• Title/Summary/Keyword: Unit Master Control

Search Result 61, Processing Time 0.033 seconds

Study of improvement control logic about unit master control(UMC) (Unit master control(UMC) 제어로직 개선에 관한 연구)

  • Park, Doo-Yong;Lim, Gyun-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1707_1708
    • /
    • 2009
  • Unit master control(UMC)는 발전소의 요구 부하신호를 설정하는 최상위의 제어레벨이며 UMC의 설정값은 자동급전 지령신호(Automatic Dispatch System : ADS) 또는 운전원이 설정하는 값에 따라 보일러 및 터빈 Master에 Unit 요구 신호를 출력하여 하위제어 레벨인 공기, 연료, 급수 등을 조절할 수 있는 기기에 Unit 부하 요구 신호(Unit Load Demand : ULD)에 따라 제어 되도록 하는 방법으로서, Unit 목표부하 설정, Unit 목표부하 상/하한 제한, 목표부하 변화율 제한, 주파수 보정, Runback/Rundown/ Runup, 보일러 및 터빈 Demand 신호생성의 기능을 가지고 있다.

  • PDF

Unit Master and Boiler Master control Logic Analysis of ABB-P14 Control System (ABB-P14 제어시스템의 Unit Master and Boiler Master 제어로직 분석)

  • Park, Doo-Yong;Lim, Ik-Hun;Lim, Geon-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1826-1827
    • /
    • 2011
  • 발전소 제어시스템은 여러개의 제어루프가 있으면 이중 가장 중요한 것은 Unit master control(UMC)와 Boiler master control(BMC)이다. 전력거래소에서 발전기 출력 증발/감발 요구에 의해 가장먼저 BMC가 콘트롤 되어야 하고, 이어서 터빈 컨트롤이 추종하고 있기 때문이다. ABB P-14 제어시스템의 UMC의 각종기능과 구성에 대해 분석한 내용을 논하고자 한다.

  • PDF

Module Type Parallel Driving Algorithm for High Voltage Direct-Current source (고전압 소스를 위한 모듈식 병렬운전 알고리즘)

  • Woo, Byung-Guk;Lee, Yong-Hwa;Kang, Chan-Ho;Cho, Kwan-Yuhl
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.24-27
    • /
    • 2008
  • For high voltage DC-DC converters, the parallel operation of several high voltage source modules is necessary to reduce the material cost. In the conventional parallel operation with HDC module control unit, it is difficult to repair the HDC system for the failure of control unit. To overcome these problems, new parallel operating algorithm for high voltage DC-DC converter is presented. The proposed algorithm has no main control unit and each module can be selected as the master according to the operating conditions. Therefore, one of modules can be replaced as the master immediately when the previous master module is failed. In addition, the extension of extra modules can be simple.

  • PDF

Network Method for Automation Factory Processor (자동화 공정을 위한 네트웍 구현)

  • Kim, Jee-Hong;Hwang, Byung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2483-2485
    • /
    • 2003
  • As design a network system that should command and response to do tasks by PLC, to make factory automation for being distributed facilities which are not guaranteed procedure, through polling method, commands are send orderly by PLC and responses are answered by each sub-unit. It make a guarantee of sequence and drive a master-slave operation in network. This method help to distribute procedure systems and make possible dividing tasks to each unit. To make this method, network protocol's format have Master or Slave ID and tasking data and Master's command or Slave unit's report. In network interpret algorithm, skip algorithm are included and it make guarantee of protecting data though network are in noise. Data that are made by this method are send to PC to transmit long-distance user by internet.

  • PDF

The Development of Boiler Feedwater Master Control System for Power Plant (발전소 보일러 급수 주제어 시스템의 개발)

  • Lim, Gun-Pyo;Park, Doo-Yong;Kim, Jong-Ahn;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.442-450
    • /
    • 2012
  • Almost domestic power plants are being operated by foreign distributed control system. Many korean power plants are being operated over their lifetime so they need to be retrofitted. So we are developing the distributed control system to solve this problem by our own technique. The simulator was already made to verify the reliability of the algorithms. The unit loop function tests of all algorithms were finished in the actual distributed control system for installation of power plant and their results were satisfactory. The unit loop function tests are for each unit equipment algorithm. So the total operation tests will be made with all algorithms together in the actual distributed control system to be applied to power plant. When the verification through all tests is finished, algorithms with hardware will be scheduled to be installed and operated in the actual power plant. This research result will contribute to the safe operation of the deteriorated power plant and korean electric power supply as well as domestic technical progress. This entire processes and results for the development are written for the example of boiler feedwater master algorithm out of all algorithms in this paper.

