• Title/Summary/Keyword: Urine analysis

Search Result 768, Processing Time 0.029 seconds

Analysis of Synephrine and Octopamine in Citrus Fruits, Drinks, and Human Urine (Citrus Fruits, 드링크류, 소변중 Synephrine과 Octopamine의 분석에 관한 연구)

  • 노동석;이정애;김승기;정현숙;유보경;박종세
    • Journal of Food Hygiene and Safety
    • /
    • v.10 no.3
    • /
    • pp.189-197
    • /
    • 1995
  • Analytical method for synephrine and octopamine in citrus fruits, drinks containing citrus fruit, and human urine was developed using gas chromatography / mass spectrometry(GC/MS), Silylation with MSTFA, acetylation with MBTFA, and trimethylsilylation with MSTFA followed by trifiuoroacetylation with MBTFA were compared. The selective derivatization of synephrine and octopamine was optimized with two derivatizing reagents ; MSTFA and MBTFA. The ion at m/z 267 was monitored to characterize the benzyl group of the both compounds. Synephrine was detected in the concentrations of 0.46∼1.88 ug/g for citrus fruits and 1.2∼8.1 ug/ml for drinks. The urinary excretion data of synephrine showed the highest concentration at the period of 8-20 hours after drinking orange juices and total amounts of its urinary excretion calculated as a parent compound was 11-14% of a dose during 48 hours. Octopamine was not detected in citrus fruits, drinks, and human urine.

  • PDF

Changes of Potassium in Open Heart Surgery (개심술시의 포타시움 변화)

  • 이홍섭
    • Journal of Chest Surgery
    • /
    • v.11 no.4
    • /
    • pp.422-427
    • /
    • 1978
  • Alterations in the serum and urine potassium were studied in twenty patients who underwent open heart surgery in National Medical Center during the period from Jan.1978 to June 1978. There were twelve cases congenital heart disease and eight acquired heart disease. Rigg-Kyvsgaad mark IV roller pump and Polystan bubble oxygenator were used in all patients. Hemodilution was carried out by priming the oxygenator with Hartmann`s solution. Measurements were made of the serum electrolyte, gas analysis and twenty four hour urine electrolytes. During the bypass, the serum potassium decreased Significantly from 4.2?.47 to 3.6?. 72 mEq. per liter. [p<0.05] Fifty seven miliequivalant of potassium chloride were added during operation-urine potassium was higher in the diuretic group than in the non diuretic group. Plasma potassium level in the diuretic group was more significantly reduced than nondiuretic group. In this series large amount of urine potassium loss was noted on the day of operation, the first and second post operative day.

  • PDF

The Analysis of Common Metabolites of Organophosphorus Pesticides in Urine by Gas Chromatography/Mass Spectrometry

  • 박성수;표희수;이강진;박송자;박택규
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • Most organophosphorus pesticides may be metabolized to yield some common phosphates in human or in animals, and these metabolites may be used as the exposure biomarkers to pesticides. In this study, we developed the extraction method of four phosphate metabolites from the spiked human urine in high recovery by the solid phase extraction with a reverse-phase cartridge (cyclohexyl silica) followed by the elution with methanol. The extracted urinary metabolites were derivatized with hexamethyldisilazane/trimethyl-chlorosilane/pyridine (2 : 1 : 10, v/v/v) and identified by gas chromatography/mass spectrometry. Calibration curve obtained from each metabolite standard using by GC/MS/SIM has shown good linearity and detection limits of metabolites were the range of 0.05-0.1 ㎍/㎖ in urine. Phenthoate, one of the organophosphorus pesticides, was orally administrated to rats. Four metabolites were detected in the rat urine. The results of this study may be applied to development of exposure biomarkers for monitoring of environmental pollutants.

Development and Evaluation of Validity of Short Dish Frequency Questionnaire (DFQ) for Estimation of Habitual Sodium Intake for Korean Adults (우리나라 성인의 나트륨 섭취량 추정을 위한 음식섭취빈도조사지의 개발과 타당성 검증에 관한 연구)

