• 제목/요약/키워드: Underground pipeline

검색결과 160건 처리시간 0.041초

천연가스 공급배관의 사용적합성 통합프로그램 (Integrated Fitness-for-service Program for Natural Gas Transmission Pipeline)

  • 김우식;김영표;김철만;백종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.269-274
    • /
    • 2008
  • For fitness-for-service analyses of underground natural gas pipelines, engineering assessment methods against possible defects need to be developed. The assessment methods for high pressure pipeline of KOGAS, was developed using the full size pipe burst tests and the finite element analysis. It included the defect assessment methods for a single and multi-corrosion, corrosion in girth welding part, corrosion in seam welding part, the mechanical damage defects as dent and gouge, crack and large plastic deformation of API 5L X65 pipe. In addition, we developed method to assess pipeline integrity by internal and external load to buried pipeline. Evaluation results were compared with other methods currently being applied to the gas pipeline. The program of Windows environment is made for easily using assessment methods. It provides a consistent user interface, so non-professional technician can easily and friendly use the FFS program from company intranet. Several evaluation programs is easily installed using one installer. Each program constitutes a common input interface and the output configuration program, and evaluation result store and can be recalled at any time. The FFS program based on independent evaluation method is used to evaluate the integrity and safety of KOGAS pipeline, and greatly contribute to safe and efficient operation of pipeline. This paper presents experimental, analytical and numerical investigations to develop the FFS methods for KOGAS pipeline, used as high pressure natural gas transmission pipeline within KOREA. Also, it includes the description of the integrated program for FFS methods.

  • PDF

기존 대구경 파이프라인과 신설터널간의 상호작용 (Interactions between pre-existing large pipelines and a new tunnel)

  • 정선아;최정인;홍은수;천윤철;이석원
    • 한국터널지하공간학회 논문집
    • /
    • 제11권2호
    • /
    • pp.175-188
    • /
    • 2009
  • 도심지 등 지역적인 여전에 의하여 기존의 지하 공동 또는 터널에 근접하여 발파를 이용한 새로운 터널을 굴착할 경우, 새로운 터널의 굴착으로 인하여 지반이 이완되고 따라서 기존 지하 공동의 안정성에 문제가 발생할 수 있다. 이러한 가존 지하 공동의 안정성에 문제를 발생시킬 수 있는 가장 큰 요소로는 기존 지하 공동과 신설 터널의 이격거리가 될 수 또한 신설 터널 굴착으로 인한 소성영역의 발생에 따른 지반 이완을 문제 심을 수 있다. 따라서 본 연구에서는 기존 광역 상수관과 신설 터널의 이격거리에 따른 기존 광역 상수관의 안정성을 평가하기 위하여 이격거라가 다른 여섯 가지 모델에 대해 석고를 이용힌 2차원 축소 모형실험을 실시하였다. 실험 결과는 터널 굴착과정과 파괴 단계에서 발생된 변위 벡터와 균열양상으로 표현하였다. 터널 굴착과정 중 발생하는 변위를 분석하면, 터널과 광역 상수관의 간격이 상수관 직경의 2.5배 (2.5D)까지는 이격거리가 증가함에 따라 감소하는 경향을 보인다. 그러나 중심 간격이 2.5D를 넘으면 추가변위는 발생하지 않았다.

송전선로 철탑기초의 접지저항 해석 (Analysis of the Earth Resistance for the Tower Footing of T/L)

  • 이현구;하태현;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.344-346
    • /
    • 2001
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. During a fault on any of the transmission lines, energization of the earth by supporting structures near the fault can result in large voltages appearing locally between the earth and the steel wall of any nearby pipeline. This paper presents the outline of the tower footings for the transmission lines having been used in KEPCO and analyzes the earth resistance for operation method of the tower footing, that is contact presence for the anchor and reinforcing rob of the tower and foundation presence of the underground wiring.

  • PDF

철탑과 매설배관의 이격거리 관련 기준 (Standards of Separation Distance between Tower and Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.53-55
    • /
    • 2005
  • Because of the continuous growth of energy consumption and also the tendency to site power lines and pipelines along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. The lightning strokes collected by an electric substation or power line tower might cause arcing through the soil to an adjacent gas pipeline. This paper gives the review of the breakdown mechanism and the standards of separation distance between lower and pipelines.

  • PDF

전철 누설전류가 지하매설 배관엘 미치는 영향 해석 (Analysis of DC Traction Stray Current Influences on Buried Pipelines)

  • 이현구;하태현;배정효;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1273-1275
    • /
    • 2003
  • Corrosion of metallic structures arises when an electric current flows from the metal into the electrolyte such as soil and water. The potential difference across the metal-electrolyte interface, the driving force for the corrosion current, can emerge due to a variety of temperature, pH, humidity etc.. In this paper we analyze P/S potential and axial current of the pipeline with CP systems using BEM and DC traction stray current influences on buried pipelines.

  • PDF

대지진에 의한 지하구조물 부상과 지질학적 특성의 상관성 연구 (Study on Correlation between Large Earthquake-Induced Underground Structure Uplift and Geological Settings)

  • 강기천;김지성
    • 한국지반신소재학회논문집
    • /
    • 제15권4호
    • /
    • pp.9-16
    • /
    • 2016
  • 2004년 일본의 니가타켄 츄에츠 지방의 나가오카, 오지야시에서 1,450개 이상의 지하구조물이 1.5m까지 부상하였다. 융기손상은 Lifeline 시스템의 일부인 하수 시스템의 흐름뿐만 아니라 교통흐름을 방해로 인해 심각한 문제를 야기 시킨다. 복구작업의 경우 손상된 하수 시스템의 오픈 컷 조사는 나가오카시 정부에 의해 수행되었다. 지진으로 인한 매설된 파이프 라인의 손상에 대한 중요한 데이터는 조사결과로부터 수집하였다. 본 연구는 지하 구조물의 부상량에 영향을 미치는 요인을 SPT 시추공 logs를 통해 손상된 지역의 위치와 파이프라인의 경사를 포함하는 데이터를 사용하여 조사하였다. 지하구조물의 부상과 영향을 받는 지역의 지질학적 특성 사이의 상관관계 분석을 통해 부상현상의 주요변수는 지하수의 깊이, 원지반에서의 점토층 두께, SPT N값인 것으로 밝혔다.

