• Title/Summary/Keyword: Ultrasound power

Search Result 194, Processing Time 0.023 seconds

Analysis on Code Used in Pulse Compression Method for Improving Resolution of Ultrasound Imaging System (초음파 영상 시스템에서의 해상도 개선을 위한 펄스압축기법에 사용되는 코드에 대한 분석)

  • You, Y.M.;Lee, H.H.;Song, T.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.115-116
    • /
    • 1998
  • Pulse echo techniques have been used for the conventional medical ultrasound imaging systems. However, their resolution is limited in the transmitted signal power. To overcome this limit, pulse compression method used in the radar systems was proposed. This system transmits a continuous coded signal and then compresses the received signal into the short and high resolution pulse by using correlator. The reflectors can be detected by cross-correlation between the transmitted signal and the received signal with the depth information. In this paper, we will present a comparative study of the performances of the most common sequences(pseudo-chirp, m-sequences, modified Golay code). The best result for improving resolution is obtained with the modified Golay Code.

  • PDF

Ultrasonically Enhanced Dewaterability of Fine Particles (초미립자 탈수성 증대를 위한 초음파 활용에 관한 연구)

  • Oh, Chul;Kim, Byoung-Il;Kim, Young-Uk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.313-320
    • /
    • 2002
  • In accordance with the need of developing a methodology for the sludge reduction, this study investigates the effect of sonication on the dewaterability of the sewage sludge. The investigation involves laboratory experiments of the sewage sludge from Yongin Waste Treatment Plant. The Laboratory tests were conducted under a broad range of conditions including energy levels of ultrasonic waves, time for the treatment, pH, and effect of polymers. The results of the study show that sonication enhances the dewaterability significantly The degree of enhancement varies with sonication power, treatment time, the amount of sludge treated. The effect of sonication on the temperature and pH of the test specimens seems not to be significant. The polymer can be useful to enhance the effectiveness of ultrasound treatment.

  • PDF

In-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement system

  • Dib, Gerges;Roy, Surajit;Ramuhalli, Pradeep;Chai, Jangbom
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.867-876
    • /
    • 2019
  • Second harmonic generation using nonlinear ultrasonic waves have been shown to be an early indicator of possible fatigue damage in nuclear power plant components. This technique relies on measuring amplitudes, making it highly susceptible to variations in transducer coupling and instrumentation. This paper proposes an experimental procedure for in-situ surface wave nonlinear ultrasound measurements on specimen with permanently mounted transducers under high cycle fatigue loading without interrupting the experiment. It allows continuous monitoring and minimizes variation due to transducer coupling. Moreover, relations describing the effects of the measurement system nonlinearity including the effects of the material transfer function on the measured nonlinearity parameter are derived. An in-situ high cycle fatigue test was conducted using two 304 stainless steel specimens with two different excitation frequencies. A comprehensive analysis of the nonlinear sources, which result in variations in the measured nonlinearity parameters, was performed and the effects of the system nonlinearities are explained and identified. In both specimens, monotonic trend was observed in nonlinear parameter when the value of fundamental amplitude was not changing.

Diagnosis of Micro-Calcified Lesions of Breast Tissue Phantoms Using Acoustic Resonance Coupled with Power Doppler (공명현상과 파워도플러를 이용한 유방조직 팬텀의 미세 석회화 병변 진단)

  • Kim, Jeong-Koo;Ha, Myeung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Breast ultrasound has many advantages over mammography but suffers from a shortcoming of being not suitable in detecting microcalcification. We studied on a method based on acoustic resonance and power Doppler to detect calcification of breast tissue using a typical 7.5 MHz linear probe used in breast ultrasound examination. We first constructed a breast tissue phantom made of gelatin and then observed calcified legions as external vibrations varied. Calcification injected to the breast tissue phantom being resonated different from the surrounding medium, and its acoustic resonance driven by external vibrations was visualized by differences for color brightness and area in ROI of power doppler. In low frequency regions, the acoustic resonance almost not appeared and showed a plateau in $300{\sim}600\;Hz$ and the color vanished as the frequency further increased.

