• Title/Summary/Keyword: Ultrasound Examination

Search Result 321, Processing Time 0.034 seconds

Prolonged oral sildenafil use-induced Mondor disease: a case report

  • Chung, Han Sol;Mun, You Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.3
    • /
    • pp.262-265
    • /
    • 2022
  • Penile Mondor disease (MD) is a palpable, painful, subcutaneous induration caused by superficial dorsal penile vein thrombosis. We report a case of penile MD that was suspected to be related to prolonged oral sildenafil use. A 46-year-old man visited our emergency department with sustained penile pain and swelling that began 7 hours after sexual intercourse. He had used oral sildenafil intermittently for 11 years and engaged in sexual intercourse the previous night after taking sildenafil. Examination revealed no evidence of intercourse-related trauma to the genital area or an increase in penile skin temperature. However, penile swelling and tenderness over the protruding dorsal penile vein were noted. A color Doppler ultrasound examination was performed immediately, which showed hyperechoic thrombosis in the right superficial dorsal penile vein that was dilated, with soft tissue swelling and no detectable flow signal in the thrombotic lesion. The patient was diagnosed as having penile MD. The patient was treated conservatively. Some reports have indicated the involvement of sildenafil in thrombogenesis. Physicians should be aware that prolonged oral sildenafil use may be associated with penile MD.

Usefulness of Serial Ultrasonography of the Rotator Cuff Repair (회전근 개 파열의 수술적 치료시 초음파 연속 검사의 유용성)

  • Park, Jae-Hyun;Choi, Won-Ki;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.78-85
    • /
    • 2008
  • Purpose: The findings of preoperative magnetic resonance imaging (MRI) and ultrasonography (US) examination in the diagnosis of rotator cuff tear were then compared with the findings of arthroscopic examination, and to evaluate the postoperative integrity of rotator cuff using serial US examination. Methods: Between February and May 2008, 29 patients with rotator cuff tear had undergone preoperative US and MRI examination and subsequent arthroscopic examination. And the results of MRI and US were compared with intra-operative results of the arthroscopic examination. We observed the postoperative integrity of rotator cuff using serial (postoperative 2 weeks, 6 weeks, 3 months) US examination. Results: The sensitivity of US and MRI for identifying rotator cuff tear were 100% and 100%. The sensitivity of US and MRI were 95% and 82% in full thickness tear, and 50%, 33% in partial thickness tear, respectively. Overall accuracy of US and MRI were 86%, 69%. Among 22 patients were operated for full thickness tear, intra-operative gap formation was identified in 11 patients (50%, small to medium 2 cases, large to massive 9 cases) which were identified at 2 weeks postoperative US. We could find 5 re-tears (23%, small to medium 1 case, large to massive 4 cases) on 6 weeks postoperative US after passive range of motion (ROM) exercise, and could also find 7 re-tears (32%, small to medium 2 cases, large to massive 5 cases)on 3 months postoperative US after active ROM exercise. Conclusion: Serial US after arthroscopic rotator cuff repair was useful to differentiate intra-operative gap formation from postoperative re-tear. We found 5 retears (23%) at 6 weeks and 7 retears (32%) at 3 months postoperative US, it was useful to make treatment plan during postoperative rehabilitation.

  • PDF

Thyroid Gland Evaluation of Adults in Their 20s by means of a Screening Ultrasound Test and a Self-Test (스크리닝 초음파검사와 자가진단에 의한 20대 성인의 갑상선 평가)

