• Title/Summary/Keyword: Ultrasound Scanning

Search Result 100, Processing Time 0.027 seconds

Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment (자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성)

  • Seo, Eun-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

High Frequency Ultrasound and Its Applications to Animal and Human Imaging Focusing on Vessel and Blood (고주파 초음파의 그 응용: 혈관과 혈액을 중심으로한 동물과 인체 영상)

  • Bok, Tae-Hoon;Paeng, Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.2E
    • /
    • pp.73-85
    • /
    • 2010
  • In the diagnostic ultrasound (US) transducer technology, the high frequency US(HFUS) transducer over 20 MHz is one of the current issues to be pursued for better resolution with the expense of penetration. HFUS single element transducers and the mechanical scanning systems for imaging are reviewed, and HFUS array transducers are also briefly summarized. HFUS applications such as the human applications in ophthalmology and dermatology and small animal applications for research purposes are reviewed with vascular and blood imaging in this paper.

Ultrasound Synthetic Aperture Beamformer Architecture Based on the Simultaneous Multi-scanning Approach (동시 다중 주사 방식의 초음파 합성구경 빔포머 구조)

  • Lee, Yu-Hwa;Kim, Seung-Soo;Ahn, Young-Bok;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.803-810
    • /
    • 2007
  • Although synthetic aperture focusing techniques can improve the spatial resolution of ultrasound imaging, they have not been employed in a commercial product because they require a real-time N-channel beamformer with a tremendously increased hardware complexity for simultaneous beamforming along M multiple lines. In this paper, a hardware-efficient beamformer architecture for synthetic aperture focusing is presented. In contrast to the straightforward design using NM delay calculators, the proposed method utilizes only M delay calculators by sharing the same values among the focusing delays which should be calculated at the same time between the N channels for all imaging points along the M scan lines. In general, synthetic aperture beamforming requires M 2-port memories. In the proposed beamformer, the input data for each channel is first upsampled with a 4-fold interpolator and each polyphase component of the interpolator output is stored into a 2-port memory separately, requiring 4M 2-port memories for each channel. By properly limiting the area formed with the synthetic aperture focusing, the input memory buffer can be implemented with only 4 2-port memories and one short multi-port memory.

Accuracy of Ultrasonography in Early Pregnancy Diagnosis in Doe

  • Singh, N.S.;Gawande, P.G.;Mishra, O.P.;Nema, R.K.;Mishra, U.K.;Singh, Mohan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.6
    • /
    • pp.760-768
    • /
    • 2004
  • The present study was undertaken to evaluate the accuracy of ultrasonography in early pregnancy diagnosis in goats. Ultrasonographic scanning with real time B-mode ultrasound machine having 5 MHz linear array transducer was performed on gravid uterus (n=24) obtained from slaughterhouse (Group I). Crown rump length (CRL) measured by ultrasound was found significantly different (p<0.05) with actual CRL measured after dissection in early pregnancy. However, age predicted by ultrasound through the measurement of CRL was found highly correlated (r=0.92) with age measured after dissection through CRL and the weight of fetus. Ages predicted by ultrasound through the measurement of trunk diameter (TD) and uterine diameter (UD) and ages measured after dissection were found highly and equally correlated (r=0.98) and did not differ significantly. Data from six does synchronized (Group II) with PGF2$\alpha$ (Estrumate) at 11 days apart were collected through ultrasound from 17 to 42 days post breding. The correlation between CRL and gestational age was high (r=0.97) in day 30 to 42 post breeding. A high coefficient of correlation (r=0.98) was also observed between predicated age by ultrasound and actual age calculated after kidding. The correlation between CRL and gestational age by the formula Y=(a+bX) i.e. Y=24.42+0.39 X where Y=gestational age and X=CRL, was recorded very high (r=0.99). Accuracy of ultrasonography was lowest on day 17 to 19 (66%) and reached 100% on day 34. Data from 30 does (group III) randomly subjected to only one time ultrasounds scanning to assess the accuracy of pregnancy diagnosis were also obtained. Ages predicted by TD and UD measurements were observed to be non-significantly different with actual age obtained after kidding and correlation between ages predicted by TD and UD measurement with actual age after kidding was found equally and highly correlated (r=0.98). The operator's accuracy in the whole experiment including all three groups was found to be 92%. The sensitivity was 93% and specificity was 86%. From the present study, it was observed that CRL was the most reliable parameter to find out gestational age in early pregnancy and the new formula derived was found very accurate to find out gestational age. TD and UD were also found to be equally reliable parameter to find out gestational age in mid and late stage of pregnancy through ultrasonography. It was concluded that ultrasonography by real time B mode with 5 MHz transrectal transducer was found to be reliable, safe and accurate and practicable means in diagnosing early pregnancy diagnosis as early as 25 days post breeding.

