25권5호
    • /
    • pp.856-867
    • /
    • 2001
  • The purpose of this study was to develop washable panties for elderly women of incontinence urine. We carried out a questionnaire survey in order to find out what are the inconvenience of incontinence. Also we analyse the properties of incontinence panties available in silver market. Then we did wearing test of the existing continence panties to 40 subjects. Having done the wearing test, it was clear that the composit and the size of the absorbing layers must be crucial points of the development of the prototype panty. The prototype was designed to improve absorbing speed as well as capability without sacrificing of wearing comfort. The developed prototype panty went through wearing test and property tests to assure the design. The results are as follows:- 1. Absorbing capability as a whole, quick absorbance at the moment of passing of urine, the touch of the cover layer after quick absorbance and deodorant property were improved than existing incontinence panties. 2. The size and the dimensions of each part, specially absorbing layers at the crotch area, were remarkably improved.

  • PDF

도축돈의 혈청, 뇨 및 근육에서 sulfamethazine 잔류 조사 (Detection of residual sulfamethazine in serum, urine and muscle of slaughtered pigs)

  • 추금숙;오언평;최인열;송희종;채효석
    • 한국동물위생학회지
    • /
    • 제20권2호
    • /
    • pp.161-168
    • /
    • 1997
  • This study was undertaken to determined the sulfamethazine residues In urine, serum and muscle of slaughtered pigs(n: 230) by the method of TLC, EEC-4-plate and HPLC. 1. Inhibition diameter characteristics of reference bacterial substance by EEC-4-plate method and antibacterial inhibition zone was appeared sulfonamides in BS pH 7.2 2. Residual sulfamethazine was detceted from 7 serum(3.04%) and 10 urine(4.35%) by TLC test and concentration of residues was higher In urine than serum. 3. Residual sulfamethazine was detected from 9 muscle(3.91%) by EEC-4-plate method. 4. Positive samples by TLC test and EEC-4-plate method were exceed 0.1ppm quantitative analysis from 7 muscle(3.04%).

  • PDF

SOS Test Kit 및 HPLC법에 의한 도축돈의 뇨, 신장 및 근육내 설파메타진 잔류량 조사 (Determination of Sulfamethazine Residues in Urine, Kidney and Muscle of Slaughtered Pigs by SOS(sulfa on site) Test Kit and High - Performans Liquid Chromatography)

  • 황인진;박병옥;김창수;우기방
    • 한국동물위생학회지
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 1990
  • This survey was carried out to determine sulfamethazine residues in urine, kidney and muscle of slaughtered pigs. For this investigation, 20 samples for export and 30 samples for domestic market were collected at slaughterplant in Anyang city from the early of November to the end of December and comparatively were analyzed by SOS test kit and HPLC the results obtained were summarized as follows : 1. Five of 50 samples of swine urine which were inspected by SOS test kit were appeared to sulfamethazine positive 2. The sulfamethazine residue In one of 50 samples of swine muscle was exceeded 0.1ppm 3. The positive samples by SOS test kit were agreed with the results of HPLC quantitative analysis

  • PDF

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권4호
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

Development and validation of a qualitative GC-MS method for THCCOOH in urine using injection-port derivatization

  • Sim, Yeong Eun;Kim, Ji Woo;Kim, Jin Young
    • 분석과학
    • /
    • 제34권2호
    • /
    • pp.68-77
    • /
    • 2021
  • Cannabis is one of the most abused drugs in Korea. The main psychoactive component in cannabis, Δ9-tetrahydrocannabinol, is metabolized to 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) and THCCOOH-glucuronide (THCCOOH-glu) in the human liver, whereby the amount of THCCOOH-glu found in urine is twice as high as that of THCCOOH. The analytical process adapted by the majority of urine drug-testing programs involves a two-step method consisting of an initial immunoassay-based screening test followed by a confirmatory test if the screening test result is positive. In this study, a qualitative gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the detection of THCCOOH in human urine, where THCCOOH-glu was converted into THCCOOH by alkaline hydrolysis. For purification of the urine extract prior to instrumental analysis, high-speed centrifugation was used to minimize interference. In addition, an injection-port derivatization method using ethyl acetate and N,O-bis(trimethylsilyl)-trifluoroacetamide containing 1 % trimethylchlorosilane was employed to reduce the time required for derivatization, and an aliquot of the final solution was injected into the GC-MS. The method was validated by measuring the selectivity, limit of detection (LOD), and repeatability. The sensitivity, specificity, precision, accuracy, Kappa, F-measure, false positive, and false negative rate were determined by comparing the GC-MS results with those obtained using the immunoassay. The LOD was determined to be 0.32 ng/mL, while the repeatability was within 9.1 % for THCCOOH. Furthermore, a comparison study was carried out, whereby the screening immunoassay exhibited a sensitivity of 86.4 % and a specificity of 100 % compared to GC-MS. The applicability of the developed method was examined by analyzing spiked urine and forensic urine samples obtained from suspected cannabis abusers (n = 221).

