• Title/Summary/Keyword: Underwater discharge

Search Result 54, Processing Time 0.03 seconds

Disinfection of Escherichia coli and Bacillus subtilis using underwater plasma

  • Yu, Seung-Min;No, Tae-Hyeop;Seok, Dong-Chan;Yu, Seung-Ryeol;Hong, Yong-Cheol;Lee, Bong-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.47-47
    • /
    • 2010
  • Discharge under the water is very hard and demand considerable high voltage. But specially improved electrode can generate plasma discharge to salty water with relatively low voltage. A round shape ceramic electrode having many pinholes combined with metallic one can generate plasma. 400 volt, 10 kHz and 3 micro second pulse width were applied to repeatedly running synthetic seawater with 10 L/m velocity, containing cultivated E. coli and Bacillus. As a result, 18, 94, 99.97, 100, 100 % disinfection rates to E. coli and 17.1, 17.1, 82.9, 99.4, 99.9 % disinfection rates to Bacillus subtilis were achieved to 1, 2, 3, 4, 5 times repetitive treatment respectively. In the plasma condition, the ions and electrons are separated and new kinds of components are re-synthesized by the intensive movement of the components. Especially chlorine ions are separated and recombined to residual free chlorine like HOCl, $OCl^-$. The residual free chlorine concentrations of discharged water were 0.25, 0.88, 1.39, 1.59, 1.66 mg $Cl_2$/L after 5 times treatment respectively. Another unconfirmed radical and oxidants for example, OH, $H_2O_2$, and $O_3$ can have an effect on microorganism of course.

  • PDF

Optimal Design of Submarine Pipeline for Intake and Discharge of Seawater Desalination Facilities (해수 담수화 설비의 취수 및 배출수 해저 배관 최적화 설계)

  • Choi, Gwangmin;Han, Inseop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.599-609
    • /
    • 2017
  • Desalination plants have been recently constructed in many parts of the world due to water scarcity caused by population growth, industrialization and climate change. Most seawater desalination plants are designed with a submarine pipeline for intake and discharge. Submarine pipelines are installed directly on the bottom of the water body if the bottom is sandy and flat. Intake is located on a low-energy shoreline with minimal exposure to beach erosion, heavy storms, typhoons, tsunamis, or strong underwater currents. Typically, HDPE (High Density Polyethylene) pipes are used in such a configuration. Submarine pipelines cause many problems when they are not properly designed; HDPE pipelines can be floated or exposed to strong currents and wind or tidal action. This study examines the optimal design method for the trench depth of pipeline, analysis of on-bottom stability and dilution of the concentrate based on the desalination plant conducted at the Pacific coast of Peru, Chilca. As a result of this study, the submarine pipeline should be trenched at least below 1.8 m. The same direction of pipeline with the main wind is a key factor to achieve economic stability. The concentrate should be discharged as much as high position to yield high dilution rate.

Discharge Characteristics near the tip of needle in water (수중에서 침전극 끝단의 방전특성)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Park, Geon-Hun;Jun, Byung-Wook;Kim, Hoe-Gu;Beak, Young-Hwan;Lee, Kyu-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.239-241
    • /
    • 2007
  • In this paper we describe streamer propagations characterizing underwater pre-breakdown and breakdown behaviour under impulse voltages. Streamer corona branches in lower resistivities are much thicker and brighter than those in higher resistivities. The negative streamer channels not only have more branches but also widely spread out than the positive streamer channels. The succession of streamer coronas during re-breakdown produces a stepwise propagation. The pre-breakdown currents consist of the conduction current and streamer corona current pulses.

  • PDF

Numerical analysis of borehole expansion induced by PDT in sandy soils (펄스 방전에 의한 사질토지반 시추공 확공에 대한 수치해석)

  • Park, Hyun-Ku;Lee, Seung-Rae;Kim, Tae-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.260-266
    • /
    • 2010
  • 본 연구에서는 사질토 지반에서 펄스 방전(PDT)에 의한 확공 현상을 평가하기 위한 수치해석 연구를 수행하였다. 수중 폭발 모델을 기반으로 PDT적용을 통해 시추공 내부의 시멘트 페이스트에 발생하는 충격파를 모델링하였고, 이를 바탕으로 사질토 지반에 유발되는 변형을 유체-구조물 연동해석을 통해 예측하였다. 해석 결과, 수치해석을 통한 예측이 문헌에 언급된 지반 확공 정도에 대한 실험 결과와 부합하는 것으로 나타났다. 또한 펄스 방전에 의해 지반의 응력 증가 및 체적 압축 등의 지반 다짐효과를 파악할 수 있었다.

  • PDF

A Study on Directivity of Optical Fiber Sensor Using the Sagnac Interferometer in Underwater (수중에서 Sagnac 간섭계를 이용한 광섬유 센서의 지향성에 관한 연구)

  • Shin, Dae-Yong;Kwon, Ki-Tae;Lee, Jong-Kil;Lee, June-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1714-1716
    • /
    • 2002
  • Optical fiber sensor is a subject which has been attracted considerable attention in recent year. Especially, it is being developed for the detection and location of partial discharge in oil-filled transformers. In this paper, we propose and experimentally demonstrate directivity and sensitivity of a hollow cylindrical mandrel sensor. The sound source is a PZT actuator of hollow cylinder type. Several layers of the fiber laminated around the mandrel surface and experiments were performed on three axis modes. The experimental results can be applied to analyze detected signals optimally.

