• Title/Summary/Keyword: Uninterruptible

Search Result 221, Processing Time 0.031 seconds

UPS의 이해

  • 이승태
    • Product Safety
    • /
    • s.91
    • /
    • pp.64-65
    • /
    • 2001
  • UPS(Uninterruptible Power Supply)는 우리말로는 무정전전원장치(無停電電源裝置)라고 하는데, 정전(停電 : Stoppage of Electric Current)과 같은 전원장애(電源障碍)가 발생한 경우 UPS에 접속되어 잇는 기기에 지속적으로 전원을 공급하는 장치를 말한다. UPS방식에는 상시 인버터방식, 상시 상용방식, 라인 인터랙티브방식의 세가지가 있다.

  • PDF

Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply (USP의 신뢰성 향상을 위한 독립제어 고속절환장치)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.278-286
    • /
    • 2008
  • This paper investigates the fault generation type and the cause of output interruptionsin bulky with $30^{\sim}500[KVA]$ double conversion UPS, and proposes the fault detection method to improve the reliability of power supply used in the critical load in industry. Identifies its existing way of detecting a quality of inverter output it to bypass when exceeds its expectation. Under a UPS managing system, when an inner (Power device, Controller, CPU) fault occurs it disrupts the power supply and these occurrences has been verified by the results of experiments and application results. To overcome these problems, the proposed method constructs independently a fault-detection, a bypass-control device and a triple power supply apart from the conventional UPS operation. Also the detection point is changed to the preceding of a circuit breaker, a reference of fault detection is modified to avoid any clash and the breaking equipment is attached to intercept a spread of accident. As a result of applications of these developed systems to 242 UPS which was installed purposefully to the communication power supply, the service errors has not occurred in the UPS for two years since 2006.

Dynamic Characteristic of the Seismic Performance of Uninterruptible Power Supply with Combined Isolator Using Shaking Table Test (복합면진장치를 적용한 무정전전원장치의 1축 진동대실험 기반 동적특성 분석)

  • Lee, Ji-Eon;Lee, Seung-Jae;Park, Won-Il;Choi, Kyoung-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.19-28
    • /
    • 2022
  • In this study, three types of combined isolator consisting of High Damping Rubber Bearing (HDRB) and wire isolator were developed for Uninterruptible Power Supply system (UPS). The dynamic characteristics of the combined isolator were investigated through one-axis shaking table test. The input acceleration were generated in accordance with ICC-ES AC156 code. Scale factors of the input acceleration were designed to be 0.5-2 times the required response spectrum defined in ICC-ES AC156. Based on the test results, damage and dynamic characteristics of the UPS were investigated: including natural frequency, damping ratio, acceleration time history response, dynamic amplification factor and relative displacement. Based on that, it was found that the combined isolator developed in this study could improve the seismic behavior of the UPS, in particular, the response acceleration.

A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator (새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구)

  • Kwak, A-Rim;Park, Seong-Mi;Son, Gyung-Jong;Park, Sung-Jun;Kim, Jong-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

Model Predictive Control of Three-Phase Inverter for Uninterruptible Power Supply Applications under a Hexagonal Input Constraint Region (육각형 입력제약 공간을 이용한 무정전 전원장치의 모델예측제어)

  • Kim, Seok-Kyoon;Kim, Jung-Su;Lee, Young Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Using the classical cascade voltage control strategy, this paper proposes an analytical solution to an MPC (Model Predictive Control) problem with a hexagonal input constraint set for the inner-loop to regulate the output voltage of the UPS (Uninterruptible Power Supply). Focus is placed on how to deal with the hexagonal input constraint set without any approximation. Following the conventional cascade voltage control strategy, the PI (Proportional-Integral) controller is used in the outer-loop in order to regulate the output voltage. The simulation results illustrate that the capacitor voltage rapidly goes to its reference in a satisfactory manner while keeping other state variables bounded under an unexpected load changes.

