• Title/Summary/Keyword: Unit-care Facility

Search Result 48, Processing Time 0.02 seconds

A Study on the User Needs for Renovation of Race Track Type of Nursing Units in K University Hospital (K대학병원 병동부 이중복도형의 개선을 위한 사용자 요구 조사연구)

  • Kim, Youngaee;Yim, Ohyon;Kim, Jungshin;Yi, Jongse;Ahn, Uijong
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.3
    • /
    • pp.21-28
    • /
    • 2013
  • Purpose: General hospital in korea is getting large-scaled, specialized and upgraded. So, nursing unit of race track type has been advanced along with a spatial organization, building equipment and environmental approach. This study is to search the guidelines for renovation of nursing unit with race track type in the case of K university hospital in Daejeon. Methods: 9 cases of recently opened general hospital has been analyzed for spatial and environmental design solution. Questionnaires and interviews about user needs of nursing staff, patient and visitors, have been conducted for a nursing care system and facility of nursing units in K university hospital. Results: The user needs are represented as followings. Center core public zone in each floor plan and center core nursing station and supporting areas in nursing unit are good for an adjacency and separation of spatial organization. Toilet of group patient room is necessary to equip for easy, safe and infective aspects, and so toilet install will decrease the patient number and increase the nursing care service. Hall type of station front is good for visibility and observation. It is appropriate to renovate into south facing group patient room for privacy, enough space for nursing care facility and supporting area, enough width of door to move portable medical equipment, room for medical doctor and practical student, noise absorbing of day room. Implications: Upgrading the nursing care service and facility equipment is necessary to reflect the user needs and cooperate with hospital management.

A Study on the Architectural Design Guideline for Intensive Care Unit - Focused on Cases of The US, The UK and Australia (중환자부 시설기준 수립을 위한 가이드라인 조사·분석연구 - 미국, 영국, 호주 사례를 중심으로)

  • Yun, Woo Young;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.4
    • /
    • pp.17-25
    • /
    • 2015
  • Purpose: At the moment, There is a facility standard for intensive care units on the Korea medical services Act. However, the contents of regulation are so limited and difficult to apply. Therefore, it is necessary to draw up the guideline to complement the regulation for efficient operation of intensive care units. This study aims to suggest basic data for guideline of intensive care units. Methods: 2 Methods have been used in this paper. 1) Comparative analysis between the national regulation of Korea with the design standard of the United States America, the United Kingdom and Australia. 2) A literature survey about operation method for intensive care unit, focused on materials published in intensive care medicine society of each country. Results: In comparison with guideline of abroad cases, additional supplement are required, with regard to item such as operation environment, size, nursing manpower ratio, bed space area, space program of intensive care units for healing environment. Implications: This study is a basic research for guideline of intensive care unit, and need to be followed by further study using various perspectives and methods.

Spatial Configuration Analysis of the Elderly Care Facilities Based on Visibility - Visibility Analysis and Agent-Based Simulation Using Space Syntax - (가시성에 기반한 노인요양시설의 공간계획에 관한 분석 - 공간구문론을 활용한 가시성 분석과 에이전트 시뮬레이션을 중심으로 -)

  • Lee, Jisun;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.14-23
    • /
    • 2018
  • The spatial planning of the elderly care facility plans is analyzed using space syntax in terms of encouraging the social interaction of the residents in this study. First, through the visibility graph analysis, openness and accessibility of space is analysed. Second, the walking behavior of residents through agent analysis model is simulated. Third, the space planning methods for the elderly care facilities are proposed based on the results. The results are as follows. According to the visibility graph analysis, the main corridor has high visual openness and high accessibility. The visual openness and accessibility of the unit living room, where social interaction among residents is possible in each unit, is low. Space planning is needed to increase direct protection and observation of employees to the unit living room. The location of the nurse station that manages the entire floor needs to be located where the openness and accessibility is most high. The nursing station should have a high degree of connectivity to the entire space, so that any accidents can be managed and contact is accessible. Through the agent simulation the flow from the center to each unit space is highest in the corridor space and the inflow to the private rooms and the living room are similar. Therefore, it is necessary to plan the accessibility of the unit living room more for the natural inflow of residents.

Analysis on Spatial Pattern of Child Care Environment in Rural Area using Accessibility (접근성을 이용한 농촌지역 유아보육환경의 공간적 특성 분석)

  • Jeon, Jeongbae;Park, Meejeong;Choi, Jinah;Lim, Changsu;Kim, Eunja
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • This study is to evaluate the per capita accessibility to child care facilities using road map in rural village unit considering the supply and demand of child care facilities in municipal (Si-Gun) units. Using these estimated accessibility, the most accessible regions to child care facilities was identifies using Moran's index. Assuming establish a new child care facility in the most accessible region, the sensitivity of child care environment was analyzed. The number of regions are 71 si-gun-gu where supply of child care facilities is insufficient. The average accessibility per capita is 1.09 km to child care facilities and the average accessibility in Myeon unit is approximately 2.2 times higher than accessibility in Eup unit (Eup unit 0.54 km, Myeon unit 1.21 km). Approach tendency from village to child care facilities has positive relationship as 0.451 global Moran's index. The high-high (H-H) accessibility regions are wide as Gangwon-do, Gyeongsangbuk-do, Gyeongsangnam-do, Jeollanam-do and Chungcheongbuk-do. Assumed to be established the new child care facilities in Yangyang-gun (Ganwon-do), accessibility changes of child care environment are up to 2.7 times greater and the recipient population is 77% of Yangyang-gun.

