• Title/Summary/Keyword: Ultrasound Image

Search Result 431, Processing Time 0.037 seconds

Diagnostic Usefulness of Digital Infrared Thermal Image in Carpal Tunnel Syndrome (수근관 증후군에서 적외선 체열 검사의 진단적 유용성)

  • Park, Jihyun;Lee, Jang Woo;Lee, Sang Eok;Kim, Byung Hee;Park, Dougho
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.70-75
    • /
    • 2019
  • Objective: The purpose of this study is to evaluate the usefulness of infrared thermography in patients with carpal tunnel syndrome by comparing with electrodiagnostic and ultrasonographic findings. Method: From January 2014 to October 2017, electrodiagnosis, ultrasound, and digital infrared thermal image (DITI) of unilateral carpal tunnel syndrome diagnosed in a single hospital were retrospectively analyzed. The subjects with bilateral symptoms of carpal tunnel syndrome, peripheral vascular disease, diabetes, thyroid disease, fibromyalgia, rheumatic disease, systemic infection, inflammation, malignant tumor, and other musculoskeletal disorders such as finger osteoarthritis, peripheral neuropathy, cervical radiculopathy, and the previous history of surgery were excluded. Results: Of 53 patients diagnosed with carpal tunnel syndrome, 11 were male and 42 were female. The visual analogue scale was 4.9 ± 1.9, and the duration of symptom was 11.8 ± 12.5 months. There was no statistically significant difference in the body surface temperature between the unaffected and affected sides. The severity of symptoms, electrodiagnostic findings, and cross-sectional area of the median nerve significantly correlates to each other. The temperature difference between the second fingers of the affected and unaffected sides showed a weak correlation with the amplitude of sensory nerve action potential and onset latency of compound muscle action potential, when there was no significant correlation with the other parameters. Conclusion: The difference in temperature on the surface of the body, which can be confirmed by DITI, is little diagnostic value when DITI is performed in unilateral carpal tunnel syndrome patients, especially when compared with ultrasonography.

A Performance Improvement of Ultrasonic Diagnosis Transducer by Transient Acoustic Field Analysis (과도음장 해석을 통한 초음파 진단 탐촉자의 성능 개선)

  • 박은주;송행용;김무준;김동현;이수성;하강열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.744-756
    • /
    • 2002
  • The transient acoustic fields formed by a 3.5 ㎒ curved linear array transducer which is commonly used in ultrasonic medical imaging system for diagnosis of abdomen are systematically analyzed to obtain new design parameters for the better acoustic image. In the analysis with an assumption of radiating waveform, element size, radius of curvature, amplitude apodization are considered as parameters giving constitutive relations with the fields. As simulation results, appropriate new parameters with the reduced curvature and elevation aperture and the apodization of Hamming window, which make an improved acoustic beam with lower side lobe levels than a conventional typical transducer, are obtained.

The Effects of Virtual Reality Based Treadmill Training on the Muscle Architecture of Gastrocnemius in Chronic Stroke Patients : Randomized Controlled Trial

  • Cho, KiHun
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.3
    • /
    • pp.1-11
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of virtual reality based treadmill training on muscle architecture of gastrocnemius in chronic stroke patients. Methods: Thirty chronic stroke patients were randomly assigned to either the virtual reality based treadmill training (VRTT) group (n=15) or treadmill training (TT) group (n=15). Both groups participated in a standard rehabilitation program; in addition, the VRTT group participated in virtual reality based treadmill training for 30 minutes per day, three times per week, for 6 weeks, and TT group participated in treadmill walking training for 30 minutes per day, three times per week, for 6 weeks. Ultrasound image was used for measurement of pennation angle and muscle thickness of the medial gastrocnemius muscle at rest and during maximum voluntary contraction. Results: In the paretic side medial gastrocnemius muscle, greater improvement on the pennation angle and muscle thickness while resting and maximal voluntary contraction were observed in the VRTT group compared with the TT group. Conclusion: Findings of this study demonstrated that the virtual reality based treadmill training has an effect on muscle architecture of medial gastrocnemius in chronic stroke patients.

Literature Review of Clinical Studies for the Relationship between Ultrasonographic Examination and Syndrome Differentiation Classification in Chinese Medicine (초음파영상검사와 한의변증분류와의 관계와 관련된 중의학 임상연구에 대한 문헌고찰)

  • Hwang, Ji Hye;Ko, Dongkun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.32 no.4
    • /
    • pp.217-225
    • /
    • 2018
  • This study was to investigate the relationship between ultrasonographic examination and pattern identification classification on cinical studies in chinese medicine. We searched clinical studies related correlation between ultrasonographic examination and pattern identification classification in chinese medicine, that published from 2013 to 2016 in China National Knowledge Infrastructure (CNKI) databases by keywords, 'ultrasound(超?)', 'chinese medicine(中?)', 'syndrome differentiation (辨?)'. Seventeen studies were found. There were 7 studies of gynecological diseases including polycystic ovary syndrome and uterine myoma, 5 studies of fatty liver, 3 studies of arthritis, and 1 studie of thyroid nodule and lymphadenopathy respectively. As a result, ii is thought that there was a certain degree of correlation between the change of the ultrasonographic image and the pathological types according to traditional chinese medicine (TCM) syndrome differentiation and ultrasonographic examination could be used as secondary means for the TCM syndrome differentiation classification. In conclusion, by using ultrasonograph device in a medicinal way of TCM and traditional korean medicine (TKM), it is thought that more detailed and accurate diagnosis and treatment are possible and the evidence for reasonableness of syndrome differentiation in TCM and TKM its validity can be secured.

