Usefulness of Ultrasonographic Follow Up Study After Repair of Peripheral Lateral Meniscal Tear (외측 반월상 연골 변연부 파열 봉합 후 초음파 추적 검사의 유용성)

  • Kim, Jung-Man;Im, Dong-Sun;Kim, Tae-Hyung;Shin, Eun-Su;Moon, Young-Suk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.15-19
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate usefulness of ultrasonography for the follow up of the repair of peripheral lateral meniscal tear compared to MRI. Materials and Methods: Fourteen patients who underwent repair of peripheral lateral meniscus tear were followed for at least 1 year (1 to 2.5 years). Ten cases were male, four cases were women, and average age was 36.1 years (19~53 years). After surgery ultrasonography and physical were performed at 6 weeks, 3 months, 6 months and 1 year. Results: Three cases had joint line tenderness or swelling on physical examination until 3 months, but after then, it disappeared. There is no re-tear in ultrasonograhic examination. Conclusion: The ultrasonography was useful for the follow-up study of the peripheral lateral meniscus tear.

  • PDF

The Usefulness of Fluorescein Angiography and Alternative Tests for Assessment of Fundus Hemorrhage (안저 출혈 시 형광안저혈관조영술 및 대체 검사의 유용성)

  • Yeon, Je-Jin;Koo, Bon-Kyeong;Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.266-276
    • /
    • 2021
  • Fundus hemorrhage refers to abnormalities in the retinal tissue and blood vessels. Therefore, when a hemorrhagic change in the fundus occurs, the ophthalmologist orders various ophthalmic tests to evaluate the degree of hemorrhage and determine the progress of the lesion before, during, and after treatment to accordingly establish a treatment plan. Currently, the most useful and universal fundus examination includes optical coherence tomography (OCT), fundus photography (FP), and fluorescein angiography (FAG). Existing fluorescein angiography test methods for establishing a treatment plan for severe fundus bleeding have limitations. The authors propose that peripheral pupil and the 5-quadrant method should be performed using ultra-wide-angle fluorescence fundus angiography (UWFFA). Using this method, it is possible to quickly determine the area to be described, avoid the radius of bleeding as much as possible, and provide the ophthalmologist with a range of damaged tissue and abnormal blood vessels. Nevertheless, there are cases in which ophthalmologists judge that fundus bleeding is so severe that ultra-wide-angle fluorescence fundus angiography is meaningless. In such cases, ophthalmic ultrasound and electroretinogram may be used in that order as alternative methods of examination. Therefore, some clinical situations require the use of ophthalmic ultrasound and electroretinogram and should be performed accurately.

Ultrasonographic Utility for Arthroscopic Examination of Knee (슬관절 관절경 검사 시 초음파 검사의 유용성)

  • Byun, Ki-Yong;Rhee, Kwang-Jin;Kim, Kyung-Cheon;Kim, Dong-Kyu;Kim, Bo-Kun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • Purpose: To evaluate the relationship between the real pathology & abnormal finding found by ultrasonography. Without an MRI test being done beforehand, an arthroscopy is done after an ultrasonography to show abnormal lesions during a knee abnormality. Materials and Methods: The subjects were 42 patients out of 49 cases, excluding those with rheumatoid arthritis, septic arthritis and patients suspected with a ligament tear, which were examined by ultrasonography alone before receiving a knee arthroscopy in our hospital from July 2007 to July 2008. In every case, a physical examination, simple X-ray and knee ultrasonography was done. An arthroscopy was performed when there was ultrasonographic abnormal finding. Before the procedure, a MRI test was not performed and when abnormal findings were found by an arthroscopy, an appropriate surgery was done. Results: During the ultrasonographic examination, there were various sized effusions in the suprapatellar pouch. Also, in addition there were eleven cases of medial meniscus abnormalities, sixteen cases of lateral meniscus abnormalities, and two cases of cystic lesions. Throughout the arthroscopic examination, there were 14 cases of medial meniscus abnormalities, 20 cases of lateral meniscus abnormalities, 15 cases of cartilage damages, 9 cases of medial pathologic plica, 2 cases of intra-articular loose bodies, 5 cases of chondromalacia, 2 cases of cyst, and 2 cases of synovitis. When an effusion abnormality was found by the ultrasonography in a suprapatellar pouch, there was a 100% probability of knee pathology. When a medial meniscus abnormality was found with an ultrasonography, there was a 90.9% probability of a real pathology. When a lateral meniscus abnormality was found there was 81.2% probability of a real pathology. Ultrasonography was 100% accurate when it came to cystic lesions. Conclusion: Knee ultrasonography performed before an arthroscopy seems to be a very useful examination method when suspecting intra-articular lesions.

