• Title/Summary/Keyword: Universal Value

Search Result 456, Processing Time 0.031 seconds

A Study on Fluid Intake and Output Measurements (수분 섭취 및 배설량의 측정방법에 관한 연구)

  • Choi, Smi;Yang, Young-Hee;Jung, Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.88-98
    • /
    • 1995
  • The Fluid and electrolytes balance in the body is of critical importance in maintaining good health. When the fluid and electrolyte imbalance is present, patients are in great danger. They must be assessed immediately by a nurse so that appropriate treatment can be started as soon as possible. Patients' fluid intake and output records contain highly important information for the diagnosis and treatment of fluid imbalance, but, these records are often inaccurate and the method of recording the fluid intake is not universal for every hospital. Be-cause they are few quantitative measurements of a patient's hydration, the need to improve the accuracy of fluid intake records is very important. However, very few studies have been done to investigate the accuracy of measurements of patients' fluid intake and output. The purpose of this study was to investigate the methods used for calculation of fluid intake which is most similar to fluid output in normal adults and hospitalized patients. This study focused on three different calculation methods for fluid intake and compared these to fluid output and developed suggestions as to the ideal way to record fluid in-take. Data for 43 hospitalized patients and 37 normal adults were analyzed. The findings of this study are as follows ; 1) In normal adults, the daily intake of water which enteres by the oral route was 2415m1 (the first method of calculation). The daily intake of water in the form of pure water or some other beverage was 1365m1 (the third method of calculation) The daily intake of water including fresh fruits and vegetables, rice, porridges, and Me m which have water content more than 80% were 2186m1 (the second method of calculation). 2) The urine output of the normal adults was 1350m1. This apprroximates the amount of fluid an adult takes in the form of pure water. 3) In patient group, the total intake of water was 2550m1 (the first method of calculation). The in-take of water in the form of pure water or as some other beverage and IV fluid was 1661m1 (the third method of calculation). The daily in-take of water including foods which have high water content was 2356m1 (the second method of calculation). 4) The urine output of the patient's group was 1728m1. This approximates the amount of fluid an adult takes in the form of pure water. 5) Investigation of the method of calculation of the patient fluid intake showed that among the 31 hospitals studied, only eight use the third method of calculation which reflects the most close value to urine output. From the results obtained in this study, it was indicated that the amount of fluid taken in the form of pure water reflects the most close value to urine output. Therefore, it can be suggested that the third method of calculation which includes water in-take only in the form of pure water or beverage should be used as patients' fluid intake record.

  • PDF

Deep Learning Framework for Watermark-Adaptive and Resolution-Adaptive Image Watermarking (워터마크 및 해상도 적응적인 영상 워터마킹을 위한 딥 러닝 프레임워크)

  • Lee, Jae-Eun;Seo, Young-Ho;Kim, Dong-Wook
    • Journal of Broadcast Engineering
    • /
    • v.25 no.2
    • /
    • pp.166-175
    • /
    • 2020
  • Recently, application fields for processing and using digital image contents in various forms and types are rapidly increasing. Since image content is high value-added content, the intellectual property rights of this content must be protected in order to activate the production and use of the digital image content. In this paper, we propose a deep learning based watermark embedding and extraction network. The proposed method is to maximize the robustness of the watermark against malicious/non-malicious attacks while preserving the invisibility of the host image. This network consists of a preprocessing network that changes the watermark to have the same resolution as the host image, a watermark embedding network that embeds watermark data while maintaining the resolution of the host image by three-dimensionally concatenating the changed host image and the watermark information, and a watermark extraction network that reduces the resolution and extracts watermarks. This network verifies the invisibility and robustness of the proposed method by experimenting with various pixel value change attacks and geometric attacks against various watermark data and host images with various resolutions, and shows that this method is universal and practical.

