• Title/Summary/Keyword: Ultrasound power

Search Result 194, Processing Time 0.025 seconds

Zizyphus jujube-based Edible Film Development by the Depolymerization Processes (고분자 분쇄 공정을 이용한 대추 소재 가식성 필름 개발)

  • Lee, Hahn-Bit;Yang, Hee-Jae;Ahn, Jun-Bae;Lee, Youn-Suk;Min, Sea-C.
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.3
    • /
    • pp.321-328
    • /
    • 2011
  • Edible films were developed from jujube (Zizyphus jujube Miller) using depolymerization processes of ultrasound and high-pressure homogenization. A 4.6% (w/w) jujube hydrocolloid was treated by ultrasound (600W, 20 min) or homogenized at high pressure (172 MPa, 6 s) and mixed with whey protein isolate, glycerol, xanthan, and sucrose esters of fatty acids to form film-forming solutions from which films were formed by drying. The film prepared by highpressure homogenization (HPH film) produced more homogeneous films without particles than those prepared without depolymerization or with the ultrasound treatment. HPH films possessed the highest tensile strength (4.7MPa), the lowest water vapor permeability ($2.9g{\cdot}mm/kPa{\cdot}h{\cdot}m^2$), and the most uniform and dense microstructures among the films. Flavor profiles of jujube powder and the films were distinguishable. Heat seal strength and oxygen permeability of the HPH films were 44.4 N/m and $0.025mL{\cdot}{\mu}m/m^2$/day/Pa, respectively. Antioxidant activities of jujube power and HPH films were not significantly different.

Clinical Observation on Heart Rate Variability and Peripheral Blood Flow by Doppler Ultrasound in Healthy Subjects Stimulated by Cold Stress (정상인의 한냉자극에 대한 심박변이도 및 도플러 초음파 혈류계를 이용한 말초 혈류관찰)

  • Lim, Sung-Keun;Lee, Sang-Hoon;Bae, Young-Min
    • The Journal of Korean Medicine
    • /
    • v.31 no.2
    • /
    • pp.114-123
    • /
    • 2010
  • Objectives: This study was performed to investigate the effect of cold stress on heart rate variability and peripheral blood flow by Doppler ultrasound in healthy subjects. Methods: We classified the subjects by their Yin or Yang tendency using a Yin-Yang questionnaire. Cold stress was taken on the left hand of subjects for 10 seconds. Heart rate variability and peripheral blood flow were measured on the right radial artery before and after cold stress. Results: The Yang tendency group showed a significant decrease of heart rate after cold stress which was not seen in the Yin tendency group. The Yang tendency group showed a decrease of LF, total power, and increase of HF after cold stress, while the Yin tendency group showed the opposite. However, there were no statistically significant differences of heart rate variability analysis between the results of the two groups before and after cold stress. Recovery time of blood flow velocity by ultrasound Doppler was significantly different between the Yin and Yang tendency groups after cold stress. Conclusion: These results suggest that people with Yin or Yang tendency may show different responses in the autonomic nervous system. Further modified studies may include the responses to various manipulation techniques in acupuncture treatment and the individual responses according to pattern identification in traditional Korean medicine.

A Reconfigurable Analog Front-end Integrated Circuit for Medical Ultrasound Imaging Systems (초음파 의료 영상 시스템을 위한 재구성 가능한 아날로그 집적회로)

  • Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.66-71
    • /
    • 2014
  • This paper presents an analog front-end integrated circuit (IC) for medical ultrasound imaging systems using standard $0.18-{\mu}m$ CMOS process. The proposed front-end circuit includes the transmit part which consists of 15-V high-voltage pulser operating at 2.6 MHz, and the receive part which consists of switch and a low-power low-noise preamplifier. Depending on the operation mode, the output driver in the transmit pulser can be reconfigured as the switch in the receive path and thus the area of the overall front-end IC is reduced by over 70% in comparison to previous work. The designed single-channel front-end prototype consumes less than $0.045mm^2$ of core area and can be utilized as a key building block in highly-integrated multi-array ultrasound medical imaging systems.

