• 제목/요약/키워드: Uniform Heating

검색결과 278건 처리시간 0.028초

유도가열 시스템에서 축대칭도전체의 와전류 유한요소 해석 (Axi-symmetric eddy currents analysis by FEM)

  • 최경호;안창회;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.119-121
    • /
    • 1994
  • In solving axisymmetric field problem by FEM, absorbing boundary condition is introduced to approximate the normal derivatives on artificial boundary to truncate the finite analysis legion. To verify this scheme eddy currents of an conducting sphere in an uniform magnetic field are calculated, and it shows better results than one with Neumann boundary condition. Also eddy currents of conducting cylinder surrounded by coils are calculated, which is typical model in induction heating system.

  • PDF

핫플레이트를 균일온도로 가열하기 위한 카트리지히터 제작에 관한 연구 (A Study on Cartridge heater design for heating Hotplate to uniform surface temperature)

  • 홍재택;최신형;이봉섭;이진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.440-441
    • /
    • 2018
  • 본 연구에서는 핫플레이트를 균일한 표면 온도로 가열시키기 위한 카트리지 히터의 설계를 시도하였다. 이를 위하여 1. 표면 전력밀도 및 전열선 전력밀도에 따른 발열온도 측정 실험 2. 카트리지 히터의 분할 영역과 전열선 권선 비율에 따른 온도 측정 실험을 실시하여 온도분포형 카트리지 히터의 설계 사양을 선정하였다. 또한 이렇게 설계한 카트리지 히터를 직접 제작하여 기존의 표준형 카트리지 히터와의 성능 비교 측정 실험을 실시하여, 본 연구에서 제시한 방법으로 제작한 카트리지 히터의 표면 온도 균일도가 우수함(표면 온도차 ${\leq}1.25[^{\circ}C]$)을 증명하였다.

  • PDF

수직평판에 부착된 불연속 열원에 의한 자연대류에서 열원간의 열적 상호간섭에 관한 연구 (Effects of Thermal Interaction on Natural Convection From Discrete Heat Sources Mounted on a Vertical Plate)

  • 박흥수;추홍록;유갑종
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.39-47
    • /
    • 1998
  • The natural convection heat transfer in a vertical plate with discrete heat sources was studied experimentally. The particular interest was the thermal interaction of the heat sources. In this study, the radiative and conductive heat transfer were considered as heat loss, Thus, the net convective heat transfer rate was presented as adiabatic temperature and thermal wake function. As a results, for non-uniform heating condition, heat input ratio(q1/q2) was most dominant parameter for the thermal wake function. The convective heat transfer rate is decreased with the increasing of channel ratio. For the range of $7.50{\times}10^5<Rac<8.66{\times}10^6$, a useful correlation was proposed as a function of channel Rayleigh number.

  • PDF

ECR 플라즈마를 이용한 실리콘화박막증착 (Silicon Nitride Thin Film Deposition Using ECR Plasma)

  • 송선규;장홍영
    • 한국표면공학회지
    • /
    • 제23권4호
    • /
    • pp.218-224
    • /
    • 1990
  • Silicon nitride thin(SiNx) is deposited onto 3 inch silicon wafor using ECR plasma apparatus. For the two different plasma extraction windows size, the thin films which were deposited by changing the SiH4/N2 gas fole at at 1.5mTorr without substrate heating are analyzed through the XPS and wlliposometer measurements. The very uniform and good quality silicon nitride thin film were obtained with the analyzed results of the deposited films, and particularly, ion temperature perpendicular to the magnetic filed was nearly same as the neutral gas temperature. The large amount of plasma loss in the transport process following magnetic field lines could be seen from the plasma emission intensity measurements.

