• 제목/요약/키워드: Urban tunnel

검색결과 420건 처리시간 0.022초

Multi-sensor data fusion based assessment on shield tunnel safety

  • Huang, Hongwei;Xie, Xin;Zhang, Dongming;Liu, Zhongqiang;Lacasse, Suzanne
    • Smart Structures and Systems
    • /
    • 제24권6호
    • /
    • pp.693-707
    • /
    • 2019
  • This paper proposes an integrated safety assessment method that can take multiple sources data into consideration based on a data fusion approach. Data cleaning using the Kalman filter method (KF) was conducted first for monitoring data from each sensor. The inclination data from the four tilt sensors of the same monitoring section have been associated to synchronize in time. Secondly, the finite element method (FEM) model was established to physically correlate the external forces with various structural responses of the shield tunnel, including the measured inclination. Response surface method (RSM) was adopted to express the relationship between external forces and the structural responses. Then, the external forces were updated based on the in situ monitoring data from tilt sensors using the extended Kalman filter method (EKF). Finally, mechanics parameters of the tunnel lining were estimated based on the updated data to make an integrated safety assessment. An application example of the proposed method was presented for an urban tunnel during a nearby deep excavation with multiple source monitoring plans. The change of tunnel convergence, bolt stress and segment internal forces can also be calculated based on the real time deformation monitoring of the shield tunnel. The proposed method was verified by predicting the data using the other three sensors in the same section. The correlation among different monitoring data has been discussed before the conclusion was drawn.

Analysis of pile group behaviour to adjacent tunnelling considering ground reinforcement conditions with assessment of stability of superstructures

  • Young-Jin Jeon;Cheol-Ju Lee
    • Geomechanics and Engineering
    • /
    • 제33권5호
    • /
    • pp.463-475
    • /
    • 2023
  • Tunnel construction activity, conducted mainly in mountains and within urban centres, causes soil settlement, thus requiring the relevant management of slopes and structures as well as evaluations of risk and stability. Accordingly, in this study we performed a three-dimensional finite element analysis to examine the behaviour of piles and pile cap stability when a tunnel passes near the bottom of the foundation of a pile group connected by a pile cap. We examined the results via numerical analysis considering different conditions for reinforcement of the ground between the tunnel and the pile foundation. The numerical analysis assessed the angular distortion of the pile cap, pile settlement, axial force, shear stress, relative displacement, and volume loss due to tunnel excavation, and pile cap stability was evaluated based on Son and Cording's evaluation criterion for damage to adjacent structures. The pile located closest to the tunnel under the condition of no ground reinforcement exhibited pile head settlement approximately 70% greater than that of the pile located farthest from the tunnel under the condition of greatest ground reinforcement. Additionally, pile head settlement was greatest when the largest volume loss occurred, being approximately 18% greater than pile head settlement under the condition having the smallest volume loss. This paper closely examines the main factors influencing the behaviour of a pile group connected by a pile cap for three ground reinforcement conditions and presents an evaluation of pile cap stability.

대심도 복층터널 화재 시 유입풍속 저감방안 연구 (A Study on the Inflow Velocity Reduction Measures in Case of Fire Great Depth Underground Double-Deck Tunnel)

  • 양용원;문정주;신태균
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.81-86
    • /
    • 2016
  • 최근 국내 도심지 도로는 빈번한 교통정체가 발생하고 있다. 도심지 교통정체를 해소하기 위한 방안으로 국내에서는 대심도 복층터널에 대한 계획이 이루어지고 있다. 국내에서 계획되는 대심도 복층터널은 소형차 전용으로 계획되며 네트워크형의 구조를 가지고 있어 차량의 출입이 지하공간에서 이루어지고 있다. 이러한 네트워크형 대심도 복층터널은 터널의 단면 및 높이가 일반도로터널 보다 작고 차량의 출입으로 인한 교통풍의 작용으로 화재연기가 터널 승객의 대피보다 빠르게 전파되어 인명피해 발생이 예상된다. 따라서 본 연구에서는 국내 네트워크형 대심도 복층터널에 화재시 화재연기 확산지연을 방지하고자 화재연기 확산지연 장치 작동시 터널 차단면적에 터널 내 작용하는 유입풍의 저감효과를 분석하였으며, 분석결과 터널 차단면적이 50% 이상일 경우 터널 내 작용하는 풍속을 약 21% 저감시키는 효과가 나타났으며, 면적이 50% 이상일 경우 화재 연기의 확산속도를 약 21% 저감시켜 안전한 대피에 도움이 될 것이라 판단된다.