A PCS Control Strategy for Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 하이브리드 ESS를 위한 PCS 제어전략)

  • Kim, Sang-Jin;Kwon, Min-Ho;Choi, Se-Wan;Paik, Seok-Min;Kim, Mi-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.302-311
    • /
    • 2016
  • This paper proposes a hybrid ESS that integrates an energy storage system (ESS) with an uninterruptible power supply (UPS). The hybrid ESS has a demand management and emergency power supply function while increasing the battery utilization of the UPS, which has just been used in a power failure. In addition to the critical load, the proposed system augments the capacity of emergency generation using an additional load, which has voltage and frequency-dependent characteristics to the grid side. The control algorithm of the AC-DC converter and bidirectional DC-DC converter is proposed for demand management and emergency power supply. Furthermore, seamless and autonomous transfer methods to alleviate the transient during mode transfer are proposed. To validate the proposed control scheme, experimental results from a 5 kW prototype are provided.

DEVELOPMENT OF MULTI-FUNCTIONAL UNINTERRUPTIBLE POWER SUPPLY USING INSULATED GATE BIPOLAR TRANSISTORS (IGBT를 이용한 다기능 무정전전원 공급장치 (UPS)개발)

  • Kim, D.U.;Shin, H.J.;Kim, Y.P.;Baek, B.S.;Ryu, S.P.;Min, B.G.;Choi, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.573-575
    • /
    • 1994
  • Resent research activities and technical trends for UPS(UNINTERRUPTIBLE POWER SUPPLY) are reviewed. There are increasing demands for UPS to get mote useful performance. This needs are high-efficiency, high-confidency, high-quality, low-cost. self-diagnosis. maintenance-free, and a wide variety of options. These can be satisfied with high-technology and optimal system coordination. In this paper. according to these demands. a newly developed UPS and a wide variety of options are introduced. Also. the data related are presented.

  • PDF

Evaluation Algorithms for Multiple Function of Dispersed Electrical Energy Storage Systems

  • Son, Joon-ho;Choi, Sung-Sik;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2245-2253
    • /
    • 2018
  • With the increase of electrical consumption and the unbalance of power demand and supply, power reserve rate is getting smaller and also the reliability of the power supply is getting deteriorated. Under this circumstance, the electrical energy storage (EES) System is considered as one of essential countermeasure for demand side management. This paper proposes efficient evaluation algorithms of multiple functions for EES systems, especially the secondary battery energy storage systems, in the case where they are interconnected with the power distribution systems. It is important to perform the economic evaluation for the new energy storage systems in a quantitative manner, because they are very costly right now. In this paper, the multiple functions of EES systems such as load levelling, effective utilization of power distribution systems and uninterruptible power supply are classified, and then the quantitative evaluation methods for their functions are proposed. From the case studies, it is verified that EES systems installed at distribution systems in a dispersed manner have multiple functions involved with direct and indirect benefits and also they can be expected to introduce to distribution systems with respects to economical point of view.

Parallel Operation of Three-Phase Four wire UPS using Droop Control (Droop Control을 이용한 3상 4선식 UPS의 병렬운전)

  • Kim, Hyunseob;Han, Jungho;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.88-95
    • /
    • 2013
  • A new droop control method which can be applied to 3-phase 4-wire uninterruptible power supply is proposed in this paper. The droop control method for parallel operation is very attractive one as UPS parallel operation can be carried out without any data communication devices provided among UPS systems connected, but it reportedly shows a PnP(plug-and-play) problem. A basic reason why a circulating current could flow among parallel-connected UPS systems is clearly investigated as well when droop-controlled-ups systems are operated in the manner of PnP. The proposed algorithm is deduced from the investigated result and is basically structured to keep a balanced frequency and balanced voltage profile against power variation. This paper shows that balanced parallel operation of droop control method can be obtained under unbalanced load as well as balanced load conditions when PnP operation is needed and load change occurs.