• 제목/요약/키워드: Unit injection system

검색결과 113건 처리시간 0.032초

자동차 기관용 전자제어 연료분사 및 점화시기 제어기 개발 (Development of Electronic Control Fuel Injection and Spark Timing Controller for Automobile Engine)

  • 김태훈;민규식;양성환;장형성
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.22-35
    • /
    • 1995
  • In this paper, an electronic control unit is developed using 16bit microcomputer for automobile engine. This system incorporate AFS(Air Flow Sensor) of Hot Wire type, DIS(Direct Ignition System), ISC(Idle Speed Control) system, CAS(Cranke Angle Sensor) and other peripheral device. This system includes hardware and software to facilitate precision control of both fuel injection and ignition timing. Especially, this controller consists of position signal(180 teeth) and 4 REF signals. Present system has maximum $720^{\circ}CA$ delay. But this system has maximum $180^{\circ}CA$. Thus, this system is able to precision control both fuel injection and ignition timing.

  • PDF

전자제어의 Event 처리방법에 관한 연구 (A Study on the Event Processing for Electronic Control)

  • 이종승;이중순;정성식;하종률
    • 한국자동차공학회논문집
    • /
    • 제6권3호
    • /
    • pp.115-122
    • /
    • 1998
  • For digital engine control timings, such as ignition, are based on the crank shaft angle. Therefore, it is very important that the angle of the crank shaft can be detected with accuracy for optimal ignition timing. Sequential multi-point injection(MPI) systems that have independent injection events for each cylinder, are used to inject an accurate quantity of fuel, and to cope with varying engine status promptly. In this study the distributorless ignition timing. A crankshaft position sensor has been installed such that it generates a number of pulses per crankshaft revolution to permit accurate detection of the crank shaft angle. An event detecting algorithm has been developed, which detects the crank shaft pulses generated by the position sensor, and the software outputs the required control signals at given crank angle values. We clarified that the hardware method is the best way to increase the performance of the control system, because the event detecting duration T(1+2)max becomes zero.

  • PDF

고속 솔레노이드의 응답특성에 관한 연구 (A Study on the Response Characteristics of a High Speed Solenoid)

  • 조규학
    • 수산해양교육연구
    • /
    • 제12권2호
    • /
    • pp.142-151
    • /
    • 2000
  • The studies on the electronic control fuel injection system for a DI diesel engine have done for reducing the exhaust emission and improving fuel consumption. The electronic control fuel injection system is classified into a common rail system, a unit injector system and a high pressure injection system. The characteristics of these systems are largely depends on the operating characteristics of its solenoid that have high speed on-off operation. In order to improve these characteristics of fuel injection system, it is necessary to design the optimal shape of solenoid and select the input method of its power source. It was proposed HELENOID, COLENOID, DISOLE, and Multipole Solenoid in the studies of design for the optimal shape of solenoid. The studies on the energizing method, input method for power of solenoid were dealt with the conventional energizing method, the chopping method and the pre-energizing method. In order to find out the high response characteristics of solenoid, it is necessary to test the performance of optimally designed solenoid with a new energizing method. In this paper, the solenoid of multi-pole type with plat armature and its power control unit to control input current by the chopping method designed, and its response tests were performed according to its energizing conditions. As a result, the maximum input current for solenoid was controlled by the period of first stage exciting current and chopping duty ratio of control stage exciting current, and the fastest "on" time was able to get 0.46ms. The conditions of fastest "on" time was 0.3ms for first stage exciting current, 0.16ms for control exciting current and 75% for chopping duty ratio.

  • PDF

PC-ECU를 이용한 SI 기관의 비정상상태 정밀공연비 제어 (Precise Air-Fuel Ratio Control on Transient Conditions with the PC-ECU in SI Engine)

  • 윤수한
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.9-16
    • /
    • 2000
  • In a SI engine, three-way catalyst converter has the best efficiency when A/F ratio is near the stoichiometry. The feedback control using oxygen sensors in the commercial engine has limits caused by the system delays. So it is necessary to control fuel quantity in accordance with intake air amount in order to reduce exhaust emission and improve the specific fuel consumption. Precise A/F ratio control requires measurement of air amount with respect to the cylinder and injection fuel according to the air amount In this paper, we applied nonlinear fuel injection model and developed the algorithm of A/F ratio control. This algorithm includes the methods of measurement of transient air mass flowing into each cylinder, of calculation of injection pulse width for measured air mass, and the method of feedback and engine control by using lambda sensor. Also we developed control program for IBM-PC by using C++ Builder, and tested it in the commercial engine.

