• Title/Summary/Keyword: Urban Heat Island

Search Result 340, Processing Time 0.029 seconds

A Study on Retrieval of Storage Heat Flux in Urban Area (우리나라 도심지에서의 저장열 산출에 관한 연구)

  • Lee, Darae;Kim, Honghee;Lee, Sang-Hyun;Lee, Doo-Il;Hong, Jinkyu;Hong, Je-Woo;Lee, Keunmin;Lee, Kyeong-sang;Seo, Minji;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.2_1
    • /
    • pp.301-306
    • /
    • 2018
  • Urbanization causes urban floods and urban heat island in the summer, so it is necessary to understanding the changes of the thermal environment through urban climate and energy balance. This can be explained by the energy balance, but in urban areas, unlike the typical energy balance, the storage heat flux saved in the building or artificial land cover should be considered. Since the environment of each city is different, there is a difficulty in applying the method of retrieving the storage heat flux of the previous research. Especially, most of the previous studies are focused on the overseas cities, so it is necessary to study the storage heat retrieval suitable for various land cover and building characteristics of the urban areas in Korea. Therefore, the object of this study, it is to derive the regression formula which can quantitatively retrieve the storage heat using the data of the area where various surface types exist. To this end, nonlinear regression analysis was performed using net radiation and surface temperature data as independent variables and flux tower based storage heat estimates as dependent variables. The retrieved regression coefficients were applied to each independent variable to derive the storage heat retrieval regression formula. As a result of time series analysis with flux tower based storage heat estimates, it was well simulated high peak at day time and the value at night. Moreover storage heat retrieved in this study was possible continuous retrieval than flux tower based storage heat estimates. As a result of scatter plot analysis, accuracy of retrieved storage heat was found to be significant at $50.14Wm^{-2}$ and bias $-0.94Wm^{-2}$.

A Study of Activating Urban Square's Ecological Soundness - Focusing on Gyodong Square in the City of Gangneung - (도심광장의 생태적건전성 활성화방안 - 강릉시 교동 광장을 사례로 -)

  • Kim, Ji-Youn;Kang, Seon-Hong;Cho, Tae-Dong
    • Journal of Environmental Science International
    • /
    • v.26 no.7
    • /
    • pp.837-846
    • /
    • 2017
  • This study aimed to investigate the dilapidated Fine View Square located in the city of Gangneung and analyze problems for building it into a sustainable space under an effective management plan. Further to creating an ecological base for restoring the natural circulation, a restorative method for the damaged area, a spatial assignment by the UNESCO's Man and Biosphere Programme (MAB), and an urban ecological park, we not only wanted to provide an environment that is citizen friendly, but also a practical and realizable project to connect with the various methods and programs mentioned above, while utilizing the Ministry of the Environment 's ecosystem conservation fund. In conclusion, we found that it would be possible to contribute to building an urban ecological park the Ministry of Environment proposed while restoring the lost natural circulation in Gyodong Square in the city of Gangneung and ecological soundness of the city along with the reduced heat island effect and the increased biological diversity and Ecological Soundness.

Temperature Change Analysis for Land Use Zoning Using Landsat Satellite Imagery (Landsat위성영상에 의한 용도지역 온도변화분석)

  • Jung, Gil-Sub;Koo, Seul;Yoo, Hwan-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.2
    • /
    • pp.55-61
    • /
    • 2011
  • The land use has been changed artificially and caused the result of temperature increase of city compared with the outside of city or region of park and forest. The purpose of this research is to analyze the change of the urban surface temperature with land use zoning in Jinju using Landsat TM/$ETM^+$ imagery and to provide the correlation between NDVI(Normalized Difference Vegetation Index) and urban surface temperature change. The results presented that the spatial distribution of urban surface temperature was depending on the change of NDVI values on land use zoning. Considering to the average temperature by land use zoning, industrial area was the highest temperature but green area was the lowest temperature. Also as a result of comparing the correlation between surface temperature and NDVI, the green and residential area had higher correlation values than the commercial and industrial area. These results will be played a part as one of the major factors for implementing the sustainable urban planning considering the urban heat island effect problem.

