• Title/Summary/Keyword: Unit method

Search Result 7,032, Processing Time 0.037 seconds

Natural modes of modularized floating structures (모듈형 부유구조물의 고유모드 고찰)

  • Kim, Byoung-Wan;Hong, Sa-Young;Kyoung, Jo-Hyun;Cho, Seok-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1173-1176
    • /
    • 2007
  • This paper investigates the natural modes and static reponses of modularized floating structure. As an example structure, a floating parking place$(120m{\times}60m)$ is considered. In the evaluation of natural modes and static responses, numerical equations are formulated by FEM(Finite Element Method) and the natural modes are solved by subspace iteration method. By comparing responses of structures of various sizes of module unit, the effect of unit size is also investigated.

  • PDF

An Improved Dynamic Programming Approach to Economic Power Dispatch with Generator Constraints and Transmission Losses

  • Balamurugan, R.;Subramanian, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.320-330
    • /
    • 2008
  • This paper presents an improved dynamic programming (IDP) approach to solve the economic power dispatch problem including transmission losses in power systems. A detailed mathematical derivation of recursive dynamic programming approach for the economic power dispatch problem with transmission losses is presented. The transmission losses are augmented with the objective function using price factor. The generalized expression for optimal scheduling of thermal generating units derived in this article can be implemented for the solution of the economic power dispatch problem of a large-scale system. Six-unit, fifteen-unit, and forty-unit sample systems with non-linear characteristics of the generator, such as ramp-rate limits and prohibited operating zones are considered to illustrate the effectiveness of the proposed method. The proposed method results have been compared with the results of genetic algorithm and particle swarm optimization methods reported in the literature. Test results show that the proposed IDP approach can obtain a higher quality solution with better performance.

A Study on the True RMS Measurement of Electrical Unit for Performance Test (전기수술기 성능시험용 True RMS 측정에 관한 연구)

  • Ko, Han-Woo;Bae, Moon-Seob;Choi, Duck-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.309-314
    • /
    • 1991
  • This paper describes the results of study on the measurement method of TRMS (true root mean square value) In electrosurgical unit. We used three type (direct computing type, indirect computing type, thermal converting type) in the measurement of TRMS. Three types of measurement method were compared with respect to power level, frequencey and crest factor in addition to environmental temperature. In three of them, the thermal converting type was the best for th electrosurgical unit analyzer

  • PDF

Work Measurement in Robot Ergonomics (Robot Ergonomics의 일환으로서 로봇 작업측정에 관한 연구)

  • 권규식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.48
    • /
    • pp.201-211
    • /
    • 1998
  • The fundamental object of work measurement is to precisely establish the time standards, which are the indices of labor productivity. This study discussed the development of robot work measurement method that could establish the time standard effectively. In manufacturing industries the various robot tasks are generally classified and standardized by the unit motions. The Robot Modularization of the Unit Motion (ROMUM) was realized by the module of two steps GET and PUT unit motions. This method reduced time and effort of analysis, and could be done with ease. Therefore, ROMUM will increase the convenience of use for the unskilled worker and decrease the time required, cost and errors. And, it will contribute to reduce the unnecessary motion by robot motion analysis.

  • PDF

Optimal Scheduling in Power-Generation Systems with Thermal and Pumped-Storage Hydroelectric Units

  • Kim, Sehun;Rhee, Minho
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.15 no.1
    • /
    • pp.99-115
    • /
    • 1990
  • This paper is concerned with the unit commitment problem in an electric power system with both thermal and pumped-storage hydroelectric units. This is a mixed integer programming problem and the Lagrangean relaxation method is used. We show that the relaxed problem decomposes into two kinds of subproblems : a shortest-path problem for each thermal unit and a minimum cost flow problem for each pumped-storage hydroelectric unit. A method of obtaining an incumbenet solution from the solution of a relaxed problem is presented. The Lagrangean multipliers are updated using both subgradient and incremental cost. The algorithm is applied to a real Korean power generation system and its computational results are reported and compaired with other works.

  • PDF

Method of SSO Noise Reduction on FPGA of Digital Optical Units in Optical Communication

  • Kim, Jae Wan;Eom, Doo Seop
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.97-101
    • /
    • 2013
  • There is a growing need for optical communication systems that convert large volumes of data to optical signals and that accommodate and transmit the signals across long distances. Digital optical communication consists of a master unit (MU) and a slave unit (SU). The MU transmits data to SU using digital optical signals. However, digital optical units that are commercially available or are under development transmit data using two's complement representation. At low input levels, a large number of SSOs (simultaneous switching outputs) are required because of the high rate of bit switching in two's complement, which thereby increases the power noise. This problem reduces the overall system capability because a DSP (digital signal processor) chip (FPGA, CPLD, etc.) cannot be used efficiently and power noise increases. This paper proposes a change from two's complement to a more efficient method that produces less SSO noise and can be applied to existing digital optical units.

