• 제목/요약/키워드: Unconstrained measurement

검색결과 17건 처리시간 0.026초

게이지 R&R 연구에서 근사 F검정과 EMS를 이용한 측정 정밀도의 평가 (Evaluation of Measurement Precisions Using Approximate F Tests and EMS in the Gauge R&R Studies)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제11권3호
    • /
    • pp.209-216
    • /
    • 2009
  • A development in method of evaluating the measurement precisions using approximate F tests and variance components from expected mean square (EMS) is investigated. The research proposes three-factor mixed measurement models with the fixed and random factors. Unrestricted and unconstrained design work was rarely studied, while restricted and constrained designs have been significantly discussed. The unrestricted and unconstrained designs assume to be an independence of interaction. The proposed evaluation method about the measurement precisions can be extended to four-factor random measurement model or mixed measurement model. The study also presents the three evaluation indexes of precisions such as R&RTR (Reproducibility & Repeatability-To-Total Precision Ratio), PTR (Precision-To-Tolerance Ratio), and SNR (Signal-To-Noise Ratio). Numerical examples are proposed to evaluate the approximate F tests with Satterthwaite degrees of freedom and three indexes using the measurement precisions from EMS.

A New Method for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair

  • Kim Ko-Keun;Chee Young-Joon;Lim Yong-Gyu;Choi Jin-Wook;Park Kwang-Suk
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.83-88
    • /
    • 2006
  • A new method of measuring pulse arrival time (PAT), which is usually used for the estimation of systolic blood pressure, in an unconstrained manner using a chair, is proposed. The capacitive-coupled ECG (CC-ECG) measurement system and the air cushion with balancing tubes system were used for unconstrained PAT measurement. Firstly, the correlation between the standard PAT (S-PAT) from the photoplethysmography (PPG) and the PAT measured in an unconstrained manner (U-PAT) was evaluated. It was observed that U-PAT, which is the time delay from the R-peak of ECG to the steepest decent point of air cushion pressure wave, is significantly correlated with the S-PAT. Secondly, systolic blood pressure (SBP) measured by the radial tonometer is compared to the U-PAT. The ten-beat averaged U-PAT removed respiration effects and demonstrated a high intra-subject correlation with SBP in all participants. Finally, the tonometry SBP was estimated from these U-PAT values for one participant intermittently during half a day.

공기 매트리스와 디지털 신호처리를 이용한 홈헬스케어용 무구속 수면 모니터링 시스템 (The Unconstrained Sleep Monitoring System for Home Healthcare using Air Mattress and Digital Signal Processing)

  • 지영준;박광석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.493-496
    • /
    • 2005
  • For home healthcare, the unconstrained measurement of physiological signal is highly required to avoid the inconvenience of users. The recording and analysis of the fundamental parameters during sleep like respiration and heart beat provide valuable information on his/her healthcare. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The balancing tube between two air cells is used to increase the robustness against postural changes during the measurement period. The meaningful frequency range could be selected by the pneumatic filter with balancing tube. ECG (Electrocardiography) and respiration sensor (plethysmography) were measured for comparison with the signal from air mattress. To extract the heart beat information from air pressure sensor, digital signal processing technique was used. The accuracy for breathing interval and heart beat monitoring was acceptable. It shows the potentials of air mattress sensor system to be the unconstrained home sleep monitoring system.

  • PDF

GLM에서 제약과 비제약 혼합모형의 고찰 및 확장 (Extension and Review of Restricted and Unrestricted Mixed Models in the Generalized Linear Models)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 춘계학술대회
    • /
    • pp.185-192
    • /
    • 2009
  • The research contributes extending and reviewing of restricted (constrained) and unrestricted (unconstrained) models in GLM(Generalized Linear Models). The paper includes the methodology for finding EMS(Expected Mean Square) and $F_0$ ratio. The results can be applied to the gauge R&R(Reproducibility and Repeatability) in MSA(Measurement System Analysis).

  • PDF

무구속 심탄도 모니터링 시스템을 이용한 스트레스 분석 기초연구 (Basic Study for Stress Analysis Using an Unconstrained BCG Monitoring System)

  • 노윤홍;정도운
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.118-123
    • /
    • 2011
  • Heart related diseases mainly caused by heavy work load and increasing stress in human daily life. Therefore, researches on mobile healthcare monitoring for daily life has been carried out. Notably, wearable healthcare monitoring system which has least restriction has been tried to provide an emergency alert of abnormal heart rate. In this study, we developed chair type unconstrained BCG measurement system which able to perform continuous heart status monitoring at the office and daily life in the unconstrained way. Furthermore, adaptive threshold is used to detect the heart rate from BCG signals. The HRV(heart rate variability) is calculated from heart rate interval. ECG signal measured using conventional method and BCG signal measured using unconstraint system are carried out simultaneously for the purpose of performance evaluation. From the comparison result, BCG signal shows a similar heart beat characteristic as ECG signal. This proves the possibility of practical implementation of unconstraint healthcare monitoring system. In addition, medical examination like valsalva maneuver is performed to observe the changes in HRV due to stress. By performing valsalva maneuver, heart is said to be placed under an artificial physical stress condition. Under this artificial physical stress condition, the time and frequency domain of HRV parameters are evaluated.

