• Title/Summary/Keyword: Underground structure

Search Result 999, Processing Time 0.024 seconds

Overview of Earth Retaining Structures on Underground Excavations (굴착공법의 문제점과 개선방안)

  • 이종규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.55-64
    • /
    • 2002
  • This paper presents a brief review of flexible retaining structure and the most significant methods developed to predict their behavior on underground excavations. Some observations are made about the future directions that the design of retaining systems may take , as there are still some problems where uncertainity exists, in soil-structure interaction and evaluation of strength parameters etc. And also reviewed papers presented in 2002 Fall National Conference of KGS.

  • PDF

Study on bearing characteristic of rock mass with different structures: Physical modeling

  • Zhao, Zhenlong;Jing, Hongwen;Shi, Xinshuai;Yang, Lijun;Yin, Qian;Gao, Yuan
    • Geomechanics and Engineering
    • /
    • v.25 no.3
    • /
    • pp.179-194
    • /
    • 2021
  • In this paper, to study the stability of surrounding rock during roadway excavation in different rock mass structures, the physical model test for roadway excavation process in three types of intact rock mass, layered rock mass and massive rock mass were carried out by using the self-developed two-dimensional simulation testing system of complex underground engineering. Firstly, based on the engineering background of a deep mine in eastern China, the similar materials of the most appropriate ratio in line with the similarity theory were tested, compared and determined. Then, the physical models of four different schemes with 1000 mm (height) × 1000 mm (length) × 250 mm (width) were constructed. Finally, the roadway excavation was carried out after applying boundary conditions to the physical model by the simulation testing system. The results indicate that the supporting effect of rockbolts has a great influence on the shallow surrounding rock, and the rock mass structure can affect the overall stability of the surrounding rock. Furthermore, the failure mechanism and bearing capacity of surrounding rock were further discussed from the comparison of stress evolution characteristics, distribution of stress arch, and failure modes in different schemes.

In-situ Rock Stress Measurement at the Water Tunnel Sites in the OO Oil Storage Facility with Hydraulic Fracturing Method (수압파쇄법을 이용한 OO 원유비축시설 내 수벽 터널에서의 초기응력 측정)

  • Bae, Seong-Ho;Kim, Jae-Min;Kim, Jang-Soon;Lee, Young-Ho
    • Tunnel and Underground Space
    • /
    • v.18 no.1
    • /
    • pp.80-89
    • /
    • 2008
  • The influence of in-situ rock stress on the stability of an underground rock structure increases as the construction depth become deeper and the scale of a rock structure become larger. In general, hydraulic fracturing stress measurement has been performed in the surface boreholes of the target area at the design stage of an underground structure. However, for some areas where the high horizontal stresses were observed or where the overstressed conditions caused by topographical and geological factors are expected, it is desirable to conduct additional in-situ stress measurement in the underground construction site to obtain more detailed stress information for ensuring the stability of a rock structure and the propriety of current design. The study area was a construction site for the additional underground oil storage facility located in the south-east part of OO city, Jeollanam-do. Previous detailed site investigation prior to the design of underground structures revealed that the excessive horizontal stress field with the horizontal stress ratio(K) greater than 3.0 was observed in the construction area. In this study, a total of 13 hydraulic fracturing stress measurements was conducted in two boreholes drill from the two water tunnel sites in the study area. The investigation zone was from 180 m to 300 m in depth from the surface and all of the fracture tracing works were carried out by acoustic televiewer scanning. For some testing intervals at more than 200 m ind depth from surface, the high horizontal stress components the horizontal stress ratio(K) greater than 2.50 were observed. And the overall investigation results showed a good agreement with the previously performed test.

An Experimental Study on the Thermal Performance by the Type of Thermal Insulation in Basement Structures (지하외벽체의 단열유형별 열성능에 관한 실험적 연구)

  • Lee, J.Y.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.73-80
    • /
    • 2002
  • This is study of the planning of thermal insulation to prevent heat loss in a basement, is aimed at investigating the heat loss from the basement space and basement structures. The results analyzed in these researches are as follows; To analyze the heat loss from basement structures, this study experimented on the heat flow phenomenon of a non-insulation structure and two insulation structure models. From the result, the interior surface temperature of two insulation structures(B, C, model) showed an equal temperature, but the interior surface temperature of a non-insulation structure (A model) is different from the two models, Therefore, we understand that the insulator constructed in the basement structure makes a role of preventing the heat loss from the basement. In addition, the exterior surface temperature of two insulation structure models showed an equal temperature. Specially, judging from the temperature difference of C model. we understand that the performance of insulator is low under the definite depth of underground. The thermal insulation design should be constructed under the definite depth of underground considering outdoor and building conditions.

A Case Study on Reinforcement of Ground and Foundation against Subsidence in Abandoned Mining Area (폐광지역 침하방지를 위한 지반 및 구조물기초 보강)

  • Kim, Do-Hyung;Choi, Chang-Rim;Kim, Dong-Hyun;Lee, Du-Hwa;Lee, Baek-Song;Je, Hae-Chan
    • Tunnel and Underground Space
    • /
    • v.17 no.4
    • /
    • pp.255-265
    • /
    • 2007
  • As the mechanism and effect range of subsidence are altered according to the various conditions (the ground condition, the earth pressure, the geometric condition of underground cavity and the structure load), the analysis and prediction of subsidence in abandoned mining area are very difficult. Also, as the geological characteristics and the mining methods are differed in each mines, the application of the pre-existing reinforcements without improvement has a lot of difficulties and limits. In this study, the various underground investigation such as long-depth core drilling, seismic tomography and BIPS (borehole image processing system) were performed, the distribution of underground cavity and coal seam and rock relaxation condition were analyzed. And we predicted the type of subsidence and estimated the subsidence by theories of mining subsidence. With these results, we analyzed the mechanism of subsidence occurrence in the research object area. Finally, we improved existing methods which were applied to the abandoned mining area and also we established the rational reinforcement for the ground and structure foundation against each subsidence cause.