  • Ji, TaeJeong
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.347-354
    • /
    • 2014
  • Korea Central Cancer Registry reported in 2011 that the prevalence rate of thyroid cancer was about 19.6% (the highest) in both men and women. The ratio of thyroid cancer, among cancers that women suffer from, was about 31.1%, the highest among female cancers and about five times more than men. Regarding the incidence of thyroid cancer by age group, the crude rate was highest in women and men aged 15~34. From these figures it can be inferred that there is a greater relationship between thyroid cancer and hormones compared with other cancers. Therefore, young women aged 20~25, even if they are in full health, should undergo a medical examination. This study is aimed at examining changes in thyroid gland detected through self evaluation tests and the analysis of ultrasound screening images in persons aged 20~25. According to the study, 213 persons (about 46.6%) out of 457 people who took part in the study had abnormal echo patterns. With regard to women's abnormal patterns, about 73.4% of them were found to have calcified cystic, 11.8% diffuse-type low-echo and 7.3% cystic echo. With regard to male participants, about 61.1% were found to have calcified cystic, followed by 19.4% with the size of the isthmus increased and 13.9% with diffuse-type low-echo. According to the outcomes of an analysis regarding self-testing for hyperthyroidism, the average points of participants who were found to have abnormal echo patterns in ultrasound tests were 6.85 and the figure was 5.88 in persons with normal patterns. The figure was about 15% higher in abnormal respondents.

Relationship between the depth of cingulate sulcus on neonatal high resolution cranial ultrasound and gestational age (신생아 고해상 뇌 초음파검사에서 대상고랑의 깊이와 재태기간과의 관계)

  • Choi, Young Chil;Choi, Jin Yong;Lee, Jung Hwa
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.10
    • /
    • pp.1136-1139
    • /
    • 2009
  • Purpose:It is critical that the exact gestational age of a newborn baby, especially premature baby, be determined to evaluate the status of a disease and its management and to estimate the prognosis of a patient. This study aimed to investigate an easy and accurate method to estimate gestational age on cranial ultrasound, requiring minimal additional time and equipment. Methods:A high-resolution coronal sonographic image was obtained via the anterior fontanel with a 5-12 Mhz linear probe after the usual cranial sonographic examination. We measured the depth of cerebral hemisphere, thickness of corpus callosum, and depth of cingulate sulcus and obtained the correlations between these factors and gestational age. Results:Depth of cingulate sulcus had the highest correlation coefficiency with gestational age (r=0.878, P=0.000). All the cases, except for 2 cases, had a gestational age of more than 37 weeks, when the depths of cingulate sulcus were more than 0.55 cm, and had a gestational age less than 34 weeks, when the depths of cingulate sulcus were less than 0.35 cm. Conclusion:Measurement of the depth of cingulate sulcus was a simple and accurate method to estimate the gestational age on cranial ultrasound. The gestational age is more than 37 weeks, when the depth of cingulate sulcus is more than 0.55 cm, and is less than 34 weeks, when the depth of cingulate sulcus is less than 0.35 cm.

A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography (유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구)

  • Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.751-759
    • /
    • 2023
  • Breast ultrasonography is difficult to image in fatty breasts and to find micro-calcification, but the discovery of micro-calcification is very important for breast cancer screening. Among the color Doppler artifact of ultrasound, twinkle artifact mainly occur on strong reflectors such as stones or calcification in images, and evaluation methods using them are clinically being used. In this study, we are conducting experiments on the color Doppler settings of ultrasound equipment, such as repetition frequency, ensemble, persist, wall filtering, smoothing, linear density, and dissociation value, by producing a breast simulation phantom using the largest amount of calcium phosphate among breast implants. The purpose of this study was to improve the contrast of twinkle artifact in breast ultrasound examinations and to maximize their use in clinical practice. As a result, the pulse repetition frequency occurred in the range of 3.6 kHz to 7.2 kHz, and did not occur above 10.5 kHz. For ensembles, twinkle artifact occurred in all sizes of calcification under low conditions, and in threshold settings, the twinkle artifact increased slightly only under 80 to 100 conditions, and did not occur in 1 mm size calcification. Persist, wall filter, smoothing, and line density settings did not have much meaning in the setting variable because conditions did not increase by condition, and pulse repetition frequency, ensemble, and thresholds had the greatest impact on the twinkling artifact image. This study is expected to help examiners select optimal conditions to effectively increase twinkle artifact by adjusting color Doppler settings.