A Case Study on the Remodeling Plan of Closed School as Elderly Facility And Developing Composition Type -Implication of Okchun Dongyi Middle School- (폐교를 활용한 노인요양시설 리모델링 사례와 평면유형 개발 -옥천군 동이면 동이중학교를 대상으로-)

  • Nam, Yun-Cheol
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.4
    • /
    • pp.99-106
    • /
    • 2011
  • Since 1982, schools have been closed down by urbanization in rural areas. 3,386 schools had been closed down by March 2010. The average 300 schools was closed down every year. 55.7% closed schools were sold, 14.5% closed schools were rented. 6.3% closed schools have been utilized as education facilities. First, the closed school should be utilized as education facilities. And it should be utilized as public facilities as well as welfare facilities for local residents. This paper presents a case of the welfare facility remodeled using Don-Yi middle school in Okcheon-Gun, Chungcheongbuk-Do and propose the unit care composition. The main contents is composed of posts, beams floors, stairs. Masonry infill walls and windows ware improved. Corridors were placed. A classroom were divided into 2 rooms with the Korean traditional heating system(on-dol) for four. Other conveniences were designed for a cafeteria, recreation, a restroom as space required. It is effective to utilize the closed school that has magnificent views and orientation, space construction. The Unit-care system is proposed by 4 types developments.

Comparative Review of Design Guidelines of Hospice Facilities for Establishing Standards (호스피스 시설기준 수립을 위한 디자인 가이드라인 비교연구)

  • Lee, Sukyung;Yoon, Hungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • Purpose: This study aims to analyze design guidelines for hospice facilities in the US, UK, and Canada focused on design considerations and space requirements, and utilizes them as baseline data for establishing standards for Korean hospice facilities. Methods: Comparative review was carried out to investigate hospice care models, design consideration, and room sizes and requirements for design guideline of hospice facilities in United States, UK and Canada identified on electronic database and review articles, and to examine major characteristics and tendencies of hospice facilities. Results: The hospice care models characteristics in design guidelines is generally largely divided into hospital-based hospice facility, Nursing home-based hospice facility, and daycare hospice. The design considerations in hospice facilities focused on medical efficiency, flexibility, barrier-free environment, person-centered care, and stability. There is also a need for single resident room, rooms for the patient's family, and isolation room for infection control. Implications: it is recommended to establish standards for the installation and operation of required and recommended rooms and considerations when establishing the standards of hospice facilities in Korea. This Study is limited to a simple comparative analysis of the framework of guideline.

A Clinical Study for Promoting Quality Nusing Care in a University Hospital (질적 간호제공을 위한 간호단위 시범 운영 효과에 관한 임상적 연구)

  • Lee, A.J.;Kim, S.H.;Seong, Y.H.;Yoo, S.A.;Kwon, I.G.;Jeong, Y.I.;Nam, H.K.;Kwon, E.J.
    • The Korean Nurse
    • /
    • v.32 no.5
    • /
    • pp.66-77
    • /
    • 1994
  • The purpose of this study was to develop a new nursing unit which can meet changing health care needs, enhance patients' satisfaction and nurses' job satisfaction, and finally guarantee quality nursing care with present manpower. For this, one medical unit was selected as a unit for quality care. And one medical unit which is similar in staffing and patients' characteristics was selected as a control unit. To assess present problems and identify the remedies to the problems a hospital-wide survey and a workshop were performed. According to the survey results, educational programs and improvement of the facilities and equipment supply system, managereal support for interdepartmental cooperation and intensification of bed-side nursing care were adopted as main principles for operating model unit, This model unit was operated for 3 months from Sep. 1, 1992 to Nov. 30, 1992. To evaluate the effectiveness of the model unit, derect/indirect nursing care hours, patients' satisfaction to nursing care, nurses' job satisfaction, and quality care index were measured. Direct/indirect nursing care hours were compared with that of the control unit, and patients' and nurses' satisfaction and quality care index were measured before and after operating model unit and compared with each other. The results of the study were as follows; 1. In the model unit mean direct nursing care hours per cach shift was 146.88 minutes and indirect nursing care hours was 354.72 minutes. The ratio of the direct nursing care hour to indirect nursing hour was 29.6 ; 70.4 and that of the control unit was 26.9 : 73.1. Direct nursing care hour in model unit was longer than that of the control unit. But, the difference was not significant. In subcategories of direct nursing care, the time spent in mobility and exercise, conservation of body temperature, hygiene, and communication and health education were longer than that of the con" trol unit. 2. Indirect nursing care hour in model unit was shorter than that of the control unit. But, the difference was not significant. In subcategories of indirect nursing care, the time spent in drug management and ward arrangement was shorter than that of the control unit. 3. Patients' satisfaction to nursing care was increased significantly after operating the model unit (T=-3.48, P=-0.002) and satisfaction to subcategories of physical comfort measure, psychological cate, and unit management components were significantly higher than before. 4. In the model unit, nurses' total job satisfaction was increased significantly after operating the model unit(Z=2.1004, P=.0357) and satisfaction to subcategory of satisfaction to administration was significantly higher than before (Z=-2.0732, P=.0382). 5. After operating the model unit, quality care index was increased from 89 to 93. With this results, it can be summarized that all the measures tried for quality care, such as educational programs, managereal support for interdepartmental cooperation, and improvement of the equipment and facility provision resulted in partial increase in direct nursing care hours, nurses satisfaction to their job and patients' satisfaction to nursing care. In can be postulated that managereal support and motivation without proper staff supplementation is not enough for increasing direct nursing care hours. And for the enhancement of the level in clinical nursing, and staff supplement must be considered sincerely and the measures for reducing indirect nursing care hours, such as computerization of nursing care activities, improvement of facilities and equipment and facilities supply system, must be instituted in addition.

