• Title/Summary/Keyword: Ultrasound diagnostic system

Search Result 79, Processing Time 0.022 seconds

A study on the development of Pulsed Doppler System using Auto-Correlation (Auto-Correlation을 이용한 펄스 도플러 시스템에 관한 연구)

  • Lim, Chun-Sung;Rang, Chung-Shin;Lee, Hang-Sei;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.705-708
    • /
    • 1988
  • Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.

  • PDF

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

의무 기록용 워크스테이션 개발에 관한 연구

  • Kim, Won-Gi;Kim, Nam-Hyeon;Huh, Jae-Man
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.277-282
    • /
    • 1990
  • A workstation for archiving and communication of medical records is developed for clinical use in hospital. In this system, handwritten diagnostic reports, medical recording papers such as ECG and EEG etc., and ultrasound images are stored in optical disks instead of papers. This system improves medical service owing to speedy diagnosis by fast finding the patient's medical chart, and curtails the cost of archiving medical charts economically. If this system can be combined with already developed MPACS, then integrated medical image di- agnosis will be possible.

  • PDF

Grading meat quality of Hanwoo based on SFTA and AdaBoost (SFTA와 AdaBoost 기반 한우의 육질 등급 분석)

  • Cho, Hyunhak;Kim, Eun Kyeong;Jang, Eunseok;Kim, Kwang Baek;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.6
    • /
    • pp.433-438
    • /
    • 2016
  • This paper proposes a grade prediction method to measure meat quality in Hanwoo (Korean Native Cattle) using classification and feature extraction algorithms. The applied classification algorithm is an AdaBoost and the texture features of the given ultrasound images are extracted using SFTA. In this paper, as an initial phase, we selected ultrasound images of Hanwoo for verifying experimental results; however, we ultimately aimed to develop a diagnostic decision support system for human body scan using ultrasound images. The advantages of using ultrasound images of Hanwoo are: accurate grade prediction without butchery, optimizing shipping and feeding schedule and economic benefits. Researches on grade prediction using biometric data such as ultrasound images have been studied in countries like USA, Japan, and Korea. Studies have been based on accurate prediction method of different images obtained from different machines. However, the prediction accuracy is low. Therefore, we proposed a prediction method of meat quality. From the experimental results compared with that of the real grades, the experimental results demonstrated that the proposed method is superior to the other methods.

Assessment of Additional MRI-Detected Breast Lesions Using the Quantitative Analysis of Contrast-Enhanced Ultrasound Scans and Its Comparability with Dynamic Contrast-Enhanced MRI Findings of the Breast (유방자기공명영상에서 추가적으로 발견된 유방 병소에 대한 조영증강 초음파의 정량적 분석을 통한 진단 능력 평가와 동적 조영증강 유방 자기공명영상 결과와의 비교)

  • Sei Young Lee;Ok Hee Woo;Hye Seon Shin;Sung Eun Song;Kyu Ran Cho;Bo Kyoung Seo;Soon Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.889-902
    • /
    • 2021
  • Purpose To assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) for additional MR-detected enhancing lesions and to determine whether or not kinetic pattern results comparable to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast can be obtained using the quantitative analysis of CEUS. Materials and Methods In this single-center prospective study, a total of 71 additional MR-detected breast lesions were included. CEUS examination was performed, and lesions were categorized according to the Breast Imaging-Reporting and Data System (BI-RADS). The sensitivity, specificity, and diagnostic accuracy of CEUS were calculated by comparing the BI-RADS category to the final pathology results. The degree of agreement between CEUS and DCE-MRI kinetic patterns was evaluated using weighted kappa. Results On CEUS, 46 lesions were assigned as BI-RADS category 4B, 4C, or 5, while 25 lesions category 3 or 4A. The diagnostic performance of CEUS for enhancing lesions on DCE-MRI was excellent, with 84.9% sensitivity, 94.4% specificity, and 97.8% positive predictive value. A total of 57/71 (80%) lesions had correlating kinetic patterns and showed good agreement (weighted kappa = 0.66) between CEUS and DCE-MRI. Benign lesions showed excellent agreement (weighted kappa = 0.84), and invasive ductal carcinoma (IDC) showed good agreement (weighted kappa = 0.69). Conclusion The diagnostic performance of CEUS for additional MR-detected breast lesions was excellent. Accurate kinetic pattern assessment, fairly comparable to DCE-MRI, can be obtained for benign and IDC lesions using CEUS.

Breast Imaging Reporting and Data System (BI-RADS): Advantages and Limitations (유방영상 판독과 자료체계: 장점과 한계)

  • Ji Soo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.3-14
    • /
    • 2023
  • Breast Imaging Reporting and Data System (BI-RADS) is a communication and data tracking system that standardizes and controls the quality of reporting by presenting lexicon descriptors, assessment categories, and recommendations for managing breast lesions. Using standardized terminology recommended by BI-RADS, radiologists can concisely and reproducibly communicate breast imaging results to clinicians. They can also provide the estimated malignant probability of the lesions found and guide management for them by determining the final assessment category. The limitations of BI-RADS 5th edition currently in use are that there are some areas for which standardized terminologies still need to be established, and that the diagnostic criteria of MRI assessment categories 3 and 4 are ambiguous compared to those for mammography or ultrasound. The next revision of BI-RADS is expected to include solutions for overcoming current limitations.

