• 제목/요약/키워드: Ultrasound power

검색결과 194건 처리시간 0.019초

A Calibration Study of Therapeutic Ultrasound Equipment Output Intensity Accuracy

  • Yuk, Goon-Chang;Ahn, Sang-Ho;Park, So-Hyun
    • The Journal of Korean Physical Therapy
    • /
    • 제23권3호
    • /
    • pp.37-42
    • /
    • 2011
  • Purpose: The principal objective of this study was to evaluate the power output of ultrasound in Korean clinics and compare the value with Korean and global standards. Methods: A total of 69 units were measured for ultrasound power output. The normal range of power output level was ${\pm}30%$ of the output set according to KFDA standards. Device model, manufacturer, ERA, and BNR were obtained via simple questionnaires. A portable ultrasound power meter was used for output measurement. Results: 37 machines, with reported ERA values, were assessed for power output per unit area. Of these machines, 13 (37.14%) were considered to be compliant with US FDA standards at 0.5, 1.0, 1.5, $20W/cm^2$ and 18 (51.43%) were considered within KFDA standards. The remainder of the machines were outside the standard error and evidenced irregular output levels, even though most of them were the same model. Conclusion: Appropriate ultrasound intensity is incredibly important for safety and effective use. Therefore, the KFDA standards regarding ultrasound may require revision in light of global standards, including BNR and ERA additionally, attention should be paid to regular calibration for safe use in clinical practice.

수근관 증후군의 Needle TENS, 초음파, 테이핑이 통증감소와 악력에 미치는 효과 (Effects of Pain Release and Power Grip after Apply Needle TENS, Ultrasound, Taping to Carpal Tunnel Syndrom Patients)

  • 한종만;공원태
    • 대한물리의학회지
    • /
    • 제1권1호
    • /
    • pp.49-57
    • /
    • 2006
  • Purpose : The Purpose of this study was to pain release and power grip in wrist affect of needle TENS(utilized of TENS in electrotherapy with oriental needle) and ultrasound therapy and taping with carpal tunnel syndrome patients. Methods : To study divided of each groups. each groups were apply to ultrasound therapy for 5 mintus, Taping was attached from wrist joint to elbow joint medial epicondly after maximum extension. needle TENS application was following of median nerve in wrist. Result : 1. The pain was released on needle TENS, ultrasound and taping groups of all(p<.05). 2. Power grip was enhanced in needle TENS and taping groups(p<.05) but ultrasound was no difference compared with before therapy. 3. Compared with needle TENS and taping therapy about pain release was needle TENS groups better than ultrasound groups(p<.05) Conclusion : Needle TENS, taping therapy are more effectable than ultrasound therapy for grip power and pain release. Needle TENS therapy is more effectable than taping therapy for pain release. Therefor, neddle TENS therapy is most effectable for pain release with carpal tunnel syndrome patients.

  • PDF

Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report

  • Oh, Song Hee;Seo, Yu-Kyeong;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.301-306
    • /
    • 2019
  • Purpose: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases. Materials and Methods: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow. Results: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan. Conclusion: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.

Power Assisted Liposuction(PAL)과 병용한 외부 초음파의 효과에 대한 비교 연구 (A Comparative Study of the Effect of External Ultrasound with Power Assisted Liposuction(PAL))

  • 송인수;박준;유영천;양원용;김진영
    • Archives of Plastic Surgery
    • /
    • 제32권4호
    • /
    • pp.496-502
    • /
    • 2005
  • This study was performed to compare the effect of external ultrasound assisted PAL(power assisted liposuction) with that of PAL alone. We performed 17 cases of liposuction from January 2003 to June 2003. For comparing both systems, we treated the right side(study group) with external ultrasound assisted PAL and the left side(control group) with PAL alone. To evaluate the difference in results between two groups, we surveyed three objective and four subjective items. Objectives were categorized as "Reduction rate of postoperative swelling", "Efficiency of suction" and "Histologic finding of aspirated fat tissue". Subjectives were also filed as "Degree of postoperative bruising", "Cannula resistance that operator felt", "Degree of postoperative pain" and "Patient's satisfaction". We assessed by questionnaire three times at 1day, 7 days and 30 days after operation. There were statistically significant differences in two of the subjective items; "Degree of postoperative pain at postoperative 1 day" and "Cannula resistance that operator felt". This study concludes that external ultrasound PAL is more effective high mobility of fat tissue and low tension of surrounding tissue. External ultrasound PAL will be more useful in case of large volume liposuction and revision procedures.

풍력발전기 부품소재의 마모결함 검출에 관한 연구 (A Study on Wear-type Defects of Part and Materials in Wind Power Generation)

  • 김성현;최승현;정나라;윤천한;김재열
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.989-995
    • /
    • 2013
  • Unlike fossil-or nuclear fuel-based power generation, wind power generation using inexhaustible wind energy is a pollution-free, hazardless power generation method. In this study, ultrasound thermography is used for fabricating specimens of wind power generator bearings and wind power generator supplement flanges, and an optimally designed ultrasound horn and ultrasound excitation system are used for detecting damage to part materials of a wind power generation setup. In addition, thermal flow analysis and ultrasonic thermography imaging are comparatively analyzed for improving the detection reliability in terms of surface and internal defects of part materials and for verifying the developed system's field applicability and reliability.

