• 제목/요약/키워드: Uniform Current Distribution

검색결과 252건 처리시간 0.026초

병렬운전 모델을 이용한 병렬운전 시스템의 운전 특성 (The Operation characteristics of the parallel operation system using the model for parallel operation)

  • 김성관;김수석;김왕곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.157-163
    • /
    • 2002
  • Consideration for parallel operation in a high power system has been increased due to the advantages of parallel operation like as high productivity, simplicity of design, and redundancy of power. This paper discussed the parallel operation of DC-DC Converter, Which Can be used as a high power system, is studied. Based on the small signal model of DC-DC Converter, the simple and exact power stage model of parallel operation system is derived and the parallel operation system using current balance method for the uniform current distribution among the parallel operation system is discussed. To verify the high performance of the proposed DC-DC converter system for parallel operation, the simulation test of the parallel operation, which has 2 Converter modules, is accomplished.

  • PDF

고강도 콘크리트 휨부재의 정착 및 겹침이음길이에 관한 실험적 연구 (Experimental Research on Development and Splices Length in High-Strength Concrete Flexural Members)

  • 이기열;김우;정기오
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.865-871
    • /
    • 2003
  • This paper presents the test results of 24 beam-end specimens to investigate the effect of concrete strength and cover thickness on the development resistance capacity in tensile lap splice length regions. The results showed that as higher strength concrete was employed, nor only development resistance capacity was influenced by cover thickness, but also more sufficient safety factor reserved shorter than the lap splice length provision in current design code. From experimental research results, high-strength concrete development length was not inverse ratio of ($\sqrt{f_{ck}}$) but directly inverse of $f_{ck}$, and it is also said that there is a certain limit length of the embedded steel over which the assumption of uniform bond stress distribution is valid specially for high-strength concrete not having a same embed length such as normal-strength concrete in current design criteria hypothesis.

  • PDF

Characteistics of Charge Traps and Poling Behavior of Poly (Vinylidene Fluoride)

  • 서정원;류균상;이호성
    • Bulletin of the Korean Chemical Society
    • /
    • 제6권4호
    • /
    • pp.218-221
    • /
    • 1985
  • Transient charging and discharging currents as well as space charge limited currents have been measured in biaxially stretched poly(vinylidene fluoride) film under various poling fields and temperatures. At low temperatures and short poling times, the I-V characteristics showed shallow trap behavior. When the current values extrapolated to the infinite time, the I-V characteristics indicate that the distribution of the trap energy levels is uniform or very broad. The abnormal suppression of current at higher poling voltages and the high discharge rate observed also in the same voltage range are attributed to the morphological changes due to dipole reorientation.

재 프로그래밍 방법에 의한 MIM ANTIFUSE의 온저항 감소 효과 (On-state resistance secreasing effect of mim antifuse by re-programming method)

  • 임원택;이상기;김용주;이창효;권오경
    • 한국진공학회지
    • /
    • 제6권3호
    • /
    • pp.194-199
    • /
    • 1997
  • Al/a-Si:H/Mo 구조의 MIM(Metal-Insulator-Metal) antifuse를 제작하여 antifuse의 I-V 특서을 조사하고, 온저항의 분포를 구하였다. 제작된 antifuse의 누설전류는 1pA/$\mu\textrm{m}^2$이하였고, 프로그래밍 전압은 10~11V 내에 분포하였다. 프로그램 후 온저항은 대부분 10~20 Ω이었고, 20%정도는 100$\Omega$이상의 분포도를 보였다. 이러한 온저항 분포의 편차와 저항값을 줄이기 위해 이미 프로그램된 antifuse에 다시 전류를 주입하는 재 프로그래밍 방법을 시도 하였다. 이 방법을 통하여 100$\Omega$이상의 온저항을 가지는 antifulse를 다시 50$\Omega$이하로 낮출 수 있었다. 재 프로그래밍 방법을 사용한 antifuse는 한번만 프로그래밍 했을 때 보다 더욱 더 균일하고 낮은 온저항 분포를 가졌다.

