• Title/Summary/Keyword: Uninterruptible Power System

Search Result 156, Processing Time 0.025 seconds

New Configuration of 36-pulse Voltage Source Converter Using Pulse-Interleaving Auxiliary Circuit (펄스다중화 보조회로를 이용한 새로운 구조의 36-펄스 전압원 컨버터)

  • Jon Young-Soo;Baek Seung-Taek;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.238-244
    • /
    • 2005
  • This paper proposes a new configuration of 36-pulse voltage source converter which consists of two 6-pulse bridges and a pulse-interleaving auxiliary circuit. The system topology of proposed converter was derived to increase the pulse number of converter output voltage without increasing the number of 6-pulse bridges. The gate pulse generation was analyzed using the theoretical approach of multi-pulse switching converter, The operational feasibility of proposed system was verified by computer simulations with PSCAD/EMTDC software and experimental works with 2kVA hardware prototype. The proposed converter can be widely used for the uninterruptible power supply, the power quality compensator, and the distributed power generation, such as solar and fuel cell power system.

The Construction-Case of Intelligent Power Management System (지능형 전력관리시스템의 구축사례)

  • 고강훈;김천식;김수용;박정우;고희석;이현우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.214-218
    • /
    • 2000
  • This paper is a study if control system with KEN that is not only superior-manufacture ability-hardware; that is to say, the hardware is HMI/SACD solution and it has been developed to sub-station and power management system, which is easy, fast and suitable for users to work with, but also compatible solution with domestic environment Futhermore, the hardware has been developed by completely domestic technology with knowledge from various actual experiences. In the long run, for uninterruptible power supply to train, building, and factory, real time tele-supervisory control to power facilities.

  • PDF

New Configuration of 36-pulse Voltage Source Converter Using Pulse-Interleaving Auxiliary Bridge Circuit (펄스다중화 보조브리지회로를 이용한 새로운 구조의 36-펄스 전압원 컨버터)

  • Han, B.M.;Baek, S.T.;Jon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.31-35
    • /
    • 2004
  • This paper proposes a new configuration of 36-pulse voltage source converter which consists of two 6-pulse bridges and a pulse-interleaving auxiliary circuit. The system topology of proposed converter was derived to increase the pulse number of converter output voltage without increasing the number of 6-pulse bridges. The gate pulse generation was analyzed using the theoretical approach of multi-pulse switching converter. The operational feasibility of proposed system was verified by computer simulations with PSCAD/TMTDC software and experimental works with 3kVA hardware prototype. The proposed converter can be widely used for the uninterruptible power supply, the power quality compensator, and the distributed power generation, such as solar and fuel fell power system.

  • PDF

A Development of Energency Power Automatic Transfer Module in home (가정용 비상 전원 절체 모듈 개발)

  • Joo, Nam-Kyu;Kim, Kwan-Yuong;Kim, Nam-Ho;Lee, Jong-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.321-323
    • /
    • 2009
  • When power failure occurs at multi-housing complex, auxiliary generator or emergency generator starts to provide power to households. This power is connected to emergency power ELB(Earth Leakage Breaker) at home distribution panel board and supplies power only for emergency light in living room but for heating system, refrigerator and other inevitable apparatuses that are in need of uninterruptible power. Since those domestic appliance are fed from common power line, they are inoperable during power failure. Our research is to resolve this problem by developing compatible relay-drive common/emergency-power ATS (automatic transfer switch) for home distribution panel board. In case of power failure, it transfers automatically and commences to provide power from emergency generator. Through this, Consumers can reach satisfaction where common power loads operate without any problem under both ordinary and power failure condition.

  • PDF

Dynamic Voltage Compensator using Series and Shunt Inverters (직.병렬 인버터를 이용한 동적전압보상기)

  • Park, Deok-Hui;Lee, Jun-Gi;Han, Byeong-Mun;So, Yong-Cheol;Kim, Hyeon-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.655-662
    • /
    • 1999
  • This paper describes controller design and simulation-model development of a dynamic voltage compensator using series and shunt inverters. The control system was designed using PI controller and vector relationship between the supply voltage and load voltage. A simulation model with EMTP was developed to analyze performance of the controller and the whole system. The simulation and experiment results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system, such as single-line-ground fault, three-line-to-ground fault, and line-to-line fault.

