• Title/Summary/Keyword: Urban Block

Search Result 256, Processing Time 0.024 seconds

Study on the Proper Separation Distance from Intersection to Bus Stop for Reducing Traffic Accidents (교통사고 감소를 위한 교차로에서 버스정류장간 적정 이격거리 산정 연구)

  • Eom, Daelyoung;Chae, HeeChul;Park, Wonil;Yun, llsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.2
    • /
    • pp.1-16
    • /
    • 2022
  • The location of the bus stop on urban roads should be installed at a point where it is convenient for users and the impact of bus stops on the traffic flow is minimized. However, the location of the bus stops is determined indiscriminately due to the lack of related research. Therefore, this study developed a traffic accident prediction model and calculated the proper separation distance for the bus stops through an optimization technique. The result of the study indicates that the bus stop can be installed in the form of a mid-block approximately 87 to 166 m away from the intersection in the road section. This result is valid if the number of main road lanes in the road section is 2 to 4 with a level of traffic from 1,000 to 3,000 v/h. In the section with 5 to 6 lanes, it is desirable to install a bus stop close to the intersection by about 42 to 97 m.

A Study on the Damage Evaluation of Polyethylene Pipe by Squeeze-off (스퀴즈오프에 따른 PE배관의 손상평가 연구)

  • Ho seong Seo;Hwa young Lee;Jae-hun Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.1-6
    • /
    • 2023
  • PE piping, which has advantages in terms of construction convenience and economy, is widely used for underground burial in the domestic urban gas field. These PE pipes use squeeze-off in many sites to block gas flow during maintenance and repair work. Squeeze-off refers to a method of compressing a PE pipe to block fluid flow, and damage may occur due to the nature of construction in which the pipe is deformed by physical force. In order to prevent damage to PE pipes due to squeeze-off, the main points to be reflected in the squeeze-off operation procedures such as proper compression range, use pressure, and diameter were derived through damage assessment and confidential test according to the compression rate. The compression experiment for PE pipe damage assessment was conducted while changing the compression rate (20%~40%), the pressure of use (2.8 kPa, 25 kPa, 70 kPa), and the pipe diameters (63 mm, 90 mm, 110 mm). As a result of damage assessment according to the compression rate, damage occurred in pipes with compression rates of 45%(110mm) and 73%(63mm), which are for analyzing the effect of excessive compression. In addition, the leakage test was conducted using Ar(argon) during the squeeze-off, and as a result of the experiment, leakage occurred under the conditions of 70kPa and 110mm of pipe. As a result of this study, it was confirmed that squeeze-off for airtightness should be carried out in pipes within a range not exceeding 25 kPa and 90 mm pipes, and the appropriate compression rate to prevent damage to PE pipes is 30%.

A Study on the Behavioral Characteristics of the Users and Preferences of the Bench and Pergolas in Busan Citizens' Parks (부산시민공원의 벤치 및 파고라 이용자 행태 특성 및 선호도 연구)

  • Wang, Dan;Yoon, Ji-Young
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.658-670
    • /
    • 2018
  • Busan Citizen Park has been taken as the research object in this paper to learn about the categories and types of resting facilities such as seats and Pergolas in the park and analyze the visitors' use patterns of bench and Pergolas. In addition, the analysis of the cultural features and preferences of bench and Pergolas will provide the basic data for the future design of resting facilities. After the research on the categories and types of bench and Pergolas and the evaluation factors through literature surveys, the type, location, and number of resting facilities including bench, Pergolas, sheds, etc. in the entire park have been investigated through field surveys. In addition, the behavioral map analysis has been created through the observation of the use patterns of bench and Pergolas in the morning and afternoon of each month, and the degree of preference and satisfaction of park bench and Pergolas has been grasped through questionnaires. The research results are as follows. Among the ten types of bench and Pergolas, the citizens like the mats and awnings + mats best. The environment is the most important factor for the mats with highest score, followed by the functional and regional factors. In addition, various activities such as eating in mats and sheds that block sunlight are Korean use patterns, which is very common in Korean daily life. These results show that bench and Pergolas in urban parks are not placed arbitrarily and the layout and design of bench and Pergolas should be completed based on behavior and preferences, which are influenced by cultural characteristics.

