• 제목/요약/키워드: Urban Air pollutants

검색결과 207건 처리시간 0.025초

아파트 단지내의 열섬효과가 대기오염물질 확산에 미치는 영향 해석을 위한 열유동장 수치모의 (A Numerical Simulation of Heat Flow Field for Heat Island Effect Analysis to Air Pollutants Dispersion in Apartment Complex)

  • 장은숙
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.577-582
    • /
    • 2005
  • Enormous apartment complexes in urban areas, temporary inversion state and heat island effect occur due to the strong sunshine and weak wind speeds which hinders the dispersion of air pollutants that are emitted from neighboring areas of apartment complexes. In this study, analysis were conducted by using the Fluent code based on the CFD(Computation Fluid Dynamics), including building layout, material, building height from the ground surface, the heat, analysis of flow field in the apartment complex. It was estimated that the temporal radiation inversion phenomenon during the daytime, which was caused by the weak wind speed and higher temperatures in the upper level, contributed to the stagnation of the air pollutants in the lower layer of the apartment complex.

도시 협곡에서 건물 지붕 냉각이 스칼라 물질 확산에 미치는 영향 (Effects of Building-roof Cooling on Scalar Dispersion in Urban Street Canyons)

  • 박수진;김재진
    • 대기
    • /
    • 제24권3호
    • /
    • pp.331-341
    • /
    • 2014
  • In this study, the effects of building-roof cooling on scalar dispersion in three-dimensional street canyons are investigated using a computational fluid dynamics (CFD) model. For this, surface temperature of building roof is systematically changed and non-reactive pollutants are released from street bottom in urban street canyons with the aspect ratio of 1. The characteristics of flow, air temperature, and non-reactive pollutant dispersion in the control experiment are analyzed first. Then, the effects of building-roof cooling are investigated by comparing the results with those in the control experiment. In the control experiment, a portal vortex which is a secondary flow induced by ambient air flow is formed in each street canyon. Averaged air temperature is higher inside the street canyon than in both sides of the street canyon, because warmer air is coming into the street canyon from the roof level. However, air temperature near the street bottom is lower inside the street canyon due to the inflow of cooler air from both sides of the street canyon. As building-roof temperature decreases, wind speed at the roof level increases and portal vortex becomes intensified (that is, downdraft, reverse flow, and updraft becomes stronger). Building-roof cooling contributes to the reduction of average concentration of the non-reactive pollutants and average air temperature in the street canyon. The results imply that building-roof cooling has positive effects on improvement of thermal environment and air quality in urban areas.

부산지역에서의 대기흐름과 관련된 $SO_2$농도 3차원 수치모의 (A Three Dimensional Numerical Simulation of $SO_2$ Concentration in Relation with Atmospheric Flow in Pusan Area, Korea)

  • 장은숙;이화운
    • 한국환경과학회지
    • /
    • 제6권4호
    • /
    • pp.359-367
    • /
    • 1997
  • The Characteristics of atmospheric flow and dispersion of air pollutants in the mountainous coastal area were studied using three-dimensional model by the combination of land/sea breezes and transport. It was then applied to Pusan city. As the urban area considered In this study is located in a mountainous coastal area, the atmospheric flow is strongly affected by the land/sea breezes and mountain/valley winds. The typical effects of land/sea breezes on the dispersion and the characteristics of pollutants movement in the region were analysed. The model has been proved to be an useful tool to prodict real time air pollutants transport as shown by the results of application studies In Pusan, Korea which Is an urbanized coastal area with mountainous topography. It was found that the pollutants are differently transported and concentrated as going Inland by the Influence of the sea breeze with topographic changes. By comparing the pollutants concentrations of the stimulated results with those of the observational results, It is shown that stimulated results in this study are in qualitative agreement with observational ones.

  • PDF

대구지역의 국지순환풍의 환기경로 및 대기오염수송에 관한 수치모의 (Numerical Simulation on the Wind Ventilation Lane and Air Pollutants Transport due to Local Circulation Winds in Daegu Districts)