  • PDF

A Research on the Optimal System Sizing of the Standalone Photovoltaic Power Generation System for Uninterruptible Power Supply (독립형 태양광 발전 시스템의 무정전 전력공급을 위한 시스템 용량 최적 선정에 관한 연구)

  • Kim, Ki-Young;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.68-69
    • /
    • 2017
  • 본 논문에서는 독립형 태양광 시스템의 설계에서 배터리 용량 선정 방식에 관련하여 부하손실확률(LLP: Loss of Load Probability)이 0 인 기준을 토대로 시스템 무정전 전력공급을 위한 시행 착오법을 제안하였으며 시스템의 수명주기비용(LCC: Life Cycle Cost)을 분석하여 기존 시스템에 비해 경제성을 높이고자 한다. 제안한 방식의 검증을 위하여 시뮬레이션을 수행하였다.

  • PDF

Implementation of inside the computer power supply with UPS (UPS 기능을 갖는 내장형 컴퓨터 전원장치의 구현)

  • Lee S. R.;Ko S. S.;Mun J. M.;Kwon H. D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.202-205
    • /
    • 2003
  • Recently, UPS(Uninterruptible Power Supply) have been largely used to improve power souse quality as well as to protect critical loads such as computer, industrial system, medical equipment, etc, against power outage by providing clean and uninterrupted power under power supply disturbance or interruptions. But UPS is bulky because used battery. So, UPS size issue have received attention in the power electronics industry. Therefore, this paper proposed a implementation of inside of the computer power supply with UPS by the one-chip microprocessor to minimize UPS size. To verify the proposed power supply, the detail simulation and experiment results indicate that high-frequency switching and operation UPS can be achieved.

  • PDF

Design and Control Method for Critical Load Supply Equipment using MCFC Electricity Generation Systems (대용량 MCFC 발전시스템을 이용한 비상부하 전력 공급 장치 설계 및 제어방법)

  • Kim, Dong-Hee;Kim, Jong-Soo;Choe, Gyu-Yeong;Lee, Byoung-Kuk;Kawk, Cheol-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.20-29
    • /
    • 2011
  • This paper proposes critical load following back-up system using MCFC stack. This system enables MCFC generation system to supply power to critical load without UPS and to generate rated power under grid fault state. This back-up system includes 'Load Leveler' that is connected with 3-phase inverter and is controlled by additional algorithm that includes critical load following. The proposed system and algorithm are verified by computer simulation based on 5kW system.

Failure Prediction Monitoring of DC Electrolytic Capacitors in Half-bridge Boost Converter (단상 하프-브리지 부스트 컨버터에서 DC 전해 커패시터의 고장예측 모니터링)

  • Seo, Jang-Soo;Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.345-350
    • /
    • 2014
  • DC electrolytic capacitor is widely used in the power converter including PWM inverter, switching power supply and PFC Boost converter system because of its large capacitance, small size and low cost. In this paper, basic characteristics of DC electrolytic capacitor vs. frequency is presented and the real-time estimation scheme of ESR and capacitance based on the bandpass filtering is adopted to the single phase boost converter of uninterruptible power supply to diagnose its split dc-link capacitors. The feasibility of this real-time failure prediction monitoring system is verified by the computer simulation of the 5[kW] singe phase PFC half-bridge boost converter.

Fabrication of Battery Checking & Monitoring System (밧데리 진단 및 감시장치 제작)

  • Lee, Sang-Cheol;Na, Chae-Dong;Yoo, Jae-Moon;Choi, Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2156-2159
    • /
    • 1998
  • This paper describes a Battery Checking & Monitoring System for monitoring battery cell and power system in Uninterruptible Power Supplies(UPS). The system is capable of measuring, in a matter of setting time, float and discharge voltage of up to 240 cells in a single installation, and has the memory capacity to store battery's alarm data information on up to 200 separate sites. This system are easy to maintain and attain cost effectively, so that prepared for meeting the customer's service needs immediately. The system is additionally programmed with a each model, that will enable to accurately determine the remain battery capacity in a UPS system following a short discharge test. It is also equipped with remote interrogation and control facilities.

  • PDF