  • Son, Sook-Mee;Park, Young-Sook;Lim, Wha-Je;Kim, Sook-Bae;Jeong, Yeon-Seon
    • Korean Journal of Community Nutrition
    • /
    • v.12 no.6
    • /
    • pp.838-853
    • /
    • 2007
  • The aim of this study was to develop various types of a dish frequency questionnaire (DFQ) for estimating the habitual sodium intake and to evaluate the validity of a 125 item dish frequency questionnaire (DFQ 125) with the DFQ 70, DFQ 36 and DFQ 15. For the DFQ 125, one hundred and twenty five dish items were selected based on the information of sodium content of a one serving size, consumption frequency and dish items that contributed most to the variation of sodium intake. Frequency of consumption was determined through nine categories ranging from more than 3 times a day to almost never to indicate how often the specified amount of each food item was consumed during the past 6 months. The sodium intake estimated with DFQ 125 was $5775.0{\pm}3636.3mg$, 12.6% higher than that estimated with a 24 hr urine analysis ($5009.7{\pm}1541.9mg$) and significant correlation was observed between them (r=0.3315, p<0.001). When sodium content in broth leftover was subtracted from the total intake, the actual sodium intakes was decreased to $5309.6{\pm}3076.6mg$, which was 3.2% higher than that with a 24-hr urine analysis. Overall, 56% of subjects in the lowest quintile of sodium intake computed with DFQ 125 were also in the lowest of adjacent quintile while categorization into the opposite quintile were 4.9%. DFQ 70 was developed from DFQ 125 by omitting the food items not frequently consumed, selecting the dish items that showed higher sodium content per one portion size and higher consumption frequency. The sodium intake estimated with DFQ 70 ($5026.6{\pm}3107.1mg$) showed only 0.2% difference from that estimated with a 24-hr urine analysis, significant correlation with it (r=0.3199, p<0.001) and higher proportion of subjects to be classified into the same or adjacent quintile. The sodium intake estimated with DFQ 36 or DFQ 15 was also significancy correlated with that estimated with a 24-hr urine analysis (r=0.3441, p<0.001; r=0.321, p<0.001 respectively) and more. The proportion of subjects was classified into the same or adjacent quintile. However, the actual sodium intake estimated with DFQ 36 or DFQ 15 were $3534.0{\pm}1804.6mg\;and\;2508.0{\pm}1261.5mg$, respectively, 31.3% or 51.3% less than that estimated with a 24-hr urine analysis. It seems the DFQ 125 with subtraction of sodium content in broth leftover or DFQ 70 can be used quantitatively to estimate sodium intake of adults. DFQ 36 or DFQ 15 can be used as a screening tool or to assess the changes of sodium intake after nutrition education.

Metabolic Profiling of Urine Samples from Colorectal Cancer Patients Before and After Surgical Treatments

  • Chae, Young-Kee;Kang, Woo-Young;Kim, Seong-Hwan;Joo, Jong-Eun;Han, Joon-Kil;Hong, Boo-Whan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.14 no.1
    • /
    • pp.28-37
    • /
    • 2010
  • Metabolites of urine samples from 6 colorectal cancer patients were analyzed by two-dimensional NMR spectroscopy, where the samples were collected before and after the surgical treatments per patient. NMR data were analyzed with the help of the metabolome database and the statistics software. Urine samples before and after the treatments showed significantly different metabolic profiles from each other. We were able to compare 10 different metabolites. Most of the assigned metabolites of every patient showed a tendency of increase after the surgery except for a few cases. The amount of changes in individual metabolites varied significantly from patient to patient, but the combination of such changes could be used to distinguish the condition before the surgery from after, which could be done by PCA analysis. The analysis via $^{1}H-^{13}C$ HSQC spectra proved to be applicable in assessing and classifying global metabolic profiles of the urines from colorectal cancer patients.

Analysis of Heterocyclic Amines in Human Urine Using Multiple Solid-Phase Extraction by Liquid Chromatography/Mass Spectrometry

  • Cha, Hyun-Jeong;Kim, Nam-Hee;Jeong, Eun-Kyung;Na, Yun-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2322-2328
    • /
    • 2010
  • A multiple solid-phase extraction (SPE) method was used with liquid chromatography, coupled with mass spectrometry (LC/MS), for the analysis of heterocyclic amines (HCAs) in human urine. Separation efficiencies based on the pH of the mobile phase and the types of columns were compared. An amide column showed better baseline separation and narrower HCA peak widths at pH 5.0 for the mobile phase than a $C_8$ column. Each SPE step, HLB, MCX, and HybridSPE, was optimized by controlling the pH conditions. The combined method with the three SPEs effectively removed interfering species that cause ion-suppression during HCA detection. Validation of the method, performed with SIM and SRM detection, showed correlation coefficients above 0.991 in the range 0.3 - 16.7 ng/mL. Recovery rates were 45.4 - 97.3% on the $C_8$ column and 71.8 - 101.4% on the amide column, and method detection limits were 0.11 - 0.65 ng/mL on the $C_8$ column and 0.12 - 0.48 ng/mL on the amide column. This method using multiple SPEs offers significant benefits for high-throughput determination of HCAs in urine.

Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry

  • Jang, Haejong;Mai, Xuan-Lan;Lee, Gunhee;Ahn, Jae Hyoung;Rhee, Jongsook;Truong, Quoc-Ky;Vinh, Dinh;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.9 no.4
    • /
    • pp.95-99
    • /
    • 2018
  • An innovative, simple, and rapid assay method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the simultaneous determination of eight statin drugs in human urine. A simple sample clean-up procedure using the "dilute and shoot" (DAS) approach enabled a fast and reliable analysis. The influence of the dilution factor was investigated to ensure detectability and reduce the matrix effect. Chromatographic separation was performed on a Phenomenex Kinetex C18 column ($50{\times}3.0mm$ i.d., $2.6{\mu}m$) using an elution gradient of mobile phase A composed of 0.1% acetic acid, and mobile phase B composed of acetonitrile, at a flow rate of 0.35 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using electrospray ionization in positive ion mode. The total chromatographic run time was 15 min. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy, precision, and stability. The present method was successfully applied to the analysis of Rosuvastatin in urine samples after oral administration to healthy human subjects.

Urine Collection from Disposable Diapers in Infants and Young Children (유소아에서 일회용 기저귀를 이용한 소변 채취 방법)

  • Kim Mi Jeong;Kim Ji Hae;Yim Hyung Eun;Kang Hee;Eun Baik Lin;Yoo Kee Hwan;Hong Young Sook;Lee Joo Won;Kwon Junga
    • Childhood Kidney Diseases
    • /
    • v.9 no.2
    • /
    • pp.128-136
    • /
    • 2005
  • Purpose : Urine collection using a sterile adhesive bag for urinalysis has been used commonly in infants and young children. However, this method has had some drawbacks. So, this study was performed to evaluate the usage of disposable diapers as a substitute for the routine urine collection method. Methods : 60 mL of self voided fresh urine was collected from 99 patients. Half of the urine was poured on the disposable diapers which did not contain absorbent gel beads. After 1 hr, we obtained the urine samples(extracted urine) by compressing the wet diapers using a 50 ml syringe. Routine, microscopic and biochemical analyses were performed on the other half of fresh urine and extracted urine. Then we compared each result by correlative analysis. Results : 198 samples from 99 patients were evaluated. The results of routine urinalysis except WBC and biochemical urinalysis showed a significant correlation between the two groups(P<0.05). The relative coefficients of urine SG, pH, glucose, protein, blood and leukocytes between the two groups were 0.964, 0.938, 0.977, 0.956, 0.931 and 0.738, respectively. Those of urinary sodium, potassium, chloride and creatinine were 0.997, 0.998, 0.995 and 0.998, respectively Microscopic examinations showed lower relative coefficients than the other results, 0.740 for RBC and 0.602 for WBC, but these were still significant(P<0.05). Conclusion : The results of the urine analysis with extracted urine from diapers correlates well with that of fresh urine. This new method is very helpful and can be used as an alternative of urine collection, especially for infants and young children. (J Korean Soc Pediatr Nephrol 2005;9:128-136)

  • PDF

Simultaneous determination of nalbuphine and methamphetamine in drug abuser's urine

  • Park, Mee-Jung;Choi, Wha-Kyung;Choi, Sang-Kil;Son, Haeng-Ja;Lim, Mi-Ae;Chung, Hee-Sun
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.275.1-275.1
    • /
    • 2003
  • Because people who take more than two drugs have increases, a simple and sensitive method for the simultaneous analysis of amphetamine, methamphetamine and nalbuphine in urine was developed. After alkalinization of the urine samples with 6 N-NaOH, the analytes were extracted using ethyl acetate, derivatized with MSTFA : TSIM : TMCS (= 100 : 2 : 5) prior to gas chromatography-mass spectrometry(GC-MS) analysis with selected ion monitoring. (omitted)

  • PDF

A Study on the Development of Urine Analyzer System (뇨분석 시스템 개발에 관한 연구)

  • Lee, S.J.;Choi, B.C.;Kim, K.N.;Hong, S.I.;Kim, J.H.;Kim, J.H.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.303-308
    • /
    • 1997
  • In this paper, we analyzed the spectroscopic properties of strip to analyzer urine qualitatively & quantitatively and make urine analyzer system stable by spectroscopy, and research the property of preamplifier unit. The analysis of spectroscopic properties of 10 pads in the strip is used for determine the wave length of light source of optic detector unit and used for basic materials which are necessary that we develop the algorithm analyzing the density grade of pad accurately. We make preamplifier unit by using the current to frequency method to measure the distribution of pad color. We implemented urine analyzer system. This system's hardware is composed of measuring unit for detect of distribution density of strip pad, main processing unit, communication unit, interface device, thermal printer, and indicator. The software consists of the program which manage the argument of test, proportion initial value of urine analyzer and calibrate analyzed result.

  • PDF