  • PDF

Synthesis of $La_{1-x}Sr_xCoO_3$ (x≤0.2) at Low Temperature from PVA-polymeric Gel Precursors

  • 권호진;박동곤;국승태;박휴범;김건
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권12호
    • /
    • pp.1249-1256
    • /
    • 1997
  • Single phase La1-xSrxCoO3 (x≤0.2) was synthesized as a uniform sized 100 nm particulates with relatively high surface area of 20-30 m2/g, at low temperature (≥600 ℃), from a polymeric gel precursors prepared by using poly(vinyl alcohol) as homogenizer. No minor phase developed during the crystallization when polymer/metal mole ratio was higher than 3. As the polymer/metal mole ratio was raised in the gel, the amount of carbonaceous residues in the amorphous solid precursor prepared by heating the gel at 300 ℃ increased. Most of the residues were eliminated by exothermic thermal decomposition around 400 ℃. The amount of residual carbon (less than 1%) left in the crystalline La1-xSrxCoO3 decreased as more polymer was used, eliminating detrimental effect which might be posed by using large amount of organic homogenizer. The crystal structure of La1-xSrxCoO3 synthesized at temperature lower than 800 ℃ was observed to be shifted from rhombohedral to more symmetric cubic. The structure shifted back to rhombohedral as the cubic sample was annealed at 1000 ℃.

테이퍼가 설치된 리브(rib)이 있는 채널의 열전달에 대한 수치해석 (Numerical Analysis of Heat Transfer in the Ribbed Channel Inserted with Tape)

  • 강호근;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.638-644
    • /
    • 2010
  • 사각 덕트내 열전달과 유동 양상을 조사하기 위해 꼬임식 테이프 만 설치한 경우와 꼬임식 테이프와 리브(rib)를 설치한 경우에 대해 충분히 발달된 난류유동에 관한 수치 해석을 행하였다. 수치 해석에서는 레이놀즈 수가 8,900에서 29,000 범위의 난류 스월유동, 채널수력직경에 대한 리브의 높이(e/$D_h$)가 0.067, 그리고 채널 수력 직경에 대한 시험부 길이(L/$D_h$)가 30인 경우에 대해 고려하였다. 리브는 채널 바닥면에 만 길이 방향으로 설치하였다. 꼬임식 테이프는 0.1 mm 두께의 탄소강 판 재질이며, 폭은 28 mm, 길이는 900 mm이고 2.5 번 회전시켰다. 각 벽면은 서로 단열된 알루미늄 판으로 구성되었다. 2가지의 가열 조건에 대해 조사 하였다: (1) 사각 전체 벽 면적에 일정한 열유속으로 가열, 그리고 (2) 사각 채널에서 마주보는 상하 양면 만 가열. 연구 결과 상하 양면 만 가열하는 경우가 4면 모두 가열하는 경우보다 열전달 계수가 우수하였고 꼬임식 테이프와 리브를 설치한 경우 열전달 계수가 현저히 향상되었다.

A Study on Numerical Simulation of Gaseous Flow in SCR Catalytic Filter of Diesel Exhaust Gas Aftertreatment Device

  • Bae, Myung-Whan;Syaiful, Syaiful;Mochimaru, Yoshihiro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.360-368
    • /
    • 2010
  • A SCR catalytic filter system is used for reducing $NO_x$ and soot emissions simultaneously from diesel combustors. The amount of ammonia (as a reducing agent) must be controlled with the amount of $NO_x$ to obtain an optimal $NO_x$ conversion. Hence, gas mixing between ammonia and exhaust gases is vital to ensure that the SCR catalyst is optimally used. If ammonia mass distribution is not uniform, slip potential will occur in rich concentration areas. At lean areas, on the other hand, the catalyst is not fully active. The better mixing is indicated by the higher uniformity of ammonia mass distribution which is necessary to be considered in SCR catalytic filter system. The ammonia mass distributions are depended on the flow field of fluids. In this study, the velocity field of gaseous flow is investigated to characterize the transport of ammonia in SCR catalytic filter system. The influence of different injection placements on the ammonia mass distribution is also discussed. The results show that the ammonia mass distribution is more uniform for the injector directed radially perpendicular to the main flow of inlet at the gravitational direction than that at the side wall for both laminar (Re = 640) and turbulent flows (Re = 4255). It is also found that the mixing index decreases as increasing the heating temperature in the case of ammonia injected at the side wall.