도시철도 터널 내부 콘크리트 도상 국소공명흡음판의 흡음계수 및 구조안정성 평가를 위한 계측시스템 개발 (Developments of monitoring system to measure sound absorbing coefficient and structural stability of sound absorbing panel on the concrete track in the urban train tunnel)

  • 오순택;이동준;이동훈
    • 한국터널지하공간학회 논문집
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 2017
  • 본 연구에서는 터널 내 콘크리트 도상을 모사하여 현장실험을 수행하였다 그리고 도시철도터널 내 콘크리트도상의 반사소음을 저감하기 위한 다중국소공명 흡음판의 이론적 평가항목과 한계를 고려하여 허용한계를 연구하였다. 본 연구결과는 도시철도 터널 구간에서의 차량 주행속도에 따른 유동 영향에 의한 흡음판의 흡음계수를 분석하고, 구조안정성을 효율적으로 평가할 수 있는 최대 변위와 변위가 속도 및 동적특성인 감쇠비와 고유진동수를 효과적으로 도출할 수 있는 계측시스템을 제안한다.

도시 협곡에서 수목이 흐름과 스칼라 물질 확산에 미치는 영향 (Effects of Trees on Flow and Scalar Dispersion in an Urban Street Canyon)

  • 강건;김재진
    • 대기
    • /
    • 제25권4호
    • /
    • pp.685-692
    • /
    • 2015
  • In this study, the effects of trees on flow and scalar dispersion in an urban street canyon were investigated using a computational fluid dynamics (CFD) model. For this, we implemented the drag terms of trees to the CFD model, and compared the CFD-simulated results to the wind-tunnel results. For comparison, we considered the same building configuration as the wind-tunnel experiment. The trees were located at the center of street canyon with the aspect ratio (defined as the ratio of the street width to the building height) of 1. First, the flow characteristics were analyzed in the tree-free and high-density tree cases and the results showed that the CFD model reproduced well the flow pattern of the wind-tunnel experiment and reflected the drag effect of trees in the street canyon. Then, the dispersion characteristics of scalar pollutants were investigated for the tree-free, low-density tree and medium-density tree cases. In the tree-free case, the nondimensionalized concentration distribution simulated by the CFD model was quite similar to that in the wind-tunnel experiment in magnitude and pattern. The correlation coefficients between the measured and simulated concentrations are more than 0.9 in all the cases. As the tree density increased, nondimensionalized concentration increased (decreased) near the wall of the upwind (downwind) building, which resulted from the decrease in wind speed case by the drag effect of trees. However, the CFD model underestimated (overestimated) the concentration near the wall of upwind (downwind) building.

도심지 NATM 터널 굴착시 적용된 미진동발파 공법 개선사례 (A Case of the Alternative Method to Improve the Ambient Vibration Blasting Method Applied NATM Tunnel Construction in Urban Areas)

  • 이종윤;황연수;최학용;배효진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.535-542
    • /
    • 2010
  • Various difficulties have been increased in the construction of public structure; like the road in the overcrowding urban area, because of civil complaint, cost and period of construction. In oder to overcome these social problems, the tunnel has been planned the road design. Despite the resolution, there are many technical problems when constructed near facilities. The design of new tunnel below the existing service reservoir is applied to the ambient vibration blasting using Plasma. The result of test blasting was exceeded the standard ("2kine"). So it was considered a countermeasure for the vibration reduction applied to change the controlled blasting method, reduce the charge, add the pre middle horizontal hole in the cut blasting site, and so on. The result was satisfied the standard. Accordingly, if the quality of blasting process can be managed well, the application of this alternative method is highly effective one. Also, based on cost analysis between two methods, the alternative method is very competitive.

  • PDF

건물 사이에 풍력발전기를 설치하기 위한 기류특성분석 (Analysis of Air Current Characteristics for Installing Wind Turbines Between Buildings)

  • 박민우;유장열;손영무;유기표
    • 한국공간구조학회논문집
    • /
    • 제18권1호
    • /
    • pp.117-125
    • /
    • 2018
  • Recently, various building integrated wind power (BIWP) approaches have been used to produce energy by installing wind power generators in high-rise buildings constructed in urban areas. BIWP has advantages in that it does not require support to position the turbine up to the installation height, and the energy produced by the wind turbine can be applied directly to the building. The accurate evaluation of wind speed is important in urban wind power generation. In this study, a wind tunnel test and computational fluid dynamics (CFD) analysis were conducted to evaluate the wind speed for installing wind turbines between buildings. The analysis results showed that the longer the length of the buildings, which had the same height, the larger the wind speed between the two buildings. Furthermore, the narrower the building's width, the higher the wind velocity; these outcomes are due to the increase in the Venturi effect. In addition, the correlation coefficient between the results of the wind tunnel test and the CFD analysis was higher than 0.8, which is a very high value.