  • PDF

Usefulness of Ultrasonographic Examination in Diagnosis and Follow-up of the Frozen Shoulder (동결견의 진단과 치료 경과 판정에 대한 초음파 검사의 유용성)

  • Choi, Chang-Hyuk;Kim, Seok-Jun;Lee, Sang-Hwa;Kim, Hee-Soo;Shim, Jung-Hyun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose: In order to know the effectiveness of ultrasonographic examination in diagnosis and follow-up evaluation for the frozen shoulder, we compared those with contralateral side in initial and after steroid injection. Materials and Methods: For the 20 unilateral frozen shoulder from July 2012 to July 2013, ultrasonographic examination was tried using reference line 1 (CBT: distance from coracoid process to LHB tendon) and line 2 (CBG: distance from coracoid process to bicipital groove). We tried 1 time steroid injection and compared the improvement in gross motion and reference line with 2 month, 4 month, and 6 month's serial ultrasonographic examination. Results: The differences on CBT line between lesion side and normal side were -5.6 mm, -5.0 mm, and -4.3 mm in neutral (Neut), external rotation (ER) and internal rotation (IR), respectively. The differences on CBG line were -6.1 mm, -4.7 mm, and -5.0 mm respectively (p<0.05). The changes in the reference line after steroid injection were evaluated at 2 month (CBT: -4.8 mm, -3.5 mm, -2.6 mm / CBG: -4.7 mm, -4.0 mm, -3.6 mm), 4 month (CBT: -4.7 mm, -3.2 mm, -1.7 mm / CBG: -4.3 mm, -3.7 mm, -1.2 mm), and 6 month (CBT: -1.1 mm, -2.9 mm, -0.5 mm / CBG: -1.2 mm, -0.7 mm, -0.9 mm). The gross motion was improved at 4 month after injection, from elevation $108^{\circ}$, ER $32^{\circ}$, IR L5 in initial to $133^{\circ}$, $42^{\circ}$, L3 respectively (p<0.05). Pain improved from 7.5 in initial to 3.0 at 2 month on visual analog scale (VAS). Conclusion: The serial examination after steroid injection revealed that the delayed improvement on reference line (6 month) compared with pain (2 month) or gross motion (4 month). Dynamic ultrasonogram was useful in diagnosis and follow-up evaluation of frozen shoulder.

  • PDF

Ultrasonographic Findings of the Shoulder in Asymptomatic High School Overhead Athletes (무증상 고교 상지 거상 운동 선수의 견관절 초음파 소견)

  • Cho, Su Hyun;Cho, Hyung Lae;Lee, Jung Su;Kim, Jung Woo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.81-88
    • /
    • 2012
  • Purpose: To evaluate the ultrasonographic (US) findings in both shoulders of asymptomatic high school overhead athletes and compare with healthy control. Materials and Methods: 33 individuals (age: $17.5{\pm}1.4$ years) participated in this study. We recruited two groups of high school male athletes, 13 baseball and 10 volleyball players without shoulder pain for recent 6 months as well as one control group of 10 untrained healthy high school students who were age-matched. Ultrasound measurements of thickness of biceps and supraspinatus tendon and acromio-humral distance (AHD) at 0o abduction were taken in dominant and nondominant shoulders. Results: On US examination, subacromial bursa effusion was observed in 5 of the dominant shoulders and in 1 of the nondominant shoulder of 23 overhead athletes and in none of the asymptomatic controls. The thickness of the biceps and supraspinatus tendons and AHD in both shoulders were significantly greater in the athletes than in the controls (P<0.05). We also found that the thickness of the biceps and supraspinatus tendon and AHD of the dominant shoulder were significantly greater than the non-dominant shoulder in overhead athletes (P<0.05), but there were no differences between baseball and volleyball players. Conclusion: Subacromial effusion could be found even in the asymptomatic stage overhead athlete and the thickness of the biceps and supraspinatus tendons and AHD were significantly greater in the overhead athletes than in the healthy controls. Our data is useful reference guide for the ultrasonographic diagnosis of shoulder pathologies occurring in overhead athletes.

