• Title/Summary/Keyword: Urban Gas

Search Result 414, Processing Time 0.027 seconds

Strain demand prediction of buried steel pipeline at strike-slip fault crossings: A surrogate model approach

  • Xie, Junyao;Zhang, Lu;Zheng, Qian;Liu, Xiaoben;Dubljevic, Stevan;Zhang, Hong
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.109-122
    • /
    • 2021
  • Significant progress in the oil and gas industry advances the application of pipeline into an intelligent era, which poses rigorous requirements on pipeline safety, reliability, and maintainability, especially when crossing seismic zones. In general, strike-slip faults are prone to induce large deformation leading to local buckling and global rupture eventually. To evaluate the performance and safety of pipelines in this situation, numerical simulations are proved to be a relatively accurate and reliable technique based on the built-in physical models and advanced grid technology. However, the computational cost is prohibitive, so one has to wait for a long time to attain a calculation result for complex large-scale pipelines. In this manuscript, an efficient and accurate surrogate model based on machine learning is proposed for strain demand prediction of buried X80 pipelines subjected to strike-slip faults. Specifically, the support vector regression model serves as a surrogate model to learn the high-dimensional nonlinear relationship which maps multiple input variables, including pipe geometries, internal pressures, and strike-slip displacements, to output variables (namely tensile strains and compressive strains). The effectiveness and efficiency of the proposed method are validated by numerical studies considering different effects caused by structural sizes, internal pressure, and strike-slip movements.

Excess Pore Water Pressure Calculation Methods due to Gas Hydrate Dissociation (가스 하이드레이트의 해리로 발생하는 간극수압의 계산방법)

  • Park, Sung-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.888-892
    • /
    • 2008
  • If gas hydrate dissociates due to natural and/or human activities, it generates large amount of gas and water. Upon gas hydrate dissociation, a generated pore water pressure between soil particles increases and results in the loss of an effective stress and degradation of soil stiffness and strength. In order to predict the generated excess pore water pressure due to gas hydrate dissociation, two methods based on small hydrate concept (SHC) and large hydrate concept (LHC) are proposed. An excess pore water pressure generated by the gas hydrate dissociation in the Storegga Slide was calculated using two proposed methods.

  • PDF

Gasification of Woody Waste in a Two-Stage Fluidized Bed Varying the Upper-reactor Temperature and Equivalence Ratio (상부온도(上部溫度)와 공기비(空氣比) 변화(變化)에 따른 폐목재(廢木材)의 이단(二段) 유동층(流動層)가스화(化))

  • Mun, Tae-Young;Kim, Jin-O;Kim, Jin-Won;Kim, Joo-Sik
    • Resources Recycling
    • /
    • v.19 no.2
    • /
    • pp.45-53
    • /
    • 2010
  • During the biomass gasification, tar generation is typically accompanied, which causes many problems, such as pipe plugging and equipment fouling. In the experiments, activated carbon was applied to the upper reactor of the two-stage gasifier in order to remove the tar generated during gasification. In addition, the effects of the upper-reactor temperature and equivalence ratio on the producer gas characteristics (composition, tar content and lower heating value) were investigated. To investigate the effect of the upper reactor-temperature, experiments were performed at 743, 793, $838^{\circ}C$, respectively. To examine the influence of the equivalence ratio, a comparison experiment was carried out at a equivalence ratio of 0.17. In all experiments, tar contents in the producer gases were below $2mg/Nm^3$. The maximum LHV of the producer gas was above $10MJ/Nm^3$, which is much higher than the typical LHV($3\sim6MJ/Nm^3$) in the air gasification of biomass.

Development of a Biogas Engine for Cogeneration System (바이오스가스를 이용한 열병합 발전용 엔진 개발)

  • Kim, Yeong-Min;Lee, Jang-Hui;Ju, Seong-Ho
    • 연구논문집
    • /
    • s.30
    • /
    • pp.33-42
    • /
    • 2000
  • We must stabilize quickly increasing waste matters in urban life and livestock industry. Biogas including landfill gas and digester gas is byproduct of anaerobic decomposition of organic waste matter and contains 40%-70% methane, which can be used for energy purposes. Utilization of biogas reduce the emission of methane into the atmosphere to minimize greenhouse effect and the carbon dioxide (CO2) emitted when biogas is converted to energy has been taken out of the atmosphere by growing plant. Recently, bioenergy is world-widely noticeable as all contributing to the greenhouse effect. This paper presents development process of a biogas engine for cogeneration system and results of application to digester gas and landfill gas in site. The biogas engine is a dual fuel engine operated on biogas with a diesel pilot. At present, the engine can substitute biogas for diesel fuel up to 85%. but it can be said that there is a possibility of improvement in performance.