  • PDF

알루미늄 합금의 표면경화 (Formation of Thicker Hard Alloy Layer on Surface of Aluminum Alloy by PTA Overlaying with Metal Powder)

  • Lee, Young-Ho
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1996년도 특별강연 및 추계학술발표 개요집
    • /
    • pp.3-15
    • /
    • 1996
  • The formation of a thicker hard alloyed layer have been investigated on the surface of aluminum cast alloy (AC2B) by PTA overlaying process with Cr, Cu and Ni motel powders under the condition of overlaying current 125-200A. overlaying speed 150 mm/min and different powder feeding rate 5-20 g/min. In addition the characteristics of hardening and wear resistance of alloyed layer here been examined in relation to the microstructure of alloyed layer. Main results obtained were summarized as follows: 1) There was an optimum overlaying condition to get a good alloyed layer with smooth surface. This good layer became easy to be formed as increasing overlaying current and decreasing powder feeding rate under a constant overlaying speed. 2) Cu powder was the most superior one in metal powders used due to a wide optimum overlaying condition range, uniform hardness distribution of Hv250-350, good oar resistance and freedom from cracking in alloyed layer with fine hyper-eutectic structure. 3) On the contrary, irregular hardness distribution was usually obtained in Cr ar Ni alloyed layers of which hardness was increased as Cr or Ni contents and reached to maximum hardness of about Hv400-850 at about 60wt%cr or 40wt%Ni in alloyed layer. 4) Cracking occurred in Cr or Ni alloyed layers with higher hardness than Hv250-300 at mere than 20-25wt% of Cr or Ni contents in alloyed layer. Porosity was observed in all alloyed layers but decreased by usage of spherical powder with smooth surface.

  • PDF

CFD를 통한 용융탄산염 연료전지의 유동 및 크기에 따른 운전 특성 분석 (Study on the Effects of the Flow Characteristics and Size on the Peformance of Molten Carbonate Fuel Cells Using CFD)

  • 김동우;김하영;최정환;이창환
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.147-154
    • /
    • 2019
  • In this study, effects of flow types and size of molten carbonate fuel cells (MCFCs) were investigated using CFD simulation. In the simulation, the current collector of MCFCs were assumed to be an porous media. With the area of $0.09m^2$, the effect of flow types such as Co-flow, Counter-flow, Cross-flow were studied. After that the effect of the size and flow direction was studied. Among three-flow types, MCFCs with co-flow type shows more uniform distribution and current density distribution.

한국인의 체내 비소오염도 조사 연구 (Distribution of Arsenic in Korean Human Tissues)

  • 이상기;양자열;김기욱;이수연;권태정;유영찬
    • Environmental Analysis Health and Toxicology
    • /
    • 제18권2호
    • /
    • pp.101-109
    • /
    • 2003
  • Humans are exposed to toxic element arsenic (As) from air, food and water The current study was performed to investigate the levels of arsenic in the internal organs (liver, kidney cortex, lung, cerebrum. abdominal muscle and abdominal skin) and to find out correlation with age and interrelationship between tissues in Korean human bodies who had lived in Seoul or Gyeonggi Province and Honam district. The tissues from 43 Korean cadavers were digested with microwave digestion system and arsenic was determined by inductively coupled plasma mass spectrometer (ICP-MS). The mean recovery percentages of arsenic In liver were about 80% and artenic concentrations in human tissues were almost uniform. The mean level of arsenic in internal tissues were at follow ; liver 44.556${\pm}$25.199 ppb, kidney cortex 42.652${\pm}$22.082 pub, lung 31.020 ${\pm}$ 17.504 ppb. cerebrum 35.703 ${\pm}$22.191 ppb, muscle 43.413${\pm}$26.619 ppb and skin 42.106${\pm}$25.8,11 ppb. No significant difference was found in the levels of arsenic between sexes. Meanwhile significant differences between districts where they had lived were found in all tissues tested. The levels of arsenic in the tissues of cadavers who had lived in Seoul Gyeonggi Province were higher than those of Honam district. In addition a positive correlation between As concentration and age was observed only in the cerebrum (p < 0.05). A significantly high correlations between tissues were observed in all tissues tested. This result also shows that the distribution of arsenic is uniform in internal tissues.