An analysis of Change on the Apartment Unit Plans Based on the Interior Spaces for Women (여성 공간을 중심으로 본 수도권 아파트의 공간구조 변화)

  • Choi, Byung-Sook;Park, Jung-A
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.354-359
    • /
    • 2008
  • The purpose of this study is to find out the changes on the metropolitan apartment unit plans based on the interior spaces for women such as master bedroom, bathroom and attached spaces to the master bedroom, living room, diningroom, kitchen, utility room, and balcony. This study used the content analysis method, space syntax. Contents were the floor plans with 3 rooms type and limited to about $105m^2$ among drawings of an apartment encyclopedia. Above all, 174 unit plans were analyzed until now. Specifically, using $S^3$-Convex program, the integration and control value periodically of the interior spaces for women(master bedroom, bathroom and attached spaces to the master bedroom, living room, diningroom, kitchen, utility room) is understood. Second, using SPSS package 16.0, relative size of the interior spaces for women on the unit floor plan is understood periodically. Finally, the changes on the apartment unit plans based on a woman' aspect after 1980's is reanalyzed.

  • PDF

The Strategy Design of Control Logic for Ultra Super-Critical Power Plant Boiler (초초임계압 발전소 보일러 제어전략 설계)

  • Park, Doo-Yong;Kim, Byung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.223-224
    • /
    • 2008
  • 초초임계압 화력발전 제어계통 설계와 관련하여 보일러 제어시스템의 기본 요건인 제어전략을 구현하기 위해 현재 표준화력 500MW 제어시스템과 제어로직을 기반으로 1000MW급에서 필요로 하는 새로운 구조의 제어에 요구되는 제어전략에 대해 각종 제어 운전 모드의 구성과 각 운전 모드에서의 제어전략을 개발하고 있다. 최신제어시스템에서 중요하게 취급되는 자동 플랜트 제어(Automatic Plant Control, APE)의 각종 제어전략 구성에 중점을 두고 있으며 Unit Master Control, Boiler Master Control, Turbine blaster Control, Throttle Pressure Control, Fuel/Air Master Control, Forced Draft Fan Control, Induced Draft Fan Control, Primary Air Fan, Feed Water Master Control, Super Heater/Reheater Steam Temp Control 등의 제어전략을 논하고, 실제 프로세스 응단특성 파악을 위해 국내 신규발전소를 방문하여 수집한 프로세스 응답시험 결과와 특성을 분석하고 USC에 적용하기위한 보일러 제어전략에 대해 논하고자 한다.

  • PDF

Tele-Operation System for Excavator using LTE Communication (LTE 통신을 사용한 건설용 굴삭기 원격조종시스템 개발)

  • Lee, Seung Chol;Kang, Byoung Hun
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.3
    • /
    • pp.232-237
    • /
    • 2021
  • In this research, a real-time tele-operation system for unmanned excavator using the LTE communication system is suggested. The distance between the operator and the excavator is limitless as long as the LTE communication available. The motion and video data of the excavator is synchronized using the Vehicle Control Unit (VCU) and streamed to the operator for immersion feeling. The video is played on the operator's monitor and the motion data is used to regenerate the excavator movement on the developed master platform. In general, a excavator is tele-operated using RF signal and the maximum distance for direct control is limited to within a hundred meter. In this research, the immersion tele-operation system is suggested for excavator operation within an 100ms time delay using the developed master platform, the VCU and LTE communication. A successful test run of the suggested tele-operation system has already been performed between an operator in Songpa (Seoul) and a excavator in Ansan (Gyeonggi-do) which is approximately 35 km apart.

Key Management and Recovery Scheme over SCADA System Using ID-based Cryptosystem (ID 기반 암호 기법을 이용한 SCADA 시스템에서 비밀 키 관리 및 복구 방안)

  • Oh, Doo-Hwan;Choi, Doo-Sik;Na, Eun-Sung;Kim, Sang-Chul;Ha, Jae-Cheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.3
    • /
    • pp.427-438
    • /
    • 2012
  • The SCADA(Supervisory Control and Data Acquisition) systems are used to control some critical national infrastructures such as electricity, gas, and water distribution systems. Recently, there are many researches on key management scheme for secure communication due to change to the open network environment. We propose a new key management method which is established on ID-based cryptosystem using pairing on MTU(Master Terminal Unit), Sub-MTU, and RTU(Remote Terminal Unit). Furthermore, we present a redistribution protocol of private key of each device and a system recovery protocol as a countermeasure of exposure of KMS(Key Management System) master key which is occurred by some unexpected accidents or malicious attacks.

Design of FPGA in Power Control Unit for Control Rod Control System (원자로 제어봉 구동장치 제어시스템용 전력제어기 FPGA 설계)

  • Lee, Jong-Moo;Shin, Jong-Ryeol;Kim, Choon-Kyung;Park, Min-Kook;Kwon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.563-566
    • /
    • 2003
  • We have designed the power control unit which belongs to the power cabinet and controls the power supplied to Control Rod Drive Mechanism(CRDM) as a digital system based on Digital Signal Processor(DSP). The power control unit dualized as the form of Master/Slave has had its increased reality. The Central Process Unit(CPU) board of a power control unit possesses two Digital Signal Processors(DSPs) of the control DSP for performing the tasks of power control and system monitoring and the communication of the Control DSP and the Communication DSP. To accomplish the functions requested in the power control unit effectively, we have installed Field Programmable Gate Arrays(FPGAS) on the CPU board and have FPGAs perform the memory mapping, the generation of each chip selection signal, the giving and receiving of the signals between the power controllers dualized, the fault detection and the generation of the firing signals.

  • PDF