  • PDF

The development of basic structure of jellyfish separator system for a trawl net (트롤어구용 해파리 분리 배출장치 기본 구조 개발)

  • Kim, In-Ok;An, Heui-Chun;Shin, Jong-Keun;Cha, Bong-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.2
    • /
    • pp.99-111
    • /
    • 2008
  • The purpose of this study is to develop the jellyfish separator system(JSS) for reducing fishery damage by the increase of jellyfish in the sea area of Korea in summer. First of all, to find the optimum structure of a JSS, six types of JSS in trawl fishery were designed and manufactured, the underwater shape of JSS and the separating process by JSS were observed in the circulating water channel(CWC). And the field experiments were carried out in July and September 2004 in the southern sea of Korea. For the moving path of the jellyfish model in the CWC, in case that the model was larger than the mesh size of the separator net, it was guided toward the lower part of the separator net by the guiding net and discharged through the outlet. In case that the model was smaller than the mesh size of the separator net, some models which passed through the upper part of the guiding net were smaller than the mesh size of the guiding net and discharged through the outlet and most of the model which passed through the lower part of the guiding net moved to the codend passing through the separator net. According to the field experiment result, the optimum tilt angle of separator net was inferred $20^{\circ}$ that the discharge rate of jellyfish was higher than the other tilt angle of separator net and the optimum structure of JSS was inferred GS type(consists of guiding net and separator net) that the discharge rate of jellyfish was higher than S type(consists of separator net). It was demamded to carry out more study for the countermeasure to reduce loss of fish.

A Study on Taehwa River Red Tide Solution through Stream Flow (유수소통을 통한 태화강 적조해결 방안 연구)

  • Cho, Hong-Je;Yoon, Sung-Kyu
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.363-375
    • /
    • 2011
  • Recently, Water quiality of urban river largely have gotten better by virtue of sewer pipe laying and sewage treatment plants construction. or the various contaminants which is flowed in into river have generated underwater ecosystem disturbance and red tide by lack of sewage and waste water disposal facilities. With tidal river, taehwa river of ulsan metropolitan city has large river width and gradual stream bed gradient at the dry and storage period. Moreover, the flow is paralyzed due to the bridge pier protection work, consist of the mat foundation which is about 1.2km from two bridge and the contaminant is accumulated. it is caused by of the red tide generated from the several years or it activates. In this study, When flow area is largest by changing independent footing of bridge pier of two bridges and using RMA2 model, we hydraulically analyzed a variable breadth of velocity and discharge. Consequently, flow rate increased the maximum 103%, discharge was exposed to increase the maximum 61%. Directly this cannot extinguish the red tide but suppresses the red tide occurrence or can reduce. And it is determined to prevent the depositioning of the contaminant and can control fundamentally the red tide occurrence cause.

Experimental Study on the Performance Characteristic in Underwater Harvest-Type Ice Storage System (수중 빙제조형 빙축열시스템의 성능특성 특성)

  • Jang, Yong-Sik;Lee, Ho-Saeng;Choi, In-Su;Kim, Jae-Dol;Kim, Eun-Pil;Yoon, Jung-In
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.298-303
    • /
    • 2001
  • A fundamental study on the under water harvest-type ice storage system and its temperature characteristics in ice storage system was performed experimentally. The experiments were conducted by changing the inlet refrigerant temperature of an evaporator to analyzing the thermal fluid motion inside the ice storage tank. From the experimental results, the cold storage characteristics were investigated by measuring the axial and radial temperature variations inside the ice storage tank with respect to the inlet and outlet refrigerant temperatures of an evaporator. In case of the under water harvest-type ice storage system, thermal fluid. motion inside the ice storage tank was shown differently in comparison with that of other ice storage systems. During the cooling storage process, there was no supercooling phenomenon in the ice storage tank. These results show the characteristic of this system and the possibility of application to other fields.

  • PDF

Sedimentologic Linkage of depositional environments of Han River and Kyunggi Bay, Korea (한강 유역과 경기만 퇴적환경의 연계성)

  • 오재경;방기영
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.3
    • /
    • pp.225-236
    • /
    • 2003
  • In order to understand the relationship of depositional environment between fluvial and estuarine-embayment in Han River system, including depositional change in main Han River, more than 250 bottom sediment and 70 suspended sediment were analyzed with hydrologic data. Based on the previous data, the study area can be divided into two environment(fluvial and estuarine-embayment) by Singok underwater dam. The gravelly facies occurs in the South and North Han Rivers and sandy and silty facies occupies in the main Han River. Depositional environment of main Han River changed mainly because of limited sediment transport and hydrological condition. In the estuarine-embayment environment, coarse-grained sediments are dominant in tidal channel and of shore whereas fine and poorly sorted sediments are observed in coastal area. During moderate period, relationship between fluvial-estuarine-embayment system is discontinuou s because of flow restriction by artificial construction such as dam and underwater dam, so that each river system characterizes the individual environment. Fluvial and estuarine system is influenced by tide and, thus, transition zone of estuarine- embayment system moves landward. During flooding period, however, each river system is integrated as continuous depositional system by high discharge and, thus, transition zone of fluvial-estuarine-embayment system moves seaward. For further detailed systems about the lower Singok under-water dam, joint research of South-North Korea should be necessary.

Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures (오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구)

  • Park, Sun Hwan;Chang, Yoon Young;Jeong, Jeong Ho;Son, Jeong Ho;Park, Seok Hyo
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.2
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.