Comparison of Automated Breast Volume Scanning and Hand-Held Ultrasound in the Detection of Breast Cancer: an Analysis of 5,566 Patient Evaluations

  • Choi, Woo Jung;Cha, Joo Hee;Kim, Hak Hee;Shin, Hee Jung;Kim, Hyunji;Chae, Eun Young;Hong, Min Ji
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9101-9105
    • /
    • 2014
  • Background: The purpose of this study was to compare the accuracy and effectiveness of automated breast volume scanning (ABVS) and hand-held ultrasound (HHUS) in the detection of breast cancer in a large population group with a long-term follow-up, and to investigate whether different ultrasound systems may influence the estimation of cancer detection. Materials and Methods: Institutional review board approval was obtained for this retrospective study, and informed consent was waived. From September 2010 to August 2011, a total of 1,866 ABVS and 3,700 HHUS participants, who underwent these procedures at our institute, were included in this study. Cancers occurring during the study and subsequent follow-up were evaluated. The reference standard was a combination of histology and follow-up imaging (${\geq}12months$). The recall rate, cancer detection yield, diagnostic accuracy, sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values were calculated with exact 95% confidence intervals. Results: The recall rate was 2.57 per 1,000 (48/1,866) for ABVS and 3.57 per 1,000 (132/3,700) for HHUS, with a significant difference (p=0.048). The cancer detection yield was 3.8 per 1,000 for ABVS and 2.7 per 1,000 for HHUS. The diagnostic accuracy was 97.7% for ABVS and 96.5% for HHUS with statistical significance (p=0.018). The specificity of ABVS and HHUS were 97.8%, 96.7%, respectively (p=0.022). Conclusions: ABVS shows a comparable diagnostic performance to HHUS. ABVS is an effective supplemental tool for mammography in breast cancer detection in a large population.

Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom (자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가)

  • Lee, Hyun-Kyung;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.895-900
    • /
    • 2019
  • Ultrasound is known to be harmless to the human body and is widely used in obstetrics and gynecology to confirm the diagnosis and development status of fetus. Diagnosis Although long - term use of ultrasound may cause changes in body temperature, studies on the uterine temperature changes due to ultrasound have been lacking. The purpose of this study was to investigate the change of temperature according to ultrasonic scanning time using a self - produced uterine model phantom. Ultrasound equipment and a 4MHz convex probe were used to construct the uterine model phantom similar to the human uterus using acrylic and pig uterus, which are tissue equivalents. Three probe type thermometers were installed to measure the inside of the acrylic water tank, the uterus, and the atmospheric temperature. The temperature of the uterine phantom was ascertained by measuring the temperature of the subject for 6 hours, 361 times. In this study, the possibility of human body temperature elevation due to ultrasound could be confirmed and this study will be used as the basic data of ultrasonic heat absorption study.

Musculoskeletal Ultrasound Findings of Shoulder Pain Patients: A Retrospective Observational Study (근골격계 초음파 진단기기를 활용한 견관절 통증 환자의 초음파 소견: 후향적 관찰 연구)

  • Hyun-Tae Kim;Hye-Jin Park;Yeon-Woo Lee;Sun-Young Park;In Heo;Eui-Hyoung Hwang;Byung-Cheul Shin;Man-Suk Hwang
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.2
    • /
    • pp.77-85
    • /
    • 2023
  • Objectives The aim of this study is to retrospectively evaluate the shoulder lesions in patients experiencing shoulder pain through the use of musculoskeletal ultrasound during Korean medicine intervention treatments. Methods A total of 20 cases were collected, including biceps tendinitis (n=4), calcification (n=3), SASD bursitis (n=4), partial tear (n=2), full-thickness tear (n=1), tendinopathy (n=5), and impingement syndrome (n=1). Musculoskeletal ultrasound was used by Korean medicine doctors to perform real-time scanning and to explain the patient's condition during treatment sessions. Results The use of musculoskeletal ultrasound allowed Korean medicine doctors to perform treatments such as pharmacoacupuncture, acupotomy, and acupuncture more safely and effectively. Patients were able to better understand their conditions through real-time imaging and explanations provided by the doctors. Conclusions Musculoskeletal ultrasound has the potential to enhance the safety and efficacy of Korean medicine intervention treatments for patients with shoulder pain. Institutional or governmental support is needed to further promote the use of medical devices by Korean medicine doctors, ultimately leading to an increase in cases and clinical evidence.

Reliability Evaluation of Semiconductor using Ultrasound (초음파를 이용한 반도체의 신뢰성 평가)

  • Jang, Hyo-Seong;Ha, Job;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.598-606
    • /
    • 2001
  • Recently, semiconductor packages trend to be thinner, which makes difficult to detect defects therein. A preconditioning test is generally performed to evaluate the reliability of semiconductor packages. The test procedure includes two scanning acoustic microscope (SAM) tests at the beginning and end of the entire test, in order to help detect physical defects such as delaminations and package cracks. In particular, of primary concern are package cracks and delaminations caused by moisture absorbed under ambient conditions. This paper discusses the failure mechanism associated with the moisture absorbed and encapsulated in semiconductors, and the use SAM to detect failures such as tracks and delaminations grown during the preconditioning test.

  • PDF

Intelligent Collision Prevention Technique for Construction Equipment using Ultrasound Scanning (초음파 스캐닝을 활용한 지능형 건설기계 충돌방지 기술)

  • Lee, Jaehoon;Hwang, Yeongseo;Yang, Kanghyeok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.5
    • /
    • pp.48-54
    • /
    • 2021
  • According to the Ministry of Employment and Labor's statistics on occupational fatalities in South Korea, more than half of the fatalities in the past five years have occurred in the construction industry. The stuck-by and caught-in-between accidents associated with construction equipment is the major source of fatalities from construction sites. In order to prevent such accidents in construction sites, the government has spent lots of efforts including proposing the "special law on construction safety" and encouraging the implementation of new technology for accident prevention. However, numerous accidents are still occurred at construction sites and further efforts are still required. In this manner, this study developed a collision prevention technique that can prevent collision between equipment and worker by recognizing location and type of the nearby objects through ultrasound scanning. The study conducted a pilot experiment and the analysis results demonstrate the feasibility of achieving high performance in both object recognition and location estimation. The developed technique will contribute to prevent collision accidents at construction sites and provide the supplemental knowledge on developing automated collision prevention system for construction equipment.