  • PDF

Percutaneous Ultrasound-Guided Cholecystocentesis for Treatment of Extrahepatic Biliary Tract Obstruction Concurrent with Pancreatitis in Two Dogs (개에서 췌장염이 병발한 간외성 담관계 페쇄 치료를 위한 경피적 초음파 유도하 담낭 천자술 2예)

  • Cho, Hang-Myo;Chun, Haeng-Bok;Kim, Ju-Hyung;Chun, Hye-Young;Kim, Tae-Hun;Kang, Ji-Houn;Han, Tae-Sung;Na, Ki-Jeong;Yang, Mhan-Pyo;Kim, Gon-Hyung;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.25 no.4
    • /
    • pp.295-302
    • /
    • 2008
  • Two dogs were referred to Veterinary Medical Center, Chungbuk National University with the clinical signs of vomiting, diarrhea, anorexia, and jaundice. Both dogs were diagnosed as extrahepatic biliary tract obstruction(EHBO) with concurrent pancreatitis based on dilated common bile duct and hyperechoic or mixed-echoic pancreas in abdominal ultrasonographic examination and serum biochemical abnormalities, such as high serum bilirubin, cholesterol, and increased cholestatic enzyme activity. Percutaneous ultrasound-guided cholecytocentesis(PUCC) was performed to examine bile and decompress the gall bladder. After PUCC with medical therapy, both dogs were steadily improved clinical signs of jaundice and anorexia. Also, cholestatic enzyme activity and serum bilirubin concentration decreased. Any complications that have been described in previous studies, such as peritonitis resulting from bile leakage and hemorrhage, were not identified. It is assumed that percutaneous ultrasound guided cholecystocentesis may be an useful diagnostic and therapeutic tool in canine gallbladder disease and can be used easily and safely to gain bile for diagnosis of bacterial cholecytitis.

Effect of low intensity pulsed ultrasound (LIPUS) on bone healing around a titanium implant in the tibia of osteoporosis-induced rats (골다공증 유도 백서경골에 티타늄 임플란트 매식 시 저출력 초음파 적용이 골 치유에 미치는 영향)

  • Hwang, Young-Seob;Jeon, Hyun-Jun;Shin, Sang-Hun;Chung, In-Kyo;Kim, Gyoo-Cheon;Kim, Chul-Hoon;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.386-395
    • /
    • 2011
  • Introduction: Osteoporosis is a major health problem in the elderly that involves changes in the properties of bone as well as impaired bone healing around a titanium implant in both humans and animals. This study examined effect of low intensity pulsed ultrasound (LIPUS) on the bone healing process around a titanium implant in osteoporosis-induced rats. Materials and Methods: Sixteen rats were divided into two groups. A control group with osteoporosis induced by removing both ovaries and an experimental group of rats that were applied with LIPUS after osteoporosis had been induced. A screw type titanium implant (diameter, 2.0 mm: length, 3.5 mm, Cowell-Medi, KOREA) was placed into the tibias of 16 rats. The control and experimental group contained 8 rats each. The rats were sacrificed at 1, 2, 4, and 8 weeks after implantation to examine the histopathology and immunochemistry. Results: The histopathology examination revealed earlier new bone formation in the experimental group than the control group. In particular, at 1 week after implantation, more new bone matrix and collagen were observed around the implant of the experimental group compared to the control group. Immunochemistry analysis showed that the level of OPG expression of the experimental group was higher in the early stages than in the control group. After 8 weeks, the levels of OPG expression were similar in both groups. The expression level of receptor activator of nuclear factor kB ligand (RANKL) was stronger in the experimental group than the control group. After 4 weeks, the level of RANKL expression was similar in both groups. Conclusion: These results suggest that the application of LIPUS to implantation can promote bone healing around titanium in osteoporosis animals.

Effects of Body Composition and Nutrients Intake on the Calcaneal Broadband Ultrasound Attenuation in College Students (대학생의 신체계측치와 영양섭취실태가 종골초음파상태에 미치는 영향)