Scenario-Based Analysis on the Effects of Green Areas on the Improvement of Urban Thermal Environment (녹지 조성 시나리오에 따른 도시 열환경 개선 효과 분석)

  • Min, Jin-Kyu;Eum, Jeong-Hee;Sung, Uk-Je;Son, Jeong-Min;Kim, Ju-Eun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.6
    • /
    • pp.1-14
    • /
    • 2022
  • To alleviate the urban heat island phenomenon, this study aims to quantitatively analyze the effects of neighborhood green spaces on the improvement of the thermal environment based on detailed scenarios of five types of green spaces, including parks, pocket parks, parking lot greening, roadside planting, and rooftop-wall greening. The ENVI-met 4.4.6v model, a microclimate simulation program, was used to analyze the effects of green spaces. As a result, it was found that the air temperature decreased as the planting density of the park increased, but the thermal comfort index PET, which is the degree of heat sensation felt by humans, was not directly proportional to temperature. The establishment of a pocket park reduced air temperature up to a radius of 56m, while the range of temperature reduction increased by about 12.5% when three additional pocket parks were established at 250m intervals. Unlike the air temperature, PET was only affected in the vicinity of the planted area, so there was no significant difference in the thermal comfort of the surrounding environment due to the construction of pocket parks. Changing the surface pavement from asphalt to lawn blocks and implementing rooftop or wall greening did not directly act as solar shading but positively affected air temperature reduction; PET showed no significant difference. Roadside planting showed a higher air temperature reduction effect as the planting interval was narrower, but PET was not directly proportional to tree density. In the case of shrub planting under trees, it did not significantly affect the air temperature reduction but positively affected the improvement of thermal comfort. This study can outline strategies for constructing neighborhood green spaces to solve the urban heat island phenomena and establish detailed strategies for efficient thermal environment improvements.

Surface Micro-Climate Analysis Based on Urban Morphological Characteristics: Temperature Deviation Estimation and Evaluation (도시의 지표형태학적 특성에 기반한 지면미기후 분석: 기온추정 및 평가)

  • Yi, Chaeyeon;An, Seung Man;Kim, KyuRang;Kwon, Hyuk-gi;Min, Jae-Sik
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.445-459
    • /
    • 2016
  • Air temperature deviation (ATD) is one of major indicators to represent spatial distribution of urban heat island (UHI), which is induced from the urbanization. The purpose of this study is to evaluate the accuracy of air temperature deviation about Climate Analysis Seoul (CAS) workbench, which had developed by National Institute Meteorological Science and TU Berlin. Comparison and correlation analysis for CAS ATD including meso-scale air temperature deviation, local-scale air temperature deviation, total air temperature deviation, surface heat flux deviation, cold air production deviation among meso-scale numerical modelling variable in 'Seoul Region', micro-scale numerical modelling in 'Detail Region', and CAS workbench variable using observation data in ground stations. Comparison between night time OBS ATD and CAS ATD show that have most close values. Most of observations ($dT_{max}$ and $dT_{min}$) have highly positive ($dT_{SHP}$, $dT_{CA}$, MD, TD, $f_{BS}$, $f_{US}$, $f_{WS}$, $h_B$) and negative ($f_{VS}$, $f_{TV}$, $h_V$, Z) correlations. However, CAS workbench needs further improvement of both observational framework and analytical framework to resolve the problems; (1) night time OBS ATD of has closer values in compare with at high rise mountain area and (2) correlations are very dependable to meteorological scale.