  • PDF

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

Health Supportive Design in Elderly Care Homes: Swedish Examples and their Implication to Korean Counterparts

  • Lee, Sookyoung;Dilani, Alan;Morelli, Agneta;Byun, Hearyung
    • Architectural research
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2007
  • The objective of this research study was twofold; 1) to explore and identify health supportive design factors in Swedish elderly care homes and 2) to understand their usefulness and suggest implication in Korean elderly care settings. A descriptive and explorative method was applied using a combination of field studies and semi-structured interviews. Three study trips were carried out during Sept. $14^{th}$ and Oct. $12^{th}$ 2005; two facilities situated in Stockholm suburbs and one in the south of Sweden. According to this research, the valuable factors to support health and well-being for the elderly are as follows; 1) Community integration: These elderly care homes are generally places close to a residential area center or a city center. Services are often shared between residents and community members at large, consequently there is a flow of "visitors" of all ages connecting with the facility on a daily basis. 2) Homelike environment: A noteworthy aspect of Swedish elderly care homes is keeping the facility appearance as homelike as possible. The associations with home may be explored through the appearance and configuration of both the exterior and interior of the building. These homes seemed to be designed with a conscious aim to create a homelike setting. 3) Small scale approach: Clustering of resident rooms is one method through which the small scale approach can be achieved in larger facilities. With unit clusters, the facility can foster opportunities for social interactions among resident. 4) Accessibility to garden and nature: The courtyard is a well developed concept in planning elderly care homes in Sweden. They are generally safe and easily accessible to the residents. Studying Swedish models may provide practical knowledge of how the physical setting may improve resident's health in Korean elderly care homes.

Testing The Healing Environment Conditions for Nurses with two Independent Variables: Visibility Enhancement along with Shortening the Walking Distance of the Nurses to Patient - Focused on LogWare stop sequence and space syntax for U-Shape, L- Shape and I-Shape NS-

  • Shaikh, Javaria Manzoor;Park, Jae Seung
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.19-26
    • /
    • 2015
  • Purpose: Maximizing human comfort in design of medical environments depends immensely on specialized architects particularly critical care design; the study proposes Evidence-Based Design as an apparent analog to Evidence-Based Medicine. Healthcare facility designs are substantially based on the findings of study in an effort to design environments that augment care by improving patient safety and being therapeutic. On SPSS (Statistical Package for Social Science) t-test is applied to simulate two independent variables of PDR (Pre Design-Research) and POE (Post- Occupancy Evaluation). PDR is conducted on relatively new hospital Hallym University Dongtan Sacred Heart Hospital to analyse visibility from researchers' point of view, here the ICU is arranged in I-Shape. POE is applied on Dongguk University Ilsan Hospital to simulate walking on LogWare where two NS are designed based on L- Shape and Seoul St. Mary's Hospital, The Catholic University of Korea where five NS are functional for ICU Intensive Care Unit, Surgical Intensive Care Unit (SICU), Medical Intensive Care Unit (MICU), Critical Care Unit (CCU), Korean Oriental Medical Care Unit which are mostly arranged in U-Shape, and walking pattern is recognized to be in a zigzag path. Method: T-Test is applied on two dependent communication variables: walkability and visibility, with confidence interval of 95%. This study systematically analyses the Nurse Station (NS) typo-morphology, and simulates nurse horizontal circulation, by computing round route visits to patient's bed, then estimating minimum round route on LogWare stop sequence software. The visual connectivity is measured on depth map graphs. Hence the aim is to reduce staff stress and fatigue for better patients care by minimizing staff horizontal travel time and to facilitate nurse walk path and support space distribution by increasing effectiveness in delivering care. Result: Applying visibility graph and isovist field on space syntax on I- Shape, L- Shape and U- Shape ICU (SICU, MICU and CCU) configuration, I-shape facilitated 20% more patients in linear view as they stir to rise from their beds from nurse station compared to U-shape. In conclusion, it was proved that U-Shape supply minimum walking and maximum visibility; and L shape provides just visibility as the nurse is at pivot. I shape provides panoramic view from the Nurse Station but very rigorous walking.