• Title/Summary/Keyword: Underground infrastructure

Search Result 252, Processing Time 0.022 seconds

Towards high-accuracy data modelling, uncertainty quantification and correlation analysis for SHM measurements during typhoon events using an improved most likely heteroscedastic Gaussian process

  • Qi-Ang Wang;Hao-Bo Wang;Zhan-Guo Ma;Yi-Qing Ni;Zhi-Jun Liu;Jian Jiang;Rui Sun;Hao-Wei Zhu
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.267-279
    • /
    • 2023
  • Data modelling and interpretation for structural health monitoring (SHM) field data are critical for evaluating structural performance and quantifying the vulnerability of infrastructure systems. In order to improve the data modelling accuracy, and extend the application range from data regression analysis to out-of-sample forecasting analysis, an improved most likely heteroscedastic Gaussian process (iMLHGP) methodology is proposed in this study by the incorporation of the outof-sample forecasting algorithm. The proposed iMLHGP method overcomes this limitation of constant variance of Gaussian process (GP), and can be used for estimating non-stationary typhoon-induced response statistics with high volatility. The first attempt at performing data regression and forecasting analysis on structural responses using the proposed iMLHGP method has been presented by applying it to real-world filed SHM data from an instrumented cable-stay bridge during typhoon events. Uncertainty quantification and correlation analysis were also carried out to investigate the influence of typhoons on bridge strain data. Results show that the iMLHGP method has high accuracy in both regression and out-of-sample forecasting. The iMLHGP framework takes both data heteroscedasticity and accurate analytical processing of noise variance (replace with a point estimation on the most likely value) into account to avoid the intensive computational effort. According to uncertainty quantification and correlation analysis results, the uncertainties of strain measurements are affected by both traffic and wind speed. The overall change of bridge strain is affected by temperature, and the local fluctuation is greatly affected by wind speed in typhoon conditions.

Drainage system for leakage treatment of cement concrete structure in underground (콘크리트 지하구조물 누수 처리를 위한 유도배수시스템)

  • Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.573-585
    • /
    • 2019
  • The objective of this study is to propose the drainage system that has been improved the workability, waterproofing and drainage performance to treat the leakage from the cement concrete structures in underground. It is improved that the pipe for conveying ground leak in the existing drainage system had the problem in workability and waterproof. The drainage systems with the improved pipe for conveying ground leak were constructed in conventional concrete lining tunnels to evaluate the workability, waterproofing and drainage. The waterproof and the drainage performance of the drainage system was evaluated by injecting 1,000 ml of red water in the back of the drainage system at 3 weeks, 6 weeks, 9 weeks, 11 weeks, 14 weeks, 17 weeks and 23 weeks. During 6 months of field performance test, the average daily temperature of the tunnel site was measured from $-12.4^{\circ}C$ to $19.7^{\circ}C$. The daily minimum temperature was $-17.2^{\circ}C$ and the daily maximum temperature was $26.7^{\circ}C$. There was no problem in waterproof and drainage performance on the pipe for conveying ground leak and the drainage system during 6 months for field performance test. It is concluded that the improved drainage system can be applied to various cement concrete underground structures where leakage occurs, and has little seasonal effect.

A Case Study on Electronic Recognition Sensor for Underground Facility Management System (지중 매설물 이력 관리 시스템 개발을 위한 전자인식기의 현장 적용성 검증 연구)

  • Jung, YooSeok;Kim, Soullam;Kim, Byungkon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.777-785
    • /
    • 2021
  • Many utility lines are buried underground to provide various functions of the city. Because historical records are not managed systematically, damage has occurred during excavation. In addition, the demand for an underground facility management system is increasing as the aerial underground project is progressing. By attaching an electronic recognition sensor to an underground facility, such as pipelines, the management history and site conditions can be carefully managed. Therefore, in this study, electronic recognition sensors, such as BLE Beacon, UHF RFID, geomagnetic sensor, and commercial marker, were tested to analyze the strengths, weaknesses, and field applicability through a pilot project. According to the limited research results collected through two pilot projects, the installation depth is most important to demonstrate the performance of the electronic reader. In addition, because it should be used in urban areas, the influence of environmental interference should be minimized, and there should be no performance degradation over time. In the case of the geomagnetic recognizer, the effect of environmental interference was large, and performance degradation occurred over time using the BLE Beacon. In the field situation, where the installation depth can be controlled to less than 40cm, the utility of the battery-free UHF RFID was the best.

Stability Analysis of Upper Structures by Soil Grouting (지반 그라우팅에 의한 상부구조물의 안전성 분석)

  • Hwang, Chulsung
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.58-65
    • /
    • 2013
  • Transportation and further expansion of social infrastructure was needed along the development of urbanization and population concentration. To use the underground space due to the lack of availability of land, it is inevitable to intersect between present structure and tunnel during construction. Soil grouting is one of the ground improvement methods to reinforce weak soil around the underground structures by injection of grouting liquid. Some of central columns of an upper structure are damaged during injection of grouting liquid by injection pressure. To investigate and improve the stability of the tunnel, three dimensional analysis are performed with full construction stages which includes the construction of present underpass, damaging columns of the underpass, reinforcing the columns by H-pile and shear walls, and excavation and construct tunnel. The arrangement of grouting holes such as curtain and horizontal type affects largely to the stability of upper structure and horizontal arrangement diminish the shear forces which is the cause of damage of central columns. The liquid injection type of reinforcement for tunnel is not recommended while the presence of upper structure with columns. Wall type reinforcing is utilize for permant support of upper structures which is affected by grouting injection pressure. H-pile is utilize for temporary support, but not for permanent since the sharing of shear forces is not much to shear wall during tunnel construction.