  • 구현숙;김해동
    • 한국지구과학회지
    • /
    • 제25권6호
    • /
    • pp.418-427
    • /
    • 2004
  • 최근 도시기후를 고려한 도시계획이 많은 나라에서 실용화되고 있다. 도시기후의 고려는 주로 도시의 바람 길 조성이라는 개념으로 구체화되고 있다. 도시의 바람 길 조성은 주로 하계에 도시지역의 열적 쾌적성을 개선하는 것을 목표로 한다. 아울러, 과학적 조사에 근거하여 도시의 단지계획을 합리적으로 함으로써 청정한 냉기류의 도심유입을 원활히 하여 도심의 대기오염을 저감하고자 하는 것도 목적으로 한다. 이 연구에서는, 수치실험을 통하여 전형적인 난후기일을 대상으로 대구지역의 국지순환풍이 지나는 바람의 길을 조사하였다. 그리고 이 바람에 의한 대기오염의 수송도 조사하였다. 수치실험에 사용한 모형은 RAMS(지역규모 대기모델)이다. 수치실험의 관심지역은 대구광역시 일대(약900$km^2$)이다. 수평규모는 약 30km이다. 수치실험은 일반풍이 약하고 쾌청한 일기조건을 갖는 늦봄의 기상조건 하에서 수행되었다. 수치실험의 결과 다음과 같은 3가지 결과를 얻었다: (1) 대구의 대표적 산지인 팔공산과 앞산에서 야간에 산정에서 복사냉각으로 생성된 국지풍이 지나는 길을 발견할 수 있었다. 그 바람은 대구의 동쪽 지역에서 중력류의 형태로 계곡을 따라서 흘러내렸다. (2) 평지에서는, 그 바람이 대구의 중심지를 지나 서쪽으로 흘러갔다. (3) 그 결과로, 대기오염물질은 야간에 국지풍에 의해 서쪽지역으로 수송되어졌다.

차량 운전자의 공기오염물질 잠재적 노출 및 차량용 공기청정기에 의한 제어 (Potential Exposure to Air Pollutants for Driver and Its Control Using Commercial Air Cleaning Device Inside Vehicle)

  • 김대원;김문현;양원호
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.481-486
    • /
    • 2004
  • Vehicle occupant exposure to air pollutants has been a subject of concern in recent years because of higher levels of air pollutants inside gasoline or diesel-using vehicle, comparing to the surrounding atmosphere. Contrary to previous studies, fuel of vehicles operated in this study was liquefied petroleum gas (LPG). This study examined the potential exposure and removal efficiency of selected volatile organic compounds (VOCs), nitrogen dioxide ($NO_2$) and respirable suspended particle (RSP) by commercial air cleaning device inside vehicle under different ventilation conditions. Vehicle concentrations inside of benzene, toluene, m,p-xylene, $NO_2$ and RSP were lower under the low ventilation condition. This was indicated that outdoor air pollutants could affect the vehicle air quality inside in case metropolitan cities such as Daegu. The urban vehicle concentrations inside of benzene, toluene, m,p-xylene, $NO_2$ and RSP with air cleaning device were higher than those without air cleaning device. This means that the use of air cleaning device equipped with activated carbon filter, which was used in this study, in the interior of vehicles could be expected to reduce the vehicle occupants exposure to air pollutants effectively. In batch type reactor of laboratory scale, removal efficiencies of air cleaning device used were $97.0\%,\;95.7\%,\;94.6\%\;and\;85.5\%$ respectively in benzene, toluene, m,p-xylene and $NO_2$.

우리나라 이동오염원의 제어기술의 동향과 발전방안 (Air Pollutants Control Technique Trends for Transportation Sources in Korea)

  • 김정수;엄명도
    • 한국대기환경학회지
    • /
    • 제29권4호
    • /
    • pp.477-485
    • /
    • 2013
  • The major source of harmful air pollutants in Korea have been shifted as economy grows. Particulate matter(PM) and Sulfur dioxide ($SO_2$) emitted from industries and coal-fired domestic sectors were important pollutants in 1970's and later industrializing period of Korea. Then the characteristic of pollution was changed into so-called "developed country type pollution". Vehicles have been responsible for significant amount of Nitric oxide ($NO_x$) pollution and consequent Ozone formation in urban area since 1990's. Variety of control measures have been introduced to deal with the vehicle emissions in Seoul Metropolitan Area (SMA). Emission control technologies have successfully reduced pollutants from vehicles. Three-way catalyst for vehicles fueled by gasoline and liquefied petroleum gas (LPG), for example, has achieved large amount of pollutants. Compressed natural gas (CNG) urban bus have penetrated existing diesel bus market and reduces PM and $NO_x$ emissions in many Korean cities. However, diesel vehicles are still reaming as a critical emission source of urban area. Diesel vehicles gain more popularity than ever because of their better fuel efficiency and driving power. Unfortunately, it is widely known that the pollutant emissions of diesel vehicles are much larger than those of gasoline and LPG vehicles. In this note, we briefly introduce the trends of emission control strategies which are accomplished by automotive industries for about last ten years. Emission regulation, cleaner fuel, diesel particulate filter (DPF) and other measures are discussed from technical as well as legislative perspectives.