Effects of Continuous Therapeutic Ultrasound on Subcutaneous Murine Melanoma (초음파치료가 종양세포에 미치는 효과)

  • Kim, Ji-Won;Lee, Kuk-Il;Han, Jae-Mun
    • Physical Therapy Korea
    • /
    • v.4 no.1
    • /
    • pp.11-19
    • /
    • 1997
  • The use of therapeutic ultrasound(US) in humans with malignant neoplasms has been contraindicated in physical therapy practice. Some studies have shown that results after application of US differ according to tumor type and penetration depth. The purposes of this study were to determine the effects of US on melanoma in mice and to determine treatment dosage. Twenty-four female C57BL/6 mice, age 8 weeks. The right flank of all mice was shaved, and a 0.1 ml suspension of cells was injected subcutaneously into the animals' right flank. In this study, 24 subjects were randomly divided into three groups: experimental group 1(n=8), experimental group 2(n=8), control group(n=8). In the experimental group 1, animals received continuous 3 MHZ US treatment, administered at $2.0W/cm^2$ for five minutes. In experimental group 2, animals received continuous 3 MHz US treatment, administered at $1.0W/cm^2$ for 5 minutes. The control group received the same handling as other experimental groups, including rodent chow, water, US gel application but US head pressure without the power turned on. After 10 days treatment, all mice were killed with a potassium solution. Tumors were excised and weighed on an electrical balance and fixed in a 10% neutral buffered formalin solution. Tumor weights were smaller in experimental group 2(0.3838 g) than in the control group(0.6275 g). Tumor weights of the experimental group 1(0.015 g) were smaller than those of experimental group 2. Continuous therapeutic US decreased the weight of subcutaneous melanoma tumors in mice. The treatment dosage($2.0W/cm^2$) we suggest was more effective than earlier studies on decreasing tumor size with ultrasound.

  • PDF

Positioning using ZigBee and Ultrasound

  • Park, Chan-Sik;Kim, Seung-Beom;Kang, Dong-Youn;Yun, Hee-Hak;Cha, En-Jong;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.217-222
    • /
    • 2006
  • To find a location, GPS has been wildly used. But, it is hard to use in indoor because of very weak signal level. To meet indoor requirements, there have been many studies applying wireless communication networks such as WLAN, UWB and ZigBee. Among these, ZigBee is widely adopted in many WSN applications because it has an advantage of low-power and low-cost. In ZigBee, the RSSI is used as range measurement for ad-hoc network. The RSSI are converted to ranges using the signal attenuation model and these ranges become inputs of positioning methods. The obtained position with RSSI has large error because of its poor accuracy. To overcome this problem, ultrasonic sensors are added in many researches. By measuring the arrival time difference of ZigBee and ultrasound as a range measurement, the precise position can be found. However, there are still many problems: scheduling of beacons to transmit signals in a correct order, addition and synchronization of beacons and low-rate positioning rate. At this paper, an efficient method to solve these problems is proposed. In the proposed method, a node transmits ZigBee and ultrasound signal simultaneously. And beacons find the range with the received signals and send it back to a node with ZigBee. The position is computed in a node with the received ranges. In addition, a new positioning algorithm to solve the risk of the divergence in the linearization method and the singularity problem in the Savarese method is presented. Both static and dynamic experimental results show 0.02m RMS errors with high output rate.

  • PDF

Cell Disruption of Dunaliella salina using Batch Low Frequency Non-Focused Ultrasound (비집속 회분저주파를 이용한 Dunaliella salina 세포 파쇄)

  • Choi, Jun-Hyuk;Kim, Gwang-Ho;Park, Jong-Rak;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.63-71
    • /
    • 2021
  • Using fossil fuels in existing industrial systems causes a variety of social problems. Recently, many studies have been conducted on bio-refineries, which aim to actively utilize biomass to reduce the use of fossil fuels and solve various social problems. Among them, research using microalgae as a third-generation biomass has attracted considerable attention. Microalgae use inorganic matter to produce organic matter, and cell destruction is necessary to extract useful organic materials from microalgae. The extracted organic materials are currently used in various industrial fields. Numerous cell-destruction methods exist. We have investigated cell disruption by sonication, especially its efficiency. Ultrasound is a sound wave with frequencies above 20 kHz, and destroys cells by sending high energy through a cavitation that occurs, according to the characteristics of the sound wave. The Dunaliella salina microalgae used in this study was cultured in a flat-type photobioreactor. Experiments were performed using a batch low-frequency processing device. Logistic model was applied to analyze the results of cell-destruction experiments using ultrasound. The proper conditions for the most efficient cell destruction were OD 1.4(microalgae concentration)), 54watt(output power) and 200mL(microalgae capacity).

