• Title/Summary/Keyword: Underground Dwellings

Search Result 6, Processing Time 0.055 seconds

A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer (지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구)

  • Kwon, Young Cheol;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.

The Health Hazard of Geomagnetic Field in Dwellings (주거에서 지자기장의 위해성에 관한 기초연구)

  • Han, Jong-Koo;Park, Tong-So
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.43-49
    • /
    • 2005
  • People grow up and build up most of their character through living in dwelling space and have relax and refresh at home. Creating healthy dwelling space is being considered very important in architectural planning and design for providing comfortable living environment and improving quality of life. One of the properties of the earth is that the earth has a magnetic field associated with it- the Geomagnetic field. The geomagnetic field is produced by a combination of crustal rocks, external electric current systems that surround the earth that surround the earth and currents induced in the outer layers of the earth by magnetic field variations. Human beings have evolved with the background of magnetic field, they are accustomed to living in its presence. Geopathic stress occurs at geopathic zones where the geomagnetic field is disturbed. Geopathic zones exhibit magnetic charges. Geopathic zones are characterized by variations in geomagnetism, for the geomagnetic field is not uniform but exhibits many highly localized distortions, some random, some fairly regular. These occur in geological faults, caves and underground water channel. Many research papers and experiments of the western countries indicates that the geomagnetic field affects the people and living organism in dwellings. Therefore, it is necessary to investigate the geomagnetic field and people's response in living space. In this study the Health Hazard of geomagneic field in dwelling are studied through literature survey of related science field.

Risk Factor Selaction and Safety Management Plan in the Underground Excavation Construction (지반굴착공사에서의 위험요인 선정과 안전관리방안 연구)

  • Won, Yu-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.31-37
    • /
    • 2019
  • When the foundation work of the underground part of the building structure or the excavation work of the civil engineering structure is carried out, there is the earthwork work by the inevitable process. As the economic situation continues to develop, construction in urban areas is becoming bigger and higher in scale due to the expansion of infrastructure and the rescue of urban dwellings in urban areas, and excavation of underground roads is inevitable. Excavation of the underground part may cause problems in the process difficulty and safety of the earthworks due to the complexity and various characteristics of the ground selected without consideration of the ground characteristics and site conditions. In order to complete the required facilities, it is necessary to secure the design and construction of the retaining walls. In order to complete the required construction, It is an important factor satisfying construction period and economical efficiency.

A Preliminary Investigation of Radon Concentration for Some Agricultural Greenhouses in Jeju Island (제주지역 일부 농업 시설 내 라돈 농도 예비 조사)

  • Kang, Tae-Woo;Song, Myeong-Han;Kim, Tae-Hyoung;Chang, Byung-Uck;Kim, Young-Jae;Kim, Geun-Ho;Park, Jae-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • BACKGROUND: A preliminary investigation of the radon ($^{222}Rn$) concentration has been conducted, employing solid-state nuclear-track detectors (SSNTD) and a continuous radon monitor (CRM), for fourteen randomly selected agricultural greenhouses in Jeju Island, where the underground-air was used for air conditioning and $CO_2$ supplement. METHODS AND RESULTS: The SSNTD was used to measure the average radon concentration for three months and the CRM was used for an instantaneous measurement. In order to obtain the radon concentration of a greenhouse, the SSNTDs were placed at a number of evenly distributed points inside the greenhouse and the mean of the measured values was taken. In addition, in order to assess the radon concentration of the underground-air itself, measurement was also made at the borehole of the underground-air in each agricultural facility, employing both the SSNTD and CRM. It is found that the radon concentration of the greenhouses ranges higher than those not using the underground-air and the average of Korean dwellings. While the radon concentration of most agricultural facilities is still lower than the reference level (1,000 Bq/$m^3$) recommended by the International Radiation Protection Committee (ICRP), three facilities at one site show higher concentrations than the reference level. The three-month-averaged radon concentration and the instantaneous radon concentration of the underground-air itself ranges 1,228- 5,259 and 3,322-17,900 Bq/$m^3$, respectively, and regional variation is more significant. CONCLUSION: From this results, radon concentration of the underground-air is assumed that it is associated with the geological characteristics and the boring depth of the region located of their.

The Influence of the Presence of Balconies on Flame Acceleration in Multi-unit Dwellings (공동주택의 발코니 유·무가 화염분출 특성에 미치는 영향 연구)

  • Kang, Youn-Gyu
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.1-6
    • /
    • 2016
  • We are living in the 21st century, a new era of high-technology. Due to movements in population towards certain preferred areas, caused by material and technological advancement, growth has occurredn beyond the metropolis, leading to the development of the so-calleda "megalopolis." This development has changed the culture of housing, notably the characteristics of high-rise buildings, and underground facilities (such as subways and shopping centers), and has generally enlarged the scale of the facilities. Due to the increase in the number of single-family households, - notably ones including only the nuclear family, there has been a growing overpopulation problem, with apartments and urban housing developments expanding at rates beyond institutional safety regulations. In this study, we analyze the phenomenon of fire spreading in apartment buildings through actual apartment fire case studies, including that of the MunjonPonpuri apartment building. It was found that the speed at which the fire spreads is lower in apartments without than in those with an extended balcony. Based on the findings from case studies and the test results, we propose a series of safety countermeasures and responses for apartment fires.

A Study on the Improvement of Dairy Rousing Systems in Kore (한국의 낙농시설 개선에 관한 연구)

  • Kim, Moon-Ki;Koh, Chae-Koon;Kim, H. U.
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.1
    • /
    • pp.31-43
    • /
    • 1982
  • Engineering phase of dairy housing systems has close connection with the milk produc- tivity of dairy cattle, the quality of milk, extension of dairy production systems, labor- saving in management of dairy cattle and the like. Moreover, the rate of investment of dairy housing facilities is of relatively high level, However, there has been almost no research effort for the improvement of engineering aspects of dairy housing systems in Korea. The purpose of this study is to find out general engineering problems and to recomm- end the improvement in dairy housing systems in Korea. Field survey by means of questionaire, direct measurements, taking pictures and sketching was conducted to get necessary information for the study. Kyung-ki Do region was firstly chosen for sampling area since it has included more than half of the number of dairy farms of the whole country. The results obtained are summarized as follows: 1. In overall dairy farm layout, the dwellings of workers were ignored in the light of sanitary environment 2. The layout of stalls in a dairy barn belongs mostly to the type of double-row face-out, which is compatible with the emphasis of manure disposal activities. 3. While the width and length of stalls were sufficiently close to the standard dimension, the width of mangers was much less than the standard dimension. 4. The width and depth of manure gutters and the width of working alleys were much. less than the standard dimension. 5. The mooring equipment was mostly in the classes of chain or rope. The watering equipment was not facilitated independantly except the one cese of using watercup. 6. The bucket milkers with one or two bucket milkers with the capacity of two cattles. each were used as milking equipment in most dairy farms. 7. There were only few milk rooms independently spaced from other space, in which the arrangement of milking equipment was much less than the standard condition. 8. The lounging ground area was averaged to be sufficient for the activity of dairy herd. 9. Silos for silage used during winter consisted of mostly bunker silos, trench silos and underground vertical silos. Ordinary vertical silos were considered for the farmers to be inconvenient for the labor saving. 10. From the view point of heat conservation and moisture removal within the dairy barns, windows were not flexible for the easy ventilation and ceiling part was not adequate for temperatur maintenance. 11. Waste treatment and disposal systems were not provided with most dairy farms, therefore the livestock waste pollution problems would be serious in the near future.

  • PDF