New Circular Wave Generation Method for Synthetic Focusing in Ultrasonic Imaging Systems (초음파 영상 시스템에서 합성 집속을 위한 새로운 구면파 발생 방법)

  • Ahn, Young-Bok
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.798-802
    • /
    • 2007
  • The synthetic focusing in the ultrasonic imaging systems has been formed in the way that one element transmits a circular wave and receives an echo signal. The amplitude of the signal transmitted from one element is too small to propagate a long distance so that the SNR(Signal to Noise Ratio) is very low in an image obtained by the synthetic focusing. To solve this problem, a defocusing method which uses several elements has been proposed. In this method, the SNR is improved due to using several elements to transmit the circular wave. But if the number of transmitting elements increases, the phase distortion is severe in the defocusing method. In this paper, we propose a new method that can generate a circular wave using a lot of elements without phase distortion. At first, we generate limited plane waves with different propagation angles and then superpose them to make a circular wave. We show that the circular wave can be used to improve SNR in the real-time 3D ultrasonic imaging as well as the synthetic focusing through computer simulation and experiments.

Neck metastasis of invasive ductal carcinoma of breast causing voice change: a case report (음성변화를 주증상으로 내원한 유방암의 경부연조직 전이환자 1례)

  • Lee, Hyung Min;Park, Ji hoon;Kim, Jin Hwan;Kim, Jung Won;Lee, Dong Jin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.33 no.2
    • /
    • pp.67-70
    • /
    • 2017
  • We present a metastatic carcinoma from the breast to the neck soft tissue around common carotid artery, with a rare finding of voice change. A 60 year-old female patient presented with voice change for 7 months. Neck ultrasound revealed a soft tissue mass between internal jugular vein and common carotid artery. Result of fine needle aspiration biopsy was a metastatic carcinoma. Computed tomography and magnetic resonance image revealed $2.5{\times}3.0cm$ sized irregular marginated soft tissue mass in right lower neck encasing common carotid artery and internal jugular vein. Surgical resection was performed and pathologic result with immunohistochemical analysis confirmed the diagnosis of a metastatic invasive ductal carcinoma originated from breast.

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

The Measurement of the Depth of Crack using Images of SLAM (SLAM 영상을 이용한 크랙 깊이 측정)

  • Hwang, Ki-Hwan;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.51-56
    • /
    • 1997
  • In this paper, we studied the configuration and depth measurement method of the crack in the interior of solid with scanning laser acoustic microscope. Precision measurement method of crack depth is required in SLAM because that system reconstructs the shadow image to the transmission coefficient. We proposed this method that used geometrical structure to the shadow area of SLAM images obtained from oblique incidence and the mode conversion of ultrasound in specimen and then experimented it. For this experiment, we fabricated various specimens which had the vertical line-crack with different depth and made the wedge as 20$^{\circ}$ for oblique incidence. Experimental results showed that the shadow area of SLAM images were proportional to the depth of crack. Measured depth error to the crack was less than 6% compared with practical crack depth.

  • PDF

An Automatic Contour Detection of 2-D Echocardiograms Using the Heat Anisotropic Diffusion Method (Heat Anisotropic Diffusion 방법을 이용한 2차원 심초음파도에서 경계선 자동 검출)

  • 신동조;김동윤
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.79-90
    • /
    • 1996
  • In this paper, we present an automatic threshold decision method to detect the contour of the a 2-D echocarodiogram by using the Bayes estimator for the boundary-like region. The boundary-like region is constructed from the conduction coefficient of the heat anisotro-pic diffusion method which enforces the blurred image during the preprocessing step. For the boundary-like region, we used the Bayes estimator to select an optimal threshold level. From this threshold value, the contour of the echocardigrams can be detected automatically Finally by overlapping the estimated contour to the original echocardiogram, we can obtain the contour enforced ultrasound echocardiogram.

  • PDF

The Study of Asymmetrical of the Serratus Anterior and Lower Trapezius Muscles in Chronic Stroke Patients (만성 뇌졸중 환자의 앞 톱니근과 하부 등세모근의 비대칭성 연구)

  • Jeong, Ju-Ri;Lee, Wan-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.81-90
    • /
    • 2015
  • PURPOSE: The purpose of this study was to compare the muscle architecture of serratus anterior and lower trapezius using rehabilitative ultrasound imaging (RUSI) in affected and unaffected side of chronic stroke patients. METHODS: The participants were thirty five patients with stroke hemiplegia in this study. RUSI was used to measure the muscle thickness of the serratus anterior and lower trapezius muscles. We compared the muscle thickness according to affected side and sex, determined the reliability of the measurement image. Independent t-test, intra-class correlation coefficient (ICC) and standard error of measurement (SEM) were used for statistical analysis. RESULTS: Significant difference in muscle thickness of serratus anterior was observed between affected and unaffected side (p<.001). Muscle thickness according to gender showed a significant difference in unaffected side of serratus anterior (p<.05). Compare asymmetry ratio of serratus anterior and lower trapezius muscle thickness showed a significant difference (p<.001). ICC for intra-reliability was .944~.962 in serratus anterior and .873~.925 in lower trapezius muscle thickness, respectively. SEM was .001~.004 in serratus anterior and .002~.008 in lower trapezius muscle. CONCLUSION: This study, using RUSI, showed significant difference in muscle thickness of serratus anterior in affected and unaffected side of stroke patients. RUSI is a practical tool for measuring soft-tissue thickness in the scapular region muscle of stroke.