• Title/Summary/Keyword: Urban remodeling

Search Result 98, Processing Time 0.022 seconds

Field Case Study on Regeneration of Decaying Ex-factory area in a Creative City 「Bologna」 (창조도시 볼로냐의 쇠퇴공장지역 재생 현지사례연구)

  • Lee, Yeunsook;Yoon, Hyegyung;Soo, Kabsoo
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.51-59
    • /
    • 2008
  • response to the global city. It was developed to cope with the decline of the manufacturing industry, a rise in unemployment and a welfare state system in danger. In cities of the concept, there has been much change in existing urban space and accordingly wisdoms and knowledge has been accumulated. The purpose of this research is to scrutinize urban spatial modification of a regenerated model city "Bologna". The target area of analysis was a ex-factory ailing district. Field site visit, deep interview with professionals and citizens, walk through observation, and historial literature review on the site were employed. As results, its history, retrofit process and current change were systematically described. The results showed ways of thinking, attitude toward historic preservation, technology, and creativity of using existing buildings for contemporary functions. This has a significant implication on Korean urban development which mostly, has ignored the existing value of community and buildings.

Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement) (교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구))

  • Cho, Min-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

Analysis on Priority of Influence Factors for Management of Vertical-extension Remodeling Project (수직증축 리모델링공사의 효율적 관리를 위한 영향요인 분석)

  • Lee, Dong-Heon;Lim, Hyoung-chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.314-321
    • /
    • 2016
  • After the 1980s, as the economy was growing rapidly and the real estate market was active, a large increase in population was supplied to the city. Accordingly, the national apartment housing market is located in the form of Urban Housing Culture. On the other hand, with time, the supply apartment houses became superannuated and the residential environment became poor. Therefore, the environment of old apartment houses has been changed to improve by reconstruction. Despite this, reconstruction incurred not only a lot of construction waste, but also problems of environmental degradation, noise, traffic congestion, increasing number of households, and so on. Recently, the housing law has changed, and vertical extension remodeling focused on Small/Medium Town House is underway. This has been changed in response to the demand. This is one of essential parts in the remodeling field for the future, even though it has some problems in how uses existing buildings. Therefore, this study analyzed occurrence risk factor for each type through research materials and case analysis regarding the vertical extension remodeling of apartment housing. In addition, the relative importance was determined through questionnaires and interviews from constructors, designers, and experts in the field.

The Set of Performance Evaluation Index of Remodeling in Rural Housing for Residential Environments Improvement (주거환경개선을 위한 농촌주택 리모델링 성능평가지표 설정에 관한 연구)

  • Kim, Hye-Lan;Lim, Chang-Su;Kim, Eun-Ja;Hong, Kwang-Woo;Moon, Ho-Gyeong
    • Journal of Korean Society of Rural Planning
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • Living environments in rural area have become deteriorated rapidly. Increase of aging population, decline in agricultural income, polarization of wealth in rural community due to rural returners have caused severe decline and imbalance of living environments in rural area. Responding to this circumstances, governments currently develop projects for improving living environments focusing on individual housing which were excluded from governmental supports because those had been regarded as private property. Nevertheless, there are still some gaps and problems in evaluating the quality of living environment and suggesting effective solutions. It would be because standards and guidelines of the projects have been based on urban housing system. In order to support the implementation of the projects, this research has developed an index for evaluating and monitoring the quality of living environments in rural area. By applying Delphi method, the index has been created in four categories of 'security', 'convenience', 'comfortability', and 'durability' 'Security' consists of structural safety, crime, disaster, accident prevention. 'Convenience' includes three divisions of living, traffic, farm working. 'Comfortability' is divided into sanitation, indoor environments, and aesthetic appreciation. Lastly, 'durability' has four divisions of energy conservation, environmental friendliness, efficiency, and economics. Each sub-division also has different items from three to twelves. In the case of an index for performance evaluation, items have been derived from energy conservation(6-items), and environmental friendliness(7-items). Items developed as an index for evaluating rural living environments in this research might be good background information for remodeling project in rural housing development.

