• 제목/요약/키워드: Underground Distribution Equipment

검색결과 28건 처리시간 0.026초

지중배전계통 보호설비 적정위치 선정을 위한 실증시험과 해석 (Field Test and Analysis for Proper Location of Protective Equipment in Underground Distribution System)

  • 윤창섭;이종범
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.773-782
    • /
    • 2008
  • This paper describes the method for proper location of protective equipment in underground distribution cable through field test and analysis at testing lines. To prove the reliability for analysis simulated by EMTP/ATPDraw, the testing results obtained by the real test and the analysis for the same test lines were compared each other. The accuracy of analysis was proved by the comparison. Over voltages were measured and analyzed at each point of cable and switches in case of which lightning surge current was applied. The analysing method was applied to real distribution systems to select the proper location of protective equipment. It is evaluated that the location of protective equipment was properly selected.

DTS를 활용한 광복합 지중 배전계통 실시간 감시시스템 개발 및 성능평가 (A Development and Performance Assessment of On-Line Monitoring System for Optical Fiber Composite Underground Distribution Network using DTS)

  • 조진태;김주용;이학주;조휘창;최명호
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.115-121
    • /
    • 2011
  • Intelligent distribution equipment is inevitable to realize self-healing which is one of smart grid functions in distribution network. Therefore, most of distribution equipment have been developed with self diagnostic sensors. However, it is not effective to construct on-line monitoring system for underground distribution cable because of high cost and low sensitivity. Recently, optical fiber composite cable is being considered for communication and power delivery in order to cope with increasing communication in distribution network. This paper presents the design and performance assessment results of underground cable on-line monitoring system using DTS(Distributed Temperature Sensing) and optical fiber composite underground cable.

지중배전선로의 다회로차단기 운영방안 연구 (The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF

지하공간 화재시 배연장비의 활용에 관한 연구 (A Study on the Application of Ventilation Equipment in an Underground Fire)

  • 이성룡;한동훈
    • 터널과지하공간
    • /
    • 제20권2호
    • /
    • pp.92-96
    • /
    • 2010
  • 본 연구에서는 지하공간에서 화재 발생시 배연장비의 연기배출 성능을 평가하기 위하여 실험을 실시하였다. 배연장비로는 이동식 송풍기를 사용하였으며 가연물질로는 에탄올을 사용하였다. 한 변의 길이가 80cm의 정사각형 화원을 사용하였으며 최대 열방출률은 약 460 kW이다. 급기방식 배연의 영향을 평가하였다. 급기방식의 경우 실내의 가시도 향상 및 온도감소 효과를 확인할 수 있었다.

지중배전공사에 설치되는 기기의 설치위치에 따른 영향 분석에 관한 연구 (A Study on the Analysis of Efficiency for Underground Distribution Equipment by Installment Ways)

  • 김준일;김동명
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.83-89
    • /
    • 2009
  • 최근 국내 전력산업의 주변 환경, 즉 전기요금의 가격, 환경보호 및 에너지 문제 등으로 인해 전기사업을 보다 능동적으로 운영하기 위한 필요성이 제기되고 있다. 지금까지 대부분의 전력회사에서는 전력계통의 신뢰도에 중점을 두고 전력을 공급하였지만 모든 조건에 일률적으로 적용하는 것은 막대한 비용 상승을 동반하기 때문에 전력회사에서는 전력설비를 설치 또는 운영하는 것에 대해 보다 유연하게 대처하기 위하여 기기 투자비용에 대한 가치 및 이득을 검토하는 것이 필요하다. 따라서 본 연구에서는 지중배전기기의 설치위치별로 국외 사례 및 국내 환경을 고려하여 그 효과를 분석하였으며, 본 연구결과는 향후 지중배전기기의 현장 적용 시 검토방안과 대책으로써 활용이 기대된다.