Statistical Analysis of Clustered Interval-Censored Data with Informative Cluster Size (정보적군집 크기를 가진 군집화된 구간 중도절단자료 분석을 위한결합모형의 적용)

  • Kim, Yang-Jin;Yoo, Han-Na
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.5
    • /
    • pp.689-696
    • /
    • 2010
  • Interval-censored data are commonly found in studies of diseases that progress without symptoms, which require clinical evaluation for detection. Several techniques have been suggested with independent assumption. However, the assumption will not be valid if observations come from clusters. Furthermore, when the cluster size relates to response variables, commonly used methods can bring biased results. For example, in a study on lymphatic filariasis, a parasitic disease where worms make several nests in the infected person's lymphatic vessels and reside until adulthood, the response variable of interest is the nest-extinction times. Since the extinction times of nests are checked by repeated ultrasound examinations, exact extinction times are not observed. Instead, data are composed of two examination points: the last examination time with living worms and the first examination time with dead worms. Furthermore, as Williamson et al. (2008) pointed out, larger nests show a tendency for low clearance rates. This association has been denoted as an informative cluster size. To analyze the relationship between the numbers of nests and interval-censored nest-extinction times, this study proposes a joint model for the relationship between cluster size and clustered interval-censored failure data.

True Aneurysm of the Common Digital Artery: Case Report (온 바닥 쪽 손가락 동맥에서 발생한 동맥류의 치험례)

  • Jang, Joon-Chul;Jeong, Seong-Ho;Han, Seung-Kyu;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.315-318
    • /
    • 2011
  • Purpose: An aneurysm is defined as a permanent, localized dilation of an artery with a 50% increase in diameter over its expected normal diameter. Aneurysms can be classified by cause as traumatic and nontraumatic. Traumatic aneurysms can be divided into true and false aneurysms. Nontraumatic causes of peripheral artery aneurysms include mycotic, atherosclerotic, inflammatory, and idiopathic. In the hand, true aneurysms occurring at the common digital artery have been rarely reported. We present a rare case of a true aneurysm of the common digital artery that was resected and reconstructed using a reversed vein graft. Methods: A 49-year-old male patient was refered to our institution with a $0.73{\times}0.44{\times}1.37cm$ sized pulsating mass between 2nd and 3rd flexor digitorum tendons on Lt. palm area. The mass had been present for 5 years and had increased in size over the previous year. No history of trauma was reported. After a physical examination and ultrasound sonography review, a diagnosis of aneurismal dilatation of common digital artery was made. Surgical treatment by excision of the aneurysm, and a reversed vein graft was performed. Results: Histologic examination of the specimen ($3.4{\times}0.7cm$) showed aneurismal dilatation, with elastin fibers present in the arterial wall. The lesions were healed without any complications and there were no evidence of recurrence. Doppler examination of the reconstruction showed good perfusion. Conclusion: Early excision is recommended to relieve symptoms and avoid neurologic damage. Also, artery reconstruction can be performed by primary end-to-end anastomosis or the placement of a reversed interposition vein graft. Micro surgical repair was the only possible treatment in this case. The authors believe that the vascular anatomy should always be restored as natural as possible.

BreastLight Apparatus Performance in Detection of Breast Masses Depends on Mass Size