A STUDY OF THE EFFECT OF LOW INTENSITY INITIAL LIGHT CURING ON THE BOND STRENGTH OF RESIN RESTORATION (초기 저광도 광중합이 레진 수복물의 결합강도에 미치는 영향에 관한 연구)

  • Han, Mi-Ran;Kwon, Soon-Won;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.45-53
    • /
    • 2001
  • Recently some studies have shown that low light intensity followed by final cure at high light intensity may result in a smaller marginal gap and may be no negative effect on material properties. The purpose of this study was to evaluate the influence of the initial cure with low intensity on the shear bond strength of dentin and the microhardness of composite resin. Twenty intact bovine teeth were prepared for shear bond strength test and each tooth sectioned to three specimens. The specimens were randomly divided into three groups according to the light intensity and curing time as follows; Group I. $450mmW/cm^2$ 40sec Group II. $300mmW/cm^2$ 20sec and $600mmW/cm^2$ 20sec Gropu III. $250mmW/cm^2$ 20sec and $450mmW/cm^2$ 20sec. Samples of each group were restored with light-cured composite resin after dentin bonding and then the shear bond strength of each specimen were measured using universal testing machine. Ten resin specimens per group were prepared. After 24 hours, the Vickers microhardness value was measured at the top and bottom surfaces. The result are as follows; 1. Mean value of low initial intensity groups(II, III) were higher than the control group(I) in shear bond strength, but no significant difference could be found. 2. No significant difference could be found between three groups in microhardness.

  • PDF

A Tapping the usefulness of Whole Blood Interferon-${\gamma}$ Assay for Diagnosing Tuberculosis Infection in Children (소아 결핵 감염 진단에 있어서 결핵 특이항원 자극 Interferon-${\gamma}$ 분비능 측정의 진단적 유용성)

  • Soon, Eu-Gene;Lim, Baek-Keun;Kim, Hwang-Min;NamGoong, Mee-Kyung;Cha, Byung-Ho;Uh, Young;Chun, Jin-Kyong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.5
    • /
    • pp.280-285
    • /
    • 2010
  • Background: $QuantiFERON^{(R)}$-TB Gold In Tube (QFT-G IT) has been used for diagnosing latent tuberculosis infection and active tuberculosis (TB) since 2007. However, there has not been enough data on QFT-G IT for universal use in children. In this study, we evaluated the clinical usefulness of the QFT-G IT in pediatric practice. Methods: We retrospectively reviewed the clinical records of 70 patients younger than 18 years of age who had taken QFT-G IT and had a tuberculin skin test (TST) between July 2007 and July 2009 at Wonju Christian Hospital. The subjects were divided into two groups, asymptomatic TB exposure group and disease group. Four patients who were taking immunosuppressants during the study period were excluded. Results: A total of 66 immunocompetent children were included in this study. Among 27 asymptomatic children who had contact histories of TB, 6 (22.2%) were found to be positive by QFT-G IT. Eleven (40.7%) and 5 (18.5%) children were found to be positive by TST with cutoff values of ${\geq}5mm$ and ${\geq}10mm$, respectively. Agreement was fair to good between QFT-G IT and TST (${\kappa}=0.59$: cutoff value ${\geq}5mm$, ${\kappa}=0.7$: cutoff value ${\geq}10mm$). In disease group, 14 patients (35.9%) were diagnosed with active tuberculosis, 8/14 (57.1%) were positive on TST and 9/14 (64.3%) on QFT-G IT. The positive rate of acid-fast bacilli smear, TB-polymerase chain reaction, and culture for tuberculosis was 11% (1/9), 27.3% (3/11) and 33.3% (3/9), respectively. Conclusion: Our data support that the QFT-G IT can be used as an additional diagnostic tool for latent and active tuberculosis infection in children.

In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality (연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구)

  • Kim, Duck-Rae;Kim, Myung-Joo;Kwon, Ho-Beom;Lee, Seok-Hyung;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.391-401
    • /
    • 2009
  • The successful outcome of dental implants is mainly the result of intial implant stability following placement. The aim of this study was to investigate the effect of a self-tapping blades and implant design on initial stability of two tapered implant systems in poor bone quality. The two different implant systems included one with self-tapping blades and one without self-tapping blades. D4 bone model using Solid Rigid Polyurethane Form was used to simulate poor bone densities. The insertion torque during implant placement was recorded. Resonance frequency Analysis (RFA), measured as the implant stability quotient (ISQ), was assessed immediately after insertion. Finally, the implant-bone specimen was transferred to an Universal Testing Machine to measure the axial pull-out force. Insertion torque values and maximum pull-out torque value of the non self-tapping implants were significantly higher than those in the self-tapping group (P = 0.008). No statistically differences were noted between the two implant designs in RFA. Within the each implant system, no correlation among insertion torque, maximum pull-out torque and RFA value could be determined. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical initial stability. In conclusion, implants without self-tapping blades have higher initial stability than implants with self-tapping blades in poor bone quality.

