• Title/Summary/Keyword: Ultrasound Imaging

Search Result 657, Processing Time 0.027 seconds

Modified Piezoelectric Ceramics for Portable Ultrasonic Medical Probe Application (휴대용 의료 초음파 프로브 적용을 위한 압전체 제조 및 특성)

  • Kang, Dong Heon;Chae, Mi Na;Hong, Se Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.483-488
    • /
    • 2016
  • Ultrasound imaging by using piezoelectric materials, such as lead zirconium titanate (PZT) has been one of the most preferred modes of imaging in the medical field due to its simple, low cost and non-ionizing radiation in comparison to other imaging techniques. Recently, the market demand for portable ultrasound is becoming larger with applications in developing countries, disaster area, military, and emergency purposes. However, most of ultrasound probes used is bulky and high power consumable, so unsuitable for such applications. In this study, the 3 layered ceramic specimen consisted of 128 pitches of $420{\mu}m$ in width and $450{\mu}m$ in thickness were prepared by using the Ti-rich PZT compositions co-fired at $1,050^{\circ}C$. Their electrical and ultrasound pulse-echo properties were investigated and compared to the single layer specimen. The 3 layered ultrasound probe showed 1.584 V of Vp-p, which is 3.2 times higher than single layered one, implying that it would allow effectively such a portable ultrasound probe system. The result were discussed in terms of higher capacitance, lower impedance and higher dielectric coefficient of the 3 layered ultrasound probe.

Development of a Mobile Ultrasound Scanner for Point-of-care Applications (현장 진단 응용을 위한 모바일 초음파 스캐너 개발)

  • Cho, Jeong;Sohn, Hak-Yeol;Kim, Gi-Duck;Song, J.H.;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.66-78
    • /
    • 2009
  • A mobile ultrasound scanner developed for use in point-of-care applications is introduced, which can not only provide ultrasound images but can also measure various bio-signals. The mobile ultrasound scanner is also designed to meet the demanding requirements for point-of-care diagnosis, such as battery-powered operation, portability in terms of size and weigh, and real-time wireless communications capability for remote diagnosis. To meet these requirements, an efficient beamforming method for high resolution imaging with a small number of active elements, a hardware efficient beamformer architecture, and echo processing algorithms with greatly reduced computational complexity have been developed. Experimental results show that the prototype mobile ultrasound scanner is fully functional and satisfies most of the design requirements.

Study on Changes in Shape of Denatured Area in Skull-mimicking Materials Using Focused Ultrasound Sonication

  • Min, JeongHwa;Kim, JuYoung;Jung, HyunDu;Kim, JaeYoung;Noh, SiCheol;Choi, HeungHo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.1
    • /
    • pp.28-34
    • /
    • 2014
  • Recently, ultrasound therapy has become a new and effective treatment for many brain diseases. Therefore, skull-mimicking phantoms have been developed to simulate the skull and brain tissue of a human and allow further research into ultrasound therapy. In this study, the suitability of various skull-mimicking materials(HDPE, POM C, Acrylic) for studies of brain-tumor treatments was evaluated using focused ultrasound. The acoustic properties of three synthetic resins were measured. The skull-mimicking materials were then combined with an egg white phantom to observe the differences in the ultrasound beam distortion according to the type of material. High-intensity polyethylene was found to be suitable as a skull-mimicking phantom because it had acoustic properties and a denatured-area shape that was close to those of the skull,. In this study, a skull-mimicking phantom with a multi-layer structure was produced after evaluating several skull-mimicking materials. This made it possible to predict the denaturation in a skull in relation to focused ultrasound. The development of a therapeutic protocol for a range of brain diseases will be useful in the future.