로그 전력 스펙트럼을 이용한 초음파 영상에서의 장기인식 (Organ Recognition in Ultrasound images Using Log Power Spectrum)

  • 박수진;손재곤;김남철
    • 한국통신학회논문지
    • /
    • 제28권9C호
    • /
    • pp.876-883
    • /
    • 2003
  • 본 논문에서는 초음파 영상에서 로그 전력 스펙트럼(log power spectrum)을 이용한 장기 인식 알고리듬을 제시한다. 제안한 알고리듬은 크게 특징추출과 특징분류의 두 단계로 구성된다. 특징추출에서는 이동불변의 성질을 가지는 로그 전력 스펙트럼을 이용하여 전처리를 수행한 입력 영상으로부터 장기 조직의 반향(echo of the tissue) 성분을 추출한다. 특징 분류에서는 마하라노비스(Mahalanobis) 거리를 사용하여 입력영상으로부터 추출한 특징벡터와 각 영상 부류의 평균벡터 사이의 유사도를 측정한다. 실제 초음파 영상에 대한 실험결과는 제안된 알고리듬이 전력 스펙트럼(power spectrum)과 유클리드(Euclid) 거리를 이용한 인식 알고리듬보다 최대 30% 향상된 인식률을, 또 가중 큐프런시(weighted quefrency) 복소 켑스트럼(complex cepstrum)을 이용한 알고리듬보다 10∼40% 향상된 인식률을 보여준다.

Intracavitary Ultrasound Hyperthermia Applicators for Gynecological Cancer

  • Lee, Rena J. .;Suh, Hyun-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.53-53
    • /
    • 2003
  • For evaluating the feasibility of treating recurrent lesions in the vaginal cuff and cervix by hyperthermia, ultrasound applicators were designed, constructed, and characterized. For the treatment A half-cylindrical transducer Cd=1cm, length=lcm) and cylindrical transducer (d=2.5cm, length= 1.5cm) were used to construct ovoid type and cylindrical applicators. For the ovoid type applicator, each element was operated at 1.5MHz and characterized by measuring transducer efficiency and acoustic power distribution. Thermocouple probes were used to measure the temperature rise in phantom. The element sizes used in this study were selected to be comparable for high dose rate brachytherapy colpostat applicator. Each element was powered separately to achieve a desired temperature pattern in a target. The acoustic output power as a function of applied electric power of the element 1 and 2 was linear over this 1 to 40 W range and efficiencies were 32.2${\pm}$3.4% and 46.2${\pm}$0.8%, respectively. The temperature measurements in phantom showed that 6$^{\circ}C$ temperature rise was achieved at 2 cm from the applicator surface. As a conclusion, the ability of the ultrasound colpostat applicator to be used for hyperthermia was demonstrated by measuring acoustic output power, ultrasound field distribution, and temperature rise in phantom. Based on the characteristics of this applicator, it has the potential to be useful for inducing hyperthermnia to the vaginal cuff in clinic.

  • PDF

이동형 초음파시스템에 적합한 다중 입력방식의 저전력 혼성 저잡음 증폭기 설계 (Design of Low-Power Hybrid LNA with Multi-Input for Mobile Ultrasound System)

  • 송재열;이경훈;박성모
    • 융합신호처리학회논문지
    • /
    • 제15권2호
    • /
    • pp.64-69
    • /
    • 2014
  • 초음파(Ultrasound) 시스템은 진단의학분야, 수중통신, 센서네트워크 등 현대산업분야에 광범위하게 사용되는 복잡한 무선 신호처리 시스템 중 하나이다. 최근에는 초음파 시스템의 소형화가 본격화 되고 있다. 본 논문에서는 소형화되고, 모바일화 되는 진단 초음파시스템에 적합한 혼성 저잡음증폭기(Low Noise Amplifier, LNA)를 개발 하였다. 제안된 LNA는 5dB이하의 낮은 잡음특성을 가지고, 다양한 초음파 변환기(Transducer)의 임피던스매칭을 위해 피드백 저항값들을 전기적으로 조정할 수 있도록 설계하였다. 주파수는 10kHz에서 150MHz까지 초음파주파수 전 대역을 지원할 수 있고, 슬립모드를 지원한다. 시스템의 특성에 맞춰 각각의 변환기를 통해 -17.8dB-29.5dB의 이득을 갖는다. 기존의 LNA와 비교해서 비슷한 성능에 소모전력은 최대 90%를 줄일 수 있었다.

초음파를 이용한 수용액 속의 MTBE 분해 특성 연구 (A Study on the Degradation Properties of MTBE in Solution using Ultrasound)

  • 김희석;양인호;오재일;허남국;정상조
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.522-529
    • /
    • 2009
  • To supply safe drinking water to areas lacking in water supply and drainage system, such as rural area and military bases in proximity to Demilitarized Zone, effective method for treating organic contaminants such as MTBE is required. This study focuses on seeking optimal conditions for effective degradation of MTBE using a bath type ultrasound reactor. Effectiveness of MTBE degradation by ultrasound is dependent on the frequency, power, temperature, treatment volume, initial concentration, catalyst, etc. In this study the degradation rate of MTBE by ultrasound was proportional to power/unit volume ratio and removal is relatively more efficient for 0.1 mM than for 1 mM of MTBE solution. Efficiency of ultrasound treatment for 1 mM MTBE solution was enhanced under bath temperature of $30^{\circ}C$ compared to $4^{\circ}C$, but the temperature effect was negligible for 0.1 mM MTBE solution. Also for 0.1 mM MTBE solution, effect of catalyst such as $TiO_2$ and $Fe^0$ on treatment speed was negligible, and zeolite even increases the time taken for the degradation. Under these specific experimental conditions of this study, the most determinant factor for degradation rate of MTBE in solution was frequency and power of ultrasound. The results have shown that a continuous ultrasound reactor system can be used for small scale remediation of organically polluted groundwater, under optimal conditions.