尿中 抗酸菌에 관한 연구 (A Study on Acid-fast Bacteria in Urine)

  • Park, Chung-Oh;Lee, Hyeong-Choon
    • 한국환경보건학회지
    • /
    • 제13권1호
    • /
    • pp.63-65
    • /
    • 1987
  • A study on detection rates of acid-fast bacteria in urine by three sampling methods was performed on 898 cases randomly sampled from peoples who visited Dr. Chung's Health Lab. from January to December, 1983. Positive rate by 5 times sampling of motring urine was 7.0% and 12.5% higher than that of 24 hours sampling. Therefore, 5 times sampling of morning urine method was considered to be desirable method for the test of ambulatory cases.

  • PDF

원인 불명의 급성 신부전으로 발현된 급성 파라콰트중독 1례 (A case of Diagnosing Paraquat Intoxication on Transferred Patient with Acute Renal Failure)

  • 길효욱;양종오;이은영;홍세용
    • 대한임상독성학회지
    • /
    • 제2권1호
    • /
    • pp.45-48
    • /
    • 2004
  • Paraquat, a widely used herbicide, is extremely toxic, causing multiple organ failure in human. Many treatment modality has been used, but now paraquat is very fatal drug. Elimination rate of plasma paraquat seems to be a factor for the survival rate. So early diagnosis and early treatment are very important. Plasma paraquat concentration could be measured by radioimmunoassay. But it is impossible that the test was done at Emergency room and the result was checked immediately. There was relation between plasma paraquat concentrations and urine paraquat concentration. Because of its simplicity and low cost, urine paraquat concentration test is complementary to the plasma concentration measurement. If the patient has psychotic problem or unconscious mental state, and is observed unexplained dyspnea and oral ulcer, urine paraquat test is very important to rule out acute paraquat intoxication. We experienced a patient who was presented as unexplained acute renal failure initially and was diagnosed as paraquat intoxication later.

  • PDF

소변검사와 생체센서를 이용한 치매 스크리닝 애플리케이션 개발 (Development of Dementia Screening Application Using Urine Test and Bionic Sensors)

  • 김준영;조면균
    • 대한임베디드공학회논문지
    • /
    • 제10권2호
    • /
    • pp.109-117
    • /
    • 2015
  • In this paper, we have developed smart-phone App(application) for screening Dementia using bionic sensors, urine test and questionnaire. Since small amounts of urinary protein strongly predict faster cognitive decline in the elderly, smart-phone based urinalysis is adopted to screen dementia more accurately as well as bionic sensors such as $SpO_2$ and HRV(Heart Rate Variability). Firstly, DI(Dementia Index) is calculated from urinalysis, two bionic sensors and electric questionnaire, and then compared to the threshold from clinical test. Finally the results of Dementia screening is shown in your smart-phone and useful information to prevent or relieve Dementia is also given. We performed simple testing on persons aged over 60 and found out the proposed application can be useful devices for screening Dementia easily and quickly.

Measurement of urinary protein in children

  • Myung Hyun Cho
    • Childhood Kidney Diseases
    • /
    • 제26권2호
    • /
    • pp.69-73
    • /
    • 2022
  • Proteinuria is an early hallmark of kidney disease and a major risk factor for systemic cardiovascular diseases. There are several methods to measure proteinuria, such as the urine dipstick test, 24-hour urinary protein excretion method, and spot urine for the protein-to-creatinine ratio. The urine dipstick test is simple but inaccurate. The 24-hour urinary protein excretion method is the gold standard; however, it is cumbersome, especially in children. Spot urine for the protein-to-creatinine ratio is simple and accurate, but has limitations. Specific urinary protein such as albumin can be measured instead of the total protein content. Tests should be avoided in situations that cause transient proteinuria or false-positive results. It should be performed correctly, and its limitations should be recognized and interpreted accurately.