Development plans of FTA Experts in Product Areas (상품분야 FTA 전문 인력 양성 방안)

  • LIM, Mok-Sam;CHOI, Mi-Soo
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.70
    • /
    • pp.159-179
    • /
    • 2016
  • Companies do not be resolved by the FTA services of external aid should be operational by assigning dedicated personnel inside the company. FTA is a choice, not an essential trade agreement requirements. If the exporter contracts to provide a certificate of origin in trade agreements, it shall issue a certificate of origin of goods originating management is performed. When considering the future trend of spreading wide FTA, it should be extended to one year to take advantage of the FTA Certificate of Origin environments utilizing a comprehensive environment for regional countries that require proof of origin between certain countries, such as current. FTA utilization of the future is to utilize the GVC(Global Value Chain) efficiently. In other words, the expansion of the consumer market and take advantage of an efficient production base across borders. These environmental changes are needed development of the FTA utilization promotion and FTA experts. The experts studying how to procure raw materials or intermediate goods exports in a variety of regional foreign countries, to meet the rules of origin is required for a successful FTA utilization. One of the objectives of Origin managers are qualified experts in the country of origin can take advantage of the FTA plan. Therefore, managers of origin shall collect their ability to expand the understanding and information about the industry as an international business perspective beyond the Certificate of Origin. In addition, it should be in their best learning expertise for the introduction and development of country of origin control system in an effort to effectively perform its international FTA utilization. Once the FTA is more widespread in the future and build a common origin information it must not be disconnected until the export enterprises from terminal manufacturers systematically. Therefore origin management is preferred by expanding the knowledge base of teaching and learning in the common sense to the universal subject of specialization from professional schools to promote the relevant departments so that they can be opened in a college or university. An FTA hub linking East and West, also need the confidence that in order to become a center of Glabal Supply Chain Using an FTA Certificate of Origin and stable environment for importers to import products from the country offers. Certificate of Origin and all of them thoroughly exporters and companies related to the administration of origin and should create an atmosphere that can effectively respond to the origin verification. Korea shall endeavor to elicit a geopolitical value (FTA Hub), as well as securing a competitive advantage in the global industry leverage, trading at a reasonable price competitive products thereby enhancing production and economic growth through the FTA.

  • PDF

The Effect of Cognitive Rehabilitation Program Using Virtual Reality (VR) Contents on Cognitive function, Depression, Upper Extremity Function and Activities of Daily Living in the Elderly (가상현실(Virtual Reality) 콘텐츠를 활용한 인지재활프로그램이 노인의 인지기능, 우울감, 상지기능 및 일상생활능력에 미치는 영향)

  • Kim, Young-June;Park, Jin-Hong;Cho, Young-Suk;Kim, Keum-Sook
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.203-212
    • /
    • 2020
  • The purpose of this study was to investigate the effects of cognitive rehabilitation programs using Virtual Reality(VR) content on the daily living abilities such as cognitive abilities, depression, and upper extremity functions of the elderly. The study group analyzed the effectiveness by separating the experimental group, which is the virtual reality cognitive rehabilitation application group, and the control group, the universal cognitive stimulation program application group. As a result of the study, the MMSE-K score improved by 13.0% in the experimental group and 2.3% in the control group. The improvement in each area of the experimental group was found to be 3.1% MBI, 7.1% MFT(Rt.), 3.5% MFT(Lt.), and 25.4% K-GDS. As a result of comparing the pre-post score change between each group, there was a significant difference between groups in daily living ability (p<.001) and MFT(Rt.)(p<.01). In addition, as a result of comparing the changes in absolute alpha waves to confirm the degree of depression through brain waves, there was no statistically significant difference. However, in the experimental group, it was confirmed that the average value increased to a positive value. This study is an experiment to verify the effectiveness of the cognitive rehabilitation program using virtual reality contents, and suggests a new intervention method to maintain and improve the daily life ability, cognitive function, depression and upper extremity function of the elderly.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.