A Study on Changes of Land Use in the Local Port City - Focused on Yeosu in Jeonnam Province - (지방 항구도시의 토지이용 변화에 관한 연구 - 전라남도 여수시를 중심으로 -)

  • Chung, Kumho
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.25 no.1
    • /
    • pp.9-16
    • /
    • 2023
  • This study is on the formation and the development process of urban space by referring to the literature in Yeosu where is the important location in logistics & transportation and maritime since the Japanese colonial period. There are many factors and results of the development process in Yeosu by the opening port, railroads, loads and industries. The purpose of this study is to understand the characteristics of the formation process of urban space and the characteristics of physical space in Yeosu. The results are as follow; The urban formation and development process in Yeosu where was a small fishing village in the 1910s is largely divided into four processes. Formation: the population increased due to constructions such as of a railroad, a port, and roads and there were many reclamations around the center of the old city center in the Japanese colonial period. Stagnation: There was no urban development due to stagnation, war, and the Yeo-sun Incident. Expand: the industrialization of the Yeocheon Industrial Complex and Gwangyang Steel and other areas around Yeosu led to a surge in Yeosu's population. To cope with this, the city was expanded through three land readjustment projects and the development of large-scale residential complexes. Decline and Remodeling: Yeosu's urban space declined due to the decline of fisheries and the decrease in marine and railway logistics. And the expansion and improvement of the transportation network for hosting the Yeosu World Expo increased the accessibility of the old city center, transforming it into a tourist city using cultural heritage and nature.

Development of Estimation System for Housing Remodeling Cost through Influence Analysis by Design Elements (설계요소별 영향분석을 통한 공동주택 리모델링 공사비개산견적 산출 시스템 개발)

  • Kim, Jun;Cha, Heesung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.6
    • /
    • pp.65-78
    • /
    • 2018
  • In As urban apartment are aging, the necessity of reconstruction or remodeling to extend the life of buildings is increasing. In such a case, a co-housing association is formed to implement decisions on reconstruction or remodeling projects. At this time, the most important thing for the co-housing association is the business feasibility based on the input of the construction cost.In the case of reconstruction, it is possible to estimate the construction cost by using the accumulated construction cost data, and then evaluate the feasibility using the construction cost. However, in case of remodeling, it is difficult to calculate the accurate construction cost because the number of accumulated construction cost data is small. In addition, non-specialist clients often require estimates of various design factors, often negatively impacting the accuracy of estimates and the duration of estimates. Therefore, in this study, proposed method to reflect the opinion of the owner who is a non-expert, as a design element, and a method of calculating the expected construction cost according to the design element, and constructed this system so that it can be easily used by the non-specialist owner. In order to clearly reflect the requirements of the non-specialist owner in the estimates, extracts the design elements from the existing remodeling cases, classify them, and suggest a plan for the client to choose. In order to reflect the design factors to the estimates, the existing apartment house remodeling cases were investigated and the design factors were extracted to have a large effect on the construction cost. Finally, developed system based on MS Excel so that the above contents can be easily used by a non-specialist client. In order to verify the accuracy of the proposed estimate in this study, verified the accuracy of 80% of the results by substituting the case of remodeling quotations and obtained a positive result from the questionnaire survey to examine the ease of use of the non-specialist customer. In this study, propose an estimate estimation method using four cases. If the remodeling cases are accumulated continuously, the expected effect of this study will be higher.

The Effect of the Attached Glazing and Windbreak on the Thermal Performance and Air Tightness of Sliding window (덧유리 및 방풍재 적용을 통한 슬라이딩 창의 단열 및 기밀성능 개선효과 분석)

  • Bae, Min-Jung;Kang, Jae-Sik;Choi, Gyeong-Seok;Choi, Hyung-Joung
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.59-65
    • /
    • 2017
  • Purpose: Thermal performance and air tightness of window are improved for the building energy efficiency. As the deteriorated houses are increased, the improve measures with low cost and easy installation are developed in the energy performance of window. Attached glazing and windbreak can be easily applied to the window with low cost. In this paper, the effect of the attached glazing and windbreak on the thermal performance and air tightness of window is analyzed as the measure to improve performance of window. Method: Thermal transmittance of glazing is evaluated through WINDOW simulation according to thickness of attached glazing and air cavity. Based on the simulation results, thermal transmittance, air tightness and condensation resistance performance of four cases are tested according to Korea standards. One type of PVC sliding double window is chosen as the specimen. For the analysis on low performance of window, the outside of window is excluded in the PVC sliding double window. Result: This study shows that thermal performance of glazing can be increased by the application of attached glazing. Furthermore, lower thermal performance of glazing can obtain the higher effect of attached glazing. The application of attached glazing and windbreak can effect on increasing thermal performance and air tightness of window.