  • Jea, Eun-Joo;Byoun, Kwang-Eui;Youn, Jung-Eun;Lee, Byung-Kook;Kim, Hee-Seon
    • Korean Journal of Community Nutrition
    • /
    • v.14 no.5
    • /
    • pp.590-599
    • /
    • 2009
  • The purpose of this study was to analyze the relationship of nutritional status measured by the body composition and dietary nutrients intakes with calcaneal broadband ultrasound attenuation in college students. Total of 886 (462 male and 424 female) students who received health examination in May 2007 participated in this research. Participants bone status was measured by a quantitative ultrasound method and t-score was calculated via WHO guideline. For body composition measurements, body fat, height and weight were measured and BMI was calculated. Dietary data were collected by a 24-hour recall method. Based on Asia-Pacific standard of WHO, BMI was divided into 3 groups; UW (BMI < 18.5), NW + OW (18.5 $\leqq$ BMI < 25) and Obese group (25 $\leqq$ BMI). Among male students, 2.4% belong to the UW group, 45.0% to the NW+OW group and 52.6% belong to the obese group, bwhile 10.4% of female students belong to the UW group, 71.9% to the NW + OW group and 17.7% of female students belong to the Obese group. Differences among male and female students were statistically significant (p < 0.001). Students with higher BMI showed significantly higher bone health status. Male students did not show any significant differences in nutrients intakes by BMI groups while female students showed the higher intakes of energy, protein, pyridoxin, phosphorus, iron and zinc among NW + OW group than other groups (p < 0.05). The qualitative and quantitative evaluation of diet by BMI groups did not show any significant differences in both male and female students. The result of the multiple regression analyses showed that the body fat and bone status was negatively related while energy intake was positively related with the bone status. These results revealed that bone health status was positively affected by BMI but not by body fat. In conclusion, among those who are at their twenties, the period when the bone density becomes maximized, body fat may negatively affect bone health unlike during other life cycle stages.

Analysis of the Relationship between Abdominal Ultrasound Based Kidney Stones, Obesity and Metabolic Syndrome (복부 초음파 검사 기반 신장결석과 비만 및 대사증후군 관련성 분석)

  • Kim, Ju Hee;Jang, Hyon Chol;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.495-502
    • /
    • 2020
  • Kidney stones are a common disease with an annual prevalence of about 30,000 people in Korea, and are deeply related to an increase in chronic kidney disease, high blood pressure, coronary artery disease, metabolic syndrome, type 2 diabetes, hyperlipidemia, and abdominal obesity. Therefore, in this study, 135 examinees who visited a general hospital in Dalseong-gun from May 2019 to June 2020 for a medical examination were examined. The relationship between kidney stones and factors related to obesity and metabolic syndrome were found in abdominal ultrasound. I tried to find out the relevance. As a result of the study, the risk of kidney stones in the abnormal group was increased by 4.255 times compared to the normal group in total cholesterol factor, and the risk of kidney stones in the abnormal group was increased by 2.072 times compared to the normal group in the low-density lipoprotein cholesterol factor. Total cholesterol factor and low-density lipoprotein cholesterol It was found that the factor affects the prevalence of kidney stones and metabolic syndrome. Since the risk of kidney stones is related to total cholesterol and low-density lipoprotein cholesterol factors, active attention should be paid to preventive purposes through health check-ups.

Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography (근골격계 초음파검사에 사용되는 표재성 검사용 젤 패드 물질의 유용성 평가)

  • Han, Mi-Ran;Kwak, Jong-Gil;Song, Jong-Nam;Jang, Seong-Ju;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.899-909
    • /
    • 2021
  • In Musculoskeletal ultrasound examination, a linear transducer (12-5 MHz) with a contact surface length of 6 cm, which is commonly distributed in medical institutions, does not contact with bent fingers and wrist depressions only by using a conventional liquid ultrasound gel, which causes image loss. In order to solve this image loss, the use of commercially available Water gel pad is increasing. However, it is a disposable medical product. Repeated use is prohibited and expensive. In this study, in order to reduce the economic burden caused by the use of the commercialized Water gel Pad, we searched for water-soluble food thickener powder that can be easily purchased around our lives and manufactured Gel pads. Among them, kappa-Carrageenan Gel Pad, iota-Carrageenan Gel Pad, and Agar-Agar Gel Pad satisfied the evaluation criteria without artifacts in image evaluation using the N-365 Multipurpose Phantom. Also, the price to purchase the food thickener powder was about 38 times cheaper than the existing commercialized Water gel pad. As a result, if you use the food thickener powder such as kappa-Carrageenan, iota-Carrageenan and Agar-Agar to make solidified elastic Gel pad without a cover instead of the commercially available expensive disposable Water gel pad, the convenience and usefulness of use are improved. It is judged that the manufactured Gel pads can contribute well to the role of efficient ultrasound propagation medium.