분포정수를 갖는 전기회로에 대한 최대원리의 응용 (An Application of the Maximum Principle to Distributive Electrical Circuits)

  • 양흥석
    • 전기의세계
    • /
    • 제18권6호
    • /
    • pp.9-22
    • /
    • 1969
  • This thesis has suggested a method of applying the Maximum Principle of Pontryagin to the optimal control of distributive electrical networks. In general, electrical networks consist of branches, nodes, sources and loads. The effective values of steady state currents and voltages are independent of time but only expressed as the functions of position. Moreover, most of the node voltages and branch currents are not predetermined, that is, initially unknown, and their inherent loop characteristics satisfy only Kirchhoff's current and voltage laws. The Maximum Principle, however, needs the initial fixed values of all state variables for its standand way of application. In spite of this inconsistency this thesis has undertaken to suggest a new approach to the successful solution of the above mentioned networks by introducing scaling factors and a state variable change technique which transform the boundary-value unknown problem into the boundary-value partially fixed and partially free problem. For the examples of applying the method suggested, the control problems for minimizing copper quantity in a distribution line have been solved with voltage drop constraint imposed on. In the case of uniform load distribution it has been shown that the optimal wire diameter of the distribution line is reciprocally proportional to the root of distance. For the same load pattern as above the wire diameter giving the minimum copper loss in the distribution line has been shown to be reciprocally proportional to distance.

  • PDF

Thermoelastic static and vibrational behaviors of nanocomposite thick cylinders reinforced with graphene

  • Moradi-Dastjerdi, Rasool;Behdinan, Kamran
    • Steel and Composite Structures
    • /
    • 제31권5호
    • /
    • pp.529-539
    • /
    • 2019
  • Current paper deals with thermoelastic static and free vibrational behaviors of axisymmetric thick cylinders reinforced with functionally graded (FG) randomly oriented graphene subjected to internal pressure and thermal gradient loads. The heat transfer and mechanical analyses of randomly oriented graphene-reinforced nanocomposite (GRNC) cylinders are facilitated by developing a weak form mesh-free method based on moving least squares (MLS) shape functions. Furthermore, in order to estimate the material properties of GRNC with temperature dependent components, a modified Halpin-Tsai model incorporated with two efficiency parameters is utilized. It is assumed that the distributions of graphene nano-sheets are uniform and FG along the radial direction of nanocomposite cylinders. By comparing with the exact result, the accuracy of the developed method is verified. Also, the convergence of the method is successfully confirmed. Then we investigated the effects of graphene distribution and volume fraction as well as thermo-mechanical boundary conditions on the temperature distribution, static response and natural frequency of the considered FG-GRNC thick cylinders. The results disclosed that graphene distribution has significant effects on the temperature and hoop stress distributions of FG-GRNC cylinders. However, the volume fraction of graphene has stronger effect on the natural frequencies of the considered thick cylinders than its distribution.

In-Situ 분석법에 의한 연료전지 특성 연구 (PEMFC Characterization Study by in-situ Analysis Method)

  • 김영민;이종현;임세준;안병기;임태원
    • 한국수소및신에너지학회논문집
    • /
    • 제20권3호
    • /
    • pp.208-215
    • /
    • 2009
  • PEMFC stack power output is needed to be around 100 kW to meet the requirements of automotive application and scaling-up the active area of the stack cells will allow a higher power. In the case of scaling-up the active area of cells, it is difficult to obtain uniform in-plane internal conditions such as temperature, relative humidity and stoichiometry of the feed gas. These ununiformity with the location in the cell would affect both the performance and durability of the stack, so it is important to understand phenomena in the cell for improving them. In this study, the current density, electrochemical resistance and performance distribution measurement was performed to understand the ununiformity in a single cell using in-situ method; (1) Current Density Distribution (CDD) Device and (2) Segmented Cell Fixture. The influence of location of feed gas on the performance of a single cell was experimentally measured and discussed by using a segmented single cell which was composed of 8 compartments. The correlation between the location and performance in a single cell was discussed by these two tools and it was extended between the local characterization and the durability in a MEA by comparing the used cell with a fresh one. It was also studied in terms of electrochemistry by Electrochemical Impedance Spectroscopy.