Measurement of the Quantity of Hydrogen Peroxide Produced in the Ultrasound-irradiated Aqueous Solution of Organic Compounds (초음파를 조사(照射)한 유기화합물 수용액 속에서의 과산화수소 생성량의 측정)

  • Mo, Se-Young;Chang, Hong-Ki;Lee, Kyung-Jae;Jang, Gun-Eik;Sohn, Jong-Ryeul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.61-71
    • /
    • 2000
  • When irradiate the power ultrasound into the aqueous solutions, water vapor is decomposed by the heat of very high temperature in the cavitation bubble to produce OH (hydroxyl radical) and H (hydrogen radical), and these radicals play a role in decomposing the substances in aqueous solution by oxidation and/or reduction, and in producing the hydrogen peroxide. Accordingly it is possible to predict that the quantity of hydrogen peroxide produced may correlate with the sonolysis mechanism of the substance in aqueous solution. Thus to confirm this prediction, the quantities of hydrogen peroxide produced from each of the air saturated distilled water and three aqueous solutions of TCE, benzene, and 2,4-DCP that are prepared by dissolving them into distilled water are measured. As a result, it showed that the quantity of hydrogen peroxide produced from the distilled water and three aqueous solutions are increased in order of distilled water>TCE solution>2,4-DCP solution>benzene solution, and decrease with decrease in concentration of organic substance, which coincide with the sonolysis mechanisms reported that TCE in aqueous solution is decomposed directly by the pyrolysis in and around the cavitation bubbles when its concentration is high and by the radical reaction when low, however, benzene and 2,4-DCP are decomposed not only by the pyrolysis but also by the radical reactions. Effects of such experimental parameters as the acoustic frequency and power and as the concentration showed that the higher the acoustic frequency and the lower the acoustic power, the less the quantity of hydrogen peroxide was produced. This result coincide with the theory of ultrasound for the relation between the cavitation that is the energy source of the power ultrasound in aqueous solution and these experimental parameters.

  • PDF

Hepatic Hemangiomas: Spectrum of US Appearances on Gray-scale, Power Doppler, and Contrast-Enhanced US

  • Kyoung Won Kim;Tae Kyoung Kim;Joon Koo Han;Ah Young Kim;Hyun Ju Lee;Seong Ho Park;Young Hoon Kim;Byung Ihn Choi
    • Korean Journal of Radiology
    • /
    • v.1 no.4
    • /
    • pp.191-197
    • /
    • 2000
  • Because US plays a key role in the initial evaluation of hepatic hemangiomas, knowledge of the entire spectrum of US appearances of these tumors is important. Most hemangiomas have a distinctive US appearance, and even with those with atypical appearances on conventional gray-scale US, specific diagnoses can be made using pulse-inversion harmonic US with contrast agents. In this essay, we review the spectrum of US appearances of hepatic hemangiomas on conventional gray-scale, power Doppler, and pulse-inversion harmonic US with contrast agents.

  • PDF

Ultrasound-assisted Extraction of Total Flavonoids from Wheat Sprout: Optimization Using Central Composite Design Method (밀싹으로부터 플라보노이드성분의 초음파 추출 : 중심합성계획모델을 이용한 최적화)

  • Lee, Seung Bum;Wang, Xiaozheng;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.663-669
    • /
    • 2018
  • The process of extracting active ingredients from wheat sprout using ultrasound assisted method was optimized with a central composite design model. The response value of the central composite design model established the extraction yield and the total flavonoids content, main effects and interactive effects were analyzed depending on independent variables such as the extraction time, volume ratio of ethanol to ultrapure water, and ultrasonic irradiation power. The volume ratio of ethanol to ultrapure water and ultrasonic irradiation power were relatively large for the extraction yield and the extraction time was most significantly affected the total flavonoids, Considering both the extraction yield and total flavonoids content, the optimal extraction conditions were as follows: the extraction time of 17.00 min, volume ratio of ethanol to ultrapure water of 50.25 vol%, ultrasonic irradiation power of 551.70 W. In this case, the extraction yield and total flavonoids content were 28.43 wt% and $29.99{\mu}g\;QE/mL\;dw$, respectively. The actual experimental extraction yield and total flavonoids content under this condition were 8.73 wt% and $29.65{\mu}g\;QE/mL\;dw$, respectively with respective error rates of 1.05 and 1.13%.