  • PDF

Effects of Central GABA and Glutamate on Blood Pressure and Single Unit Spikes in the RVLM of Rats

  • Park, Jae-Sik;Lee, Zee-Ihn;Jang, Jae-Hee;Ahn, Dong-Kuk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권3호
    • /
    • pp.149-154
    • /
    • 2002
  • The blood pressure (BP) is regulated by the nervous system and humoral factors, such as renin- angiotensin system, vasopressin and others. In the present study, we examined the central effects of glutamate and GABA on the cardiovascular regulation by injection of these substances into the lateral ventricle and also investigated the relationship between these central effects and the action of angiotensin II (Ang). Male Sprague Dawley rats, $350{\sim}400$ g, were anesthetized with urethane and instrumented with an arterial catheter for direct measurement of BP and heart rate (HR), and an guide cannula in the lateral ventricle for drug injection. A glass microelectode was inserted into the rostral ventrolateral medulla (RVLM) for recording single unit spikes. Barosensitive neurons were identified by changes of single unit spikes in RVLM following intravenous injection of nitroprusside and phenylephrine. The effects of GABA and glutamate injected into the lateral ventricle were studied in single neuronal activity of the RVLM in addition to changes in BP and heart rate, and compared the results before and after treatment with intravenous losartan, nonpeptide Ang II-type 1 receptor antagonist (1 mg/100 g BW). Intracerebroventricular administration of GABA decreased systolic blood pressure (SBP) and HR, but increased the firing rates in the RVLM. However, intracerebroventricular glutamate injection produced effects opposite to GABA. After pretreatment of intravenous losartan, the central effects of GABA on BP and firing rate in the RVLM were significantly attenuated and that of glutamate showed a tendency of attenuation. These results suggested that central GABA and glutamate regulated BP and firing rates in RVLM were inversely related to BP change. The central effects of GABA or glutamate on the autonomic nervous function were modulated by humoral factor, Ang II, by maintaining BP.

가로주행식 케미게이션 시스템의 개발 (Development of a Linear Chemigation System)

  • 구영모;배영환;박금주;정상옥
    • Journal of Biosystems Engineering
    • /
    • 제26권2호
    • /
    • pp.93-104
    • /
    • 2001
  • A linear chemigation system, integrating agrichemical appication units of pesticide and fertilizer into an irrigation system, was selected as a suitable model for the cost savings in farm management and automation. Technical designs were conducted in the areas of structure, power, drive, control, and hydraulic systems. An experimental farm was sectioned into the fields of 40m by 200m and systemized with the linear-move chemigation system of 36m in span. The chemigation system consisted of a base unit monitoring and controlling overall operation, and a driving unit traveling linearly and injecting agrichemicals. Monitoring and interlocking systems were utilized against unexpected malfunctions of power, injection and drive systems using radio freuency modems between the units. The system can be also modified to various farm sizes and stationary systems of indoor and outdoor.

  • PDF

양식장 배출수 수질관리를 위한 용존공기부상 공법의 운전 인자 영향 분석 (Analysis of the operating factors of dissolved air flotation (DAF) process for effluent quality improvement from aquaculture rearing tank)