  • PDF

Physio-Ecological Characteristics of Roadside Tree by Difference under Zoning of Urban Districts in Cheong-ju City -Focused on the Ginkgo biloba and Platanus orientalis- (청주시 용도지역별 가로수의 생리.생태학적 특성에 관한 연구 -Ginkgo biloba와 Platanus orientalis를 중심으로-)

  • In, Hyoung-Min;Ju, Jin-Hee;Yoon, Young-Han
    • Journal of Environmental Science International
    • /
    • v.19 no.2
    • /
    • pp.229-236
    • /
    • 2010
  • As air pollution has emerged as one of the most pressing urban environmental concerns, many studies have investigated the influence of air pollutants(ex: $O^3$, $NO^2$, $SO^2$, Acid rain, etc.) on roadside trees and urban grove. In Korea, population density started to increase since the industrialization. Since dense population aggravates our living conditions, it's very important for us to preserve and keep a lively and refreshing nature in order to live with green nature in harmony under the current artificial environment-dominating world. In metropolitan cities, the production of pollutants increases in proportion to population growth. The vehicle exhaust gas and air pollutants from cooling and heating systems have been the major causes of acid rain. Furthermore, tire particles which are naturally produced by tire wearing on roads and other toxic substances in exhaust gas have caused a problem in human health directly and indirectly. In fact, a lot of studies have analyzed air pollution, roadside trees and plants in Korea. However, they are mostly limited to covering the influence of air pollution on the growth of plants. No paper has clearly explained why air pollution-resistant or-vulnerable species has shown different reactions yet. Even though a lot of urban roadside trees have died or stopped to grow from time to time, this kind of problem has not been properly examined. This paper is aimed to comparatively analyze physio-ecological characteristic such as photosynthesis, chlorophyll contents, soil volume water figure out their relationship with environmental factors against the expanding roadside trees in Cheong-ju, and provide basic data for management of roadside trees and elaboration of urban environment preservation policies.

Design of CIM(Common Information Model) Profile for Smart City Energy Monitoring (스마트시티 에너지 감시를 위한 CIM(Common Information Model) 프로파일 설계)

  • Youngil, Kim;Changhun, Chae;Yeri, Kim;Jihoon, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.127-135
    • /
    • 2022
  • With the advent of high technologies such as the 4th Industrial Revolution and artificial intelligence and big data, efforts are being made to solve urban problems and improve the quality of life by applying new technologies in the smart city field. In addition, as carbon neutrality has emerged as an important issue due to global warming, smart city energy platform technologies such as urban energy management, efficiency improvement, and carbon reduction are in the spotlight. In order to effectively manage urban energy, energy resource information such as electricity, water, gas, hot water, heating, etc. must be collected from the management system of various energy utilities and managed on the central platform. The centrally integrated data is delivered to external city management systems that require city energy information through an energy platform. This study developed a CIM profile for smart city energy monitoring required to provide energy data to external systems. Electric data model were designed using the CIM class of IEC 61970, and water, gas, and heat data model were designed in compliance with the UML-based design ideas of IEC 61970.

A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis (가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구)

  • Ah-Reum, Kim;Byeong Sub, Kwak;Tae-Hyun, Jun;Hyun-joo, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

Suggestions for the Estimation of the Methane Emission from a Landfill Site

  • Lee, Kyungho;Jeon, Eunjeong;Lee, Youngmin;Park, Junghyun
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.69-73
    • /
    • 2020
  • Sudokwon landfill("Sudokwon" means regions of Seoul, Kyunggi and Incheon metropolitan cities in Korea), the world's largest sanitary landfill, has been systematically managing statistics on the incoming and dumping wastes and satisfactorily controlling pollutants including leachate and LFG. According to our long time experience of LFG field monitoring, the emission of GHG from landfill estimated by the IPCC Guideline showed much difference with our results. C&D waste has high concentration of sulfate compared to other wastes. Increased C&D waste of dumping waste had changed the COD/sulfate ratio in the landfill, which caused the increase of H2S gas and the decrease of CH4 gas. But the IPCC estimation method does not consider the effects of sulfate. In addition to that, the oxidation factor of the cover soil is set to the default values of 0.1 but the measured values by the field monitoring, are showing much higher than that, especially in the closed landfill.

Abnormal Resonance Noise Phenomenon and Effect through Exhaust Gas Passageway in Urban Combined Power Plant (도심지 복합화력 배가스 통로에서의 이상 소음 현상과 영향)

  • Kim, Yeon-Whan;Lee, Young-Shin;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.866-869
    • /
    • 2004
  • Power transformers, air-intakes and stacks in the urban combined power plant are main noisy sources. Because of Inhabitant complaint by abnormal noise transferred from the power plant. the noise was investigated at power plant and uptown area. The result of diagnosis made the acoustic resonance phenomenon by 580Hz's combustion dynamic pressure with the standing wave mode of sound fields in exhaust passageway of gas turbine into main noise source of public complain. The abnormal noise is caused by the resonance exhaust noise transferred through stacks of power plant.

  • PDF

Comparison of pollutant removal efficiency according to the locations of the supply and exhaust (격리병실내 급배기구 위치에 따른 오염물 제거효율 비교)

  • Won, An-Na
    • Journal of Urban Science
    • /
    • v.9 no.2
    • /
    • pp.13-20
    • /
    • 2020
  • The Recently, several countries have been affected by respiratory diseases, resulting in renewed research interest in their prevention and control. One such example was the 2015 outbreak of Middle East Respiratory Syndrome (MERS) in South Korea and COVID-19. In this study, we performed experiments and simulations based on concentration decay using CO2 as the tracer gas to elucidate the pollutant-removal efficiency for different inlet and exhaust locations and outdoor air-supply ratios. The wall inlet exhibited a higher pollutant-removal efficiency, owing to the upward movement of the air from the lower zone to the upper one. In conclusion, it is recommended that a total air-conditioning plan for isolation rooms be established as well as efficient system operation for pollutant removal and air-flow control to prevent the transmission of infections from the patients to others.