MRI Features for Prediction Malignant Intra-Mammary Lymph Nodes: Correlations with Mammography and Ultrasound

  • Kim, Meejung;Kang, Bong Joo;Park, Ga Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.2
    • /
    • pp.135-149
    • /
    • 2022
  • Purpose: To assess clinically significant imaging findings of malignant intramammary lymph nodes (IMLNs) in breast cancer patients and to evaluate their diagnostic performance in predicting malignant IMLN. Materials and Methods: A total of 110 cases with IMLN of BI-RADS category 3 or more, not typical benign IMLN, in MR of breast cancer patients between January 2016 and January 2021 were retrospectively reviewed. After excluding 33 cases, 77 cases were finally included. Among them, 58 and 19 were confirmed as benign and malignant, respectively. Qualitative and quantitative MR imaging features of the IMLN were retrospectively analyzed. Sizes and final assessment categories of IMLN on MRI, mammography, and ultrasound were reviewed. Diagnostic performances of imaging features on MRI, mammography, and ultrasound were then evaluated. Results: For qualitative MR features, shape, margin, and preserved central hilum were significantly different between benign and malignant groups (P < 0.05). For quantitative MR features, long diameter over 6 mm, short diameter over 4 mm, and cortical thickening over 3 mm showed high sensitivities in predicting malignant IMLNs (89.5%, 94.7%, and 100%, respectively). Size exceeding 1 cm showed high specificity and accuracy in predicting malignant IMLN on MR, mammography, and ultrasound (91.4% and 80.5%; 96.6% and 79.25; 98.3% and 80.5%, respectively). Conclusion: Various MR imaging features and size can be helpful for predicting malignant IMLN in breast cancer patients.

Molecular Imaging of Stretch-Induced Tissue Factor Expression in Carotid Arteries with Intravascular Ultrasound

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.1
    • /
    • pp.23-29
    • /
    • 2005
  • Molecular imaging with targeted contrast agents enables tissues to be distinguished by detecting specific cell-surface receptors. In the present study, a ligand-targeted acoustic nanoparticle system is used to identify angioplasty-induced expression of tissue factor by smooth muscle cell within carotid arteries. Pig carotid arteries were overstretched with balloon catheters, treated with tissue factor-targeted or a control nanoparticle system, and imaged with intravascular ultrasound before and after treatment. Tissue factor-targeted emulsion bound and increased the echogenicity and gray-scale levels of overstretched smooth muscle cell within the tunica media, versus no change in contralateral control arteries. Expression of stretch-induced tissue factor in carotid artery media was confirmed by immunohistochemistry. The potential for abnormal thrombogenicity of balloon-injured arteries, as reflected by smooth muscle expression of tissue factor, was imaged using a novel, targeted, nanoparticulate ultrasonic contrast agent.

  • PDF

An Improved Second-odrer Sampling Method for Digital Beam Forming in Ultrasound Imaging Systems (초음파 영상 시스템에서 디지탈 Beam Forming을 위한 개선된 2차 샘플링 방법)

  • 조완희;안영복
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.1
    • /
    • pp.110-119
    • /
    • 1995
  • The lateral resolution in an ultrasound imaging system is one of the most important factors for quality of the image and is determined by the beam focusing. For the better lateral resolution SDF(Sampled Delay Focusing) capable of digital focusing was proposed. The second-order sampling, one of band-width sampling methods, is suggested as being the best suitable for SDF because it allows total digital processing and is simple and economical. By proving that it introduces too much error, this article shows the second-order sampling is not appropriate for sampling of the wide-band signal generally used in ultrasound imaging systems. Also, this article suggests new sampling methods that maintain the advantages and reduce the unavoidable errors of the second-order sampling method. From computer simulation it is expected that the proposed methods reduce the errors of the second-order sampling method and can be used in real applications.

  • PDF

A New Synthetic Aperture Technique Using Linear Wave Fronts (선형 파면을 이용한 새로운 합성구경 기법)

  • 장진호;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.321-330
    • /
    • 2001
  • In this paper, we propose a new synthetic aperture focusing scheme for improving the lateral resolution which is one of the most important factors determining the quality of ultrasound imaging. The proposed scheme enables full round-trip dynamic focusing with approximately limited property. This properties are obtained through transmitting plane waves of which the traveling angle varies with the receive subaperture position, as opposed to stepping the spherical wave source across an array in other synthetic aperture focusing schemes, and employing dynamic focusing in receive. In this paper, the properties of the proposed scheme is analyzed in which a hypothetical infinite line source is used to transmit the plane waves and verified through computer simulation results. Also, we show that the proposed scheme is realizable with an array transducer with a finite aperture size. In summary, it is shown through comparison between the field contours of the proposed scheme and the conventional scheme that the proposed scheme can improve greatly the lateral resolution of ultrasound imaging.