A Study on the Damage level of Pavement For The Landscape Urban Community Parks - In case of Dukjin, Choongang, and Dosan Park - (도시 근린 공원내 조경 포장면의 손상 정도에 관한 연구 -덕진(전주), 중앙(청주), 도산(서울) 공원을 중심으로-)

  • 신병철;권상준
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.24 no.3
    • /
    • pp.96-108
    • /
    • 1996
  • This study aimed at choosing the urban community parks such as D Kjin, Chungang, Dosan Park as the target place for this study, and at analyzing the damage level of the pavement surfaces focusing on the spaces and the materials. We devided the damage level within $1.5\times$1.5m grid int the grade from one to five points, and made use of the method of giving marks to get hold of the damage level of the pavement surfaces. Especially we took and analyze Duncan test for the spaces suffering severe damage. The result is as follows : 1. The damage of unenenness turned out to be a most excessive damage in the damage level according to the pavement materials in case of D kjin, and Chunggnag Park. Especially the concrete blocks proved to be the exessive damage in comparison with the other pavement materials, and the demolitional damage of the damage types to the most severe damage. The corner damage turned relatively out to be a heavy damage in case of Dosan Park in Seoul. 2. In the event of the damage level of pavement surfaces according to the spaces, the space which was made the more use of and which was the more concentrated, turned out to be the degree of the more excessive damage. 3. We took the Duncan test to verify the deference of the damage type between the spaces and the pavement materials of the target places for survey. The result of verification was that there was no difference of the damage type between the corner and block damage itself in case of the enterance area and the square of D kjin Park in Ch nju, and that the damage level of the pavement materials proved to be the more execssive damage than that of the spaces. The corner damage of Chungang Park in Hj ngju, showed the same result as D kjin Park in Ch nju and the uneveness didn't have any difference of damage type in all spaces. In case of Dosan in Seoul, the damage of crevice, demolition, and pumping didn't have any difference of damage type and the damage of the cross area was the most high. In conclusion, we proposed that we should get hold of whether the cause of pavement damage is caused by the defect of materials of by the construction problem including the foundation, or the unsuitableness of the method for using the pavement materials, and also that we should take a sensus of the user type and should decide a suitable design load and the necessary thickness of the pavement materials. In this study, not only we aimed at the external damage of the materials, but we tried to propose rather reasonable and developed construction method by studying the material experiment, the foundation state, and the type of using the spaces and materials, and by examining into the fundamental damaged cause.

  • PDF

Assessing the Positioning Accuracy of High density Point Clouds produced from Rotary Wing Quadrocopter Unmanned Aerial System based Imagery (회전익 UAS 영상기반 고밀도 측점자료의 위치 정확도 평가)

  • Lee, Yong Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.39-48
    • /
    • 2015
  • Lately, Unmanned Aerial Vehicles(UAV), Unmanned Aerial Systems(UAS) or also often known as drones, as a data acquisition platform and as a measurement instrument are becoming attractive for many photogrammetric surveying applications, especially generation of the high density point clouds(HDPC). This paper presents the performance evaluation of a low-cost rotary wing quadrocopter UAS for generation of the HDPC in a test bed environment. Its performance was assessed by comparing the coordinates of UAS based HDPC to the results of Network RTK GNSS surveying with 62 ground check points. The results indicate that the position RMSE of the check points are ${\sigma}_H={\pm}0.102m$ in Horizonatal plane, and ${\sigma}_V={\pm}0.209m$ in vertical, and the maxium deviation of Elevation was 0.570m within block area of ortho-photo mosaic. Therefore the required level of accuracy at NGII for production of ortho-images mosaic at a scale of 1:1000 was reached, UAS based imagery was found to make use of it to update scale 1:1000 map. And also, since this results are less than or equal to the required level in working rule agreement for airborne laser scanning surveying of NGII for Digital Elevation Model generation of grids $1m{\times}1m$ and 1:1000 scale, could be applied with production of topographic map and ortho-image mosaic at a scale of 1:1000~1:2500 over small-scale areas.

Evaluation of Strain Distribution and Pullout Strength based on Width and Horizontal Spacing of Geosynthetic Strip (띠형 섬유보강재의 폭과 설치간격에 따른 변형률 분포 및 인발강도 특성 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.2
    • /
    • pp.39-47
    • /
    • 2012
  • This paper describes large-scale pullout test results of geosynthetic strip, which can be applied in reinforced earth wall with block-type wall facing. The pullout tests are conducted to evaluate the strain distribution, the induced pullout force and the pullout strength. The maximum pullout force is appeared regardless of reinforcement width and normal stress when end displacement is less than 15 mm. The pullout behavior based on horizontal spacing of reinforcement was similar in relationship between pullout force and end displacement. The strain distribution and pullout force distribution of the geosynthetic strip are concentrated in the front part of reinforcement, and it appeared clearly in higher normal stress condition This means that the pullout behavior of geosynthetic strip is affected by the bond between soil and friction resistance reinforcement according normal stress. Therefore, the pullout resistance design is reasonable when pullout behavior of geosynthetic strip should be evaluated by effective length considering tensile characteristic.