Structural Behavior of Slab in the Partial Demolition for the Apartment Remodeling (아파트 리모델링을 위한 부분해체에서 슬래브의 구조적 거동)

  • Choi, Hoon;Joo, Hyung Joong;Kim, Hyo Jin;Yoon, Soon Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.19-30
    • /
    • 2012
  • Due to the fact that the social environment is improved and the urban development is stabilized, the demand of new construction of apartment becomes slowdown. Accordingly, there are many researches to lengthen the service life of the existing apartment through the remodeling and its importance is continuously rising. However, reliable design specifications and guidelines for the design of remodeling with partial demolition are not provided yet in Korea. Specially, in the apartment remodeling, slab collapse accidents take major portion in all accidents that reported by Korean Government. It is very important to prevent intial crack of slab because intial crack could cause severe accident like collapse of all structure in a short period of time. The purpose of this study is to develop structural guidelines that could guarantee the structural safety and serviceability of slab structure and could be adopted in Korean remodeling with partial demolition. There are mainly two components to determine structural behavior of slab structure. One is the shape of slab structure and the other is load which is resisted by the slab structure. In this study, the weight per unit volume of concrete debris and concrete strength are estimated through the analysis of previous researches to recognize the relationship between the shape of slab and load that loaded on the slab. Accordingly, approximately 300 pieces of floor plan are collected and analyzed. The finite element analysis is conducted using these analyzed and estimated results. From the finite element analysis results, the limited stacking height of debris is suggested and the stacking method is also discussed. In addition, to find the relationship between movement of demolition equipment and structural behavior of slab, the static and dynamic loading tests are conducted. From the results of loading tests, the impact factor which will be considered in the remodeling design could be estimated.

A Study on the Development of Rolled Dry Floor Heating System for Improving Workability (현장 시공성 개선을 위한 롤타입 건식바닥난방시스템 개발)

  • Lee, Gyu-Dong;Kim, Jun-Ho;Jeong, Chang-Ho;Kim, Dong-Woo;Ogawa, Keiichiro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.177-180
    • /
    • 2012
  • Korea residential housing generally use wet floor heating system 'Ondol' which consist of insulation cushioning, lightweight foamed concrete, hot water pipe and mortar on top of reinforced concrete slab. Wet floor heating system's installation process is too complicate and difficult to supervise field for continuing assurance quality. Also, this method has a huge impact on the progress of construction because it take a long time to cure finishing mortar and lightweight foamed concrete. Therefore, it is considered a disturbance factor of reduction of construction duration for enhancing competitiveness. In this study, we conducted an experiment about the radiant heat performance and temperature difference on upper panel of rolled dry floor heating systems which is jointly developed by Kolon global and Sumisho Metalex for remodeling housing, studio apartment and the urban-life housing.

  • PDF

Analysis of Living Space of One Room Housing Through Plan of House (주택 평면을 통한 원룸 주거 공간 분석 - 사례를 중심으로 -)

  • Kim, Han-Soo
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.145-153
    • /
    • 2014
  • This study analyzes the physical environments of studio-housing and suggests alternative solutions for the problems of studio-housing. Based on solving the problems of it through previous research review, the research methods are decided on-site survey and the housing floor plan analysis. The results of this study are follows. First, parking lots make passengers uncomfortable. Narrow spaces between buildings cause problems in terms of light, ventilation, and privacy. Moreover, the short of green space makes living conditions less amenable. Second, the narrow corridors of studio-housing buildings bring about bad effects on walking and privacy. The living conditions becomes worse due to the illegal remodeling. Third, even though a multi-family housing provision for low or middle-income families is a good housing policy, new design policies or interventions are needed to make residents' behavior comfortable.