지중배전선로의 고장전류 크기 및 보호협조분석 (Ananalzing fault current and Protective coordination in the underground line)

  • 조남훈;하복남;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

U-CDS의 자연환기를 위한 AirDam시스템의 효과에 대한 연구 (System Effectiveness of AirDam for Natural Ventilation by U-CDS)

  • 김승철;신부현;오기대
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.87-92
    • /
    • 2022
  • Recently, there has been an increasing demand for electric equipment installed on the ground to be installed in an underground space. Accordingly, U-CDS (Underground-Compact Distribution Station) installed in the underground is supplied, and to improve its weak ventilation performance, an Airdam-type structure was applied and the effect was analyzed. As a result, the temperature around the transformer was reduced by up to 9.5 degrees, and the air flow increased by up to 1.17 m/s. Airdam structure can be supplied in the form of various sculptures because it is possible to design freely while maintaining its principle.

냉방설비 성능개선 및 에너지 절약을 위한 응결수 활용성 분석 (An analysis on the utility of congealing water to improve efficiency of the air cooling equipment and save energy)

  • 박근수;박영호;유정범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.974-981
    • /
    • 2007
  • Seoul Metro has operated the air cooling equipment established in a machine room of a station building to improve our services focused on our customers who use Seoul Metro during the summer season. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. One of them is loss of efficiency in the air conditioner. The leading cause of this problem is that we use an underground type of the cooling tower. As the machine room of a station building is located in the underground of inner city because of the nature of the subway, it is difficult to establish the cooling tower on the ground. The underground structure of the No. $1{\sim}4$ subway line is unsuitable for the location requirements of the underground type of the one because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. Accordingly, the efficiency of the air conditioning is getting lower and lower. Another problem is too wasteful with water. Each station uses the water over 30 tons every day with waterworks to replenish the cooling tower such as a evaporation, a scattering and a distribution of water. Nevertheless, the more an air conditioner increase, the more the use of water supply increase. For this reason, we can't help wasting an enormous amount of water and discharging the congelation of a low temperature(about $15^{\circ}C$) occurred in a heat exchanger inside an air conditioner. The purpose of this study is to analyze the utility of congealing water to improve efficiency of the air cooling equipment and save energy as a supplementary water for the cooling tower.

  • PDF

초저주파전원을 이용한 지중배전 전력케이블의 결함검출 (Defects Detection of the Underground Distribution Power Cables by Very Low Frequency Voltage Source)

  • 김주용;송일근
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.45-50
    • /
    • 1998
  • 본 논문은 기존의 지중배전케이블의 준공시험으로 사용되고 있는 DC시험을 대체 하기 위한 초저주파 전원의 적용결과로서, 실험실에서 제작한 5m 길이의 실제 케이블의 칼흠집 결함과 침결함에 대해 초저주파 전원의 결함검출 능력을 평가하였다. 이 시험에서 초저주파 시험은 케이블 절연체 내부에 존재하는 결함부위에서 전기트리 개시는 어렵지만, 일단 전기트리가 개시되면 트리의 진전이 매우 빠르고 내부결함이 검출되지 않는 경우, 시험으로 인한 새로운 결함이 형성되거나 결함이 더 확대되지 않는 것으로 나타났다. 따라서 초저주파전원은 지중배전선로의 현장시험용으로 적용되기보다는 제조업체의 품질검사 확인용으로 사용하는 것이 효과적이라 판단된다.

  • PDF

연약점토층위 이층지반 지표면 재하시 지중응력 특성연구 (A Study on the Distribution Stresses beneath Loaded Ground Surface Area of Double Strata Ground on Soft Clay Layers)

  • 이인형;임종석
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.47-57
    • /
    • 2005
  • Stress distribution in soils is the very important element to design and to solve the problems of settlement, safety of foundations and trafficability of constructing vehicle in civil engineering. This research presents the comparative estimation of the actual and theoretical measurement on the underground stress of outer layer for each soil after the observation of each top soil layer fur its vertical and horizontal stresses in (1) homogeneous sand ground (2) weak stratum with the sand soil (3) weak stratum with gravel of the soil model, and it also investigates the effect of subsidence of ground by the repeated load. The underground stresses fumed out to be different in the value of theoretical and actual measurement after the trial examination of model. This study has the purpose of suggesting the better construction method of running equipment on weak stratum by comparing the estimated value of trial experiment and theory on underground stress of the weak ground surface area and of raising up the necessity of the continuous research hereafter.