  • Shiryazdi, Seyed Mostafa;Kargar, Saeed;Taheri-Nasaj, Hossein;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1181-1184
    • /
    • 2015
  • Background: Accurate measurement of breast mass size is fundamental for treatment planning. We evaluated performance of BreastLight apparatus in detection breast of masses with this in mind. Materials and Methods: From July 2011 to September 2013, a total of 500 women referred to mammography unit in Yazd, Iran for screening were recruited to this study. Performance of BreastLight in detection breast masses regard their sizeing, measured with clinical breast examination (CBE), mammography and sonography, was assessed. Sonographic and mammography examinations were performed according to breast density among women in two groups of women younger (n=105) and older (n=395) than 30 years. Size correlations were performed using Spearman rho analysis. Differences between mass size as assessed with the different methods (mammography, sonography, and clinical examination) and the BreastLight detection were analyzed using $X^2$-trend test. Results: Performance of the BreastLight in detection of lesions smaller than or equal to 1 cm assessed by CBE, mammography and sonography was 4.4%,7.7% and 12.5% and for masses larger than 4 cm was 65%, 100% and 57.1%, respectively. The performance of BreastLight in detection was significantly increased with larger masses (p<0.001). Conclusions: We conclude that clinical measurement of breast cancer size is as accurate as that from mammography or ultrasound. Accuracy can be improved by the use of a simple formula of both clinical and mammographic measurements.

A Case of Canine Ectopic Parasitism of Heartworm in the Systemic Circulation (개에서 발생한 전신 순환계의 심장사상충 이소기생 증례)

  • Jang, Hyo-Mi;Lee, Hee-Chun;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.347-351
    • /
    • 2015
  • A 3-year-old intact female Dachshund was referred due to paraplegia and cool extremities. History taking, physical examination, neurological examination, and blood profiling studies were evaluated to determine the diagnosis. Based on abdominal ultrasound and echocardiograph, features suggestive of adult heartworm were detected in aberrant places. The result of enzyme-linked immunosorbent assay (ELISA) testing with a commercial heartworm antigen kit was positive. The dog fell into a comatose state, and the client requested the dog be euthanized. On post-mortem examination, the patient was diagnosed with ectopic parasitism of heartworm in the left side of heart, aorta, aorta abdominalis, and iliac arteries, a circumstance that induced systemic thromboembolism. This case report describes the clinical, diagnostic imaging, and necropsy findings of canine ectopic parasitism of heartworm.

The Analysis of Satisfaction with Clinical Training and the Related Factors in the Korean Medicine Obstetrics and Gynecology (한방부인과학에서 임상실습교육의 만족도와 관련요인 분석)

  • Yang, Seung-Jeong;Park, Kyung-Mi;Cho, Seong-Hee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.1
    • /
    • pp.116-127
    • /
    • 2020
  • Objectives: The purpose of this study is to analyze csatisfaction with clinica1 training in the department of Korean Medicine Obstetrics and Gynecology and the related factors. Methods: All the students on the graduating class of school of Korean Medicine, Dong-Shin University must be trained for 1 year in the department of Korean Medicine Obstetrics and Gynecology according to clinical training guideline including Objective Structured Clinical Examination (OSCE). After completing clinical training, we distributed questionaries to them about a reflex of the object of study, usefulness, difficulty, satisfaction and preference. And then, we analyzed the related factors including descriptive statistics, frequency analysis and correlation analysis by SPSS 12.0. Results: In general, a reflex of the aim of study (7.31±1.59), satisfaction with contents (7.44±1.58), and difficulty (6.13±1.34) were evaluated restectively. There is no statistically significant difference with sex. There is a statistically significant positive correlation between a reflex of the aim of study and satisfaction with contents. The primary preferences of clinical practice were Clinic Training, Ward Training, PBL (Problem Based Learning), OSCE. In OSCE, a reflex of the aim of study (7.04±1.83) and usefulness (7.02±1.97) were highly evaluated. There is no statistically significant difference with sex. The primary preferences for clinical OSCE practice were breast examination, genital examination, ultrasound scan, and pap smear. Facilities and equipment (6.84±2.01), contents of clinical training (7.29±1.83), the handout (7.20±1.98) and time scheduling (7.29±1.90) were evaluated respectively in general composition of clinical training. Conclusions: Clinical training program in the department of Korean Medicine Obstetrics and Gynecology can be highly estimated from the viewpoint of satisfaction with clinical training and the related factors.