Characteristics of deodorization for malodorants in aqueous solution by sonication

  • Yoo, Young-Eok;Maeda, Yasuaki
    • Journal of Environmental Science International
    • /
    • v.13 no.2
    • /
    • pp.167-173
    • /
    • 2004
  • A aqueous solution of malodorants (i.e., n-valeraldehyde, n-valeric- acid, 2-methylisoborneol, and trimethylamine) was exposed to 200KHz ultrasound with a power of 6.0W/$\textrm{cm}^2$ per unit volume in a sonochemical reactor under room temperature and atmospheric pressure condition. The concentration of malodorants decreased with irradiation time, indicating pseudo-first-order kinetics. The removal efficiency of malodorants was about from 50% to 96% decomposed after 90 minutes sonication. At the deodorization, it was determined by triangle odor bag(TOB) method for odor sensory measurement, and it indicated that over 60% of relative odors were deodorized with degradation by the sonication.

Ultrasound Imaging Based On Simultaneous Multiple Transmit Focusing Using Orthogonal Modified Golay Code (직교하는 변형된 골레이(Golay) 코드를 이용한 동시 다중 집속 기반의 초음파 영상 기법)

  • Kim, B.H.;Jeong, Y.K.;Song, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.187-190
    • /
    • 2001
  • A new ultrasound imaging technique based on simultaneous multiple transmit focusing using orthogonal modified Golay codes is presented. modified Golay codes are used to increase signal-to-noise-ratio(SNR) and maximize the transmit power efficiency(TPE). Conventional Golay codes consist of a pair of complementary codes with same length and can be compressed into a delta-like signal due to their complementary property. In the present work, two modified Golay codes focused at different depths are transmitted at the same time, which are mutually orthogonal. On receive, these orthogonal modified Golay codes are separately compressed into two short pulses and individually focused. These two focused beam are combined to form a frame of image with improved lateral resolution. Computer simulations are performed to verity the proposed method improves the lateral resolution of image compared with the conventional echo system.

  • PDF

NiZn Ferrite Coating for Electrical Insulation of MnZn Ferrite Cores

  • Kitamoto, Y.;Yajima, H.;Nakayama, Y.;Abe, M.
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.6
    • /
    • pp.506-508
    • /
    • 2001
  • The ferrite plating with applying power ultrasound waves of 19.5 kHz and 600W enabled us to encapsulate entirely MnZn ferrite cores for transformers with Ni$\sub$x/Zn$\sub$y/Fe$\sub$3-x-y/O$_4$coating. Supplying a NH$_4$OH solution during the plating broke the limit of the solubility of Ni ions to ferrite-plated films. The electrical resistivity of the NiZn ferrite coating increased with increasing the Ni and Zn content, reaching 2.3${\times}$10$\^$5/Ωcm at the composition of Ni$\sub$0.24/Zn$\sub$0.30/Fe$\sub$2.46/O$_4$. The saturation magnetization was 540 emu/㎤. As a result, the MnZn ferrite cores were successfully encapsulated with the NiZn ferrite coatings for an insulation layer.

  • PDF

Application of Ultrasounds for the Removal of Chlorobenzene and Chlorinated Phenols in Water (Chlorobenzene 및 Chlorinated Phenol류의 분해에 미치는 초음파의 응용)

  • 우영억;황규탁
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.35-43
    • /
    • 2000
  • Aqueous solutions of chlorobenzene and chlorinated phenols were exposed to 200kHz ultrasound with a power of $6.0W/\textrm{cm}^2$ per unit volume on sonochemical reactor under ambient temperature and pressure conditions. The concentration of chlorobenzene and chlorinated phenols decreased with ultrasound, indicating first-order kinetics. Degradation rate constants are calculated from the slope of plots. The order of the rate constants is as follows : 2-chlorphenol(2-CP)$\leq$ 4-chlorophenol(4-CP)<3-chlorophenol(3-CP)$5.63~9.96({\times}10^{-2})min^{-1}$ under argon. The degradation was suppressed by the addition of t-BuOH and the suppressed yield was agreed with their reactivity for hydroxy radical. The main products of these systems were formic acid, acetic acid, small amount of methane and inorganic carbon forms as carbon dioxide, carbon monoxide in sonolysis of chlorinated phenols, and also these results agreed with change of TOC.

  • PDF