Should Korean Medicine doctors use modern diagnostic medical devices? Survey result of public perspectives (국민인식을 기초로 한의사의 현대 진단의료기기 사용 법제화 필요성에 대한 제언 : 설문조사를 중심으로)

  • Juchul Kim;Byoungcheun Hwang;Manki Hwang;Seungmin Kathy Lee;EunHee Yi;Jungtae Leem
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.94-105
    • /
    • 2022
  • Objectives: This study investigated public opinion on the use of modern diagnostic medical devices by Korean Medicine doctors. Methods: A questionnaire looking into perceptions on the use of modern medical devices was developed. It was distributed by a third party and data was collected. Results were analyzed through frequency analysis, chi-square analysis (χ2-test), frequency and cross analysis using R program. The measurement variable in the study was the respondent's perspectives and expectations on the use of modern diagnostic medical devices by Korean Medicine doctors. The maximum significance level was 0.05. Results: There were a total of 3,000 responses and 80.8% of the respondents replied that there is a need for government-level discussion on endowing rights to Korean Medicine doctors as supervisors for safety management of radiation generating devices. Also, 83.3% of the respondents agreed the use of ultrasound imaging equipment in Korean Medicine clinics should be legalized. Conclusions: According to this study, respondents strongly support the use of modern diagnostic medical devices by Korean Medicine doctors. This is the first study to investigate public opinion in this area and it provides a significant insight into the public needs and desires for a wider scope of practice for Korean Medicine in the healthcare system.

Retrospective Study of 143 Dogs with Alimentary Foreign Bodies (개에서 발생한 소화기계 이물에 대한 회고분석 - 143 증례)

  • Choi, Jihye;Keh, Seoyeon;Kim, Hyunwook
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.49-55
    • /
    • 2015
  • This study was retrospectively investigated the clinical features, diagnostic imaging, treatment, and prognosis of foreign bodies according to alimentary site and type of foreign body, in 143 dogs. Among 28 breeds, Maltese, Shih Tzu, and terriers including the Yorkshire terrier were presented with high prevalence. Bone was the most commonly identified (33%) foreign body regardless of alimentary site. Approximately 76% of foreign bodies were in the stomach and small intestine. All esophageal foreign bodies were diagnosed on survey radiography, with the most common location being the caudal thoracic esophageal segment. Further diagnostic examinations including ultrasonography or contrast studies were additionally performed to detect radiolucent foreign bodies and perforation or leakage in the stomach and intestine. However, most seeds could be identified based on the characteristic features such as hyperdense thin double lines and inner gas on survey radiography. In conclusion, complications such as peritonitis and intestinal perforation were mainly observed in cases with seeds and linear foreign bodies. Especially, fabric foreign bodies could be induce peritonitis and re-perforation with high prevalence after surgical correction.

Radiologic Evaluation of Intraabdomenal Masses in Childhood (소아복부 종괴의 방사선학적 고찰)

  • Kwon, Hyuk-Po;Byun, Woo-Mok;Hwang, Mi-Soo;Kim, Sun-Yang;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1988
  • The abdominal tumors in children are different from those of adult. These tumors are the third most common one, preceded by leukemia and brain tumors, in children under 15 years. X-ray examination is the most important method among diagnostic approaches. The role of diagnostic imaging is to identify the precise anatomic location and extent of pathologic process with the minimal number of imaging procedures. 23 cases of abdominal tumors were reviewed in respect of age incidence, site of origin, radiologic findings. The results are briefly summarized as follows : 1. Neuroblastoma was the most common(6 cases) and wi1m's tumor(5 cases), choledocal cyst(4 cases), ovarian mass(3 cases), hydronephrosis(2 cases), were descending order in frequency. 2. The most common site was retroperitoneum(60%). Kidney was the single most common site of origin. 3. Radiologic findings. The most common findings of plain radiography was ill defined soft tissue mass and this method was helpful in the presence of calcification especially in neuroblastoma. Ultrasonographic pattern was anechoic(cystic), echoic or mixed pattern, but this method provide less precise anatomical details, nevertheless ultrasonography wes paticullary useful imaging modality for the pediatric abdominal tumors. IVP findings were renal displacement, caliceopelvic system distortion or nonvisualization of kidney, these information was helpful in determining the location of tumors. CT scan showed homogenous or inhomogenous, cystic or solid, mass with their anatomic location. 4. Ultrasonography was the most widely used specific diagnostic method, but had limited value in detecting the anatomic location of tumors. CT scan was superior to ultrasound for determining the extent of tumors.

  • PDF

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF