• Title/Summary/Keyword: Under correction

Search Result 836, Processing Time 0.024 seconds

Destructive testing of adhesively bonded joints under static tensile loading

  • Ochsner, A.;Gegner, J.
    • Journal of Adhesion and Interface
    • /
    • v.5 no.2
    • /
    • pp.22-36
    • /
    • 2004
  • Several in-situ testing methods of adhesively bonded joints under static short-time tensile loading are critically analyzed in terms of experimental procedure and data evaluation. Due to its rather homogeneous stress state across the glue line, the tensile-shear test with thick single-lap specimens, according to ISO 11003-2, has become the most important test process for the determination of realistic materials parameters. This basic method, which was improved in both, the experimental part by stepped adherends and easily attachable extensometers and the evaluation procedure by numeric substrate deformation correction and test simulation based on the finite element method (FEM), is therefore demonstrated by application to several kinds of adhesives and metallic adherends. Multi-axial load decreases the strength of a joint. This effect, which is illustrated by an experimental comparison, impedes the derivation of realistic mechanical characteristics from measured force-displacement curves. It is shown by numeric modeling that tensile-shear tests with thin plate substrates according to ISO 4587, which are widely used for quick industrial quality assurance, reveal an inhomogeneous stress state, especially because of relatively large adherend deformation. Complete experimental determination of the elastic properties of bonded joints requires independent measurement of at least two characteristics. As the thick-adherend tensile-shear test directly yields the shear modulus, the tensile butt-joint test according to ISO 6922 represents the most obvious complement of the test programme. Thus, validity of analytical correction formulae proposed in literature for the derivation of realistic materials characteristics is verified by numeric simulation. Moreover, the influence of the substrate deformation is examined and a FEM correction method introduced.

  • PDF

Strength Correction Factors due to Temperature Drop of Structural Concrete under Low Temperature by the Equivalent Age Method (저온환경에서 타설되는 구조체 콘크리트의 등가재령 방법을 활용한 기온보정강도 설정)

  • Choi, Youn-Hoo;Han, Min-Cheol;Lee, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.5
    • /
    • pp.409-416
    • /
    • 2020
  • In this paper, strength correction factors of the concretes incorporating ordinary Portland cement(OPC), fly ash(FA) and blast furnace slag(BS) with 50% of water to binder ratio due to temperature drop for standard room temperature(20±3℃) are provided. For this, strength development was done based on equivalent age method. For calculating the equivalent age, apparent activation energy was obtained with 24.69 kJ/mol in OPC, 46.59 kJ/mol in FA, 54.59 kJ/ol in BS systems. According to the estimation of strength development of the concretes, the use of FA and BS resulted in larger strength drop than that of OPC under low temperature compared to standard room temperature. Hence, strength correction factors(Tn) for OPC, FA and BS are suggested within 4~17℃ with every 3MPa levels.

CCD Non-uniformity Correction Method based on Pixel Non-Linearity Model (픽셀 비선형성 모델을 기반으로 한 영상센서 불균일 특성 보정)

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • All pixels of image sensor do not react uniformly when the light of same radiance enters into the camera. This non-uniformity has a direct influence on the image quality. However we can overcome it by calibration process under the special test-setup. Usually it is used the algorithm to get the correction coefficients under the specific illumination condition. But, this method has drawback in the very low or very high illumination due to pixel non-linearity. This paper describes the robust algorithm, which calculates the correction coefficients based on the pixel non-linearity model, against thew hole radiance. The paper shows the non-uniformity test results with the own camera and the specified test equipments as well. The results shows the best performance over the entire radiance when this method is applied.

Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study

  • Jeong Bin Park;Yeon Joo Jeong;Geewon Lee;Nam Kyung Lee;Jin You Kim;Ji Won Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.94-101
    • /
    • 2019
  • Objective: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. Materials and Methods: An anthropomorphic dynamic heart phantom was scanned under a static condition and under heart rate (HR) simulation of 50-120 beats per minute (bpm), and the obtained images were reconstructed using conventional algorithm (CA) and MCA. We compared the subjective image quality of coronary arteries using a four-point scale (1, excellent; 2, good; 3, fair; 4, poor) and measurement accuracy using measurement errors of the minimal luminal diameter (MLD) and minimal luminal area (MLA). Results: Compared with CA, MCA significantly improved the subjective image quality at HRs of 110 bpm (1.3 ± 0.3 vs. 1.9 ± 0.8, p = 0.003) and 120 bpm (1.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.006). The measurement error of MLD significantly decreased on using MCA at 110 bpm (11.7 ± 5.9% vs. 18.4 ± 9.4%, p = 0.013) and 120 bpm (10.0 ± 7.3% vs. 25.0 ± 16.5%, p = 0.013). The measurement error of the MLA was also reduced using MCA at 110 bpm (19.2 ± 28.1% vs. 26.4 ± 21.6%, p = 0.028) and 120 bpm (17.9 ± 17.7% vs. 34.8 ± 19.6%, p = 0.018). Conclusion: Motion-correction algorithm can improve the coronary artery image quality and measurement accuracy at a high HR using an anthropomorphic dynamic heart phantom and 256-detector row CT scanner.