Urban Nonpoint Source Pollution Assessment Using A Geographical Information System (GIS를 이용한 도심지 Nonpoint Source 오염 물질의 평가연구)

  • ;Stephen J. Ventura;Paul M. Harris;Peter G. Thum;Jeffrey Prey
    • Spatial Information Research
    • /
    • v.1 no.1
    • /
    • pp.39-53
    • /
    • 1993
  • A geographical information systems(GIS) was a useful aid in the assessment of urban nonpoint source pollution and the development of a pollution control strategy. The GIS was used for data integration and display, and to provide data for a nonpoint source model. An empirical nonpoint source loading model driven by land use was used to estimate pollutant loadings of priority pollutant. Pollutant loadings were estimated at fine spatial resolution and aggregated to storm sewer drainage basins(sewershedsl. Eleven sewersheds were generated from digital versions of sewer maps. The pollutant loadings of individual land use polygons, derived as the unit of analysis from street blocks, were aggregated to get total pollutant loading within each sewershed. Based on the model output, a critical sewershed was located. Pollutant loadings at major sewer junctions within the critical sewershed were estimated to develop a mi t igat ion strategy. Two approaches based on the installat ion of wet ponds were investigated -- a regional approach using one large wet pond at the major sewer outfall and a multi-site approach using a number of smaller sites for each major sewer junction. Cost analysis showed that the regional approach would be more cost effective, though it would provide less pollution control.

  • PDF

Suggestion of Ocher Color Standards for Cement-Composites used on the Sidewalk (보도에 사용되는 시멘트복합체에 대한 황토색 표준의 제시)

  • Chung, Chul-Woo;Lee, Jae-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • This work aims to suggest the most proper Hwangtoh color(ocher) for sidewalks and walkways located at the central part of the city. The actual colors of Hwangtoh samples that were obtained from 3 different locations (mountain walkways) in Busan were measured. In addition, personal preferences of such Hwangtoh colors were evaluated through survey in order to provide a proper standard reference color for urban walkways and sidewalks. With respect to the chromaticity of Hwangtoh obtained in Busan, $a^*$ and $b^*$ values were found to range from 3.6 to 13.6 and 11.4 to 23.4, respectively. It was also found that $L^*$ (lightness) values of 3 different Hwangtoh samples were found to be similar. According to the results from survey, higher values of $+a^*$ (red type) and $+b^*$ (yellow type) were preferred, indicating the red and yellow color needs to be developed stronger from Hwangtoh. Based on these findings, the proper Hwangtoh color used for walkways in urban area was chosen. It was found to be $L^*$ for 32.2~45.8, $a^*$ for 5.2~13.6, and $b^*$ for 15.8~21.2, respectively.

Location Analysis for Public Sector's Development of Mixed-Use Complex (입체복합개발을 위한 공공 입지여건 분석)

  • Yoon, Jeong-Joong;Lee, Duk-Bok
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.117-126
    • /
    • 2012
  • The purpose of this paper is to analysis spatial locations for public sector's development of mixed-use complex. The results of analysis of location characteristics and public sector's participation conditions are as follows. The central commercial district of new town, surroundings of new railway station, and old town center are likely to be appropriate in the case of a functional mixed-use considering acceptable use in accord with mixed-use complex. Development potential is also high at places such as railway adjacent area in old town and relocation of downtown improper facilities including previous three cases. And development of various size such as lot, block and district can be applied at central commercial district of new town, center and subcenter of old town, surroundings of new railway station. The result of analysis of public sector's participation conditions is appropriate in central commercial district of new town by public sector, relocation of downtown improper facilities and old site of transferring public facilities. They can be contribute to grow up new town by public-private partnership and to improve urban circumstances and publicness by development old site coupled with new site of transferring public facilities.

Characteristics of Unsold Land and Sites Needing Value Enhancement (미매각 토지의 원인진단 및 가치제고 사업지구 선정 방안)

  • Jeong, Yeun-Woo;Lee, Sang-Jun;Seong, Jang-Hwan
    • Land and Housing Review
    • /
    • v.4 no.3
    • /
    • pp.259-270
    • /
    • 2013
  • This paper defined the concept of unsold land and diagnosed the cause of unsold land of LH business site. The results are showing as follows. First, unsold land is defined as land could not be sold until the completion of the project, and plan to sell the unsold land can be changed partially. Second, the status of unsold land in the 226 project sites were analyzed. $146km^2$ area corresponding to 74.8% of the total capital area($195km^2$) are unsold. By purpose, co-residential($38km^2$), industry($21km^2$), exclusive residential($16.4km^2$), commercial business($12.5km^2$), education($10.2km^2$) was larger in order. Third, value enhancement target project sites were selected and its symptoms and the cause of unsold land were analyzed. For the project site over average unsold rate, 6 sites located in province and 2 sites located in capital region were selected through collecting the practitioners and expert opinion. These 8 sites are characterized that sale of land for medium and large co-residential, urban support facilities, block-shaped house and attached house was inactive. Also, these sites commonly experienced economic fluctuations, changes in market demand, supply and demand mismatch, inflexible planning standards.