  • 기재홍;김형준;이주영;한무영;강희웅
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.107-113
    • /
    • 2012
  • Pollutants in aquaculture system effluent mostly originated from solid wastes including uneaten feed and excreta of cultured species. In this research, DAF(Dissolved Air Flotation) unit is suggested as an integrated solid control unit especially as a form of IIBG(Inline Injection Bubble Generation) process in aquaculture system. Solid removal performance of DAF unit was examined under various operation and salinity conditions with turbidity and suspended solid. Solid waste removal efficiencies were found to be affected by operation conditions including saturator pressure, recycle ratio, coagulant concentration. Solid removal efficiency was higher under higher saturator pressure and recycle ratio under which condition larger number of bubbles is generated. Coagulant is thought to have important role in creating bubble-particle aggregate by showing better removal efficiency with higher concentration. However higher saline water showed less effectiveness in removing solids by DAF(IIBG). Application of DAF(IIBG) process also showed additional effect in phosphate removal and DO(Dissolved Oxygen) supply. Phosphate existed in polluted water was removed up to 46% after treatment, which is thought to attribute to aluminium phosphate precipitation. And DO concentration was found to increase over 50% of initial saturation concentration after the injection of micro-bubbles. Through experiments on solid removal from aquaculture effluent, DAF(IIBG) process is estimated to be effective solid control method. This property can help aquaculture system being installed and operated simply and effectively.

Racing Car ECU 의 제어에 의한 가속성능 향상에 관한 연구 (Electronic Control Unit Based Control of Racing Car to Enhance the Acceleration Performance)

  • 황의준;허장욱
    • 한국기계가공학회지
    • /
    • 제19권11호
    • /
    • pp.58-63
    • /
    • 2020
  • The fuel injection amount and timing along with the ignition timing for the gasoline engine of a racing car were adjusted using an electronic control unit (ECU), and the engine performance was evaluated through an acceleration test. The fuel map for the fuel injection amount and ignition map for the ignition timing were derived. Using the transient throttle control, the air-fuel ratio could be maintained at a constant value even in the case of a sudden throttle operation. In the flat shift, ignition blocking was more effective than fuel blocking. In a 75 m acceleration test, the required duration without and with ECU control was 4.47 s and 3.99 s, respectively. Notably, the acceleration could be improved by approximately 10.7% when the ECU control was implemented.

이산화탄소 격리저장시스템의 역학적 안정성 평가를 위한 주입온도 및 주입량 시나리오 해석 (Scenario Analysis of Injection Temperature and Injection Rate for Assessing the Geomechanical Stability of CCS (Carbon Capture and Sequestration) System)

  • 김아람;김형목
    • 터널과지하공간
    • /
    • 제26권1호
    • /
    • pp.12-23
    • /
    • 2016
  • 향후 국내에서 수행될 이산화탄소 지중저장 프로젝트의 성공적인 수행을 위해서는 현장 지질조건에 최적화된 주입 조건을 설계하는 것이 중요하다. 따라서 본 연구에서는 주입량 및 주입온도 등의 주입조건이 격리저장시스템의 역학적 안정성에 미치는 영향을 열-수리-역학 연계해석기법의 하나인 TOUGH-FLAC 해석기법을 이용하여 평가하였다. 저장시스템의 역학적 안정성은 기존 균열의 전단미끄러짐 발생가능성을 활동마찰각 및 응력원을 이용하여 분석하였다. 이산화탄소의 주입온도가 저류층의 초기온도보다 낮은 저온주입의 조건에도 열응력으로 인한 인장균열은 발생하지 않는 것으로 파악되었으나, 저류층에서 전단미끄러짐이 발생하는 결과를 보였다. 단위시간당 이산화탄소 주입량을 변화시킨 시나리오 해석에서는 단계별로 주입량을 감소시키는 주입시나리오에서 기존 균열들의 전단미끄러짐 발생 가능성이 가장 낮은 것으로 평가되었다.

The Mold Close and Open Control of Injection Molding Machine Using Fuzzy Algorithm

  • Park, Jin-Hyun;Lee, Young-Kwan;Kim, Hun-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.575-579
    • /
    • 2005
  • In this paper, the development of an IMM(Injection Molding Machine) controller is discussed. Presently, the Mold Close and Open Control Method of a toggle-type IMM is open-loop control. Through the development, a PC based control system was built instead of an existing controller and a closed-loop control replaced the previous control method by using PC based PLC. To control the nonlinear system of toggle type clamping unit, a fuzzy PI control algorithm was selected and it was programmed by an IL(Instruction List) and a LD(Ladder Diagram) on a PC based PLC. The application of fuzzy algorithm as the control method was also considered to change a control object like a mold replacement or an additional apparatus. For the development of an IMM controller, PC based PLC of PCI card type, distributed I/O modules with CANopen and Industrial PC and HMI (Human Machine Interface) software were used.

  • PDF