• Title/Summary/Keyword: Uncompensated

Search Result 52, Processing Time 0.026 seconds

DETECTING AND CORRECTING UNBALANCE IN TOOLHOLDERS

  • Layne, Michael H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.35-49
    • /
    • 2000
  • Over the past ten years we have wethnessed a revolution in metalcutting in the field of High Speed Machining. As machining speeds continue to increase, particularly spindle RPM, forces created by unbalance in the spindle, cutting tool, and toolholder require close attaention. It has been observed that these forces, if left uncompensated, can results in poor surface finish, loss of tool life, and spindle bearing failure. The sources of this unbalance needs to be identified and elimated in order to create a smooth, vibration free condition and allow the machine tool and its spindle to operate properly.

  • PDF

Structure and Magnetic Properties of Cr2O3/CrO2 Nanoparticles Prepared by Reactive Laser Ablation and Oxidation under High Pressure of Oxygen

  • Si, P.Z.;Wang, X.L.;Xiao, X.F.;Chen, H.J.;Liu, X.Y.;Jiang, L.;Liu, J.J.;Jiao, Z.W.;Ge, H.L.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.211-214
    • /
    • 2015
  • $Cr_2O_3$ nanoparticles were prepared via one-step reactive laser ablation of Cr in oxygen. The metastable $CrO_2$ phase was obtained through the subsequent oxidation of $Cr_2O_3$ nanoparticles under $O_2$ with gas pressures of up to 40 MPa. The as-prepared $Cr_2O_3$ nanoparticles are spherical or rectangular in shape with sizes ranging from 20 nm to 50 nm. High oxygen pressure annealing is effective in producing meta-stable $CrO_2$ from as-dried $Cr_2O_3$ nanoparticles, and the $Cr_2O_3$ nanoparticles exhibit a weak ferromagnetic behavior with an exchange bias of up to 11 mT that can be ascribed to the interfacial exchange coupling between uncompensated surface spins and the antiferromagnetic core. The $Cr_2O_3/CrO_2$ nanoparticles exhibit an enhanced saturation magnetization and a reduced exchange bias with an increasing faction of $CrO_2$ due to the elimination of uncompensated surface spins over the $Cr_2O_3$ nanoparticles when exposed to a high pressure of $O_2$ and/or possible phase segregation that results in a smaller grain size for both $Cr_2O_3$ and $CrO_2$.

Measurement and Compensation of Respiration-Induced B0 Variations in Lumbar Spine Bone Marrow Fat Quantification

  • Nam, Yoonho;Hwang, Eojin;Jung, Joon-Yong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.28-33
    • /
    • 2017
  • Purpose: To investigate and compensate the effects of respiration-induced B0 variations on fat quantification of the bone marrow in the lumbar spine. Materials and Methods: Multi-echo gradient echo images with navigator echoes were obtained from eight healthy volunteers at 3T clinical scanner. Using navigator echo data, respiration-induced B0 variations were measured and compensated. Fat fraction maps were estimated using $T2^*$-IDEAL algorithm from the uncompensated and compensated images. For manually drawn bone marrow regions, the estimated B0 variations and the calculated fat fractions (before and after compensations) were analyzed. Results: An increase of temporal B0 variations from inferior level to superior levels was observed for all subjects. After compensation using navigator echo data, the effects of the B0 variations were reduced in gradient echo images. The calculated fat fractions show significant differences (P < 0.05) in L1 and L3 between the uncompensated and the compensated. Conclusion: The results of this study raise the need for considering respiration-induced B0 variations for accurate fat quantification using gradient echo images in the lumbar spine. The use of navigator echo data can be an effective way for the reduction of the effects of respiratory motion on the quantification.

Clinical Review about Dysphagia associated with Acute Ischemic Stroke (급성 허혈성 뇌졸중에 수반된 연하장애에 관한 임상적 고찰)

  • 한명아;김동웅
    • The Journal of Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.42-50
    • /
    • 2001
  • Objectives : Dysphagia is common and severe problems of acute stroke determining the prognosis of stroke only second to mental change, and results in secondary fatal complications such as aspiration pneumonia, malnutrition, dehydration, etc. Therefore, we were to investigate the clinical characteristics of dysphagia accompanied by acute ischemic stroke. Methods : We selected subjects through clinical notes retrospectively, whose main problems included dysphagia resulted from acute stroke within 72 hours from onset who were admitted to the Internal Medicine Department of Wonkwang Oriental Medicine Hospital from Jan. 2000 to Apr. 2001. We assessed the severity of dysphagia from admission to discharge using a staging method : stage 0 is normal without dysphagia, stage 1 is nearly normal except for intermittent dysphagia, stage 2 is compensated abnormal swallowing requiring adjusted diets or delayed feeding time, stage 3 is uncompensated abnormal swallowing resulted in weight loss down to 10% of initial and daily aspiration, coughing, and vomiting, stage 4 is uncompensated abnormal swallowing resulting in weight loss beyond 10% and recommended for non-oral feeding, and stage 5 is 100% non-oral feeding by L-tube, or gastrostomy or NPO state. Results : Dysphagia was improved statistically significantly from the mean stage of $3.6{\pm}0.29$ on admission to $1.88{\pm}0.32$ on discharge (P<0.05). On average $7.1{\pm}1.48$ days were required for improving more than one stage level. As patients were older and the stage of dysphagia was worse on admission, severity of dysphagia was more difficult to improve (correlation coefficiency was 0.55 and 0.77 respectively, P<0.05). Aspiration pneumonia was complicated in 13 patients of the total 25 at mean dysphagia stage of $3.36{\pm}0.37$. However, any specific values such as lesion size, lesion site, sex, age, past history and NIH Stroke Scale on admission did not affect it (P>0.05). Conclusion : Clinical course of dysphagia was determined about I week from the onset. Aspiration pneumonia was mainly complicated during oral feeding periods. If there were no improvement of dysphagia over 2-3 weeks, then non-oral feeding such as Levin tube or gastrostomy must be considered.