Transabdominal Ultrasound Assessment of the Polycystic Ovary Syndrome (다낭난소증후군 진단시 복식 초음파의 유용성에 관한 연구)

  • Jeong, Kyung-Ah;Lee, Woon-Jeong;Chung, Hye-Won
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-263
    • /
    • 2009
  • Objective: The objective of the study was to determine the diagnostic performance of transabdominal ultrasound by receiver operating characteristic (ROC) curve analysis, in order to evaluate the usefulness in establishing the diagnosis of polycystic ovary syndrome (PCOS). Methods: Questionnaires were given to 8,793 reproductive women reviewed at Ewha Womans University Mokdong hospital. Ultrasound examinations were performed in 701 women with a transabdominal transducer. Transabdominal ultrasounds were performed in 185 normal control women (normal menstruation without hyperandrogenism or PCO morphology) and 248 PCOS patients according to National Institutes of Health (NIH) PCOS diagnosis criteria. ROC curves were calculated for ovarian volume and follicle number. Results: In normal control group, the mean age were $23.64{\pm}4.26$ years old and the mean ovarian volume and follicle number were $6.03{\pm}1.89\;cm^3$ and $6.49{\pm}1.93$, respectively. The ovarian volume showed an area under the ROC curve (AURC) of 0.761. A ovarian volume decision threshold >$9\;cm^3$ had a sensitivity of 51.0% and a specificity of 91.4% for the diagnosis of PCOS. The follicle number showed an AURC of 0.733. A follicle number decision threshold ${\geq}9$ had a sensitivity of 54.9% and a specificity of 87.0% for the diagnosis of PCOS. A follicle number decision threshold ${\geq}10$ had a sensitivity of 53.2% and a specificity of 90.4%. A follicle number and a ovarian volume did not have a high diagnostic power for screening for PCOS. Conclusion: Our results suggest that transabdominal ultrasound assessment is not effective for the detection of PCOS in young women of reproductive age.

Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia (강내온열 치료를 위한 원통형 초음파 치료기 개발)

  • Lee, Rena J.;Hyunsuk Suh
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • In this study, a cylindrical ultrasound applicator is developed for the treatment of vagina and rectum in combination with high dose rate brachytherapy. A cylindrical transducer (PZT-8, 1=1.5 cm, thickness=1.5mm OD=2.5 cm) was used as an energy source for induction of hyperthermia. Three single-element applicators were constructed to examine the performance of the PZT material. Vector impedance was measured to determine driving frequency. The efficiencies of the elements were determined using a radiation force technique to evaluate the feasibility of using the applicator as a hyperthermia source. A multi-element ultrasound applicator was designed using the PZT-8 material for the treatment of vagina. Results from the vector impedance measurements showed maximum magnitude at 1.78, 1.77, and 1.77 MHz for applicator 1,2, and 3, respectively. The radiation force measurements showed that the acoustic power of 40 watts was obtained in all three elements. The average efficiencies of the elements were 61.4, 65.2, and 54.0% for element 1, 2, and 3, respectively. The designed ultrasound hyperthermia applicator could be used in combination with high dose rate brachytherapy for the treatment of vagina and rectum. The use of this applicator with intracavitary brachytherapy could offer improved tumor control by increasing radiosensitiyity of the tumor.

  • PDF

Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods (방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.355-364
    • /
    • 2010
  • Considering biological safety, it is very important to measure acoustic power from ultrasonic array probe for diagnostic ultrasound imaging applications. In this paper, to measure acoustic power from each element on array probe for ultrasonic diagnostic equipment, we reconstruct and automate the acoustic power measurement system. The acoustic power from linear, phased and curved array were measured and analyzed. As a result of measurement, the effects caused by directivity of sound beam from curved array were founded. To remove these effects, we developed and applied the correction model. The proposed system is useful to evaluate characteristics of the acoustical output power of array probe.