대규모 도시개발사업에 대한 대기질 평가 사례 연구 (A Case Study on the Air Quality Impact Assessment for the Large Scale Urban Development)

  • 김상목;이상훈;박근형;우재균;구윤서;김성태;한진석
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.381-391
    • /
    • 2007
  • The air quality modeling was carried out to assess the impact of air quality for large scale urban development. The site for the assessment is Multi-fuctional Administrative City which locates in Yeongi-gun, Chungcheongnam-do and estimated population in 2030 is 500,000. Two automatic weather monitoring stations were installed to monitor the meteorological variables for a year and upper air meteorological parameters were measured using radiosonde for 5 days with 4 hours interval in every season. The air quality of standard air pollutants were also measured for 5 days continuously in every season. The results of wind field analysis based on the site measurements and CALMET modeling showed that the valley and mountain winds were prevailed when the sypnotic wind was weak. It also showed that wind speed and directions were highly space-variable within the site basin. The variable wind characteristics implies that the Gaussian dispersion model such ISC3 and AERMOD are not appropriate and the unsteady-sate Lagrangian model such as CALPUFF is preferable. CALPUFF model was applied to assess air quality impact of new sources. The new sources were those for individual and group heating facilities as well as the traffic increases. The results showed that the estimated concentrations of CO and $SO_2$ pollutants by summing the impact concentration of new sources by the dispersion model and the ambient air concentrations by the site measurements were acceptable but those of PM-10 and $NO_2$ would violate ambient air quality standards at several locations due to high ambient air concentrations. It is recommended that the emission reductions near the site should be enforced to improve the ambient air quality.

Metal Effects of Urban Air Particulates on Cytokine Production and DNA Damage

  • Lee, Kwan-Hee;Hong, Yun-Chul
    • Toxicological Research
    • /
    • 제17권4호
    • /
    • pp.255-265
    • /
    • 2001
  • Epidemiologic studies have demonstrated an association between short-term exposure to particulate air pollutants and increased mortality. However the biological mechanism underlying these associations have not been fully established and also the chemical and physical characteristics of the pollutant particles are not well understood. The metal constituents of air pollutant particles and their bioavailability are considered to Play an important role as possible mediators of Particle-induced airway injury and inflammation. Sprague-Dawley rat alveolar macrophage cells (NR8383) were exposed to airborne and acid-leached particulate matter (PM). Titanium oxide and nickel subsulfide were used as negative and positive controls. Particle-induced reactive oxygen species formation in cells was detected using the fluorescent probe 2',7'-dichlorofluorescin diacetate. Expression of TNF-$\alpha$ and IL-6 were measured by enzyme-linked immunosorbent assay, and PM-induced DNA double-strand breaks were determined with $\lambda$DNA/Hind III marker. Metals associated with air pollutant particles mediated intracellular oxidant production in alveolar macrophages, and the cytotoxicity and proinflammatory cytokine production induced by PM were associated with oxidative stress. The oxidants produced by air pollutant particles also are likely to induce DNA double-strand breaks. Our findings in alveolar macrophage cells exposed to PM and acid-leached PM support the hypothesis that metal components in urban air pollutants and their bioavailabilities might play an Important role in the induction of the adverse health effects.

  • PDF

수동대기채취기를 이용한 잔류성유기오염물질의 농도산정 (Calculation Method for the Concentration of Persistent Organic Pollutants (POPs) Collected by Passive Air Samplers)

  • 최성득
    • 한국대기환경학회지
    • /
    • 제29권2호
    • /
    • pp.217-227
    • /
    • 2013
  • Passive air samplers (PAS) have been developed since the early 2000s and widely used for the atmospheric monitoring of persistent organic pollutants (POPs). PAS are useful especially for the investigation of source-receptor relationship of POPs because they provide higher spatial resolution data. In Korea, however, only a few research groups have conducted POPs monitoring using PAS. One of the reasons for the limited application of PAS might be due to a complicated calculation method for air concentration. In this study, therefore, we introduced the principle of polyurethane foam (PUF)-PAS, which has been most widely used in the world, and provided an example of the calculation of air concentration of polycyclic aromatic hydrocarbons (PAHs). As all data tables and equations for this calculation were provided, this method can be used for the conversion of the amount of POPs (ng) in a PUF disk to air concentration ($ng/m^3$).

자동차 대기오염물질이 고속도로 인접지역에 미치는 농도 예측에 관한 연구 (A Study of Concentration Prediction of Automobile Air Pollutant Near the Highway)

  • 박성규;김신도;김종호
    • 한국대기환경학회지
    • /
    • 제14권6호
    • /
    • pp.607-620
    • /
    • 1998
  • The influence of transportation on air quality has been elevating in urban area. Air pollutants from automobiles cause primary and secondary air pollution, and need to be tightly controlled. In this study, the effect of automobile air pollutants on highway vicinity area was evaluated by the comparison of field measurement. and target was for modeling using CALINE3, NO2 was the target for this work. It was found that the concentration predicted by CALINE3 is overestimated at low wind speed and input data of wind speed requires correction. Based on the measured data, the wind speed was modified by effective wind speed equation [Ue=U+0.24·EXP(-pxU)], and there after the accuracy of CALINE3 calculation was improved neighborhood area of highway. It was also observed that weather conditions and traffic volume affect the concentration of air pollution. Finally, the NO2 effect of automobile air pollutants on the vicinity area of highway proved to be up to 400∼600m from the highway.

  • PDF