토립자 유실을 고려한 로지스틱 회귀분석 및 GIS 기반 도시 지반함몰 취약성 평가 (Logistic Regression and GIS based Urban Ground Sink Susceptibility Assessment Considering Soil Particle Loss)

  • 서장원;류동우;염병우
    • 터널과지하공간
    • /
    • 제30권2호
    • /
    • pp.149-163
    • /
    • 2020
  • 본 연구에서는 지리정보시스템 환경에서 지하매설물 정보를 이용하여 토립자 유실을 고려한 도시 지반 함몰 취약성을 평가하였다. 지하 환경에서 물의 흐름이나 지하수위 변화에 의한 토립자 유실은 지하공동의 발생과 확장을 유도하고, 이는 지반함몰 발생에 직접적인 원인이 된다. 토립자 유실은 지하 환경에 따라 그 정도가 달라질 수 있기 때문에 본 연구에서는 지하매설물 2종(상수도 관망, 하수관로)과 지하철 선로 권역별로 지반함몰에 영향을 주는 인자를 각각 4개씩 선정하였다. 로지스틱 회귀분석 기법을 이용하여 지하매설물 및 지하철 선로 권역 별로 지반함몰 이력과 영향인자 간의 상관성을 분석하고 회귀식을 도출하였으며, 이를 토대로 3개의 지반함몰 취약성 지도를 작성하였다. 본 연구 결과는 도시 지반함몰 위험 예·경보 시스템 구축을 위한 지반함몰 고위험지역 및 지반 안전 상시 모니터링 지역 선정 근거에 대한 기초 자료를 제공할 수 있을 것으로 기대한다.

가스 배관의 차단 주파수에 따른 음파전달특성 연구 (Acoustic Wave Propagation Characteristics Corresponding to the Cut-off Frequency in Gas Pipeline)

  • 김민수;이상권;장상엽;고재필
    • 한국소음진동공학회논문집
    • /
    • 제18권7호
    • /
    • pp.693-700
    • /
    • 2008
  • High-Pressure gas Pipeline which is buried in underground has the Possibility that will be exposed to unexpected dangerous impact of construction equipment. To protect from this kind of danger, the real-time health monitoring system of the high-pressure gas pipeline is necessary. First of all, to make the real-time health monitoring system clearly, the acoustic wave propagation characteristics which are made from various construction equipment impacts must be identified. In link of technical development that prevents the damage of high-pressure gas pipeline, this paper gives FEM(finite element method) and BEM(boundary element method) solutions to identify the acoustic wave propagation characteristic of the various impact input signals which consist of Direc delta function and convolution signal of 45 Hz square signal and random signal.

자기 누설 신호와 SQI를 이용한 배관 결함 검출 (Pipeline Defects Detection Using MFL Signals and Self Quotient Image)

  • 김민호;노용우;최두현
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.311-316
    • /
    • 2010
  • 본 논문에서는 비파괴검사법 중 하나인 자기누설탐상검사법을 이용하여 지하에 매설된 가스 배관의 결함 위치를 검출하는 방법을 제안한다. 자기 누설 탐상 시스템을 통해 얻은 자기 누설 신호는 일반적으로 비선형성을 띄며 다양한 외부 요인으로 인한 신호의 왜곡이 심하다. 본 논문에서는 신호의 비선형성과 신호의 왜곡을 보정하는 신호 처리 기법 중 SQI(self quotient image)를 이용하여 배관 결함의 위치를 검출하였다. 실제로 제작된 모의시험 배관에 제작된 다양한 인공 결함에 대해 알고리즘을 적용한 결과 기존 DCT(discrete cosine transform) 계수 기반 방법에 비해 결함 검출 성능이 크게 향상됨을 확인하였다.

지중전력케이블에서 고장발생시 인근 가스배관에 유도되는 전압 해석 (Analysis of Induced Voltage on the Gas Pipeline at the Fault in a Underground Power Cables)

  • 배정효;김대경;김기준
    • 한국가스학회지
    • /
    • 제4권3호
    • /
    • pp.26-32
    • /
    • 2000
  • 최근 국내에서는 효율적인 공간활용을 위해 해저터널을 이용하여 전력을 공급하는 것이 시도되고 있으며, 해저터널내에 에너지 공급 기간시설물(전력케이블, 가스배관, 송유관, 지역난방배관 등)들이 같이 포설될 수 있으면 공사비 절감의 효과는 엄청날 것이므로 관심도가 높아지고 있다. 따라서 본 논문에서는 세계최초로 몰타르(Mortar)로 충진되어 있는 해저터널에서 전력케이블과 가스배관이 병행할 경우, 유도에 의한 교류부식에 대하여 검토하였으며, 아직 국내에는 유도전압 제한치가 마련되어 있지 않으므로 인$\cdot$축의 안전적인 측면과 시스템의 보안적인 측면을 세심하게 검토하여 이에 대한 제한치를 정립하였고, 유도전압이 최소가 되도록 전력케이블의 상배치를 최적으로 설계하였다. 이 결과들은 실 사례에 적용되었다.

  • PDF