• Title/Summary/Keyword: Unipolar switching

Search Result 41, Processing Time 0.032 seconds

Comparison Study of EMI and Switching Loss Reductions of Unipolar and Improved Limited Unipolar Switching Circuits

  • Fujimoto, Takashi;Park, Kyihwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.152.2-152
    • /
    • 2001
  • This paper investigates the effect of the conducted EMI Electromagnetic Interference and the switching loss which occurs from the switching devices in the switching period of the unipolar and limited unipolar switching circuits. The three main sources of conducted EMI and switching loss in the unipolar and limited unipolar switching circuit come from the switching devices, the number of switching times in the switching period and their switching waveform. In this paper, these three parameters are used to determine the conducted EMI which generated from the unipolar and limited unipolar switching circuits and to improve the limited unipolar switching circuit which uses the power MOSFET´s as the switching devices. The significant reduction of Ire conducted EMI ...

  • PDF

Research of PWM Modulation for Regeneration Braking of BLDC Motor (BLDCM의 회생제동을 위한 스위칭 방식에 관한 연구)

  • Kim, Yong-Hyu;Park, Sung-Jun;Jung, Jun-Hyung;Kim, Dong-Youn;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.193-199
    • /
    • 2015
  • This paper proposes a regeneration braking algorithm for Brushless DC (BLDC) motor system. The unipolar switching method has a limitation about the regeneration braking when the BLDC motor is operated in the low speed region. The proposed algorithm alternatively utilizes the unipolar and bipolar switching method to implement the regeneration braking for overall speed range. The bipolar switching method is used when the BLDC motor is operated in the low speed region. The switching transition point is determined by analyzing the unipolar and bipolar switching during the regeneration braking. The effectiveness of proposed algorithm is verified by using the experimental results.

An Improved SPWM Strategy to Reduce Switching in Cascaded Multilevel Inverters

  • Dong, Xiucheng;Yu, Xiaomei;Yuan, Zhiwen;Xia, Yankun;Li, Yu
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.490-497
    • /
    • 2016
  • The analysis of the switch status of each unit module of a cascaded multi-level inverter reveals that the working condition of the switch of a chopper arm causes unnecessary switching under the conventional unipolar sinusoidal pulse width modulation (SPWM). With an increase in the number of cascaded multilevel inverters, the superposition of unnecessary switching gradually occurs. In this work, we propose an improved SPWM strategy to reduce switching in cascaded multilevel inverters. Specifically, we analyze the switch state of the switch tube of a chopper arm of an H-bridge unit. The redundant switch is then removed, thereby reducing the switching frequency. Unlike the conventional unipolar SPWM technique, the improved SPWM method greatly reduces switching without altering the output quality of inverters. The conventional unipolar SPWM technique and the proposed method are applied to a five-level inverter. Simulation results show the superiority of the proposed strategy. Finally, a prototype is built in the laboratory. Experimental results verify the correctness of the proposed modulation strategy.

The Development of Calculation Algorithm of Power Loss for Inverter in BLDC Motor Drive with Switching Modes (스위칭 방식에 따른 BLDC Motor 구동용 인버터의 전력 손실 계산 알고리즘 개발)

  • Kim, Sang-Hoon;Lee, Young-Cheol
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.119-126
    • /
    • 2004
  • BLDC Motor is one of the widely utilizable motors in servo system. The accurate calculation of the power loss for the IGBT and Inverse diode with Bipolar and Unipolar switching modes the driving modes is important for the design of drives for their heat treatment. If it were not for temperature-sensors in devices, it is difficult to get direct power loss, so. Power losses may be modeled by computer modeling to obtain the Calculation of the Power loss for Inverter in BLDC Motor with switching modes which is presented in this paper. The computer modeling is carried out by Matlab simulation. The power loss consists of conduction losses Conduction losses are the source of occurrence due to The IGBT and Inverse diode currents. Switching losses are the source of occurrence due to switching on/off in the devices, and gives the dominant influence to the loss. As a result, the unipolar I mode is best in reducing the heat losses.

  • PDF

Resistive Switching Characteristics of Amorphous GeSe ReRAM without Metalic Filaments Conduction

  • Nam, Gi-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.368.1-368.1
    • /
    • 2014
  • We proposed amorphous GeSe-based ReRAM device of metal-insulator-metal (M-I-M) structure. The operation characteristics of memory device occured unipolar switching characteristics. By introducing the concepts of valance-alternation-pairs (VAPs) and chalcogen vacancies, the unipolar resistive switching operation had been explained. In addition, the current transport behavior were analyzed with space charge effect of VAPs, Schottky emission in metal/GeSe interface and P-F emission by GeSe bulk trap in mind. The GeSe ReRAM device of M-I-M structure indicated the stable memory switching characteristics. Furthermore, excellent stability, endurance and retention characteristics were also verified.