Air Temperature Differences in Areas with High-rise Buildings (초고층빌딩지역의 기온차)

  • Jin, Wen-Cheng;Lee, Kyoo-Seock
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.12-22
    • /
    • 2012
  • In Seoul, skyscrapers are built in commercial zones known as residential-commercial complexes, which cause such environmental problems as urban heat islands(UHI) and air pollution. To investigate air temperature differences in areas near skyscrapers at Gangnam-gu, Seoul, South Korea, fixed air temperature observation and traverse observations were performed from March 16, 2008 to March 15, 2009. The annual mean air temperature at Tower Palace(TPL) was higher than that at Sookmyung Girls' High School(SMG) by $0.7^{\circ}C$, although the distance between the two observation positions is only 200m. The number of tropical nights at TPL was 13, while that at SMG was 5. The higher air temperature at TPL was due to a significantly lower sky view factor(SVF), which prevented long-wave radiation from emitting into the sky. The highest air temperature increases near TPL occurred on summer nights because of the high-electricity consumption value of $70.22Wh/m^2$ for the TPL block in August due to air conditioning for cooling. It is concluded that the warm air pocket centered on TPL.

Landscape Planning and Design Methods with Human Thermal Sensation (인간 열환경 지수(HumanThermal Sensation)를 이용한 조경계획 및 디자인 방법)

  • Park, Soo-Kuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • Human thermal sensation based on a human energy balance model was analyzed in the study areas, the Changwon and Nanaimo sites, on clear days during thesummer of 2009. The climatic input data were air temperature, relative humidity, wind speed and solar and terrestrial radiation. The most effective factors for human thermal sensation were direct beam solar radiation, building view factor and wind speed. Shaded locations had much lower thermal sensation, slightly warm, than sunny locations, very hot. Also, narrow streets in the Nanaimo site had higher thermal sensation than open spaces because of greater reflected solar radiation and terrestrial radiation from their surrounding buildings. Calm wind speed also produced much higher thermal sensation, which reduced sensible and latent heat loss from the human body. By adopting climatic factors into landscape architecture, the human thermal sensation analysis method promises to help create thermally comfortable outdoor areas. The method can also be used for urban heat island modification and climate change studies.

The Effects of Urban Stream Improving the Thermal Environment on Urban (도심하천이 도시 열 환경 완화에 미치는 영향)

  • Park, Jin-Ki;Park, Jong-Hwa;Na, Sang-Il;Beak, Shin-Chul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.760-760
    • /
    • 2012
  • 도심 지역은 인구집중, 토지 피복의 변화 및 교통량 증가 등의 인공열 배출원의 다양화 등의 요인에 의해 주변지역보다도 기온이 높은 도시 열섬(Urban Heat Island) 현상에 의해 독특한 도시기후의 특색을 보이게 된다. 일반적으로 도시 열 환경에 대한 연구는 도시 열섬의 강도나 현상을 파악하는데 집중되어 왔다. 최근 들어 도시 열섬 현상 완화 또는 개선을 위한 관심이 높아지면서 도시내에 존재하는 수면이나 녹지를 이용한 기후개선에 대한 연구가 진행되고 있다. 하천은 다양한 생물이 서식하는 공간이면서 생물의 다양성이 풍부한 생태계의 보고로 인간과 환경이 조화를 이루어 온 공간이기도 하다. 이와 같이 하천은 지역의 다양성과 특수성에 따라 가지고 있는 기능이 다양하다. 그 중 하천의 환경 기능은 많은 열용량을 축적시켜 수면의 온도상승을 적게 하여 하천의 온도는 물론 주변지역의 온도를 낮추는 역할을 하게 된다. 특히 흐르는 물은 대류와 혼합과정을 거치며 열을 운반할 수 있으므로 효율적인 축열체가 된다. 또한 하천의 물 등은 광의 투과성이 높기 때문에 표면에서는 반사되지 않고 수체 내에 열을 저장한다. 따라서 이러한 현상이 종합적으로 작용하여 도심하천은 도심지에서 높게 형성된 온도를 낮추는 냉각효과가 있다고 판단된다. 이러한 영향을 알아보기 위해 본 연구에서는 원격탐사 기법을 이용하여 도심하천이 도시 열완경 완화에 미치는 영향을 분석하였다. 분석을 위해 2009년 9월 6일 Landsat 7 ETM+ 위성영상을 이용하여 LST (Land Surface Temperature)를 추출하고, SEBAL (Surface Energy Balance Algori- thms for Land) 모델을 이용하여 지표면 열수지 성분을 추출하였다. 그 결과, 도심하천 주변의 온도가 도심지에 비해 $2{\sim}3^{\circ}C$ 정도 낮게 형성되었으며, 잠열은 주변 도심지에 비해 하천에서 높은 분포를 나타내었다. 그러나 하천 둔치나 하천 주변의 콘크리트, 아스팔트 및 나대지 등의 토지피복은 지표면 온도가 높게 형성되어 도심의 heat spot으로 작용하여 열 환경을 악화시키나 도심하천은 cool spot 작용을 하여 도심의 열을 완화하는 기능을 갖는 것으로 판단된다.