폐기물고형연료 발열량에 영향을 미치는 요인에 관한 연구 (A study on determinants having influence on heating value of waste-derived solid fuels)

  • 강민수;김양도;류영복;이강우;손병현;이만식
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.220-227
    • /
    • 2010
  • 폐기물을 이용한 고형연료의 제조는 온실가스 저감과 대체연료로써의 이윤 창출 목적으로 많은 연구가 진행되었고, 이로 인해 상용화가 이루어 질 정도로 기술적인 발전을 거듭 하였다. 하지만, 단일폐기물에 대한 고형연료의 제조는 성분 변화가 별로 없지만 여러 가지 폐기물을 혼합하여 고형연료를 만들 경우에는 주의가 필요하다. 본 연구에서는 다양한 폐기물을 이용하여 제조한 고형연료의 특성 분석을 하였다. 특성분석 결과 성형 전 폐기물과 성형 후 고형연료는 발열량 차이가 크게 나타났으며, 그 원인으로는 폐기물의 성상, 수분, 혼합정도에 기인되었다. 균일 혼합 후 폐기물 고형연료는 발열량이 6,000kcal/kg을 넘었다.

균일 열플럭스가 있는 $180^{\circ}C$ 원형단면 곡관의 선회유동 열전달특성 연구 (A study on the heat transfer characteristics of swirling flow in a circular sectioned $180^{\circ}C$bend with uniform heat flux)

  • 이상배;권기린;장태현
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.615-627
    • /
    • 1997
  • An experiment was performed to local heat transfer coefficient and Nusselt number in the circular duct of 180.deg. bend for Re=6*10$^{4}$, 8*10$^{4}$ and 1*10$^{5}$ at swirling flow and non-swirling flow conditions. The test tube with circular section was made by stainless which has curvature ratio 9.4. The wall of test tube was heated directly by electrical power to 3.51 kw and swirling motion of air was produced by a tangential inlet to the pipe axis at the 180 degree. Measurements of local wall temperatures and bulk mean temperature of air are made at four circumferential positions in the 16 stations. The wall temperatures show particularly reduced distribution curve at bend for non-swirling flow but this effect does not appear for swirling flow. Nusselt number distributions for swirling flow which was calculated from the measured wall and bulk temperatures were higher than that of non-swirling flow. Average Nusselt number of swirling flow increased about 90 ~ 100% than that of non-swirling flow whole through the test tube. The Nu/N $u_{DB}$ values at the station of 90.deg. for non-swirling flow and swirling flow are respectively about 2.5 and 4.8 at Re=6*10$^{4}$. Also that is good agreement with Said's result for non-swirling flow. flow.

다수의 균일발열부품이 접촉된 광대역 회선분배 시스템 냉각용 히트파이프 시스템의 비정상 동작특성에 관한 수치적 연구 (Numerical study on the transient operation characteristics of the heat pipe cooling system with the multiple uniform heating components for broadband digital cross-connect system)

  • 노홍구;이재헌
    • 대한기계학회논문집B
    • /
    • 제22권6호
    • /
    • pp.734-749
    • /
    • 1998
  • A numerical study t predict the characteristics on transient operation of the heat pipe cooling system with multiple heaters for electronic system has been performed. The heat pipe cooling system of 45 cm length and 16 mm diameter was composed of evaporator section with four heaters which simulate electronic components, insulated transport section, and condenser section with a conductor which was cooled under the constant heat flux boundary condition. Two test cases were investigated in present study; Case 1 indicated that the 1st and 2nd heaters among four heaters were heated off, while the 3rd and the 4th heaters were heated on. Case 2 was the inverse situation switched from heating locations of Case 1. Case 3 indicated that the 1st and 4th heaters among four heaters were heated off, while the 2nd and 3rd heaters were heated on. The results showed that the transient time to reach the steady state is shorter for Case 1 than for Case 2. Especially, the maximum temperature among the heaters which simulate electronic components during switching operation is relatively small compared to the maximum allowable operating temperature in electronic system. It is concluded that the heat pipe cooling system in present study operate with the good thermal reliability even for sudden switching situation of the heaters.