Humidity Change Rate Analysis for Various Waterproofing Method in Underground Structures During Winter Season (지하 구조물 동절기 온도조건에서의 방수공법별 습도 변화량 분석)

  • An, Ki-Won;Lee, Yeon-Sil;Lee, Jung-Hoon;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.118-125
    • /
    • 2016
  • This paper proposes the appropriate waterproofing methods for underground structures after applying different types of waterproofing materials on the concrete test specimens and selecting the best results out of humidity testing in winter conditions. Results of the testing showed that the underground structures absolutely require relevant waterproofing application based on the environmental conditions; when applied with interior waterproofing, the results showed that the concrete maintained high level of humidity and reinforcing steel within the concrete layer corroded. However, when applied with exterior waterproofing, it was shown that the waterproofing layer prevent direct contact with water and concrete, thereby protecting the concrete structure and improving overall durability. It follows that during underground structure construction, exterior waterproofing methods are have shown by an effective method for improving the durability as well as providing a comfortable interior environment for users.

Experimental study on the tunnel behavior induced by the excavation and the structure construction above existing tunnel (기존터널 상부지반 굴착 후 구조물 설치에 따른 터널거동에 관한 실험적 연구)

  • Cha, Seok-Kyu;Lee, Sangduk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.640-655
    • /
    • 2018
  • Recently, the construction of the urban area has been rapidly increasing, and the excavation work of the ground has been frequently performed at the upper part of the existing underground structures. Especially, when the structure is constructed after the excavation of the ground, the loading and unloading process in the ground under the excavation basement can affect the existing underground structures. Therefore, in order to maintain the stability of the existing underground structure due to the excavation of the ground, it is necessary to accurately grasp the influence of the excavation and the structure load in the adjoining part. In this study, the effect of the excavation of the ground and the new structure load on the existing tunnel was experimentally implemented and the influence of the adjacent construction on the existing tunnel was investigated. For this purpose a large testing model with 1/5 scale of the actual size was manufactured. The influence of ground excavation, width of the load due to new structure, and distance between centers of tunnel and of excavation on the existing tunnel was investigated. In this study, it was confirmed that the influence on the existing tunnel gets larger, as the excavation depth get deeper. At the same distance, it was confirmed that the tunnel displacement increased up to three times according to the increase of the building load width. That is, the load width influences the existing tunnel larger than the excavation depth. As the impact of the distance between centers of tunnel and of excavation, it was confirmed that tunnel crown displacement decreased by 48%. The result showed that a tunnel is located in the range of 1D (D: tunnel diameter) from the center of excavation, the effect of excavation is the largest.

Exploration of underground utilities using method predicting an anomaly(II) - field application (전기비저항을 이용한 지하매설물 탐사(II) - 현장실험 중심으로)

  • Ryu, Hee Hwan;Cho, Seon Ah;Kim, Kyoung Yul;Cho, Gye Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.449-461
    • /
    • 2017
  • The uncertain existence and insufficient information of underground structures, such as pipe lines and cable tunnels, is causing many problems related to route plan, design, construction of new underground structures. The theoretical equations that is able to predict the location, size, and direction of underground structures through electric field analysis are suggested at the previous study (Ryu., 2015). Three field tests were performed for predicting the location, size, and direction of underground structures and the existence and size of sink-hole. Prediction results were reflected at the design and follow-up measures were performed.

A Study on the Stability of Underground Structure considering the Orientation and the Stiffness of Discontinuity (불연속면의 경사와 강성을 고려한 지하구조물 안정성에 관한 연구)

  • Lee, Seung-Ho
    • Tunnel and Underground Space
    • /
    • v.7 no.1
    • /
    • pp.65-74
    • /
    • 1997
  • Underground structures show different behaviors depending upon the space and the mechanical characteristics of discontinuities, such as joints, beddings, faults and shear zone. Desingning the rock structeres without considering the significance of these discontinuities can lead to false conclusions. This paper includes study on the following topics; the numerical analysis of continuous rock and discontinuous rock around a tunnel, the influences on shotcrete moment and rock-bolt axial force of tunnel due to different joint orientation and stiffness.

  • PDF

A Study on Improving the Data Quality Validation of Underground Facilities(Structure-type) (지하시설물(구조물형) 데이터 품질검증방법 개선방안 연구)

  • Bae, Sang-Keun;Kim, Sang-Min;Yoo, Eun-Jin;Im, Keo-Bae
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.2
    • /
    • pp.5-20
    • /
    • 2021
  • With the available national spatial information that started from the sinkholes that occurred nationwide in 2014 and integrated 15 areas of underground information, the Underground Spatial Integrated Map has been continuously maintained since 2015. However, until recently, as disasters and accidents in underground spaces such as hot water pipes rupture, cable tunnel fires, and ground subsidence continue to occur, there is an increasing demand for quality improvement of underground information. Thus, this paper attempted to prepare a plan to improve the quality of the Underground Spatial Integrated Map data. In particular, among the 15 types of underground information managed through the Underground Spatial Integrated Map, quality validation improvement measures were proposed for underground facility (structure-type) data, which has the highest proportion of new constructions. To improve the current inspection methods that primarily rely on visual inspection, we elaborate on and subdivide the current quality inspection standards. Specifically, we present an approach for software-based automated inspection of databases, including graphics and attribute information, by adding three quality inspection items, namely, quality inspection methods, rules, and flow diagram, solvable error types, to the current four quality inspection items consisting of quality elements, sub-elements, detailed sub-elements, and quality inspection standards.