Digital Error Correction for a 10-Bit Straightforward SAR ADC

  • Rikan, Behnam Samadpoor;Abbasizadeh, Hamed;Do, Sung-Han;Lee, Dong-Soo;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.1
    • /
    • pp.51-58
    • /
    • 2015
  • This paper proposes a 10-b SAR ADC. To increase the conversion speed and reduce the power consumption and area, redundant cycles were implemented digitally in a capacitor DAC. The capacitor DAC algorithm was straightforward switching, which included digital error correction steps. A prototype ADC was implemented in CMOS $0.18-{\mu}m$ technology. This structure consumed $140{\mu}W$ and achieved 59.4-dB SNDR at 1.25MS/s under a 1.8-V supply. The figure of merit (FOM) was 140fJ/conversion-step.

Aerodynamic Analysis of Horizontal Axis Wind Turbines using Nonlinear Bound Vortex Correction Method (비선형 구속 와류 보정법을 이용한 수평축 풍력 발전기의 공력 해석)

  • Kim, Ho-Geon;Lee, Seung-Min;Lee, Soo-Gab
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.307-310
    • /
    • 2008
  • Nonlinear Vortex Strength Correction Method is developed for improvement of vortex lattice method which can't calculate the separated flow conditions and the viscous effect. In this method, the vortex strength on the blade surface is determined by matching the lift force from vortex lattice method with the lift force from aerodynamic coefficients table as the same circulation is added to or subtracted from all chord wise vortices. For considering the nonlinearities due to the neighboring blade sections, sophisticated Newton-Rapson algorithm is applied. The validation of this method was done by comparing the simulations with the measurements on the NREL Phase-VI horizontal axis wind turbine(HAWT) in the NASA Ames wind tunnel under uniform conditions. This method gives good agreements with experiments in most cases.

  • PDF

A New Single-Stage PFC AC/DC Converter with Low Link-Capacitor Voltage

  • Lee, Byoung-Hee;Kim, Chong-Eun;Park, Ki-Bum;Moon, Gun-Woo
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.328-335
    • /
    • 2007
  • A conventional Single-Stage Power-Factor-Correction (PFC) AC/DC converter has a link capacitor voltage problem under high line input and low load conditions. In this paper, this problem is analyzed by using the voltage conversion ratio of the DC/DC conversion cell. By applying this analysis, a new Single-Stage PFC AC/DC converter with a boost PFC cell integrated with a Voltage-Doubler Rectified Asymmetrical Half-Bridge (VDRAHB) is proposed. The proposed converter features good power factor correction, low current harmonic distortions, tight output regulations and low voltage of the link capacitor. An 85W prototype was implemented to show that it meets harmonic requirements and standards satisfactorily with near unity power factor and high efficiency over universal input.

RICHARDSON EXTRAPOLATION AND DEFECT CORRECTION OF MIXED FINITE ELEMENT METHODS FOR ELLIPTIC OPTIMAL CONTROL PROBLEMS

  • Chen, Yanping;Huang, Yunqing;Hou, Tianliang
    • Journal of the Korean Mathematical Society
    • /
    • v.49 no.3
    • /
    • pp.549-569
    • /
    • 2012
  • In this paper asymptotic error expansions for mixed finite element approximations to a class of second order elliptic optimal control problems are derived under rectangular meshes, and the Richardson extrapolation of two different schemes and interpolation defect correction can be applied to increase the accuracy of the approximations. As a by-product, we illustrate that all the approximations of higher accuracy can be used to form a class of a posteriori error estimators of the mixed finite element method for optimal control problems.

Bandwidth Efficient Adaptive Forward Error Correction Mechanism with Feedback Channel

  • Ali, Farhan Azmat;Simoens, Pieter;de Meerssche, Wim Van;Dhoedt, Bart
    • Journal of Communications and Networks
    • /
    • v.16 no.3
    • /
    • pp.322-334
    • /
    • 2014
  • Multimedia content is very sensitive to packet loss and therefore multimedia streams are typically protected against packet loss, either by supporting retransmission requests or by adding redundant forward error correction (FEC) data. However, the redundant FEC information introduces significant additional bandwidth requirements, as compared to the bitrate of the original video stream. Especially on wireless and mobile networks, bandwidth availability is limited and variable. In this article, an adaptive FEC (A-FEC) system is presented whereby the redundancy rate is dynamically adjusted to the packet loss, based on feedback messages from the client. We present a statistical model of our A-FEC system and validate the proposed system under different packet loss conditions and loss probabilities. The experimental results show that 57-95%bandwidth gain can be achieved compared with a static FEC approach.

Error Correction Coding on the Transform Coded Image Transmission over Noisy Channel (잡음 채널에서 변환 부호화 영상 전송에 대한 에러 정정 부호)

  • 채종길;주언경
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.4
    • /
    • pp.97-105
    • /
    • 1994
  • Transform image coding using DCT is proved to be efficient in the absence of channel error but its performance degrades rapidly over noisy channel. In this paper, in the case of appling bit selcetive error correction coding that protects some significant bits in a codeword, an efficient allocation method of imformation bits and additive redundancy bits used for quantization and error correction coding respectively under constant transmission bit rate is proposed, and its performance is analyzed. As a result, without increasing trasmission bit rate, PSNR can be improved up to 7~8 [dB] below bit error rate $10^2$ and the image without blocking effect caused by bit error resulted from channel noise can be recostructed.

  • PDF