  • PDF

A New Switching Method for Reducing switch loss of Single-phase three-level NPC inverter (스위치 손실 감소를 위한 단상 3레벨 NPC 인버터의 새로운 스위칭 방법)

  • Lee, Seung-Joo;Lee, June-Seok;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.268-275
    • /
    • 2015
  • This paper proposes a method of switching to improve power loss for the single-phase three-level NPC inverter. The conventional switching methods, which are called as the bipolar and unipolar switching methods, are used for single phase inverters using three-level topology. However, these switching method have disadvantage in the power loss. Because all of the switch are operated. To reduce the power loss of the three-level NPC inverter, clamp switching method is introduced in this paper. This way, one of the lag is fixed that switching loss is reduced. This paper analyzes and compares power losses of unipolar method and clamp method. The validity of the power loss analysis is verified through the simulation and experimental results.

Reproducible Resistance Switching and Physical Characteristics of TiOx films with Oxidation Temperature and Time

  • Kim, Jong-Gi;Na, Hee-Do;Sohn, Hyun-Chul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.171-171
    • /
    • 2010
  • In this work, we investigated the effect of the oxidation temperature on the unipolar and bipolar resistance switching behaviors of the oxidized TiO-x films. TiOx films on Pt electrodes were fabricated by the oxidation of Ti films at $550^{\circ}C$ for 1 to 3 hours. The unipolar and bipolar resistance switching properties were investigated with the oxidation temperature and time. Also, the crystal structure and the physical properties such as chemical bonding states of TiOx layers were characterized in addition to the resistance switching characteristics. The resistance switching behaviors of TiOx films oxidized at above $450^{\circ}C$ and below $650^{\circ}C$ was shown. So, we investigated that the resistance switching behaviors of TiOx films oxidized at $550^{\circ}C$ with the oxidation time from 1 to 3 hour. The memory windows of unipolar switching in the oxidized TiOx films were reduced with increasing the oxidation time, but those of the bipolar switching were slightly enlarged. The enlargement of rutile TiO2 peak with increasing the oxidation time and temperature was studied by X-ray diffraction. An increase of non-lattice oxygen and Ti3+ in the TiOx films with the oxidation times was investigated by X-ray photoemission spectroscopy. It was expected that the uipolar and bipolar resistive switching of the oxidized TiOx film was strongly related with the migration of non-lattice oxygen anions and schottky barrier height, respectively.

  • PDF

A PWM Method for Reduction of Switching Loss in High Speed Motor (초고속 전동기에서의 스위칭 손실 절감을 위한 PWM 방식)

  • Kim, Yoon-Ho;Lee, Byung-Soon;Oh, Jong-Han;Seoung, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.616-618
    • /
    • 1996
  • This paper presents an unipolar PWM which commutated switching device only in a half period. This method reduced switching loss significantly because of decreasing switching number in n period. In high speed motor drive needed high frequency above 300 Hz fundamental frequency, this method is suited very well. This paper described the principle of unipolar PWM method, analyzed harmonic spectrum and compared with bipolar PWM, Modified PWM and Overmodulation method in switching loss.

  • PDF

Efficient Switching Pattern to Decrease Switching Losses in Cascaded H-bridge PWM Multilevel Inverter (Cascaded H-bridge PWM 멀티레벨인버터의 스위칭 손실 저감을 위한 효율적인 스위칭 패턴)

  • Jeong, Bo Chang;Kim, Sun-Pil;Kim, Kwang Soo;Park, Sung-Jun;Kang, Feel-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.502-509
    • /
    • 2013
  • It presents an efficient switching pattern, which expects a reduction of switching losses in a cascaded H-bridge PWM multilevel inverter. By the proposed switching scheme, the lower H-bridge module operates at low frequency of 60[Hz] because it assigns to transfer most load power. The upper H-bridge module operates at high frequency of PWM switching to improve THD of output voltage. The proposed switching pattern applies to cascaded H-bridge multilevel inverter with PD, APOD, bipolar, and unipolar switching methods. By computer-aided simulations, we verify the validity of the proposed switching scheme. Finally, we prove that the proposed PD and APOD switching patterns are better than those of the conventional one in efficiency.

An Improved Single-Phase Full-Bridge ZVS Inverter with a Subtractive Coupled Magnetics

  • Soh, Jae-Hwan;Lim, Jong-Yeop;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1835-1841
    • /
    • 2017
  • An improved single-phase full-bridge zero-voltage-switching inverter using a subtractive coupled magnetics is proposed in this paper. The proposed topology overcomes several drawbacks of the conventional ARCPI zero-voltage-switching inverter including two bulky capacitors which can cause problems such as the need for a protection circuit and voltage fluctuation of split capacitors. Also the proposed topology can reduce the number of devices required for ZVS through a simplified auxiliary circuit, thus achieving low cost and small volume and is applicable a modified unipolar PWM scheme. Detail mode analysis and design considerations are provided for optimal efficiency. In the end, the effectiveness and feasibility of the proposed topology are verified experimentally under various conditions.