Identification of beam crack using the dynamic response of a moving spring-mass unit

  • An, Ning;Xia, He;Zhan, Jiawang
    • Interaction and multiscale mechanics
    • /
    • v.3 no.4
    • /
    • pp.321-331
    • /
    • 2010
  • A new technique is proposed for bridge structural damage detection based on spatial wavelet analysis of the time history obtained from vehicle body moving over the bridge, which is different from traditional detection techniques based on the bridge response. A simply-supported Bernoulli-Euler beam subjected to a moving spring-mass unit is established, with the crack in the beam simulated by modeling the cracked section as a rotational spring connecting two undamaged beam segments, and the equations of motion for the system is derived. By using the transfer matrix method, the natural frequencies and mode shapes of the cracked beam are determined. The responses of the beam and the moving spring-mass unit are obtained by modal decomposition theory. The continuous wavelet transform is calculated on the displacement time histories of the sprung-mass. The case study result shows that the damage location can be accurately determined and the method is effective.

Planning and Design Guidelines for the New Lifestyles in One-person Officetels (신수요 계층의 생활에 대응할 수 있는 주거형 오피스텔의 계획 방안 연구)

  • 이지순;이현애;박지현;윤정숙
    • Journal of the Korean housing association
    • /
    • v.13 no.4
    • /
    • pp.53-60
    • /
    • 2002
  • The purpose of this study is to provide the guidelines for the planning and design of officetels, meeting the requirements of life in one-person household which is a new type in housing market. Literature survey is used as a research method. We analyzed the needs of officetel residents, by reviewing researches and by examining internet homepages and catalogs of 20 officetels sold since 2000. Case study analysis method is used as a qualitative analysis. The major findings of this study are as follows; 1) In dwelling unit space, it lacks the independence of working space and the privacy of living space. Therefore, the provision of various unit plans, such as 2-bay plan, unit with mezzanine floor or movable walls, layout of kitchen and dining area in window side, is proposed. 2) In communal space, it lacks the consideration of natural environments and the systematic maintenance. Therefore, the introduction of communal workshop and conference rooms and of various types of garden space, is proposed.

Variable apartment building planning by using combinable container house module (가변적 평면이 가능한 컨테이너 모듈형 조립식 공동주택의 건축계획)

  • Cho, Tae-heum;Chin, Kyung-Il
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.95-100
    • /
    • 2017
  • Purpose: Now a day, Most of the residential house in Korea consists of apartment buildings. However, in the case of old apartment buildings, dwelling environment condition depends on management effort by residents. But we can't rebuild or restructure only old single dwelling unit in apartment buildings. And we can't move every single dwelling unit in the apartment building. Therefore, this study suggests a prototype of combinable container dwelling module apartment. Method: The method of research is exploring the case of previously constructed containers. Based on the case, This study suggests prototypes to create a variable apartment design with dwelling container units. Based on the prototype, various combinations are proposed to produce various types of dwelling space. Finally, this study makes an example plan for the apartment by using the container unit modules. Results: This study suggests combinable container apartment building prototypes. And it may be a fundamental study of changing the apartment building concept.

A High-Security RSA Cryptoprocessor Embedded with an Efficient MAC Unit

  • Moon, Sang-Ook
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.4
    • /
    • pp.516-520
    • /
    • 2009
  • RSA crypto-processors equipped with more than 1024 bits of key space handle the entire key stream in units of blocks. The RSA processor which will be the target design in this paper defines the length of the basic word as 128 bits, and uses an 256-bits register as the accumulator. For efficient execution of 128-bit multiplication, 32b*32b multiplier was designed and adopted and the results are stored in 8 separate 128-bit registers according to the status flag. In this paper, an efficient method to execute 128-bit MAC (multiplication and accumulation) operation is proposed. The suggested method pre-analyzed the all possible cases so that the MAC unit can remove unnecessary calculations to speed up the execution. The proposed architecture prototype of the MAC unit was automatically synthesized, and successfully operated at 20MHz, which will be the operation frequency in the RSA processor.