• Title/Summary/Keyword: Uncertain Plant

Search Result 150, Processing Time 0.024 seconds

Robust process fault diagnosis with uncertain data

  • Lee, Gi-Baek;Mo, Kyung-Joo;Yoon, En-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.283-286
    • /
    • 1996
  • This study suggests a new methodology for the fault diagnosis based on the signed digraph in developing the fault diagnosis system of a boiler plant. The suggested methodology uses the new model, fault-effect tree. The SDG has the advantage, which is simple and graphical to represent the causal relationship between process variables, and therefore is easy to understand. However, it cannot handle the broken path cases arisen from data uncertainty as it assumes consistent path. The FET is based on the SDG to utilize the advantages of the SDG, and also covers the above problem. The proposed FET model is constructed by clustering of measured variables, decomposing knowledge base and searching the fault propagation path from the possible faults. The search is performed automatically. The fault diagnosis system for a boiler plant, ENDS was constructed using the expert system shell G2 and the advantages of the presented method were confirmed through case studies.

  • PDF

Repetitive Control for the Track-Following Servo System of an Optical Disk Drive (광 디스크 드라이브의 트랙 추종 서보 시스템을 위한 반복 제어)

  • 문정호;이문노;정명진
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.1
    • /
    • pp.39-46
    • /
    • 1999
  • Disturbances acting on the track-following servo system of an optical disk drive inherently contain significant periodic components that cause tracking errors of a periodic nature. Such disturbances can be effectively rejected by employing a repetitive controller, which must be implemented carefully in consideration of system stability. Plant uncertainty makes it difficult to design a repetitive controller that will improve tracking performance yet preserve system stability. In this paper, we examine the problem of designing a repetitive controller for an optical disk drive track-following servo system with uncertain plant coefficients. We propose a graphical design technique based on the frequency domain analysis of linear interval systems. This design method results in a repetitive controller that will maintain system stability against all admissible plant uncertainties. We show simulation and experimental results to verify the validity of the proposed design method.

  • PDF

A robust controller design for attitude control of hovering vehicle (수직부상기의 자세제어를 위한 강인한 제어기의 설계)

  • 최연욱;이형기
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.12
    • /
    • pp.41-49
    • /
    • 1997
  • This paper deals with the attitude control of a self-made VTOL vehicle which is round shape and has four fans and motors. Although hovering mechanisms are suitable for field work at a mountainous region or a building site etc., it is known that modeling the structure of the plant is quite difficult due to its unstable or uncertain characteristics. So, a robust controller is requried in order to cope with these uncertainties. WE first model the structure of the plant under the actual hovering setting and then determine the uncertainty of the acquired mathematical model by using system identification method as exactly as possible. We adopt the $H^{\infty}$ theory as a control algorithm because of its availability, and the structure of two-degree-of-freedom is used as a basic feedback control system to improve the transient response of the plant. Finally, we show the appropriateness of the designed controller through simulations and experiments. That is, the proposed VTOL system is able to maintain its roubust performance in spite of parameter variations and existing disturbances..

  • PDF

Design of an adaptive fuzzy model predictive controller for combustion control of refuse incineration plant (쓰레기 소각로의 효율적인 연소제어를 위한 적응 퍼지모델 예측제어기 설계)

  • 박종진;강신준;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.134-138
    • /
    • 1996
  • Refuse incineration plant operations involve many kinds of uncertain factors, such as the variable physical properties of refuse as fuel and the complexity of the burning phenomenon. That makes it very difficult apply conventional control methods to the combustion control of the refuse. In this paper, an adaptive fuzzy model predictive controller is proposed for the combustion control of the refuse. In this paper, an adaptive fuzzy model predictive controller is proposed for the combustion control of the refuse. And computer simulation was carried out to evaluate performance of the proposed controller.

  • PDF

Indirect adaptive nonlinear control for power system stabilization (전력계통안정화를 위한 간접적응 비선형제어)

  • 이도관;윤태웅;이병준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.454-457
    • /
    • 1997
  • As in most industrial processes, the dynamic characteristics of an electric power system are subject to changes. Amongst those effects which cause the system to be uncertain, faults on transmission lines are considered. For the stabilization of the power system, we present an indirect adaptive control method, which is capable of tracking a sudden change in the effective reactance of a transmission line. As the plant dynamics are nonlinear, an input-output feedback linearization method equipped with nonlinear damping terms is combined with an identification algorithm which estimates the effect of a fault. The stability of the resulting adaptive nonlinear system is investigated.

  • PDF

On-Line Parameter Estimation Scheme for Uncertain Takagi-Sugeno Fuzzy Models

  • Cho, Young-Wan;Park, Chang-Woo
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.1
    • /
    • pp.68-75
    • /
    • 2004
  • In this paper, an estimator with an appropriate adaptive law for updating parameters is designed and analyzed based on the Lyapunov theory. The adaptive law is designed so that the estimation model follows the parameterized plant model. Using the proposed estimator, the parameters of the T-S fuzzy model can be estimated by observing the behavior of the system and it can be a basis for indirect adaptive fuzzy control.

Computational solution for the problem of a stochastic optimal switching control

  • Choi, Won-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.155-159
    • /
    • 1993
  • In this paper, we consider the problem of a stochastic optimal switching control, which can be applied to the control of a system with uncertain demand such as a control problem of a power plant. The dynamic programming method is applied for the formulation of the optimal control problem. We solve the system of Quasi-Variational Inequalities(QVI) using an algoritlim which involves the finite difference approximation and contraction mapping method. A mathematical example of the optimal switching control is constructed. The actual performance of the algorithm is also tested through the solution of the constructed example.

  • PDF

Robust Controller Design for System with Uncertain Parameter (불확실한 파라메터를 갖고있는 시스템의 제어기 설계)

  • Park, Yong-Sik;Yeom, Jai-Myeong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.636-638
    • /
    • 1997
  • This paper deals with the problem of finding robust controller based upon a pole assignment method for a plant with parameter perturbations. This case is not a problem of Interval polynomial family but a problem of poly topic polynomial family. As a method of stability test, we used GKT(Generalized Kharitonov Theorem) having computational advantage.

  • PDF

Power system stabilization via adaptive feedback linearization (비선형 적응제어를 이용한 전력계통 안정화)

  • 윤태웅;이도관
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1221-1224
    • /
    • 1996
  • As in most industrial processes, the dynamic characteristics of an electric power system are subject to changes. Amongst those effects which cause the system to be uncertain, faults on transmission lines are considered. For the stabilization of the power system, we present an indirect adaptive control method, which is capable of tracking a sudden change in the effective reactance of a transmission line. As the plant dynamics are nonlinear, an input-output feedback linearization method is combined with an identification algorithm which estimates the effect of a fault.

  • PDF

Two-stage robust model following control of robot manipulators

  • Osuka, Koichi;Sugie, Toshiharu;Ono, Toshiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.876-881
    • /
    • 1987
  • This paper is concerned with a robust model following control scheme for manipulators which contains uncertain terms. Our method consists of nonlinear compensation and linear compensation. The former ensures the robustness of the plant, the later achieves both the desired model following response and the desired initial error convergence.

  • PDF