소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구 (A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles)

  • 홍서희;백두산
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.745-756
    • /
    • 2022
  • 도로터널은 입구와 출구를 제외한 모든 면이 막혀있는 반밀폐공간으로 화재가 발생할 경우 화재 연기는 화재로 인한 열부력과 터널 내 상시 존재하는 기류에 의해 종방향으로 확산하게 된다. 이러한 문제를 해결하기 위해 도로터널에는 연기의 이동방향을 제어하거나 화재지점에서 직접 배연함으로써 안전한 대피환경을 확보하고 신속한 구조 및 소화 활동을 위해 제연 설비를 설치하고 있다. 도심지에서는 인구 증가에 따른 교통량 증가로 인해 도심지 도로의 서비스 수준이 저하되어 극심한 정체현상이 빗어지고 있으며, 이에 대한 해결방안으로 도심지에 지하도로의 건설이 증가하고 있는 추세이다. 수소연료전지차(FCEV)의 TPRD를 통한 수소 누출 시 화재가 발생하는 경우, 화재강도는 누출량에 의존하며, 최대 화재강도는 TPRD의 오리피스 직경에 따라 달라진다. 본 연구에서는 TPRD의 오리피스 직경 1.8 mm를 고려하여 최대 화재강도가 15 MW일 때, 소형차전용터널 내 차도 풍속과 대배기구의 개방 간격에 따른 화재연기의 확산거리에 대해 분석하였다. 그 결과, 터널 내 차도 풍속이 1.25 m/s 이하인 경우 터널 내 기류제어가 가능하였으며, 댐퍼 간격이 50 m, 100 m 인 경우 화재로부터 200 m 범위 이내에서 제연이 가능한 것으로 분석됐다.

도심지 대심도 터널 건설을 위한 제도개선 방안 연구 (A study of measures to improve the system for the construction of deep tunnels in urban area)

  • 문훈기;문준식;신종호
    • 한국터널지하공간학회 논문집
    • /
    • 제25권6호
    • /
    • pp.469-478
    • /
    • 2023
  • 도심지 대심도 터널은 자동차와 열차가 다니던 지상공간을 친환경적인 공원으로 시민에게 돌려주고, 지하는 복합적인 교통인프라 시설의 구축이 가능한 미래지향적인 건설방안이다. 하지만 일부 언론과 영화에서 터널공사는 지반침하, 붕괴 등의 재난의 대상으로 묘사하는 경우가 종종 있었다. 실제로 대부분의 도심지 대심도 터널공사 진행 과정에서 노선 부근 주민의 굴착 반대 민원으로 인해 사업추진에 어려움을 겪고 있다. 본 연구에서는 대심도 터널과 관련된 시민여론조사를 통해서 지하 공간개발에 대한 인식과 대심도 터널 공사에 대한 시민 우려사항을 파악하고 이해관계자의 손실보상에 대한 의견을 조사하였다. 대심도 터널공사와 관련된 현행법령을 검토하여 공사단계별 공공참여 가능성을 분석하고 지하공간의 보상과 관련된 구분지상권에 대하여 살펴보았다. 여론조사에서 시민이 우려하는 대심도 터널공사의 이슈사항이 현행기술로 해결 가능한 문제임을 파악하고 공공참여를 통해 터널공사의 안정성을 확신시키기 위한 제도적 개선 방향과 구분지상권 설정에 이해관계자의 협조를 증진하려는 개선방안을 제시하였다.

Internet 기반의 터널 시공 위험도 관리 시스템 개발 (Development of An Internet-Based Tunnel Construction Risk Management System)

  • 유충식;김재훈;박영진;유정훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.679-686
    • /
    • 2002
  • A substantial portion of the cost of a tunnelling project in urban environments is, therefore, devoted to prevent ground movement. Therefore, prediction of ground movements and assessment of risk of damage to adjacent buildings has become an essential part of the planning, design, and construction of a tunnelling project in the urban environments. An internet-based tunnelling-induced ground movements and building damage assessment system (IT-TURIMS) was developed and implemented to Daegu Metro Subway Line tunnel construction project in Korea. This paper describes the concept and implementation of IT-TURIMS. Practical significance of tunnelling risk assessment is also discussed.

  • PDF