동적 부하모델 파라미터 추정을 위한 시뮬레이션 기반 최적화 기법 비교 연구 (Comparative Study on Proposed Simulation Based Optimization Methods for Dynamic Load Model Parameter Estimation)

  • 마누엘리토 델카스텔로;송화창;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.187-188
    • /
    • 2011
  • This paper proposes the hybrid Complex-PSO algorithm based on the complex search method and particle swarm optimization (PSO) for unconstrained optimization. This hybridization intends to produce faster and more accurate convergence to the optimum value. These hybrid will concentrate on determining the dynamic load model parameters, the ZIP model and induction motor model parameters. Measurement-based parameter estimation, which employs measurement data to derive load model parameters, is used. The theoretical foundation of the measurement-based approach is system identification. The main objective of this paper is to demonstrate how the standard particle swarm optimization and complex method can be improved through hybridization of the two methods and the results will be compared with that of their original forms.

  • PDF

자유단 공시체에 있어서 압축파, 전단파, 휨파의 공진특성 (Resonances of Unconstrained Compressive, Shear and Flexural Waves in Free-Free Cylinder Specimens)

  • 박병선;조성호;이상헌;강태호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.582-589
    • /
    • 2006
  • Shear wane velocity is important property for grasping the dynamic characteristics of material. It is has been used in various fields such as non-destructive testings of structures, seismic analysis of geotechnical structures and maintenance of concrete structure, and etc. Usually, shear wave velocities of rock cores and concrete cylinders are determined by free-free resonance tests, Shear wave measurement in free-free resonance tests is not straightforward, as compared with rod wave and flexural wane measurements. In This study, a new technique using resonance features of flexural and shear waves were proposed in which the nodal points for the fundamental mode of flexural waves were employed to generate and measure the shear waves with the flexural waves minimized. The real measurements for aluminum cylinders proved validity and reliability of the proposed algorithm. In addition to the proposed algorithm, the effects of material properties on elastic-wave velocities in resonance measurements were also studied. In summary, a new framework of the resonance measurements for shear-wave velocity determination was established, based on the results of this thesis.

  • PDF

무구속적 맥파 전달 시간의 측정을 통한 혈압 추정 (Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure)

  • 지영준;박광석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

도플러 레이더와 에어 매트리스를 이용한 무구속 방식의 신생아 감시 장치 설계 (Design of Unconstrained Baby Monitoring System Based on a Doppler Radar and an Air Mattress)

  • 양성수;조성필;박호동;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.177-184
    • /
    • 2014
  • Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important since the abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoring system based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratory signals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluated using a commercialized infant simulator ($Simbaby^{TM}$) and a respiration belt transducer was used to measure respiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between I-and Q-channel and the respiration belt were 0.84 and 0.91 and the mean ${\pm}$ standard deviations of errors between them were $1.66{\pm}1.92$ (bpm) and $0.88{\pm}1.65$ (bpm). Heart rates showed that the correlation coefficient between air mattress and set value of the simulator was 0.73 and the mean ${\pm}$ standard deviation of errors between them was $1.09{\pm}3.45$ (bpm). These results indicate that the designed system holds the potential as an effective monitoring tool for continuous monitoring heart rates and respiratory rates of newborns or infants.

에어쿠션 및 주파수 영역 필터를 이용한 호흡 및 심박 신호 검출 (Detection of Heartbeat and Respiration Signal Using the Aircushion and the Frequency Domain Filter)

  • 김주한;조성필;신재연;이전;이경중
    • 전자공학회논문지SC
    • /
    • 제47권5호
    • /
    • pp.33-42
    • /
    • 2010
  • 본 연구에서는 주기적인 심장 박동과 호흡으로 인해 발생하는 인체의 미세한 변위를 기반으로 심폐활동을 모니터링 하는 방법을 제안하였다. 제안한 시스템은 에어쿠션과 센싱 하드웨어 및 신호처리 알고리즘으로 구성되어 있다. 에어쿠션은 피부의 표면에 센서의 부착없이 무구속적으로 심박과 호흡을 측정하는데 사용되며 에어쿠션 위에 피험자가 앉았을 때 쿠션내부에 작은 압력변화를 일으킨다. 에어쿠션 내부의 미세한 압력변화는 압력센서에 의해 전기적인 신호로 변환되고 아날로그 하드웨어에 의해 증폭되고 필터링 되어 출력된다. 압력센서에서 발생한 신호는 주파수 영역필터에 의해 심박과 호흡으로 분리되어 추출된다. 에어쿠션의 계측 성능을 평가하기 위해 기존의 계측방법인 심전도와 호흡신호를 동시에 측정 후 비교하였다. 에어쿠션을 이용한 호흡 및 심박 검출률의 평균 민감도는 각각 98.67%, 99.24% 이다. 이 결과를 통해 에어쿠션을 이용한 심폐 활동 측정 방법은 설치 과정이 간단하고 쉬우며 일상생활에서 무구속적으로 호흡 및 심박을 모니터링 하는데 사용할 수 있음을 알 수 있었다.