Present Condition and Direction of Improvement for Future Technology on the Prevention and Reclamation of Mining Induced Subsidences (지반침하 방지기술의 현황 및 발전방향)

  • Bang, Ki Mun
    • Tunnel and Underground Space
    • /
    • v.27 no.6
    • /
    • pp.377-386
    • /
    • 2017
  • This study was carried out to predict the future technology on the prevention and reclamation of mining induced subsidences in Korea. We summarized the technical improvement of ground surveys and investigation, ground stability assessment, ground reinforcement, ground monitoring system and so on. It is essential to improve the technology that we try to collect and review all the data that is implemented on the site of mined area in Korea and collaborate all the members of public and private business sectors. We, also, try to expand our business area to related industry such as tunnelling, civil infrastructure, underground environmental assessment etc, and continue to develop oversea's market.

Fire Endurance Estimate of Reinforced Concrete Structure Using Nonlinear Finite Element Method (비선형 유한요소해석을 이용한 철근콘크리트 구조물의 내화성능평가)

  • Byun, Sun-Joo;Im, Jung-Soon;Hwang, Jee-Wook
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.1 s.20
    • /
    • pp.17-27
    • /
    • 2006
  • To estimate the retained strength of reinforced concrete structure after fire is very difficult because the complex behavior of structure is hard to understand during course of a fire. However, the damages which is caused by fire of the traffic facility infrastructure are enormous. Therefore the security against fire is important element that must not be overlooked. For this reason, an exact estimate method of the fire endurance is highly demanded. In this study, the validity of the nonlinear finite element method approach for the fire endurance of reinforced concrete structure is verified. The results of fire endurance estimate of underground road way by nonlinear finite element method approach are compared with those by ACI 216R-89.

Derivation of risk factors according to accident cases related to subway structures

  • Park, Hyun Chul;Park, Young Gon;Pyeon, Mu Wook;Kim, hyun ki;Yoon, Hee Taek
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.5
    • /
    • pp.329-341
    • /
    • 2021
  • This study derives the risk-Influence factors for subway structures, the basis for the transition from the current subway disaster recovery-oriented maintenance system to a preemptive disaster management system, to reduce risk factors for existing subway structures. To apply reasonable risk assessment techniques, risk influence factors for subway underground structures using statistical information(spatial information) and risk influence factors according to frequency of accidents were selected to derive the risk factors. The significant risk factors were verified through ground subsidence (SI: Subsidence Impact)-based correlation analysis. This process confirmed that the subsidence of the ground was a risk influence factor for the subway structure. The main result of this study is that derive the risk factors to improve the risk factors of subway structures due to the rapid increase in disaster risk factors. The derived risk factors that were expected to affect the depression around subway stations and track structures did not show a noticeable correlation, but the cause of this may be that there is no physical connection between them, but on the other hand, the accumulated data may not accurately record the surrounding depression. Accordingly, in order to evaluate the risk of depression around the station and track, more intensive observation and data accumulation around the structure are required.

A Study on the Dataset Structure of Digital Twin for Disaster and Safety Management (재난안전관리를 위한 디지털 트윈 데이터셋 구조 연구)

  • Ki-Sook Chung;Woo-Sug Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.89-95
    • /
    • 2023
  • The underground utility tunnel is an urban infrastructure that accommodates and manages important facilities such as water and sewage, electricity, and communication in the city, and is a national facility that needs to be protected from disasters such as fire, earthquake, and flooding. In establishing a disaster safety life cycle management system such as prediction, prevention, preparedness, response, and recovery, a disaster safety management platform for underground utility tunnel is being developed by utilizing digital twin technology in which advanced ICT technology and data are converged. In this paper, the maturity model for the disaster safety digital twin was reviewed, and the datasets necessary for implementing the digital twin at each stage were defined.

Nature-adapted Rainwater Management Facility Cases in Korean Apartment Complexes (국내 공동주택단지 자연 순응형 빗물관리시설 사례 분석)

  • Hyun, Kyoung Hak;Chang, Sun Young;Ahn, Sung Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.111-119
    • /
    • 2006
  • In Korea, an environment-friendly concept of "rain re-cycling" was initially introduced in apartment complex planning and designs in the late 1990s. Although its application cases are extremely few, with the growing importance of rainwater utilization, introduction of rainwater management facilities in urban areas began to drawn keen attention. In urban areas also, plans to introduce rainwater management facilities in apartment complexes as infrastructure improving living environment, such as sewage treatment facilities are very urgently required. In order to introduce rainwater management facilities as infrastructure in an apartment complex, apartment complex cases that had introduced the facilities were reviewed first. In this study, a few applied rainwater management facilities in an apartment complex were surveyed(Infiltration barrel, Rubble porosity storage tank, Underground storage tank). As a result, problems in introducing rainwater management facilities in apartment complexes in Korea were identified.

Restoration of Water Cycle by a Rainwater Management System Applied to Low Impact Development (LID) (저영향개발 (LID)을 적용한 빗물 관리 시스템에 의한 물 순환 복원)

  • Lee, Dong Chan
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.130-133
    • /
    • 2016
  • The increase in impervious surfaces due to urban development has caused a groundwater drawdown through the reduction of underground infiltration, flood disaster due to increased rainfall runoff and environmental pollution in higher pollutant concentrations of first flush rainwater. As an alternative to these problems, the needs of low impact development (LID) techniques is increasing in urban areas. In this study, the restoration efficiency of water cycle was assessed at a residential site development applied with the LID rainwater management system. The results of monitoring the water cycling showed that the efficiency of water cycle of LID rainwater management system was improved 41% more than that of conventional methods.