THE EFFECT OF ACID ETCHING ON GLASS IONOMER CEMENT SURFACES (Glass ionomer cement 표면의 산부식 효과에 관한 연구)

  • Han, Seung-Weon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.1-26
    • /
    • 1993
  • The purpose of this study was to investigate the effect of acid etching on the surface appearance and fracture toughness of five glass ionomer cements. Five kinds of commercially available glass ionomer cements including chemical curing filling type, chemical curing lining type, chemical curing metal reinforced type, light curing tilling type and light curing lining type were used for this study. The specimens for SEM study were fabricated by treating each glass ionomer cement with either visible light curing or self curing after being inserted into a rubber mold (diameter 4mm, depth 1mm). Some of the specimens were etched with 37% phosphoric acid for 0, 15, 30, 60, go seconds, at 5 minutes, 1 hour and 1 day after mixing of powder and liquid. Unetched ones comprised the control group and the others were the experimental groups. The surface texture was examined by using scanning electron microscope at 20 kV. (S-2300, Hitachi Co., Japan). The specimens for fracture toughness were fabricated by curing of each glass ionomer cement previously inserted into a metal mold for the single edge notch specimen according to the ASTME399. They were subjected to a three-point bend test after etching for 0, 30, 60, and 90 seconds at 5 minutes-, 1 hour-and 1 day-lapse after the fabrication of the specimens. The plane strain fracture toughness ($K_{IC}$) was determined by three-point bend test which was conducted with cross-head speed of 0.5 mm/min using Instron universal testing machine (Model No. 1122) following seven days storage of the etched specimens under $37^{\circ}C$, 100% humidity condition. Following conclusions were drawn. 1. In unetched control group, crack was present, but the surface was generally smooth. 2. Deterioration of the surface appearance such as serious dissolving of gel matrix and loss of glass particles occured as the etching time was increased beyond 15 s following Immediate etching of chemical curing type of glass ionomer cements. 3. Etching after 1 h, and 1 d reduced surface damage, 15 s, and 30s etch gave rough surface appearance without loss of glass particle of chemical curing type of glass ionomer cements. 4. Light curing type glass ionomer cement was etched by acid, but there was no difference in surface appearances according to various waiting periods. 5. It was found that the value of plane stram fracture toughness of glass ionomer cements was highest in the light curing filling type as $1.79\;MNm^{-1.5}$ followed by the light curing lining type, chemical curing metal reinforced type, chemical curing filling type and chemical curing lining type. 6. The value of plane stram fracture toughness of the chemical curing lining type glass ionomer cement etched after 5 minutes was lower than those of the cement etched after 1 hour or day or unetched (P < 0.05). 7. Light curing glass ionomer cement showed Irregular fractured surface and chemical curing cement showed smooth fractured surface.

  • PDF

From Volunteering to Collaboration, and from Transmission to Learning: Interpreting Science Teachers' Learning Experiences in Interculturalism through International Development Cooperation (봉사에서 협력으로, 전달에서 학습으로 -과학교사의 국제개발협력사업 참여를 통한 상호문화주의 학습 경험 해석-)

  • Hwang, Seyoung
    • Journal of The Korean Association For Science Education
    • /
    • v.41 no.5
    • /
    • pp.429-440
    • /
    • 2021
  • In this article, we explored the value of interculturalism in developing the discourses of international cooperation in science education. By doing so, we interviewed four teachers who had an experience in teaching science in developing countries, and analyzed their experiences and perceptions in the lens of interculturalism and dialogue. Our analysis of teacher narratives shows the transition in the teachers' perspectives from volunteering and transmission to collaboration and learning. The transition from volunteering to collaboration occurred as the teachers learned how to meet 'the others' as themselves being strangers in the foreign context. Through intervening and colliding, teachers were able to reposition their identities as teachers. Furthermore, their science teaching practices show how the teachers tried to negotiate between the universal or idealistic value of science education and the heterogeneities formed by the country's cultural and specific situation of science education. Through these experiences, the teachers began to understand the importance of the culturally specific 'need' for science education. In conclusion, we proposed a discourse of science education collaboration based on interculturalism in terms of the diversity and complexity of science education practices in developing countries, teacher professionalism, culturally relevant pedagogy and sustainable policy.