  • PDF

Effect of an Urban Thermal Environment on the Air Quality in Two Cities

  • Lee, Kwi-Ok;Lee, Hwa-Woon;Lee, Hyun-Ju;Park, Jong-Kil;Jung, Woo-Sik
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.29-40
    • /
    • 2011
  • In this study, the effects of an urban thermal environment on air quality were investigated using hourly surface weather observation data and air quality data over six summers from 2000 to 2005 in two cities on the Korean Peninsula. One, the city of Daegu, is representative of basin topography and the other, the city of Busan, represents a coastal area. It is known that the characteristics of an urban thermal environment are represented as an "urban heat island". Here, we focus on the nighttime urban thermal environment, which is called a "tropical night", during the summer. On tropical nights in Busan, the temperature and cloud cover levels were higher than on non-tropical nights. Wind speed did not appear to make a difference even on a tropical night. However, the frequency of southwestern winds from the sea was higher during tropical nights. The prevailing southwest winds in all areas meant an inflow of air from the sea. So at most of the air quality stations, the ozone concentration during tropical nights was lower than during non-tropical nights. In Daegu, the tropical nights had higher temperatures and cloud covers. Despite these higher temperatures, the ozone concentration during the tropical nights was lower than that on non-tropical nights at most of the air quality stations. This feature was caused by low irradiance, which in turn caused an increased cloud cover. Wind speed was stronger during the tropical nights and dispersed the air pollutants. These meteorological characteristics of the tropical nights reduced ozone concentrations in the Daegu Basin.

The Quantitative Analysis of Cooling Effect by Urban Forests in Summer (여름철 도시 인근 산림에 의한 냉각효과의 정량화에 대한 연구)

  • Lee, Hojin;Cho, Seongsik;Kang, Minseok;Kim, Joon;Lee, Hoontaek;Lee, Minsu;Jeon, Jihyeon;Yi, Chaeyeon;Janicke, Britta;Cho, Changbeom;Kim, Kyu Rang;Kim, Baekjo;Kim, Hyunseok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.73-87
    • /
    • 2018
  • A variety of micro meteorological variables such as air temperature, wind, solar radiation and latent heat at Gwangneung forests (conifer and broadleaved forests) and AWS (Automated Weather Station) of Pocheon urban area were used to quantify the air temperature reduction effect of forests, which is considered to be an eco-friendly solution for reducing the urban heat island intensity during summer. In June, July and August of 2016 and 2017, the average maximum air temperature differences between above and below canopy of forests, and between the forests and urban areas were $-1.9^{\circ}C$ and $-3.4^{\circ}C$ respectively, and they occurred at 17:00. However, there was no difference between conifer and broadleaved forests. The effect of air temperature reduction by the forests was positively correlated with accumulated evapotranspiration and solar radiation from 14:00 to 17:00 and showed a negative correlation with wind speed. We have developed a model to quantify the effect of air temperature reduction by forests using these variables. The nighttime air temperature reduction effect by forests was due to the generation of cold air from radiative cooling and the air temperature inversion phenomenon that occurs when the generated cold air moves down the side of mountain. The model was evaluated in Seoul by using 28 AWSs. The evaluation shows that the air temperature of each district in Seoul was negatively correlated with the area and size of the surrounding tall vegetation that drives vegetation evapotranspiration during the day. During the night, however, the size of the surrounding tall vegetation and the elevations of nearby mountains were the main influencing factors on the air temperature. Our research emphasizes the importance of the establishment and management of urban forests and the composition of wind roads from mountains for urban air temperature reduction.