Browse > Article

True Aneurysm of the Common Digital Artery: Case Report  

Jang, Joon-Chul (Department of Plastic Surgery Korea University College of Medicine)
Jeong, Seong-Ho (Department of Plastic Surgery Korea University College of Medicine)
Han, Seung-Kyu (Department of Plastic Surgery Korea University College of Medicine)
Kim, Woo-Kyung (Department of Plastic Surgery Korea University College of Medicine)
Publication Information
Archives of Plastic Surgery / v.38, no.3, 2011 , pp. 315-318 More about this Journal
Abstract
Purpose: An aneurysm is defined as a permanent, localized dilation of an artery with a 50% increase in diameter over its expected normal diameter. Aneurysms can be classified by cause as traumatic and nontraumatic. Traumatic aneurysms can be divided into true and false aneurysms. Nontraumatic causes of peripheral artery aneurysms include mycotic, atherosclerotic, inflammatory, and idiopathic. In the hand, true aneurysms occurring at the common digital artery have been rarely reported. We present a rare case of a true aneurysm of the common digital artery that was resected and reconstructed using a reversed vein graft. Methods: A 49-year-old male patient was refered to our institution with a $0.73{\times}0.44{\times}1.37cm$ sized pulsating mass between 2nd and 3rd flexor digitorum tendons on Lt. palm area. The mass had been present for 5 years and had increased in size over the previous year. No history of trauma was reported. After a physical examination and ultrasound sonography review, a diagnosis of aneurismal dilatation of common digital artery was made. Surgical treatment by excision of the aneurysm, and a reversed vein graft was performed. Results: Histologic examination of the specimen ($3.4{\times}0.7cm$) showed aneurismal dilatation, with elastin fibers present in the arterial wall. The lesions were healed without any complications and there were no evidence of recurrence. Doppler examination of the reconstruction showed good perfusion. Conclusion: Early excision is recommended to relieve symptoms and avoid neurologic damage. Also, artery reconstruction can be performed by primary end-to-end anastomosis or the placement of a reversed interposition vein graft. Micro surgical repair was the only possible treatment in this case. The authors believe that the vascular anatomy should always be restored as natural as possible.
Keywords
True aneurysm; Digital artery;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Estrella EP, Lee EY: Aneurysm of the superficial palmar arch: a case report. Hand surg 13: 179, 2008   DOI   ScienceOn
2 Turner S, Howard CB, Dallimore NS: A case report of a true aneurysm of a digital artery. J Hand Surg Br 9: 205, 1984   DOI   ScienceOn
3 Baruch A: False aneurysm of the digital artery. Hand 9:195, 1977   DOI   ScienceOn
4 Abouzahr MK, Coppa LM, Boxt LM: Aneurysms of the digital arteries: a case report and literature review. J Hand Surg Am 22: 311, 1997   DOI   ScienceOn
5 Poirier RA, Stansel HC Jr: Arterial aneurysms of the hand. Am J Surg 124: 72, 1972   DOI   ScienceOn
6 Clark ET, Mass DP, Bassiouny HS, Zarins CK, Gewertz BL: True aneurismal disease in the hand and upper extremity. Ann Vasc Surg 5: 276, 1991   DOI   ScienceOn
7 Tummala RP, Chu RM, Madison MT, Myers M, Tubman D, Nussbaum ES: Outcomes after aneurysm rupture during endovascular coil embolization. Neurosurgery 49: 1059, 2001
8 Strauch B, Melone C, McClain SA, Lee BT: True aneurysms of the digital artery: case report. J Hand Surg Am 29: 54, 2004   DOI   ScienceOn