• Title/Summary/Keyword: Underground facilities

Search Result 632, Processing Time 0.041 seconds

Open GIS Component Software Ensuring an Interoperability of Spatial Information (공간정보 상호운용성 지원을 위한 컴포넌트 기반의 개방형 GIS 소프트웨어)

  • Choe, Hye-Ok;Kim, Gwang-Su;Lee, Jong-Hun
    • The KIPS Transactions:PartD
    • /
    • v.8D no.6
    • /
    • pp.657-664
    • /
    • 2001
  • The Information Technology has progressed to the open architecture, component, and multimedia services under Internet, ensuring interoperability, reusability, and realtime. The GIS is a system processing geo-spatial information such as natural resources, buildings, roads, and many kinds of facilities in the earth. The spatial information featured by complexity and diversity requires interoperability and reusability of pre-built databases under open architecture. This paper is for the development of component based open GIS Software. The goal of the open GIS component software is a middleware of GIS combining technology of open architecture and component ensuring interoperability of spatial information and reusability of elementary pieces of GIS software. The open GIS component conforms to the distributed open architecture for spatial information proposed by OGC (Open GIS Consortium). The system consists of data provider components, kernel (MapBase) components, clearinghouse components and five kinds of GIS application of local governments. The data provider component places a unique OLE DB interface to connect and access diverse data sources independent of their formats and locations. The MapBase component supports core and common technology of GIS feasible for various applications. The clearinghouse component provides functionality about discovery and access of spatial information under Internet. The system is implemented using ATL/COM and Visual C++ under MicroSoft's Windows environment and consisted of more than 20 components. As we made case study for KSDI (Korea Spatial Data Infrastructure) sharing spatial information between local governments, the advantage of component based open GIS software was proved. Now, we are undertaking another case study for sharing seven kinds of underground facilities using the open GIS component software.

  • PDF

A Study on the Improvement of the Disaster Prevention and Control System for Underpasses by Analytic Hierarchy Process (계층분석법을 통한 지하차도 재해 예방 및 제어 시스템 개선 연구)

  • Kim, Phil Do;Kim, Kyoung Soo;Moon, Yoo Mi
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.734-746
    • /
    • 2020
  • Purpose: Increase in the size and number of underpasses rises occurrence of disasters such as fire and flooding inundation in underpasses. In the occurrence of disasters, the underpasses are more vulnerable to expose of crucial disasters than the general roads due to they are built underground. Therefore, The purpose of this paper is to derive system improvement items to prevent and control disasters in underpasses. Method: A hierarchical model of disaster impact factors and alternatives was developed based on prior researches and expert advices on disaster analyses and impact factors in the underpasses. The developed model was employed for surveys of pairwise comparison, and rankings of improvement were determined by applying the AHP method. Result: With a consistency of the surveys, results of relative weights of evaluation criteria(traffic accidents, fire, flooding inundation) and alternatives(law, system/planning, maintenance/human factor/environment) shows that improvement of laws and system related to the fire disaster is a top priority to prevent and control disaster of the underpasses. Conclusion: From experts' point of view, strengthening laws and systems related to disater prevention facilities such as water spray facilities, external(ground) exit in relation to fire in underpasses showed that it is an alternative to prevent disasters and minimize damage to underpasses.

The Impact of the Wayfinding Ability to Use Satisfaction and Intention to Revisit, Recommendation: Focusing on COEX Mall (길찾기 능력이 이용 만족도 및 재방문 의도, 추천의도에 미치는 영향: 코엑스몰을 중심으로)

  • Park, Kyoung-Ha;Youm, Dongsup
    • Journal of Digital Convergence
    • /
    • v.11 no.8
    • /
    • pp.109-117
    • /
    • 2013
  • This study was to evaluate the impact of the wayfinding ability of the individual visitor attitudes. These wayfinding ability to analyze the preceding literature, were examined for the ability to determine whether any relationship and the attitude of the place for visitors. Firstly, the users' wayfinding abilities were identified as partially affecting the use satisfaction. Second, users' wayfinding abilities were identified as partially affecting revisit. Third, users' wayfinding abilities were identified as partially affecting recommendations. Finally, revisit and recommend to influence users' satisfaction were identified. Than the results of this study considering the structural characteristics of the space underground commercial facilities with the ground and the need for other forms of communication design, marketing strategy, especially considering the key aspects of complex commercial facility services space with the need for practical significance for can be said to have.

A Study on the Behaviour of the Station Structure due to Adjacent Construction (근접시공에 따른 정거장구조물 거동특성에 관한 연구)

  • Chung, Jeeseung;Kim, Manhwa;Lee, Sungil;Kim, Hongjoo;Shin, Youngwan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.11
    • /
    • pp.55-64
    • /
    • 2016
  • Recently, it has been made many adjacent construction of inter-facility by the expansion of urban infrastructure facilities using the underground space. The complaints relating to the stability of the facility by adjacent construction is common. In this study, it was conducted for the subway line 5 Gimpo airport station structure in the upper Gimpo urban railway to determine the behavior characteristics of station structure according to adjacent construction. It was performed evaluation of the safety zone and excavation method for station structure. And after a review of damage evaluation, track irregularities and structural calculation by using a numerical analysis, stability of the station structure according to adjacent construction was evaluated to be secured. This study is expected to be used as basic data in advance if you need to review the effects of nearby structure according to adjacent construction.

Operation Characteristics of the HVAC System Installed in Ancient Tomb (고분내부에 설치된 공조시스템의 운전특성)

  • Jun, Yong-Du;Lee, Kum-Bae;Jun, Hee-Ho;Ko, Seok-Bo;Park, Jin-Yang;Youn, Young-Muk
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.202-208
    • /
    • 2006
  • Although the importance of good conservation of historic sites including ancient royal tombs is well aware, still not much attention has been paid for the facilities and systems to preserve those historic sites, which includes precious artifacts as wall paints and carved works, etc. Even the general understanding about the environment of the underground space or tombs is not satisfactory. In the present study, vibration levels due to the operation of an HVAC system to maintain the desired indoor temperature and humidity are investigated experimentally. According to the measured data, the level of vibration inside the present model tomb with the indoor unit inside, showed order of magnitude less values than the Swiss Standards, but still higher than the value suggested by German standards, which is, zero. Further study will be pursued for cases including different ways of installation, because the vibration level depends not only on the system design, but also on the installation methods.

The Intelligent Information Service Model of Urban Spatial Information for u-UIS - Focused on Urban Ground and Underground Facilities (u-UIS 도시공간정보 연계통합 모델 - 지상.지하시설물을 중심으로 -)

  • Kim, Eun-Hyung;Choi, Hyun-Sang;Kim, Tae-Hoon
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.1
    • /
    • pp.189-194
    • /
    • 2009
  • With the rapid development of information and telecommunication technologies, the adoption of ubiquitous technologies is increasing for the realization of new effective u-City services. u-City is defined as a next-generation informatization city that can innovate a city's various functions, such as improving the welfare of the citizenry, ensuring safety based on systematic urban management, improving the quality of lives, and increasing convenience in city life, by merging cuttingedge information and telecommunication infrastructures and ubiquitous information services with urban space. There is therefore a need to recognize that a successful u-City implementation strategy involves developing the previous UIS into a ubiquitous technology-based UIS and integrating UIS's various urban informations with effective u-City services. In this paper, for UIS-based u-City implementation, the intelligent integration model of urban spatial information based on interoperability is proposed.

  • PDF

A Optimization of Fire Safety Design in Multiplex Cinema Theater (국내 복합상영관 시설의 방재대책에 관한 연구)

  • 허준호;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2002
  • 21C, Multiplex Cinema Theater is made from movie industry developed and become a place where we can spend our free time and consuming. But, theater users, who are many and unspecified persons, are short of information on the Multiplex Cinema Theater, so that they may be injured or killed at the occurrence of fire accident. Particularly, Multiplex Cinema Theater is a place that underground space or top floor in highrise building had many people in theaters. However, this problem is difficult to solve that to protect human being and properties at the occurrence of fire accident in the Multiplex Cinema Theater, In order to overcome such problems, Multiplex Cinema Theater need fire protection solutions facilities concerning particulars to pay attention to the safety on a fire and evacuation. This study analysed Multiplex Cinema Theater concept and computer simulation for risk point.

The Mixed Charging Method with Low-velocity Explosives and Normal Explosives in Tunnel Blasting (터널 발파에서의 저폭속폭약과 일반폭약의 혼용장약법)

  • Kang, Dae-Woo;Ahn, Bong-Do
    • Tunnel and Underground Space
    • /
    • v.20 no.4
    • /
    • pp.252-259
    • /
    • 2010
  • In urban tunnels, namely, in case there are residents in the near distance, we normally use non-vibration and ambient vibration which are not blasting methods because it’ impossible to meet the blasting vibration regulation with only normal explosives. However, non-vibration methods not only cause increase of excavating cost, but need much time than explosives. Generally, the lower velocity explosives with 2,000 m/s VOD have been applied to ambient vibration blasting in open cut area, but difficult in tunneling in its use. However, by charging the hole together with lower velocity explosives and normal explosives, we have got the result which shows 20~30% vibration decrease compared with using only normal explosives. Therefore, I’ like to suggest the blasting method which is able to do as ambient vibration using lower velocity explosives mixed with normal explosives in urban tunnel and the area which is adjacent to security facilities within the vibration regulation.

A Study on Simulator for Environment Control of Agricultural Production Facility - Construction of Basic System with Numerical Model - (농업생산시설의 환경조절용 시뮬레이터에 관한 연구 - 수치모델에 의한 기본시스템 구축 -)

  • 손정익;최규홍
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.111-119
    • /
    • 1996
  • The purpose of this study is to construct the main system of simulator for the environment control of agricultural production facilities. The model describing the system was based on the energy and mass balance in an unsteady - state situation. The model consist of the three major parts : the main model, the light model, and the environmental control model, and each part was separated to be developed individually. The main model which is the core of this system includes the thermal model, the soil model, the ventilation model, the cultivation model, and the carbon dioxide model. And also the environmental control model includes the thermal curtain model, the heater/cooler model and the underground heat exchanger model. The equations used in this model were written in analog programming methods using PCSMP The simulator was evaluated through comparison between simulated and measured temperatures controlled during daytime and night. The results showed good agreements between the predicted and measured temperatures.

  • PDF

A Study on Facility Criteria of Small Petrol Stations based on Quantitative Risk Assessment (정량적 위험성 평가에 기반한 간이 주유취급소 시설기준에 대한 연구)

  • Park, Wooin;Ku, Jae-Hyun;Song, Yong-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.44-52
    • /
    • 2014
  • Small petrol stations have great potential for a wide distribution in metropolitan area in which the land value possesses primary installation cost of the facility. The objective of the present study is to propose appropriate facility regulations of small petrol stations in Korea that can be popularly installed in the future in terms of securing safety in addition to serviceability. The hazard analysis and damage prediction from the possible fire and explosion accidents were performed using a software, PHAST v.6.5. As essential components of the facility regulations proposed in this study, the regulations about the refueling lot, maximum capacity of underground tank, location of fixed refueling facilities, height of firewall for small petrol stations were subsequently compared with those for regular-sized petrol stations.