  • PDF

Velocity Vector Imaging (속도 벡터 영상 방법)

  • Kwon, Sung-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.1E
    • /
    • pp.11-27
    • /
    • 2010
  • Nowadays, ultrasound Doppler imaging is widely used in assessing cardiovascular functions in the human body. However, a major drawback of ultrasonic Doppler methods is that they can provide information on blood flow velocity along the ultrasound beam propagation direction only. Thus, the blood flow velocity is estimated differently depending on the angle between the ultrasound beam and the flow direction. In order to overcome this limitation, there have been many researches devoted to estimating both axial and lateral velocities. The purpose of this article is to survey various two-dimensional velocity estimation methods in the context of Doppler imaging. Some velocity vector estimation methods can also be applied to determine tissue motion as required in elastography. The discussion is mainly concerned with the case of estimating a two-dimensional in-plane velocity vector involving the axial and lateral directions.

2D Sparse Array Transducer Optimization for 3D Ultrasound Imaging

  • Choi, Jae Hoon;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2014
  • A 3D ultrasound image is desired in many medical examinations. However, the implementation of a 2D array, which is needed for a 3D image, is challenging with respect to fabrication, interconnection and cabling. A 2D sparse array, which needs fewer elements than a dense array, is a realistic way to achieve 3D images. Because the number of ways the elements can be placed in an array is extremely large, a method for optimizing the array configuration is needed. Previous research placed the target point far from the transducer array, making it impossible to optimize the array in the operating range. In our study, we focused on optimizing a 2D sparse array transducer for 3D imaging by using a simulated annealing method. We compared the far-field optimization method with the near-field optimization method by analyzing a point-spread function (PSF). The resolution of the optimized sparse array is comparable to that of the dense array.

Blood Vessel Strain Imaging Using Linear Array Transducer (선형 트랜스듀서를 이용한 혈관 변형률 영상법)

  • Ahn, Dong-Ki;Jeong, Mok-Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.880-890
    • /
    • 2010
  • The intrasvascular ultrasound (IVUS) imaging technique is used to diagnose cerebrovascular diseases such as stroke. Recently, elasticity imaging methods have been investigated to diagnose blood clots attached to blood vessel intima. However, the IVUS imaging technique is an invasive method that requires a transducer to be inserted into blood vessel. In this paper, strain images are obtained of blood clots attached to blood vessel intima with data acquired from outside the blood vessel using a linear array transducer. In order to measure the displacement of blood vessel accurately, experimental data are acquired by steering ultrasound beams so that they can intersect the blood vessel wall at right angles. The acquired rf data are demodulated to the baseband. The resulting complex baseband signals are then processed by an autocorrelation algorithm to compute the blood vessel movement and thereby produce strain image. This proposed method is verified by experiments on a plastic blood vessel mimicking phantom. The efficacy of the proposed method was verified using a home-made blood vessel mimicking phantom. The blood vessel mimicking phantom was constructed by making a 6 mm diameter hollow cylinder inside it to simulate a blood vessel and adhering 2 mm thick soft plaque to the inner wall of the hollow cylinder. The RF data were acquired using a clinical ultrasound scanner (Accuvix XQ, Medison, Seoul. Korea) with a 7.5 MHz linear array transducer by steering ultrasound beams in steps of $1^{\circ}$ from $-40^{\circ}$ to $40^{\circ}$ for a total of 81 angles. Experimental results show that the plaque region near the blood vessel wall is softer than background tissue. Although the imaging region is restricted due to the limited range of angles for which scan lines are perpendicular to the wall, the feasibility of strain imaging is demonstrated.