  • PDF

Vibration Suppression Control for a Twin-Drive Geared Mechanical System with Backlash: Effects of Model-Based Control

  • Itoh, Masahiko
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1392-1397
    • /
    • 2003
  • This paper deals with a control technique of eliminating the transient vibration of a twin-drive geared mechanical system. This technique is based on a model-based control in order to establish the damping effect at the driven machine part. The control model is composed of reduced-order electrical and mechanical parts. This control model estimates a load speed converted to the motor shaft. The difference between the estimated load speed and the motor speed is calculated dynamically and it is added to the velocity command to suppress the transient vibration generated at the load. This control technique is applied to a twin-drive geared system with backlash. In the previous work, the performance of this control method is examined by simulations. In this paper, the effectiveness of this control technique is verified by experiments. The settling time of the residual vibration generated at the loading inertia can be shortened down to about 1/2 of the uncompensated vibration level.

  • PDF

The estimation of first order derivative phase error using iterative algorithm in SAR imaging system (SAR(Synthetic Aperture Radar)Imaging 시스템에서 제안 알고리즘의 반복수행을 통한 위상오차의 기울기 추정기법 연구)

  • 김형주;최정희
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.505-508
    • /
    • 2000
  • The success of target reconstruction in SAR(Synthetic Aperture Radar) imaging system is greatly dependent on the coherent detection. Primary causes of incoherent detection are uncompensated target or sensor motion, random turbulence in propagation media, wrong path in radar platform, and etc. And these appear as multiplicative phase error to the echoed signal, which consequently, causes fatal degradations such as fading or dislocation of target image. In this paper, we present iterative phase error estimation scheme which uses echoed data in all temporal frequencies. We started with analyzing wave equation for one point target and extend to overall echoed data from the target scene - The two wave equations governing the SAR signal at two temporal frequencies of the radar signal are combined to derive a method to reconstruct the complex phase error function. Eventually, this operation attains phase error correction algorithm from the total received SAR signal. We verify the success of the proposed algorithm by applying it to the simulated spotlight-mode SAR data.

  • PDF

Efficacy and Safety of Ziprasidone (지프라시돈의 효능 및 안전성)

  • Yu, Bong G.
    • Korean Journal of Clinical Pharmacy
    • /
    • v.11 no.2
    • /
    • pp.89-96
    • /
    • 2001
  • Ziprasidone is equally effective as haloperidol in treating schizophrenia with fewer side effects and drug interactions. Ziprasidone is an atypical antipsychotic agent and works by blocking serotonin and dopamine receptors in the central nervous system, specifically 5-HT2A and D2 receptors. Low anticholinergic side-effects and low EPS would recommend the drug for use in the elderly. Ziprasidone inhibits reuptake of norepinephrine and serotonin at neurojunction sites in vitro, indicating a potential efficacy for depression and negative symptoms which often follow after exacerbation of schizophrenia. Patients with recent acute myocardial infarction and uncompensated heart failure are contraindicated to the drug due to a possibility of QT prolongation. Although ziprasidone is metabolized by cytochrome P450 3A4, there is no significant drug interaction with the drugs that induce or inhibit the isoenzyme. Ziprasidone is safe with coadministration of lithium and there has been no significant drug interaction reported with oral birth control pills.

  • PDF

Bandwidth Improvement of a Multi-resonant Broadband Acoustic Transducer (다중 공진 광대역 음향변환기의 대역폭 개선)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.5
    • /
    • pp.605-615
    • /
    • 2017
  • A multi-resonant broadband acoustic transducer with six Tonpilz elements operating at different resonant frequencies in a transducer assembly was fabricated, tested, and analyzed. A compensated transducer, modified by adding series inductance to the developed multi-resonant broadband transducer, was shown to provide improved bandwidth performance with a relatively more uniform frequency response compared with the uncompensated transducer. By controlling the series inductance, flat frequency response characteristics at two frequency bands were obtained over the range 38-52 kHz with 1.1 mH inductance and 50-60 kHz with 0.4 mH inductance. These results suggest that the operating frequency of the developed multi-resonant broadband transducer in a chirp echo sounder can be shifted to a different frequency band that is optimized according to the environment for more effective echo surveys of fishing grounds.